Power distributor, Application: Power supply, Connection method: M12-SPEEDCON-socket Metal, Number of
slots: 4, Number of positions: 4, Coding: T power, Slot assignment: single, Status indication: Yes, Universal;
Master cable connection: Plug-in master cable connection 90°, Shielding: No, Diagnostics port, M12, A-coded,
12-pos.
Product Features
Safety in the field, thanks to molded housing and high degree of protection
Save time, thanks to installation with SPEEDCON fast locking system
Convenient: increased machine availability thanks to quick and easy diagnostics
Flexible: distributor box with connector hood for on-site assembly
Key Commercial Data
Packing unit
1 pc
Custom tariff number
85444290
Country of origin
Germany
Technical data
General
Rated voltage
24 V DC
Max. operating voltage Umax
30.5 V DC
Current carrying capacity per I/O signal
10 A (M12 diagnostic socket for each channel max. 50 mA)
Current carrying capacity per slot
2x 9.25 A (at 40 °C)
Total rated current
70 A (at 40°C, observe the distribution of the current paths under load)
Protective circuit
Overload protection for the outputs Fuse in header
Number of positions
4
Number of slots
4
Flammability rating according to UL 94
V0
Sensor/actuator connection system
M12-SPEEDCON-socket
10/28/2015 Page 1 / 4
https://www.phoenixcontact.com/us/products/1411048
Power distributor - SACB-4/T-L-8FUSE DIAG CT AXL - 1411048
Technical data
Ambient conditions
Degree of protection
IP66
IP67
Ambient temperature (operation)
-25 °C ... 60 °C
Ambient temperature (storage/transport)
-25 °C ... 80 °C
Local diagnostics function
Local diagnostics
Supply voltage per module Green LED
Status display I/O Yellow LED
Master cable data/connection data
Connection method
Plug-in master cable connection
Conductor cross section min. (energy)
2.5 mm²
Conductor cross section max. (energy)
6 mm²
Conductor cross section AWG min. (energy)
14
Conductor cross section AWG max. (energy)
10
External cable diameter min.
9 mm
External cable diameter max.
15.5 mm
Tightening torque, cover screw
0.6 Nm
Tightening torque, union nut
5 Nm
Tightening torque slot sensor/actuator cable
0.4 Nm
Insulation material
Housing material
PBT
Material of the moulding mass
PUR
Contact material
Cu alloy
Contact surface material
pre-nickel plated, gold-plated
Contact carrier material
PA
Material of contact, master cable side
CU alloy
Material of contact surface, master cable side
Silver-plated
Material of the contact carrier on the master cable side
PC
Material of threaded sleeve
Zinc die-cast
Material of threaded sleeve surface
Nickel-plated
Sealing material
Viton (M12 socket)
NBR (Master cable side)
Classifications
eCl@ss
eCl@ss 5.1
27143423
10/28/2015 Page 2 / 4
https://www.phoenixcontact.com/us/products/1411048
Power distributor - SACB-4/T-L-8FUSE DIAG CT AXL - 1411048
Classifications
eCl@ss
eCl@ss 6.0
27143423
eCl@ss 8.0
27279219
ETIM
ETIM 5.0
EC002585
Drawings
Schematic diagram
Schematic diagram
10
2
3 11
4
4
1
1
5
9
12
3
2
8
Connector pin assignment of M12 socket, 4-pos., T-coded, view of socket
side
7
Pin assignment of M12 socket, 12-pos., A-coded, view of socket side,
assignment: see connection drawing
Connection diagram
Circuit diagram
M12 DIAG
1
2
3
4
5
6
7
8
9
10
11
12
6
3 (GND)
A
+ 24 V
S3
S1
A1
A3
A4
A2
S4
S2
n.c
n.c
The fuses for the individual current paths can be monitored via the M12
diagnostics interface. Monitoring is via optocouplers and is therefore
electrically isolated from the power distribution.
US
Fuse S1-S4 (each 10A)
(4x)
1 (Pot1)
B
C
2 (GND)
UA
Fuse A1-A4 (each 10A)
(4x)
4 (Pot2)
D
X31...X34
A
B
4
1
C
D
3
2
10/28/2015 Page 3 / 4
https://www.phoenixcontact.com/us/products/1411048
Power distributor - SACB-4/T-L-8FUSE DIAG CT AXL - 1411048
Dimensional drawing
212
30
60
64
185
Circuit diagram
4
3
C
D
- UA +
S2
10A
S1
10A
- US +
A
B
1
4
2
3
A1
10A
1
4
2
3
X32
X31
A2
10A
S4
10A
S3
10A
1
4
2
3
2
X34
X33
A3
10A
1
A4
10A
Phoenix Contact 2015 © - all rights reserved
http://www.phoenixcontact.com
10/28/2015 Page 4 / 4
很抱歉,暂时无法提供与“1411048”相匹配的价格&库存,您可以联系我们找货
免费人工找货