0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
1411048

1411048

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    -

  • 描述:

    POWER SUPPLY

  • 数据手册
  • 价格&库存
1411048 数据手册
https://www.phoenixcontact.com/us/products/1411048 Power distributor - SACB-4/T-L-8FUSE DIAG CT AXL - 1411048 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Power distributor, Application: Power supply, Connection method: M12-SPEEDCON-socket Metal, Number of slots: 4, Number of positions: 4, Coding: T power, Slot assignment: single, Status indication: Yes, Universal; Master cable connection: Plug-in master cable connection 90°, Shielding: No, Diagnostics port, M12, A-coded, 12-pos. Product Features  Safety in the field, thanks to molded housing and high degree of protection  Save time, thanks to installation with SPEEDCON fast locking system  Convenient: increased machine availability thanks to quick and easy diagnostics  Flexible: distributor box with connector hood for on-site assembly     Key Commercial Data Packing unit 1 pc Custom tariff number 85444290 Country of origin Germany Technical data General Rated voltage 24 V DC Max. operating voltage Umax 30.5 V DC Current carrying capacity per I/O signal 10 A (M12 diagnostic socket for each channel max. 50 mA) Current carrying capacity per slot 2x 9.25 A (at 40 °C) Total rated current 70 A (at 40°C, observe the distribution of the current paths under load) Protective circuit Overload protection for the outputs Fuse in header Number of positions 4 Number of slots 4 Flammability rating according to UL 94 V0 Sensor/actuator connection system M12-SPEEDCON-socket 10/28/2015   Page 1 / 4 https://www.phoenixcontact.com/us/products/1411048 Power distributor - SACB-4/T-L-8FUSE DIAG CT AXL - 1411048 Technical data Ambient conditions Degree of protection IP66 IP67 Ambient temperature (operation) -25 °C ... 60 °C Ambient temperature (storage/transport) -25 °C ... 80 °C Local diagnostics function Local diagnostics Supply voltage per module Green LED Status display I/O Yellow LED Master cable data/connection data Connection method Plug-in master cable connection Conductor cross section min. (energy) 2.5 mm² Conductor cross section max. (energy) 6 mm² Conductor cross section AWG min. (energy) 14 Conductor cross section AWG max. (energy) 10 External cable diameter min. 9 mm External cable diameter max. 15.5 mm Tightening torque, cover screw 0.6 Nm Tightening torque, union nut 5 Nm Tightening torque slot sensor/actuator cable 0.4 Nm Insulation material Housing material PBT Material of the moulding mass PUR Contact material Cu alloy Contact surface material pre-nickel plated, gold-plated Contact carrier material PA Material of contact, master cable side CU alloy Material of contact surface, master cable side Silver-plated Material of the contact carrier on the master cable side PC Material of threaded sleeve Zinc die-cast Material of threaded sleeve surface Nickel-plated Sealing material Viton (M12 socket) NBR (Master cable side) Classifications eCl@ss eCl@ss 5.1 27143423 10/28/2015   Page 2 / 4 https://www.phoenixcontact.com/us/products/1411048 Power distributor - SACB-4/T-L-8FUSE DIAG CT AXL - 1411048 Classifications eCl@ss eCl@ss 6.0 27143423 eCl@ss 8.0 27279219 ETIM ETIM 5.0 EC002585 Drawings Schematic diagram Schematic diagram 10 2 3 11 4 4 1 1 5 9 12 3 2 8 Connector pin assignment of M12 socket, 4-pos., T-coded, view of socket side 7 Pin assignment of M12 socket, 12-pos., A-coded, view of socket side, assignment: see connection drawing Connection diagram Circuit diagram M12 DIAG 1 2 3 4 5 6 7 8 9 10 11 12 6 3 (GND) A + 24 V S3 S1 A1 A3 A4 A2 S4 S2 n.c n.c The fuses for the individual current paths can be monitored via the M12 diagnostics interface. Monitoring is via optocouplers and is therefore electrically isolated from the power distribution. US Fuse S1-S4 (each 10A) (4x) 1 (Pot1) B C 2 (GND) UA Fuse A1-A4 (each 10A) (4x) 4 (Pot2) D X31...X34 A B 4 1 C D 3 2 10/28/2015   Page 3 / 4 https://www.phoenixcontact.com/us/products/1411048 Power distributor - SACB-4/T-L-8FUSE DIAG CT AXL - 1411048 Dimensional drawing 212 30 60 64 185 Circuit diagram 4 3 C D - UA + S2 10A S1 10A - US + A B 1 4 2 3 A1 10A 1 4 2 3 X32 X31 A2 10A S4 10A S3 10A 1 4 2 3 2 X34 X33 A3 10A 1 A4 10A Phoenix Contact 2015 © - all rights reserved http://www.phoenixcontact.com 10/28/2015   Page 4 / 4
1411048 价格&库存

很抱歉,暂时无法提供与“1411048”相匹配的价格&库存,您可以联系我们找货

免费人工找货