Bus system cable, Ethernet CAT5 (100 Mbps), 4-position, PVC/PVC, green RAL 6018, shielded, Plug straight
M12, D-coded, on Socket straight M12, D-coded, Cable length: 20 m
Key Commercial Data
Packing unit
1 pc
Weight per Piece (excluding packing)
1380.0 g
Custom tariff number
85444290
Country of origin
Poland
Technical data
Dimensions
Length of cable
20 m
Ambient conditions
Degree of protection
IP65
IP67
IP68
General
Rated current at 40°C
4A
Rated voltage
250 V
Number of positions
4
Insulation resistance
≥ 100 MΩ
Coding
D - data
Signal type/category
Ethernet CAT5, 100 Mbps
Status display
No
Overvoltage category
II
Pollution degree
3
10/29/2015 Page 1 / 4
https://www.phoenixcontact.com/us/products/1567966
Bus system cable - SAC-4P-M12MSD/20,0-933/M12FSD - 1567966
Technical data
General
Insertion/withdrawal cycles
≥ 100
Material
Flammability rating according to UL 94
V0
Contact material
CuSn
Contact surface material
Ni/Au
Contact carrier material
PA 66
Material of grip body
TPU, hardly inflammable, self-extinguishing
Material, knurls
Zinc die-cast, nickel-plated
Sealing material
NBR
Cable
Cable type
PROFINET PVC stranded CAT5
Cable type (abbreviation)
93B
Cable abbreviation
2YY(ST)CY
UL AWM style
21694
Cable structure
1x4xAWG22/7; SF/TQ
Conductor cross section
4x 0.34 mm²
AWG signal line
22
Conductor structure signal line
7x 0.25 mm
Core diameter including insulation
1.55 mm
Wire colors
White, yellow, blue, orange
Overall twist
Star quad
Shielding
Aluminum-coated foil, tinned copper braided shield
Optical shield covering
85 %
External sheath, color
green RAL 6018
Outer sheath thickness
approx. 0.9 mm
External cable diameter D
6.5 mm ±0.2 mm
Minimum bending radius, fixed installation
3xD
Minimum bending radius, flexible installation
7xD
Cable weight
67 kg/km
Outer sheath, material
PVC
Material, inner sheath
PVC
Material conductor insulation
PE
Conductor material
Tin-plated Cu litz wires
Insulation resistance
≥ 500 MΩ*km
Loop resistance
≤ 120 Ω (per kilometer)
Wave impedance
100 Ω ±15 Ω (at 100 MHz)
10/29/2015 Page 2 / 4
https://www.phoenixcontact.com/us/products/1567966
Bus system cable - SAC-4P-M12MSD/20,0-933/M12FSD - 1567966
Technical data
Cable
Signal runtime
5.3 ns/m
Coupling resistance
≤ 20.00 mΩ/m (At 10 MHz)
Nominal voltage, cable
600 V
Test voltage Core/Core
2000 V (50 Hz, 1 min.)
Test voltage Core/Shield
2000 V (50 Hz, 1 min.)
Flame resistance
According to UL 1685 (CSA FT 4)
Resistance to oil
Resistant to oil to a limited extent
Other resistance
UV resistant According to UL 1581, Section 1200
Ambient temperature (operation)
-40 °C ... 70 °C (cable, fixed installation)
-40 °C ... 70 °C (cable, flexible installation)
Classifications
eCl@ss
eCl@ss 4.0
27060306
eCl@ss 4.1
27060306
eCl@ss 5.0
27061801
eCl@ss 5.1
27061801
eCl@ss 6.0
27061801
eCl@ss 7.0
27061801
eCl@ss 8.0
27279218
ETIM
ETIM 3.0
EC001855
ETIM 4.0
EC001855
ETIM 5.0
EC001855
UNSPSC
UNSPSC 6.01
31251501
UNSPSC 7.0901
31251501
UNSPSC 11
31251501
UNSPSC 12.01
31251501
UNSPSC 13.2
31251501
Drawings
10/29/2015 Page 3 / 4
https://www.phoenixcontact.com/us/products/1567966
Bus system cable - SAC-4P-M12MSD/20,0-933/M12FSD - 1567966
Schematic diagram
Schematic diagram
Pin assignment M12 male connector, 4-pos., D-coded, male side
Pin assignment M12 socket, 4-pos., D-coded, female side
Cable cross section
Dimensional drawing
Ø12
M12
Ø14,8
47,3
PROFINET PVC stranded CAT5 [93B]
Plug, M12 x 1, straight, shielded
Dimensional drawing
Ø15
M12
Ø12
44,5
M12 x 1 socket, straight, shielded