Description
The SHDSL-SERIAL permanent line modem allows the
broadband networking of serial devices over in-house lines.
A distance of up to 20 km can lie between two devices.
The SHDSL modem operates transparently of the protocol
and supports RS-232, RS-422 and RS-485 W2 interfaces.
All devices have two SHDSL ports. You can easily set up
point-to-point, redundant point-to-point, line and star topologies.
The clearly visible LEDs on the front of the device provide
on-site technicians with quick device diagnostics. Every device also has integrated diagnosis functions and a logbook.
Two freely configurable digital outputs are available for
alarm generation for external devices. You can parameterize them via the configuration software. Power is supplied
via USB cable, which enables device configuration without
external 24 V power supply.
Areas of application
– For in-house cables
– Point-to-point connection
– Star topology
– Line topology, up to 255 SHDSL devices
SHDSL technology
– Symmetrical data transmission
– Two SHDSL ports
– Up to 15.3 Mbps (2-wire), 30 Mbps (4-wire)
Interfaces
– RS-232, up to 230.4 kbps,
automatic DCE/DTE switchover
– RS-422, up to 2000 kbps
– RS-485 W2, up to 2000 kbps, termination resistor can
be connected
Alarm outputs
– Two digital outputs, individually configurable
Via configuration software:
– Online diagnostics, logbook function
– Individual project configuration
– Saving and printing of project and device configurations
WARNING: Explosion hazard when used in potentially explosive areas
The device is a category 3 item of electrical equipment. Follow the instructions provided here during installation
and observe the safety notes.
A combination of different SHDSL modems (e.g. SHDSL-SERIAL with SHDSL-Ethernet) is not possible.
Make sure you always use the latest documentation.
It can be downloaded at phoenixcontact.net/products.
PSI-MODEM-SHDSL/SERIAL
2
Table of contents
1
Description..................................................................................................................................1
2
Table of contents ........................................................................................................................2
3
Ordering data..............................................................................................................................3
4
Technical data ............................................................................................................................4
5
Safety regulations and installation notes.....................................................................................7
5.1
5.2
5.3
Installation notes ............................................................................................................................................ 7
Installation in zone 2 ...................................................................................................................................... 7
UL notes ......................................................................................................................................................... 7
6
Range .........................................................................................................................................8
7
Application examples..................................................................................................................9
7.1
7.2
7.3
104460_en_04
Point-to-point connection ............................................................................................................................... 9
Linear topology............................................................................................................................................... 9
Star topology .................................................................................................................................................. 9
PHOENIX CONTACT
2/9
PSI-MODEM-SHDSL/SERIAL
3
Ordering data
Description
SHDSL permanent line modem, for point-to-point, line,
and star topologies on in-house 2 and 4-wire cables
Accessories
Description
System power supply,
primary switched
Input voltage range
Nominal output voltage
Nominal output current
DIN rail connector (2x required)
45 Hz ... 65 Hz
85 V AC ... 264 V AC
24 V DC ±1%
1.5 A
Attachment plug with surge protection for two SHDSL
telecommunications interfaces (ports).
Connection: RJ45 (RJ12/RJ11) and plug-in screw terminal
block (COMBICON), can alternatively be snapped onto DIN
rail
USB cable, USB type A/mini-USB type B, 5-pos., 1 m
USB cable, USB type A/mini-USB type B, 5-pos., 3 m
RS-232 cable, for connecting the
D-SUB 9/D-SUB 9
modem to a 9-pos. device interface, (socket/socket)
2m
RS-232 cable, for connecting the
D-SUB 9/D-SUB 9
modem to a 9-pos. device interface, (socket/socket)
0.5 m
Adapter cable to connect the IB IL RS232 and IB IL RS232PRO Inline communication terminals to the interface converter, e.g., modem, Com server, Bluetooth or fiber optics.
104460_en_04
Type
PSI-MODEM-SHDSL/SERIAL
Order No.
2313669
Pcs./Pkt.
1
Type
MINI-SYS-PS-100240AC/24DC/1.5
Order No.
2866983
Pcs./Pkt.
1
ME 17.5 TBUS 1.5/ 5-ST-3.81
GN
DT-TELE-SHDSL
2709561
1
2801593
1
PSI-CA-USB A/MINI B/1METER 2313575
CABLE-USB/MINI-USB-3.0M
2986135
PSM-KA9SUB9/BB/2METER
2799474
1m
3m
2m
PSM-KA9SUB9/BB/0.5METER
2708520
0.5 m
PSM-KAD-IL
RS232/9SUB/B/0.8M
2319200
0.8 m
PHOENIX CONTACT
3/9
PSI-MODEM-SHDSL/SERIAL
4
Technical data
Power supply
Supply voltage
18 V DC ... 30 V DC via plug-in COMBICON screw terminal
block
24 V DC ±5 % (alternative or redundant, via DIN rail connector and system power supply unit)
Nominal current consumption
LED indicator
Switching outputs
5 V DC (configuration only, via mini-USB type B)
< 180 mA at 24 V
VCC (green LED)
– Steady light: operation
– Flashing at 1 Hz: supply via USB (for configuration)
2 x VNom/ 150 mA (the digital outputs cannot be used for
power supply via the DIN rail connector), short-circuit-proof
SHDSL interface
Connection method
Type
Transmission rate
2 x 2-pos. COMBICON plug-in screw terminal block
SHDSL interface according to ITU-T G.991.2.bis
4-wire operation
64 kbps ... 30 Mbps (manual setting of the data rate)
384 kbps ... 11.39 Mbps (automatic detection of the data rate)
2-wire operation
Transmission length
Connection data (conductor cross section)
Status and diagnostics indicators
32 kbps ... 15.3 Mbps (manual setting of the data rate)
192 kbps ... 5.696 Mbps (automatic detection of the data rate)
Over 20 km possible at lower data rates and with good cable
quality
0.2 mm² ... 2.5 mm² (24 - 14 AWG)
2 x LINK, 2 x STAT (DSL data traffic port A and port B)
DIAG (yellow LED), diagnostic messages
ERR (red LED), errors
TERM (yellow LED), only relevant for RS-485
RS232 (yellow LED)
RS-232 interface
Connection method
Type
Transmission rate
Transmission length
Supported protocols
Data format/coding
104460_en_04
D-SUB 9-pos. plug
RS-232 interface, according to ITU-T V.28, EIA/TIA-232,
DIN 66259-1
Can be freely parameterized from 92 bps ... 230.4 kbps
Maximum 15 m
Software handshake (Xon/Xoff), hardware handshake
(RTS/CTS), 3964R-compatible, Modbus RTU/ASCII,
transparent protocol - other protocols supported
Serial asynchronous UART/NRZ, 7/8 data bits, 1/2 stop bits,
1 parity bit (even, odd, mark, space, none),
9/10/11-bit character length
PHOENIX CONTACT
4/9
PSI-MODEM-SHDSL/SERIAL
RS-422 interface
Connection method
Type
Transmission rate
Transmission length
Supported protocols
Data format/coding
RS-485 interface
Connection method
Type
Transmission rate
Transmission length
Supported protocols
Data format/coding
USB interface (configuration/diagnostics)
Connection method
Type
Transmission length
Plug-in/screw connection via COMBICON plug
RS-422 interface, according to ITU-T V.11, EIA/TIA-422,
DIN 66348-1
Can be freely parameterized from 92 bps ... 2 Mbps
Maximum 1200 m
Modbus RTU/ASCII and others, transparent protocol
Serial asynchronous UART/NRZ, 7/8 data bits, 1/2 stop bits,
1 parity bit (even, odd, mark, space, none),
9/10/11-bit character length
Plug-in/screw connection via COMBICON plug
RS-485 interface, according to EIA/TIA-485, DIN 662594/RS-485 2-wire
Can be freely parameterized from 92 bps ... 2 Mbps
Maximum 1200 m
Modbus RTU/ASCII and others, transparent protocol
Serial asynchronous UART/NRZ, 7/8 data bits, 1/2 stop bits,
1 parity bit (even, odd, mark, space, none),
9/10/11-bit character length
Mini-USB type B, 5-pos.
USB 2.0
Maximum 5 m, only for configuration and diagnostics
General data
Ambient temperature range
Operation (no other modules supplied via the device):
-20°C ... +60°C
– Freestanding (40 mm spacing)
– Connected in series (low power dissipation of mod- -20°C ... +55°C
ules connected in series)
– Connected in series (without restrictions)
-20 °C ... +50 °C
Operation (other modules supplied via the device (max.
-20 °C ... +45 °C
1.5 A))
Storage/transport
-40 °C ... +85 °C
Housing
ME 35 with 5-pos. bus contact and ground contact
Material
PA 6.6-FR, V0, green
Dimensions (H x W x D)
99 x 35 x 114.5 mm
Weight
205 g
Functional earth ground
Housing contact to DIN rail
Degree of protection
IP20
Electrical isolation
DIN EN 50178
(Supply // RS-485, RS-422 // DSL port A // DSL port B // FE)
104460_en_04
PHOENIX CONTACT
5/9
PSI-MODEM-SHDSL/SERIAL
General data [...]
SN 29500 standard, temperature 25°C,
operating cycle 21% (5 days a week, 8 hours a day)
SN 29500 standard, temperature 40°C,
operating cycle 34.25% (5 days a week, 12 hours a day)
SN 29500 standard, temperature 40°C,
operating cycle 100% (7 days a week, 24 hours a day)
Test voltage
Vibration resistance
Shock resistance
Noise emission
Noise immunity
Electromagnetic compatibility
UL, USA/Canada
Manufacturer's declaration
693 years
301 years
121 years
1.5 kVrms, 50 Hz, 1 min.
According to IEC 60068-2-6: 5 g, 150 Hz
15g in each space direction, according to IEC 60068-2-27
EN 55011
EN 61000-6-2
Conformity with EMC Directive 2014/30/EU
UL 508 listed
EN 50121-4 (Railway applications - Electromagnetic compatibility, Part 4: Emission and Immunity of the Signaling and
Telecommunications Apparatus)
Exceptions include installations within the 3 m area and
safety-related devices. For these devices, there are further
requirements according to EN 50121-4 Table 1, Note 1.
ATEX
104460_en_04
Section 1, Paragraph 3 of EN 50121-4 applies.
Phoenix Contact QUINT power supply units are to be used
directly on the device.
X II 3 G Ex nA nC IIC T4 Gc X
PHOENIX CONTACT
6/9
PSI-MODEM-SHDSL/SERIAL
5
Safety regulations and installation notes
5.1
Installation notes
5.2
WARNING: Explosion hazard when used
in potentially explosive areas
WARNING:
Observe the following safety notes when using the device.
•
•
•
•
•
•
The category 3 device is designed for installation in
Zone 2 potentially explosive areas. It meets the requirements of EN 60079-0:2012+A11:2013 and
EN 60079-15:2010.
Installation, operation, and maintenance may only be
carried out by qualified electricians. Follow the installation instructions as described. When installing and operating the device, the applicable regulations and
safety directives (including national safety directives),
as well as the general codes of practice, must be observed. The safety data is provided in the packing slip
and on the certificates (conformity assessment, additional approvals where applicable).
Do not open or modify the device. Do not repair the device yourself; replace it with an equivalent device instead. Repairs may only be carried out by the
manufacturer. The manufacturer is not liable for damage resulting from violation.
The IP20 degree of protection (IEC 60529/EN 60529) of
the device is intended for use in a clean and dry environment. Do not subject the device to mechanical
and/or thermal loads that exceed the specified limits.
This device is not designed for use in atmospheres with
a risk of dust explosions.
The device is designed exclusively for operation with
safety extra-low voltage (SELV) according to
IEC 60950/EN 60950/VDE 0805. The device may only
be connected to devices that meet the requirements of
EN 60950.
104460_en_04
Installation in zone 2
Make sure that the following notes and instructions are observed.
•
•
•
•
•
•
•
5.3
Observe the specified conditions for use in potentially
explosive areas!
Install the device in a suitable, approved housing (with
at least IP54 protection) that meets the requirements of
EN 60079-15. For this purpose, observe the requirements of IEC 60079-14 / EN 60079-14.
Only connect devices to the supply and signal circuits in
zone 2 that are suitable for operation in the Ex zone 2
and for the conditions at the installation location.
In potentially explosive areas, snap the device on or off
the DIN rail connector and connect or disconnect the
cables only when the power is disconnected.
The mini-USB configuration interface may only be used
if it has been ensured that there is no explosive atmosphere.
Connection to the D-SUB interface is only permitted if
the screw connection is fully tightened.
The device must be stopped and immediately removed
from the Ex area if it is damaged, was subjected to an
impermissible load, stored incorrectly or if it malfunctions.
UL notes
PHOENIX CONTACT
7/9
PSI-MODEM-SHDSL/SERIAL
6
Range
[Mbps]
The maximum possible SHDSL data rate depends on several parameters. Two important parameters are the cable
length and cable cross section.
16
14
12
10
8
6
4
2
0
= PE 1,4 mm (1,54 mm²)
= PE 0,9 mm (0,64 mm²)
= PE 0,4 mm (0,13 mm²)
0
2
4
6
8
10
12
14
16
18
20
[km]
Figure 1
SHDSL data rate depending on the distance,
2-wire
The diagram illustrates the dependency of the maximum
SHDSL data rate on the line length with 3 cable types. Longer distances can be achieved using high-quality cables
with larger diameters.
The industrial permanent line modems enable data rates in
2-conductor operation from 32 kbps to 15.3 Mbps. Data
rates of up to 30 Mbps are possible in 4-conductor operation.
SHDSL permanent line modems are suitable for in-house
cables, not for public telephone networks.
104460_en_04
PHOENIX CONTACT
8/9
PSI-MODEM-SHDSL/SERIAL
7
Application examples
For more information, please refer to the UM EN
PSI-MODEM-SHDSL/SERIAL user manual.
7.3
Point-to-point connection
RS 485
B
...
E
SHDSL
SHDSL
RS 232
RS 422
RS 485
RS 232
RS 422
RS 485
SHDSL
A
SHDSL
SHDSL 4 Wire
SHDSL
RS 232
RS 422
RS 485
SHDSL
RS 232
RS 422
RS 485
SHDSL
B
...
SHDSL
SHDSL 2 Wire
Star topology
SHDSL
SHDSL
7.1
C
RS 485 RS 485 RS 485 RS 485
A
C
D
F
A
7.2
B
SHDSL
SHDSL
SHDSL
Line 1
C
Linear topology
RS 232
RS 422
RS 485
RS 232
RS 422
RS 485
RS 232
RS 422
RS 485
Atypical application cases are also supported, e.g. the linear
topology of multiple RS-232 interfaces or a mixed operation
using different interfaces. The customer does, however,
then need his custom protocol. The SHDSL modem transmits the data protocol transparently.
104460_en_04
SHDSL
SHDSL
SHDSL
SHDSL
SHDSL
SHDSL
Line 2
D
E
F
The devices are connected via the DIN rail connector
(TBUS) in the head station. The DIN rail connector supports
RS-485. It can only be used with RS-232 and RS-422.
In order to configure a star topology, you must create several line topologies. In the example, you have to create two
linear topologies each comprising three devices.
PHOENIX CONTACT GmbH & Co. KG • Flachsmarktstraße 8 • 32825 Blomberg • Germany
phoenixcontact.com
9/9