0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2313669

2313669

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    SHDSL MODEM RS232/422/485

  • 数据手册
  • 价格&库存
2313669 数据手册
PSI-MODEM-SHDSL/SERIAL SHDSL-SERIAL permanent line modem Data sheet 104460_en_04 1 © PHOENIX CONTACT 2016-07-14 Description The SHDSL-SERIAL permanent line modem allows the broadband networking of serial devices over in-house lines. A distance of up to 20 km can lie between two devices. The SHDSL modem operates transparently of the protocol and supports RS-232, RS-422 and RS-485 W2 interfaces. All devices have two SHDSL ports. You can easily set up point-to-point, redundant point-to-point, line and star topologies. The clearly visible LEDs on the front of the device provide on-site technicians with quick device diagnostics. Every device also has integrated diagnosis functions and a logbook. Two freely configurable digital outputs are available for alarm generation for external devices. You can parameterize them via the configuration software. Power is supplied via USB cable, which enables device configuration without external 24 V power supply. Areas of application – For in-house cables – Point-to-point connection – Star topology – Line topology, up to 255 SHDSL devices SHDSL technology – Symmetrical data transmission – Two SHDSL ports – Up to 15.3 Mbps (2-wire), 30 Mbps (4-wire) Interfaces – RS-232, up to 230.4 kbps, automatic DCE/DTE switchover – RS-422, up to 2000 kbps – RS-485 W2, up to 2000 kbps, termination resistor can be connected Alarm outputs – Two digital outputs, individually configurable Via configuration software: – Online diagnostics, logbook function – Individual project configuration – Saving and printing of project and device configurations WARNING: Explosion hazard when used in potentially explosive areas The device is a category 3 item of electrical equipment. Follow the instructions provided here during installation and observe the safety notes. A combination of different SHDSL modems (e.g. SHDSL-SERIAL with SHDSL-Ethernet) is not possible. Make sure you always use the latest documentation. It can be downloaded at phoenixcontact.net/products. PSI-MODEM-SHDSL/SERIAL 2 Table of contents 1 Description..................................................................................................................................1 2 Table of contents ........................................................................................................................2 3 Ordering data..............................................................................................................................3 4 Technical data ............................................................................................................................4 5 Safety regulations and installation notes.....................................................................................7 5.1 5.2 5.3 Installation notes ............................................................................................................................................ 7 Installation in zone 2 ...................................................................................................................................... 7 UL notes ......................................................................................................................................................... 7 6 Range .........................................................................................................................................8 7 Application examples..................................................................................................................9 7.1 7.2 7.3 104460_en_04 Point-to-point connection ............................................................................................................................... 9 Linear topology............................................................................................................................................... 9 Star topology .................................................................................................................................................. 9 PHOENIX CONTACT 2/9 PSI-MODEM-SHDSL/SERIAL 3 Ordering data Description SHDSL permanent line modem, for point-to-point, line, and star topologies on in-house 2 and 4-wire cables Accessories Description System power supply, primary switched Input voltage range Nominal output voltage Nominal output current DIN rail connector (2x required) 45 Hz ... 65 Hz 85 V AC ... 264 V AC 24 V DC ±1% 1.5 A Attachment plug with surge protection for two SHDSL telecommunications interfaces (ports). Connection: RJ45 (RJ12/RJ11) and plug-in screw terminal block (COMBICON), can alternatively be snapped onto DIN rail USB cable, USB type A/mini-USB type B, 5-pos., 1 m USB cable, USB type A/mini-USB type B, 5-pos., 3 m RS-232 cable, for connecting the D-SUB 9/D-SUB 9 modem to a 9-pos. device interface, (socket/socket) 2m RS-232 cable, for connecting the D-SUB 9/D-SUB 9 modem to a 9-pos. device interface, (socket/socket) 0.5 m Adapter cable to connect the IB IL RS232 and IB IL RS232PRO Inline communication terminals to the interface converter, e.g., modem, Com server, Bluetooth or fiber optics. 104460_en_04 Type PSI-MODEM-SHDSL/SERIAL Order No. 2313669 Pcs./Pkt. 1 Type MINI-SYS-PS-100240AC/24DC/1.5 Order No. 2866983 Pcs./Pkt. 1 ME 17.5 TBUS 1.5/ 5-ST-3.81 GN DT-TELE-SHDSL 2709561 1 2801593 1 PSI-CA-USB A/MINI B/1METER 2313575 CABLE-USB/MINI-USB-3.0M 2986135 PSM-KA9SUB9/BB/2METER 2799474 1m 3m 2m PSM-KA9SUB9/BB/0.5METER 2708520 0.5 m PSM-KAD-IL RS232/9SUB/B/0.8M 2319200 0.8 m PHOENIX CONTACT 3/9 PSI-MODEM-SHDSL/SERIAL 4 Technical data Power supply Supply voltage 18 V DC ... 30 V DC via plug-in COMBICON screw terminal block 24 V DC ±5 % (alternative or redundant, via DIN rail connector and system power supply unit) Nominal current consumption LED indicator Switching outputs 5 V DC (configuration only, via mini-USB type B) < 180 mA at 24 V VCC (green LED) – Steady light: operation – Flashing at 1 Hz: supply via USB (for configuration) 2 x VNom/ 150 mA (the digital outputs cannot be used for power supply via the DIN rail connector), short-circuit-proof SHDSL interface Connection method Type Transmission rate 2 x 2-pos. COMBICON plug-in screw terminal block SHDSL interface according to ITU-T G.991.2.bis 4-wire operation 64 kbps ... 30 Mbps (manual setting of the data rate) 384 kbps ... 11.39 Mbps (automatic detection of the data rate) 2-wire operation Transmission length Connection data (conductor cross section) Status and diagnostics indicators 32 kbps ... 15.3 Mbps (manual setting of the data rate) 192 kbps ... 5.696 Mbps (automatic detection of the data rate) Over 20 km possible at lower data rates and with good cable quality 0.2 mm² ... 2.5 mm² (24 - 14 AWG) 2 x LINK, 2 x STAT (DSL data traffic port A and port B) DIAG (yellow LED), diagnostic messages ERR (red LED), errors TERM (yellow LED), only relevant for RS-485 RS232 (yellow LED) RS-232 interface Connection method Type Transmission rate Transmission length Supported protocols Data format/coding 104460_en_04 D-SUB 9-pos. plug RS-232 interface, according to ITU-T V.28, EIA/TIA-232, DIN 66259-1 Can be freely parameterized from 92 bps ... 230.4 kbps Maximum 15 m Software handshake (Xon/Xoff), hardware handshake (RTS/CTS), 3964R-compatible, Modbus RTU/ASCII, transparent protocol - other protocols supported Serial asynchronous UART/NRZ, 7/8 data bits, 1/2 stop bits, 1 parity bit (even, odd, mark, space, none), 9/10/11-bit character length PHOENIX CONTACT 4/9 PSI-MODEM-SHDSL/SERIAL RS-422 interface Connection method Type Transmission rate Transmission length Supported protocols Data format/coding RS-485 interface Connection method Type Transmission rate Transmission length Supported protocols Data format/coding USB interface (configuration/diagnostics) Connection method Type Transmission length Plug-in/screw connection via COMBICON plug RS-422 interface, according to ITU-T V.11, EIA/TIA-422, DIN 66348-1 Can be freely parameterized from 92 bps ... 2 Mbps Maximum 1200 m Modbus RTU/ASCII and others, transparent protocol Serial asynchronous UART/NRZ, 7/8 data bits, 1/2 stop bits, 1 parity bit (even, odd, mark, space, none), 9/10/11-bit character length Plug-in/screw connection via COMBICON plug RS-485 interface, according to EIA/TIA-485, DIN 662594/RS-485 2-wire Can be freely parameterized from 92 bps ... 2 Mbps Maximum 1200 m Modbus RTU/ASCII and others, transparent protocol Serial asynchronous UART/NRZ, 7/8 data bits, 1/2 stop bits, 1 parity bit (even, odd, mark, space, none), 9/10/11-bit character length Mini-USB type B, 5-pos. USB 2.0 Maximum 5 m, only for configuration and diagnostics General data Ambient temperature range Operation (no other modules supplied via the device): -20°C ... +60°C – Freestanding (40 mm spacing) – Connected in series (low power dissipation of mod- -20°C ... +55°C ules connected in series) – Connected in series (without restrictions) -20 °C ... +50 °C Operation (other modules supplied via the device (max. -20 °C ... +45 °C 1.5 A)) Storage/transport -40 °C ... +85 °C Housing ME 35 with 5-pos. bus contact and ground contact Material PA 6.6-FR, V0, green Dimensions (H x W x D) 99 x 35 x 114.5 mm Weight 205 g Functional earth ground Housing contact to DIN rail Degree of protection IP20 Electrical isolation DIN EN 50178 (Supply // RS-485, RS-422 // DSL port A // DSL port B // FE) 104460_en_04 PHOENIX CONTACT 5/9 PSI-MODEM-SHDSL/SERIAL General data [...] SN 29500 standard, temperature 25°C, operating cycle 21% (5 days a week, 8 hours a day) SN 29500 standard, temperature 40°C, operating cycle 34.25% (5 days a week, 12 hours a day) SN 29500 standard, temperature 40°C, operating cycle 100% (7 days a week, 24 hours a day) Test voltage Vibration resistance Shock resistance Noise emission Noise immunity Electromagnetic compatibility UL, USA/Canada Manufacturer's declaration 693 years 301 years 121 years 1.5 kVrms, 50 Hz, 1 min. According to IEC 60068-2-6: 5 g, 150 Hz 15g in each space direction, according to IEC 60068-2-27 EN 55011 EN 61000-6-2 Conformity with EMC Directive 2014/30/EU UL 508 listed EN 50121-4 (Railway applications - Electromagnetic compatibility, Part 4: Emission and Immunity of the Signaling and Telecommunications Apparatus) Exceptions include installations within the 3 m area and safety-related devices. For these devices, there are further requirements according to EN 50121-4 Table 1, Note 1. ATEX 104460_en_04 Section 1, Paragraph 3 of EN 50121-4 applies. Phoenix Contact QUINT power supply units are to be used directly on the device. X II 3 G Ex nA nC IIC T4 Gc X PHOENIX CONTACT 6/9 PSI-MODEM-SHDSL/SERIAL 5 Safety regulations and installation notes 5.1 Installation notes 5.2 WARNING: Explosion hazard when used in potentially explosive areas WARNING: Observe the following safety notes when using the device. • • • • • • The category 3 device is designed for installation in Zone 2 potentially explosive areas. It meets the requirements of EN 60079-0:2012+A11:2013 and EN 60079-15:2010. Installation, operation, and maintenance may only be carried out by qualified electricians. Follow the installation instructions as described. When installing and operating the device, the applicable regulations and safety directives (including national safety directives), as well as the general codes of practice, must be observed. The safety data is provided in the packing slip and on the certificates (conformity assessment, additional approvals where applicable). Do not open or modify the device. Do not repair the device yourself; replace it with an equivalent device instead. Repairs may only be carried out by the manufacturer. The manufacturer is not liable for damage resulting from violation. The IP20 degree of protection (IEC 60529/EN 60529) of the device is intended for use in a clean and dry environment. Do not subject the device to mechanical and/or thermal loads that exceed the specified limits. This device is not designed for use in atmospheres with a risk of dust explosions. The device is designed exclusively for operation with safety extra-low voltage (SELV) according to IEC 60950/EN 60950/VDE 0805. The device may only be connected to devices that meet the requirements of EN 60950. 104460_en_04 Installation in zone 2 Make sure that the following notes and instructions are observed. • • • • • • • 5.3 Observe the specified conditions for use in potentially explosive areas! Install the device in a suitable, approved housing (with at least IP54 protection) that meets the requirements of EN 60079-15. For this purpose, observe the requirements of IEC 60079-14 / EN 60079-14. Only connect devices to the supply and signal circuits in zone 2 that are suitable for operation in the Ex zone 2 and for the conditions at the installation location. In potentially explosive areas, snap the device on or off the DIN rail connector and connect or disconnect the cables only when the power is disconnected. The mini-USB configuration interface may only be used if it has been ensured that there is no explosive atmosphere. Connection to the D-SUB interface is only permitted if the screw connection is fully tightened. The device must be stopped and immediately removed from the Ex area if it is damaged, was subjected to an impermissible load, stored incorrectly or if it malfunctions. UL notes PHOENIX CONTACT 7/9 PSI-MODEM-SHDSL/SERIAL 6 Range [Mbps] The maximum possible SHDSL data rate depends on several parameters. Two important parameters are the cable length and cable cross section. 16 14 12 10 8 6 4 2 0 = PE 1,4 mm (1,54 mm²) = PE 0,9 mm (0,64 mm²) = PE 0,4 mm (0,13 mm²) 0 2 4 6 8 10 12 14 16 18 20 [km] Figure 1 SHDSL data rate depending on the distance, 2-wire The diagram illustrates the dependency of the maximum SHDSL data rate on the line length with 3 cable types. Longer distances can be achieved using high-quality cables with larger diameters. The industrial permanent line modems enable data rates in 2-conductor operation from 32 kbps to 15.3 Mbps. Data rates of up to 30 Mbps are possible in 4-conductor operation. SHDSL permanent line modems are suitable for in-house cables, not for public telephone networks. 104460_en_04 PHOENIX CONTACT 8/9 PSI-MODEM-SHDSL/SERIAL 7 Application examples For more information, please refer to the UM EN PSI-MODEM-SHDSL/SERIAL user manual. 7.3 Point-to-point connection RS 485 B ... E SHDSL SHDSL RS 232 RS 422 RS 485 RS 232 RS 422 RS 485 SHDSL A SHDSL SHDSL 4 Wire SHDSL RS 232 RS 422 RS 485 SHDSL RS 232 RS 422 RS 485 SHDSL B ... SHDSL SHDSL 2 Wire Star topology SHDSL SHDSL 7.1 C RS 485 RS 485 RS 485 RS 485 A C D F A 7.2 B SHDSL SHDSL SHDSL Line 1 C Linear topology RS 232 RS 422 RS 485 RS 232 RS 422 RS 485 RS 232 RS 422 RS 485 Atypical application cases are also supported, e.g. the linear topology of multiple RS-232 interfaces or a mixed operation using different interfaces. The customer does, however, then need his custom protocol. The SHDSL modem transmits the data protocol transparently. 104460_en_04 SHDSL SHDSL SHDSL SHDSL SHDSL SHDSL Line 2 D E F The devices are connected via the DIN rail connector (TBUS) in the head station. The DIN rail connector supports RS-485. It can only be used with RS-232 and RS-422. In order to configure a star topology, you must create several line topologies. In the example, you have to create two linear topologies each comprising three devices. PHOENIX CONTACT GmbH & Co. KG • Flachsmarktstraße 8 • 32825 Blomberg • Germany phoenixcontact.com 9/9
2313669 价格&库存

很抱歉,暂时无法提供与“2313669”相匹配的价格&库存,您可以联系我们找货

免费人工找货