0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2701664

2701664

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    WIRELESS ELEMENTS

  • 数据手册
  • 价格&库存
2701664 数据手册
PSD-S WIN MA/UL Master with antenna for the WIN signal tower wireless system Data sheet 8642_en_00 1 © PHOENIX CONTACT 2013-02-04 Description The WIN (Wireless Information Network) wireless system is an inexpensive, wireless-based machine data acquisition system (MDA system). WIN master features – – It enables wireless transmission of signal statuses from several signal towers and therefore central monitoring on the PC – of up to 50 different machines. Use of the 915 MHz frequency band Can operated parallel to other wireless applications (e. g., WLAN, Bluetooth) Simultaneous detection of up to 50 wireless elements (slaves) A master as receiving unit, at least one slave as wireless element and software for displaying and evaluating the signal WIN software features statuses make up the wireless system. – License-free software for wireless monitoring of the maThe following is included in scope of supply: chine park on the PC at a glance – One master with antenna including accessories – Scope of functions: monitoring of system statuses, trou– One USB cable bleshooting, wireless path diagnostics, productivity anal– Software CD with WIN software ysis for increasing machine efficiency and availability, storing in a database The master is the receiving unit for the signals that are trans– Easy installation mitted by the slave. The master is connected to the USB connection of a PC. You – No programming knowledge required can therefore display and evaluate received signal statuses – Error messages from the software can be sent via e-mail with the WIN software on the PC and store them in a database. NOTE: This version of WIN is only approved for use in North America. NOTE: Do not use the WIN system for safety-related applications! Make sure you always use the latest documentation. It can be downloaded from the product at www.phoenixcontact.net/products. PSD-S WIN MA/UL 2 Table of contents 1 Description .............................................................................................................................. 1 2 Table of contents ..................................................................................................................... 2 3 Ordering data .......................................................................................................................... 2 4 Technical data ......................................................................................................................... 3 5 Scope of supply ....................................................................................................................... 4 6 Use limitation ........................................................................................................................... 5 6.1 FCC approval ..................................................................................................................... 5 6.2 IC approval ........................................................................................................................ 5 7 Safety notes............................................................................................................................. 5 8 Mounting the master ................................................................................................................ 6 9 Master supply voltage.............................................................................................................. 6 10 Diagnostics.............................................................................................................................. 6 11 WIN software ........................................................................................................................... 6 3 Ordering data Description Order No. Pcs. / Pkt. Master with antenna for the WIN signal tower wireless system, with USB in- PSD-S WIN MA/UL terface, voltage supply via USB interface, software CD, USB cable (3 m), four rubber feet and material for wall mounting of the master 2701664 1 Additional product required Type Order No. Pcs. / Pkt. Slave with C-UL-US approval for creating or extending the WIN signal tower wireless system, 24 V AC/DC, black PSD-S WIN SL/UL 2701565 1 Set comprises Type Order No. Pcs. / Pkt. Set with C-UL-US approval for the WIN signal tower wireless system, con- PSD-S WIN SET-1MA-3SL/UL sisting of one master with antenna, three slaves, software CD, USB cable (3 m), four rubber feet, and mounting material for wall mounting the master 2701563 1 Starter kit with C-UL-US approval for the WIN signal tower wireless system, PSD-S WIN STARTERKIT/UL consisting of one master with antenna, three slaves, nine LED permanent light elements (red, yellow, green), three connection elements, three mounting feet with integrated tube, software CD, USB cable (3 m), four rubber feet, and mounting material for wall mounting the master 2701564 1 Documentation Type Order No. Pcs. / Pkt. User manual, German, wireless system for signal towers, only approved for use in North America! UM DE PSD-S WIN/UL - - User manual, English, wireless system for signal towers, only approved for use in North America! UM EN PSD-S WIN/UL - - User manual, French, wireless system for signal towers, only approved for use in North America! UM FR PSD-S WIN/UL - - 8642_en_00 Type PHOENIX CONTACT 2 PSD-S WIN MA/UL 4 Technical data 17 42 Dimensions (in mm) 15 77 80 3,5 30,5 188 34 117 Width 77 mm Height 188 mm Depth 117 mm Note on dimensions Height and depth when antenna is perpendicular General data Material Acrylonitrile butadiene styrene (ABS) Color black Weight 106 g Ambient temperature (operation) -20 °C ... 50 °C Degree of protection IP20 Diagnostics / Message Wireless connection / LED Electrical data of the master Interfaces USB Operating voltage 5 V DC (USB; only use USB cables with a maximum length of 3 m.) Inrush current 100 mA Current consumption max. 100 mA Wireless interface Modulation type 2 FSK Frequency range 913 Hz ... 917 Hz Frequency band 915 MHz ISM band Transmission power 10 dBm (at 50 Ohm) Range 300 m, maximum Transmission speed 38.4 kbps (can be adjusted via WIN software) , 76.8 kbps (default) Wireless modules that can be connected Up to 50 (2701565 PSD-S WIN SL/UL) 8642_en_00 PHOENIX CONTACT 3 PSD-S WIN MA/UL Approvals / conformities Conforms with guidelines: FCC Part 15.249/IC: RSS-210 Issue 8, RSS-GEN Issue 4, RSS-102 Issue 4 For the latest approvals, please visit www.phoenixcontact.net/products. Wireless licences Country ID 5 USA , Canada Scope of supply Figure 1 Elements within the scope of supply Key: 1 Master 2 USB cable 3 CD with WIN software 4 Fixing element 1 (screw to master; two screws included) 5 Fixing element 2 (screw to the wall) 6 Rubber feet 8642_en_00 PHOENIX CONTACT 4 PSD-S WIN MA/UL 6 6.1 Use limitation 7 NOTE: CAUTION: This version of WIN is only approved for use in North America. Observe the following safety notes when using the WIN wireless system! FCC approval – – FCC = Federal Communications Commission This device complies with Part 15 of the FCC regulations. Operation is subject to the following two requirements: – 1. This device may not cause harmful disturbances. – 2. This device must withstand all disturbances received, in– cluding disturbances which could lead to unintentional operation. – Normally, the following FCC warning applies: The user's permission to operate the equipment could be de– clared void by making any changes or modifications to this unit which are not expressly approved by the party responsible for compliance. – Contains: transmitter module FCC ID: ZGHWIN1 6.2 Safety notes IC approval – This device complies with the RSS rule(s) of Industry Canada. Operation is subject to the following two requirements: – 1. This device may not cause harmful disturbances. 2. This device must withstand all disturbances received, including disturbances which could lead to unintentional operation. Do not use the system for safety-related applications. Also please observe the documentation on the individual elements of the signal tower (data sheets, package inserts) and the user manual regarding the wireless system for signal towers. Use only with 24 V signal towers. Only a qualified electrician can connect the system. Only use power supply units with safe isolation and PELV voltage (protection class 2). This device does not replace personal protective equipment (e.g., protective goggles, foot protection, etc.). This system cannot eliminate the need for or replace protective machine equipment, a safety circuit, a protective device, a safety regulation or supervision. Test this device and all protective machine equipment and safety devices at the start of each shift to ensure that it is functioning correctly. Always take the machines out of operation when replacing worn parts. When guards are removed, always implement the “OSHA lock-out/tag-out” regulations. Contains: transmitter module IC: 9619A-WIN1 8642_en_00 PHOENIX CONTACT 5 PSD-S WIN MA/UL 8 Mounting the master The ideal wireless connection is achieved when as few objects as possible influence the WIN master and WIN slave. 9 Master supply voltage The WIN master is supplied with voltage from the PC connected to it via the USB connection of the PC. 10 Diagnostics You can mount the master either on the wall or position it next The status of the wireless connection is indicated by the LED to the PC. band that surrounds the master. If you do not mount the master on the wall, stick the four rubber feet provided to the four corners on the underside of the Meaning Red LED Green LED master. They serve to protect against scratching and slipping. No wireless connection to the WIN X slave If you mount the master on the wall, proceed as follows. Wireless connection to at least X one WIN slave 11 A WIN software Please obtain information on the WIN software from the corresponding User Manual. C B Figure 2 • • • Mounting the master on the wall Screw the fixing element 1 to the master (fig. A). Use the screws supplied. Screw the fixing element 2 to the wall (fig. B). The screws are not supplied. Snap the master with fixing element 1 into fixing element 2 (fig. C). 8642_en_00 PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany www.phoenixcontact.com 6
2701664 价格&库存

很抱歉,暂时无法提供与“2701664”相匹配的价格&库存,您可以联系我们找货

免费人工找货