  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    -

  • 描述:

    ANALOG OUTPUT TERMINAL BLOCK

  • 数据手册
  • 价格&库存
2726298 数据手册
Extract from the online catalog     IB IL AO 1/SF Order No.: 2726298 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2726298   Inline analog output terminal, without accessories, 1 output, 0-20 mA, 4-20 mA, 0-10 V, 2-wire connection method   Product notes WEEE/RoHS-compliant since: 07/09/2007 Commercial data GTIN (EAN) 4 017918 168131 sales group K412 Pack 1 pcs. Customs tariff 85389091 Catalog page information Page 80 (AX-2007) http:// www.download.phoenixcontact.com Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation. The General Terms and Conditions of Use apply to Internet downloads. Product description The analog Inline output terminals are used in applications in which analog actuators are to be addressed. With these terminals, common current and voltage output ranges can be configured individually. The analog signals are made available with a resolution of 16 bits. It goes without saying that you also have advantages in handling with the analog Inline output terminals, such as multiwire connection or the automatic contact with the grounding conductor when the terminal is snapped onto the DIN rail. The Inline terminals can be labeled using hinged labeling fields. The fields have insert cards that can be labeled individually to suit the application. Additionally, there is the proven ZBFM-6... Zack strip for labeling the terminal points. PHOENIX CONTACT Inc., USA http://www.phoenixcon.com Page 1 / 6 Feb 7, 2011 IB IL AO 1/SF Order No.: 2726298 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2726298 Technical data General data Width 24.4 mm Height 119.8 mm Depth 71.5 mm Weight 46 g Mounting type DIN rail Ambient temperature (operation) -25 °C ... 55 °C Ambient temperature (storage/transport) -25 °C ... 85 °C Permissible humidity (operation) 10 % ... 95 % (according to DIN EN 61131-2) Permissible humidity (storage/transport) 10 % ... 95 % (according to DIN EN 61131-2) Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level) Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level) Degree of protection IP20 Protection class III, IEC 61140, EN 61140, VDE 0140-1 Test section 7.5 V supply (bus logic), 24 V supply UANA / I/O 500 V AC 50 Hz 1 min 7.5 V supply (bus logic), 24 V supply UANA/functional earth ground 500 V AC 50 Hz 1 min 24 V supply (I/O) / functional earth ground 500 V AC 50 Hz 1 min Interface Name Inline local bus Type of connection Inline data jumper Transmission speed 500 kbps 500 kBit/s Transmission physics Copper Inline potential routing Communications power UL 7.5 V DC (via voltage jumper) Current consumption from UL max. 40 mA Typ. 30 mA I/O supply voltage UANA 24 V DC Current consumption from UANA max. 65 mA Typ. 50 mA PHOENIX CONTACT Inc., USA http://www.phoenixcon.com Page 2 / 6 Feb 7, 2011 IB IL AO 1/SF Order No.: 2726298 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2726298 Analog outputs Number of outputs 1 Connection method 2-wire (shielded) Output name Analog outputs D/A conversion time < 100 µs D/A resolution 16 Bit Type of protection Transient protection of outputs Measured value representation 16 bits (15 bits + sign bit) DAC resolution 16 Bit Process data update < 1 ms Current output signal 0 mA ... 20 mA 4 mA ... 20 mA Load/output load current output > 500 Ω Voltage output signal 0 V ... 10 V Load/output load voltage output > 2 kΩ 0.05 % Precision Typ. 0.8 % (of output range final value) Typ. 0.5 % (of output range final value) Certificates / Approvals Certification CUL, GOST, UL Certification Ex: CUL-EX, PxC-EX, UL-EX LIS Accessories Item Designation Description 1051993 B-STIFT Marker pen, for manual labeling of unprinted Zack strips, smearproof and waterproof, line thickness 0.5 mm 0809492 ESL 62X10 Insert strip for laser printer, lettering field: 62 x 10 mm 2727501 IB IL FIELD 2 Labeling field, width: 12.2 mm Marking PHOENIX CONTACT Inc., USA http://www.phoenixcon.com Page 3 / 6 Feb 7, 2011 IB IL AO 1/SF Order No.: 2726298 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2726298 0811228 X-PEN 0,35 Marker pen without ink cartridge, for manual labeling of markers, labeling extremely wipe-proof, line thickness 0.35 mm 0808778 ZBF 6:SO/CMS Zack strip, flat, 10-section, divisible, special printing, marking according to customer requirements 0808710 ZBF 6:UNBEDRUCKT Zack strip, flat, unprinted: 10-section, for individual labeling with M-PEN or ZBF-T, sufficient for 100 terminal blocks, color: white 0803618 ZBFM 6/WH:UNBEDRUCKT Zack marker sheet, flat, unprinted: 100-section, 10 strips à 10 markers, sufficient for 100 terminal blocks, for all terminal blocks, pitch 6.2 mm, labeling with M-PEN or CMS system, color: white 0803650 ZBFM 6:SO/CMS Special printing, Zack marker sheet, flat, 100-section, divisible, marking according to customer requirements 2732664 IB IL AO/CNT-PLSET Connector set 2726353 IB IL SCN-6 SHIELD Inline shield connector 2726337 IB IL SCN-8 Connector, for digital 1, 2 or 8-channel Inline terminals 2727608 IB IL SCN-8-CP Inline connector, colored Plug/Adapter Diagrams/Drawings Connection diagram PHOENIX CONTACT Inc., USA http://www.phoenixcon.com Page 4 / 6 Feb 7, 2011 IB IL AO 1/SF Order No.: 2726298 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2726298 Block diagram Dimensioned drawing FAQs • How many and which I/O connectors have to be used to connect the analog conductor for the Inline terminal IB IL AO 1/SF? Two connectors must be used, since this terminal is a double terminal (24.4 mm wide). The available channel can be used as either voltage or current output. In order to connect an analog conductor, an Inline shield connector (IB IL SCN-6-SHIELD, Order no. 2726353) must be used and snapped into the left (voltage output) or right slot (current output) to suit the application. One free slot is always left over and this must be occupied by another connector. We recommend using a standard Inline connector without shield (IB IL SCN-8, Order no. 2726337). The connector versions necessary are in the connector set IB IL AO/CNT-PLSET (Order no. 2732664). • Output behavior of the analog output terminals after a bus error The output behavior of the Inline analog terminals after a bus error is different from the standard behavior of familiar INTERBUS analog modules. An interruption in the bus within a particular time window can lead to an undefined output behavior. In this case, it is not possible to clearly determine whether the outputs return to zero, or whether the old value is retained. PHOENIX CONTACT Inc., USA http://www.phoenixcon.com Page 5 / 6 Feb 7, 2011 IB IL AO 1/SF Order No.: 2726298 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2726298 Address PHOENIX CONTACT Inc., USA 586 Fulling Mill Road Middletown, PA 17057,USA Phone (800) 888-7388 Fax (717) 944-1625 http://www.phoenixcon.com © 2011 Phoenix Contact Technical modifications reserved; PHOENIX CONTACT Inc., USA http://www.phoenixcon.com Page 6 / 6 Feb 7, 2011
2726298 价格&库存

很抱歉,暂时无法提供与“2726298”相匹配的价格&库存,您可以联系我们找货

免费人工找货