MINI MCR-SL-PTB-FM Power terminal block Data sheet 105449_en_00 1 © PHOENIX CONTACT 2013-02-18 Description The MINI MCR-SL-PTB-FM(-SP) power terminal is used to supply the supply voltage to the DIN rail connector. Features – Two separate voltage inputs allow for redundant voltage sup- – ply, which is decoupled from diodes, up to a maximum current of 2 A. Approval for Ex-zone 2 (nA) Screw or spring-cage connection can be provided The MINI MCR-SL-PTB-FM(-SP) power terminal provides the following functions: – Monitoring in conjunction with the MINI MCR-SL-FMRC-NC fault monitoring module (Order No. 2902961) or MINI MCR-SL-FM-RC-SP-NC (Order No. 2902962) – Flexible redundant supply from one or both module sides – Extended supply voltage range from 0...30 V DC WARNING: Correct usage in potentially explosive areas The module is a category 3 item of electrical equipment. It is absolutely vital to follow the instructions provided here during installation and observe the information in the "Safety regulations and installation notes". Make sure you always use the latest documentation. It can be downloaded from the product at www.phoenixcontact.net/products. This data sheet is valid for all products listed on the following page: MINI MCR-SL-PTB-FM 2 Table of contents 1 Description .............................................................................................................................. 1 2 Table of contents ..................................................................................................................... 2 3 Ordering data .......................................................................................................................... 3 4 Technical data ......................................................................................................................... 4 5 Safety regulations and installation notes.................................................................................. 5 5.1 Installation notes ................................................................................................................. 5 5.2 Installation in the Ex area (zone 2)............................................................................................ 5 6 Installation ............................................................................................................................... 6 6.1 Connection notes ................................................................................................................ 6 6.2 Structure ........................................................................................................................... 6 6.3 Block diagram ..................................................................................................................... 6 6.4 Power supply ...................................................................................................................... 6 6.5 Use in the MINI Analog system................................................................................................ 6 6.6 Assembly........................................................................................................................... 7 6.7 Connecting the wires ............................................................................................................ 7 7 Fault monitoring FM................................................................................................................. 8 7.1 Fault monitoring for group error detection .................................................................................. 8 7.2 Fault monitoring for redundancy monitoring ................................................................................ 8 8 Diagnostic indicator ................................................................................................................. 8 105449_en_00 PHOENIX CONTACT 2 MINI MCR-SL-PTB-FM 3 Ordering data Description Type Order No. Pcs. / Pkt. The MINI MCR-SL-PTB-FM(-SP) power terminal block is used to supply the supply voltage to the T-connector. The FM power terminal block offers the additional function of monitoring in combination with the fault monitoring module. Screw connection. MINI MCR-SL-PTB-FM 2902958 1 The MINI MCR-SL-PTB-FM(-SP) power terminal block is used to supply the supply voltage to the T-connector. The FM power terminal block offers the additional function of monitoring in combination with the fault monitoring module. Spring-cage connection. MINI MCR-SL-PTB-FM-SP 2902959 1 Accessories Type Order No. Pcs. / Pkt. The fault monitoring module is used to evaluate and report group errors from the fault monitoring system and to monitor the supply voltages. The error is reported via an N/O contact. Screw connection, standard configuration. MINI MCR-SL-FM-RC-NC 2902961 1 The fault monitoring module is used to evaluate and report group errors from the fault monitoring system and to monitor the supply voltages. The error is reported via an N/O contact. Spring-cage connection, standard configuration. MINI MCR-SL-FM-RC-SP-NC 2902962 1 DIN rail connector (TBUS), 5-pos., for bridging the supply voltage, can be snapped onto NS 35/... DIN rails according to EN 60715 ME 6,2 TBUS-2 1,5/5-ST-3,81 GN 2869728 10 Fold up transparent cover for MINI MCR modules with additional labeling option using insert strips and flat Zack marker strip 6.2 mm MINI MCR DKL 2308111 10 Label for extended marking of MINI MCR modules in connection with the MINI MCR-DKL MINI MCR-DKL-LABEL 2810272 10 105449_en_00 PHOENIX CONTACT 3 MINI MCR-SL-PTB-FM 4 Technical data Input Input voltage 0 V DC ... 30 V DC Max. input current 2A Protection against polarity reversal Yes Output Output voltage (Input voltage - 0.8 V) Output current ≤2A Diagnostic and status indicators Status display Green LED (supply) Indication Red LED General data Maximum temperature coefficient < 0.01 %/K Mounting position Any Degree of protection IP20 Dimensions W / H / D 6.2 mm / 93.1 mm / 102.5 mm Type of housing PBT green Connection data Screw connection Spring-cage conn. Conductor cross section, solid 0.2 mm² ... 2.5 mm² 0.2 mm² ... 2.5 mm² Conductor cross section, stranded 0.2 mm² ... 2.5 mm² 0.2 mm² ... 2.5 mm² Stripping length 12 mm 8 mm Ambient conditions Ambient temperature (operation) -20 °C ... 65 °C Ambient temperature (storage/transport) -40 °C ... 85 °C Conformance with EMC Directive 2004/108/EC Noise immunity according to EN 61000-6-2 When being exposed to interference, there may be minimal deviations. Noise emission according to EN 61000-6-4 Conformance / approvals Conformance CE-compliant ATEX  II 3 G Ex nA IIC T4 Gc X UL, USA / Canada UL 508 Recognized applied for UL, USA / Canada Class I, Div. 2, Groups A, B, C, D T5 applied for Shipbuilding GL applied for 105449_en_00 PHOENIX CONTACT 4 MINI MCR-SL-PTB-FM 5 Safety regulations and installation notes 5.1 Installation notes – – – – – The category 3 device is suitable for installation in the zone 2 potentially explosive area. It fulfills the requirements of EN 60079-0:2009 and EN 60079-15:2010. Installation, operation, and maintenance may only be carried out by qualified electricians. Follow the installation instructions described. When installing and operating the device, the applicable regulations and safety directives (including national safety directives), as well as general technical regulations, must be observed. The technical data is provided in this package slip and on the certificates (conformity assessment, additional approvals where applicable). It is not permissible to open or modify the device. Do not repair the device yourself but replace it with an equivalent device. Repairs may only be carried out by the manufacturer. The manufacturer is not liable for damage resulting from violation. The IP20 degree of protection (IEC 60529/EN 60529) of the device is intended for use in a clean and dry environment. Do not subject the device to any load that exceeds the described limits. The device is not designed for use in atmospheres with a danger of dust explosions. 105449_en_00 5.2 – – – – – – Installation in the Ex area (zone 2) Observe the specified conditions for use in potentially explosive areas. The device must be installed in a housing (control or distributor box) which meets the requirements of EN 6007915 and provides at least IP54 (EN 60529) degree of protection. During installation and when connecting the supply and signal circuits, observe the requirements of EN 6007914. Devices may only be connected to circuits in zone 2 if they are suitable for operation in Ex zone 2 and for the prevailing conditions at the place of use. In potentially explosive areas, terminals may only be snapped onto or off the DIN rail connector and wires may only be connected or disconnected when the power is switched off. The device must be stopped and immediately removed from the Ex area if it is damaged, has been subjected to an impermissible load, has been stored incorrectly, or if it malfunctions. You can download the latest documents for these devices from www.phoenixcontact.net/products. PHOENIX CONTACT 5 MINI MCR-SL-PTB-FM 6.3 6 Installation 6.1 Connection notes Block diagram IN 1 OUT FM NOTE: Electrostatic discharge! The device contains components that can be damaged or destroyed by electrostatic discharge. When handling the device, observe the necessary safety precautions against electrostatic discharge (ESD) according to EN 613405-1 and EN 61340-5-2. 2 3 4 IN + 1 5 + PWR 1 IN 6 – PWR 1 IN / OUT-FM +24V – 2 + 3 7 + PWR 2 IN 8 – PWR 2 IN / OUT-FM +24V – 4 – + +24V PWR OUT Zone 2 +24V 6.2 +24V Structure Figure 2 3 4 6.4 y an erm , G -FM erg TB 8 P mb lo L- 95 5 B R–S 02 82 k 32 I MC .: 29 loc o l B MINrd.–N ina m r O rity e r T ax. 2A2A e pola e rs w m . Po VDC max Reve K .30 ,2VDC R2 R2 O .. 0 W IN: 0...29 1 / P / PW 49°F R K T: .+1 OU : PWR1 O –4°.. rd W / 2/1 gn: P 65°C V +24 LED 4/3 0°...+ + 1 1 PWR 1T-FM 2 2 LED – OU 7 Tamb +24 www.phoenixcontact.com 8 4 3 2 4 PW RO + 2 R M PWOUT-F IN/ - +24 FM 2 Recommended fuse for power terminal block: Fuse in acc. with IEC 60127-2/V Nominal current: 2.5 A Characteristics: Slow-blow (e.g. Wickmann 5 x 20 mm/No. 195 - glass fuse) V G Gc X II 3 A II C T4 Ex n UT + V +24 10 o. ial N Ser T OU NOTE: Never connect the supply voltage directly to the DIN rail connector. It is not permitted to draw power from the DIN rail connector or from individual modules. IN/ - 3 5 + R1 PW V IN - 6 7 + R2 PW V IN 8 +24 - 9 6.5 – Figure 1 1. 2. 3. 4. Structure Input: supply voltage 1 or fault monitoring output Input: supply voltage 2 or fault monitoring output Cover Diagnostic LEDs 1 + 2: supply voltage connected with reverse polarity 5. Diagnostic LEDs 3 + 4: supply voltage present 6. Groove for ZBF 6 zack marker strip 7. Input: supply voltage 1 8. Input: supply voltage 2 9. Connection for DIN rail connector 10. Universal snap-on foot for EN DIN rails 105449_en_00 Power supply 1 Warning – Do n ot seperate when energized 5 6 Block diagram – – Use in the MINI Analog system Up to 80 MINI Analog modules are supplied at a supply voltage of 18...30 V DC. In the event of a supply voltage below 18 V DC, the number of modules is reduced according to the increasing current flow. Up to 40 MINI Analog modules are supplied at a supply voltage of 12 V DC (50 mA per device). NOTE The total current in both supply paths must not exceed 2 A. Connect at least one supply to the power terminal in order to supply the DIN rail connector. • Wire the second input to provide redundancy. PHOENIX CONTACT 6 MINI MCR-SL-PTB-FM For additional mechanical redundancy, two power terminals and two fault monitoring modules can be used. Only one supply may be connected to each power terminal. In the second fault monitoring module, fault monitoring of external measuring transducers must be deactivated because evaluation can only take place via a module in a group. 6.6 6.7 Connecting the wires The module is available in two connection versions: – Screw terminal blocks (for MINI MCR-SL-PTB-FM) – Spring-cage terminal blocks (for MINI MCR-SL-PTB-FMSP) Screw connection: B Assembly B A www.interface.phoenixcontact.com A C D E Figure 4 • • X XXX XXX o. X al N Seri Screw connection Insert the wire into the corresponding connection terminal block. Use a screwdriver to tighten the screw in the opening above the connection terminal block. Spring-cage connection: A Figure 3 – B Mount the module on a 35 mm DIN rail according to EN 60715. When using the DIN rail connector, first place it into the DIN rail (see A – C). It is used to bridge the power supply. It is also absolutely vital that you snap the module and the DIN rail connector into position in the correct direction: the snap-on foot should be at the bottom and the connector on the left. www.interface.phoenixcontact.com – Mounting and removing Figure 5 • • 105449_en_00 X XXX XXX o. X al N Seri Spring-cage connection Insert a screwdriver into the opening above the connection terminal block. Insert the wire into the corresponding connection terminal block. PHOENIX CONTACT 7 MINI MCR-SL-PTB-FM 7 Fault monitoring FM 8 Fault monitoring simplifies error evaluation in multi-channel – isolation amplifier applications using a group error message. – 7.1 Fault monitoring for group error detection • • Use MINI Analog signal conditioners that support fault monitoring. Connect these signal conditioners to the MINI MCR-SLFM-RC(-SP)-NC fault monitoring module via the DIN rail connector . Diagnostic indicator The green LEDs on the front indicate that the relevant supply voltages are present on the DIN rail connector. Red LEDs light up when supply voltages are connected to the wrong poles. In the case of a correctly connected supply voltage, the red LED goes out. Detected errors on the signal input of a MINI Analog isolation amplifier or in the isolation amplifier are reported to the fault monitoring module via the DIN rail connector. The module reports the error centrally via an N/C contact. 7.2 Fault monitoring for redundancy monitoring With "supply via power terminal", the fault monitoring module can be used to monitor the supply voltage in the group. Failure of the supply voltage generates a central message via an N/C contact. • Install a power terminal and a fault monitoring module of the same shape side-by-side without spacing. • Bridge terminals 1 to 4 of the power terminal with terminals 1 to 4 of the fault monitoring module. Use the provided plug-in bridges FB S2-6 (Order No. 3030336) or normal cables. 105449_en_00 PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany www.phoenixcontact.com 8
2902958 价格&库存

很抱歉,暂时无法提供与“2902958”相匹配的价格&库存,您可以联系我们找货

免费人工找货