DFA20E48D12

DFA20E48D12

  • 厂商:

    POWER-ONE

  • 封装:

    DIP7模块

  • 描述:

    隔离模块 直流转换器 2 输出 12V -12V 850mA,850mA 36V - 72V 输入

  • 数据手册
  • 价格&库存
DFA20E48D12 数据手册
DFA20 Dual-Output DC-DC Series Data Sheet Description The compact, dual output DFA20 Series provides power densities up to 11 watts per cubic inch (0.67 watts per cm3). Ideal for battery-operated industrial, medical control, and remote data collection systems, this converter has fully-filtered inputs and outputs. Complete overload protection with independent pulseby-pulse current limiting and an overtemperature shutdown ensures reliable system operation. Converters with 48 volt inputs are isolated to 1544 volts. Features • RoHS lead solder exemption compliant • Remote on/off and trim • Water-washable case • Overcurrent protection and thermal shutdown • Efficiencies to 85% • Low input-to-output capacitance • 700V to 1544V isolation • Five-sided shielded case General Specifications (1) Model Selection Model DFA20E12D5 DFA20E12D12 Input Range (VDC) Min Max 9 18 9 Output (VDC) ±5 Output (mA) 1700 18 ±12 850 DFA20E12D15 9 18 ±15 700 DFA20E24D5 18 36 ±5 1700 DFA20E24D12 18 36 ±12 850 DFA20E24D15 18 36 ±15 700 DFA20E48D5 36 72 ±5 1700 DFA20E48D12 36 72 ±12 850 DFA20E48D15 36 72 ±15 700 All Models ON/OFF Function ON Logic Level or Leave Pin Open OFF Logic Level or Tie Pin to -Input Open Circuit Voltage BOTTOM VIEW 2.02 (51.31) SIDE VIEW 0.040 (1.02) DIA 7 PLACES 4 1.100 (27.94) 0.700 (17.78) 0.600 (15.24) 0.400 (10.16) 0.300 (7.62) 0.000 0.100 (2.54) 5 1 2 3 6 MIN >1.6 VDC MAX 40 Noise, 0-20MHz bw (2) RMS Noise, 0.01-1 MHz bw TYP TYP TYP MAX Output Voltage Accuracy Output Balance Plus to Minus Output, Full Load Rated Load Range Load Regulation (3) Temperature Coefficient 0.0 1.7 0.3 0.7 3 < 0.1 0.8 50 15 50 10 50 150 Short Circuit Protection to Common for all Outputs DFA20E12D15 DFA20E24D15 DFA20E48D15 ±15 14.90 15.00 15.10 Units VDC VDC % 0.0 0.7 0.2 0.6 3 < 0 .2 0.8 A % % % %/24Hrs %/kHrs dB 50 10 mV PP mVrms ppm/°C Continuous, Current Limit and Thermal Protection Specification notes for this page are located on the next page. MCD10174 Rev. 1.0, 15-Jun-10 Page 2 of 4 www.power-one.com DFA20 Dual-Output DC-DC Series Data Sheet NOTES (1) All parameters measured at Tc=25°C, nominal input voltage and full rated load unless otherwise noted. (2) Noise measurement bandwidth is 0-20 MHz for peak-peak measurements, 10 kHz to 1 MHz for RMS measurements. Output noise is measured with a 1μF tantalum located 1" away from the converter to simulate PCB standard decoupling. Input reflected ripple is measured into a 1 μH source impedance. (3) Load regulation for the outputs is specified as the voltage change when both outputs are changed from maximum to minimum at the same time. (4) Cross regulation is defined as the change in one output when the other output is changed from full load to 25% of full load. The converter can be run at no load on either or both outputs with no damage. (5) Short term stability is specified after a 30-minute warmup at full load, constant line and recording the drift over a 24-hour period. (6) The input ripple rejection is specified for DC to 120 Hz ripple with a modulation amplitude of 1% of Vin. DFA20 SERIES APPLICATION NOTES: Additional output capacitance may be added for increased filtering, but should not exceed 400μF. Remote ON/OFF Operation The remote ON/OFF pin may be left floating if this function is not used. It is recommended to drive this pin with an open collector arrangement or a relay contact. When the ON/OFF pin is pulled low with respect to the INPUT, the converter is placed in a low power drain state. Output TRIM The TRIM pin may be used to adjust the output ±5% from the nominal setting. This function allows adjustment for voltage drops in the system wiring. Figure 1 shows the proper connections to use this function. If the TRIM function is not required, the pin may be left floating. External Capacitance Requirements No external capacitance is required for operation of the DFA20 Series. The use of input capacitors with less than 0.5V ESR may cause peaking in the input filter and degrade filter performance. External output capacitance is not required for operation, however it is recommended that 1μF to 10μF of tantalum and 0.001 to 0.1μF ceramic capacitance be selected for reduced system noise. +OUT 4 +OUT 4 TRIM DOWN TRIM 7 10K TRIM 7 LOAD -OUT 6 LOAD TRIM UP -OUT 6 USING TRIMPOT USING FIXED RESISTORS Figure 1. OUTPUT POWER DERATING DFA20 SERIES BLOCK DIAGRAM 20 SHIELDED ISOLATION TRANSFORMER + + + INPUT 1 – INPUT 2 LOW NOISE FILTER CURRENT MODE PWM + ON/OFF 4 + OUTPUT 5 CMN 6 – OUTPUT 7 TRIM 0 50 SHIELDED COPPER CASE MCD10174 Rev. 1.0, 15-Jun-10 10 5 – 3 15 POWER OUTPUT THERMAL LIMIT Page 3 of 4 60 70 80 90 AMBIENT TEMPERATURE 100 www.power-one.com DFA20 Dual-Output DC-DC Series Data Sheet Typical Performance: (Tc=25 C, Vin=Nom VDC, Rated Load) 12 VOLT EFFICIENCY Vs. LINE INPUT VOLTAGE 12 VOLT EFFICIENCY Vs. LOAD 85 3.5 LINE = 12VDC LINE = 18VDC 75 80 100% FULL LOAD 75 70 70 0 10 20 30 40 50 60 70 80 9 90 100 10 11 12 13 14 15 16 17 24 VOLT EFFICIENCY Vs. LOAD 80 LINE = 24VDC 75 LINE = 36VDC 10 20 30 40 50 60 70 80 100% FULL LOAD 85 50% FULL LOAD 80 75 18 90 100 22 24 26 28 30 32 34 LINE = 48VDC LINE = 72VDC 20 30 40 50 60 70 LOAD (%) 80 90 100 12 14 16 18 100% LOAD 50% LOAD 0.5 4 8 16 12 20 24 28 32 36 LINE INPUT (VOLTS) 48 VOLT INPUT CURRENT Vs. LINE INPUT VOLTAGE 1.00 85 80 50% FULL LOAD 75 70 36 10 1.0 0 INPUT CURRENT (AMPS) EFFICIENCY (%) EFFICIENCY (%) LINE = 36VDC 8 6 1.5 36 100% FULL LOAD 10 4 0.0 20 90 0 2 24 VOLT INPUT CURRENT Vs. LINE INPUT VOLTAGE 48 VOLT EFFICIENCY Vs. LINE INPUT VOLTAGE 48 VOLT EFFICIENCY Vs. LOAD 60 0.5 LINE INPUT (VOLTS) 90 75 50% LOAD 1.0 2.0 LOAD (%) 80 1.5 LINE INPUT (VOLTS) INPUT CURRENT (AMPS) EFFICIENCY (%) LINE = 18VDC 0 100% LOAD 2.0 0 90 70 2.5 0.0 18 24 VOLT EFFICIENCY Vs. LINE INPUT VOLTAGE 90 85 3.0 LINE INPUT (VOLTS) LOAD (%) EFFICIENCY (%) INPUT CURRENT (AMPS) EFFICIENCY (%) EFFICIENCY (%) 50% FULL LOAD 80 12 VOLT INPUT CURRENT Vs. LINE INPUT VOLTAGE 85 LINE = 9VDC 40 44 48 52 56 60 64 LINE INPUT (VOLTS) 68 72 0.75 100% LOAD 0.50 50% LOAD 0.25 0.00 0 10 20 30 40 50 60 70 80 LINE INPUT (VOLTS) NOTES ON USING THE CURVES 1) The input currents are for 20 watts of output power. For ±5 volt output models the current is approximately 15% less. 2) The efficiency curves are for 12 volt output models. To use for other models adjust as follows: ±5 volt models subtract approximately 3%. ±15volt models add approximately 1%. NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. MCD10174 Rev. 1.0, 15-Jun-10 Page 4 of 4 www.power-one.com
DFA20E48D12 价格&库存

很抱歉,暂时无法提供与“DFA20E48D12”相匹配的价格&库存,您可以联系我们找货

免费人工找货