HZZ00147-G

HZZ00147-G

  • 厂商:

    POWER-ONE

  • 封装:

  • 描述:

    HEAT SINK FOR RCM150 SERIES

  • 数据手册
  • 价格&库存
HZZ00147-G 数据手册
RCM Series Data Sheet 150 /300 W DC-DC Converters Features Description The RCM Series converters are reliable power supplies for railway and transportation systems. There are 2 input voltage ranges covering all common railway batteries. The output delivers 150 or 300 W at 12 or 24 V. The converters are designed for chassis mounting and exhibit a closed housing. Many options are available, such as an output ORing FET for redundant operation, output voltage adjustment, interruption time of 10 ms (class ST2), shutdown input, and an output voltage monitor controlling a relay (change-over contact). • RoHS lead-free-solder product • 2 input voltage ranges, covering all railway batteries • 2 output voltages, 12 and 24 V • Closed housing for chassis mounting • Extremely high efficiency and high power density • Low inrush current • 3 connectors: Input, output, auxiliary • Overtemperature, overvoltage, overcurrent, and overload protection • Many options available • Compliant to EN 50155, EN 50121-3-2 • Fire and smoke: compliant to to EN 45545 and NFPA 130 Safety-approved to the latest edition of IEC/EN 60950-1 and UL/CSA 60950-1 in process 1 1 Table of Contents pending Page Description ............................................................................ 1 Model Selection .................................................................... 2 Functional Description .......................................................... 3 Electrical Input Data .............................................................. 4 Electrical Output Data ........................................................... 6 Description of Options ......................................................... 8 Page Electromagnetic Compatibility (EMC) .................................. 9 Immunity to Environmental Conditions .............................. 11 Mechanical Data ................................................................. 12 Safety and Installation Instructions .................................... 13 Accessories ........................................................................ 14 Copyright © 2017, Bel Power Solutions Inc. All rights reserved. BCD.00791 Rev AD, 4-May-2017 MELCHER The Power Partners. Page 1 of 15 RCM Series Data Sheet 150 /300 W DC-DC Converters Model Selection Table 1: Model Selection V i min 1 [V] 1 2 Input voltage Vi cont [V] 14.4 16.8 (24) 43.2 50.4 14.4 43.2 45 V i max1 [V] Output Vo nom Io nom [V] [A] Power Po nom [W] Efficiency η min2 η typ [%] [%] 50.4 12 24 12.5 6.25 150 150 88 89 (110) 137.5 154 12 24 12.5 6.25 150 150 91 92 16.8 (24) 50.4 12 24 25 12.5 300 300 89 90 50.4 (110) 137.5 154 12 24 25 12.5 300 300 91 92 45 92.5 93 93.5 Model Options 24RCM150-12 24RCM150-24 D, M, Q, F 110RCM150-12 110RCM150-24 D, M, Q, F 24RCM300-12 24RCM30024 D, M, Q, F 110RCM300-12 110RCM300-24 D, M, Q, F Short time; see table 2 for details Efficiency at TA = 25 °C, Vi nom, Io nom, Vo nom, only option D fitted Part Number Description 110 RCM 150 -24 D M Q Operating input voltage Vi cont (continuously): 16.8 – 45 VDC .......................................................... 24 50.4 – 137.5 VDC .................................................... 110 Series ........................................................................... RCM Output power: 150 W .................................................................... 150 300 W .................................................................... 300 Nominal output voltage: 12 V .......................................................................... -12 24 V .......................................................................... -24 Auxiliary functions and options: Out OK, output voltage adjust, shutdown 1 .................. D Interruption time .......................................................... M ORing FET ................................................................... Q Fuse ............................................................................. F 1 Opt. D requires the signal connector. Note: The sequence of options must follow the order above. Available combinations of options: Note: All models are RoHS-compliant for all six substances. Example: 110RCM150-24DMQ: DC-DC converter, input voltage range 50.4 to 137.5 V continuously, output providing 24 V / 6.25 A, monitoring relay, output voltage adjust, shutdown input, interruption time 10 ms, integrated ORing FET, operating ambient temperature TA = – 40 to 70 °C, RoHS-compliant for all six substances. Product Marking Type designation, applicable safety approval and recognition marks, CE mark, pin allocation, and product logo. BCD.00791 Rev AD, 4-May-2017 24/110RCMxxx-xx 24/110RCMxxx-xxD 24/110RCMxxx-xxDF 24/110RCMxxx-xxDMQ 24/110RCMxxx-xxDMQF No option Basic communication model Industrial version Railway version All options Input voltage range and input current, nominal output voltage and current, degree of protection, batch no., serial no., and data code including production site, version (modification status) and date of production. MELCHER The Power Partners. Page 2 of 15 RCM Series Data Sheet 150 /300 W DC-DC Converters An auxiliary converter supplies all circuits with a stable bias voltage. Functional Description The converters are designed as active clamp forward converters with a switching frequency of approximately 120 kHz. The built-in high-efficient input filter together with a small input capacitance generates very low inrush current of short duration. An antiparallel suppressor diode acts as reverse polarity protection together with the external circuit breaker or fuse. An output ORing FET is available (option Q) and allows for a redundant power supply system. If there are no external circuit breakers, it is possible to order the converter with incorporated fuse (opt. F). Because this fuse is not accessible, a serial diode provides the reverse polarity protection (only with option F or M). Opt. D encompasses an additional signal connector and allows for output voltage adjust and a primary shutdown. An output voltage monitor controls a relay with a change-over contact. The circuitry providing the interruption time (opt. M) is located after the input filter. The rectification on the secondary side is provided by synchronous rectifiers, in order to keep the losses as low as possible. The output voltage control logic is located on the secondary side and influences the primary logic through magnetic feedback. The converter is mounted onto a base plate, which acts as heat sink. An additional heatsink for air cooling is available as accessory. NTC R– Primary control logic SD Isolated driver SD0 R R R+ JM194c OK1 OK2 Secondary control logic OK0 Fuse (option F) 1 Isolation Vi+ Opt. M NTC Opt. Q Input filter + Chu Vi– PE Vo+ Output filter Vo– Cy Auxiliary converter Cy Cy Auxiliary connector (only with option D) 1 Reverse protection diode, only fitted with opt. F or M Fig. 1 Block diagram BCD.00791 Rev AD, 4-May-2017 MELCHER The Power Partners. Page 3 of 15 RCM Series Data Sheet 150 /300 W DC-DC Converters Electrical Input Data General Conditions: – TA = 25 °C, unless TC is specified. – R input not connected Table 2a: Input data of RCM150 Input 24RCM150 110RCM150 Unit Characteristics Conditions min typ max min typ max Vi Operating input voltage Io = 0 – Io max TC min – TC max 16.8 (24) 45.0 50.4 (110) 137.5 V i 2s for ≤ 2 s without shutdown 14.4 50.4 43.2 V i nom Nominal input voltage V i abs Input voltage limits 3 s without damage 24, 36 0 V 154 72, 96, 110 55 0 165 Ii Typical input current Vi nom, Io nom 1.5 Pi 0 No-load input power Vi min – Vi max, Io = 0 42 6 A P i SD Idle input power Vi min – Vi max, V SD = 0 V 0.7 2 1.5 Ci Input capacitance 1 Ri Input resistance I inr p Peak inrush current t inr d Duration of inrush current t on Start-up time at switch on 0 → Vi min, Io nom Start-up time after removal of shutdown Vi min ≥ 16.8 V, Io nom V SD = 0 → 5 V 10 W µF Vi = 137.5 V, Io nom 100 mΩ 20 A 10 ms 1000 1000 300 300 Table 2b: Input data of RCM300 Input 24RCM300 110RCM300 Unit Characteristics Conditions min typ max min typ max Vi Operating input voltage Io = 0 – Io max TC min – TC max 16.8 (24) 45.0 50.4 (110) 137.5 without shutdown 14.4 50.4 43.2 V i 2s for ≤ 2 s V i nom Nominal input voltage V i abs Input voltage limits 3 s without damage Ii Typical input current Vi nom, Io nom 3 5 24 (36) Pi 0 No-load input power Vi min – Vi max, Io = 0 P i SD Idle input power Vi min – Vi max, V SD = 0 V Ci Input capacitance 1 Ri Input resistance I inr p Peak inrush current t inr d Duration of inrush current t on Start-up time at switch on 0 → Vi min, Io nom Start-up time after removal of shutdown Vi min ≥ 16.8 V, Io nom V SD = 0 → 5 V 1 2 0 V 154 (72) (96) 110 55 0 165 A W 1 12 µF mΩ Vi = 137.5 V, Io nom A 0 1000 1000 300 300 ms Not smoothed by the inrush current limiter at start-up (for inrush current calculation) Typ. value at Vi max. At lower Vi, the idle and low-load input power is smaller. BCD.00791 Rev AD, 4-May-2017 MELCHER The Power Partners. Page 4 of 15 RCM Series Data Sheet 150 /300 W DC-DC Converters Input Transient and Reverse Polarity Protection A suppressor diode and a symmetrical input filter form an effective protection against input transients, which typically occur in most installations, but especially in battery-driven mobile applications. If the input voltage has the wrong polarity, an antiparallel diode will cause the external input circuit breaker or fuse to trip. If the fuse is incorporated (opt. F), a serial diode prevents reverse current. Input Under- / Overvoltage Lockout Vi+ Ri Converter Vo+ Load ri Ci The efficiency depends on the model and on the input voltage. 110RCM150-12DMQ JM217 100 Vi = 110 V Vi = 50 V Vi = 137 V 80 + Cext Efficiency 90 JM085d Rext Recommended values for Cext for different batteries are listed in table 3, which should allow for stable operation up to an input inductance of 2 mH. Ci is specified in table 2. η [%] If the input voltage is out of range, an internally generated inhibit signal disables the converter to avoid any damage. Lext reach stable operating conditions. Worst case conditions are at lowest Vi and highest output power Po. 70 Vo– Vi– 60 Fig. 2 Input configuration 0 0.2 0.4 0.6 0.8 Po / Po nom Fig. 3a Efficiency versus Vi and Po (110RCM150-12) Inrush Current and Stability with Long Supply Lines The converter operates with relatively small input capacitance C i resulting in low inrush current of short duration. If a converter is connected to the power source through supply lines with reasonable length, no additional measures are necessary to ensure stable operation. Only in the case of very long supply lines exhibiting a considerable inductance Lext, an additional external capacitor Cext connected across the input pins improves the stability and prevents oscillations. Actually, an RCM Series converter with its load acts as negative resistor r i, because the input current I i rises, when the input voltage Vi is decreased. It tends to oscillate with a resonant frequency determined by the line inductance L ex t and the input capacitance Ci + Cext, damped by the resistor R ext. The whole system is not linear at all and eludes a simple calculation. One basic condition is given by the formula: L • Po max Ci + Cext > —ext ——— — — — — — — Rext • Vi min² ( dV i —— ) ri = — dI i η [%] JM210a 100 Vi = 110 V Vi = 50 V 90 Vi = 137 V 80 70 60 0 0.2 0.4 0.6 0.8 Po / Po nom Fig. 3b Efficiency versus Vi and Po (110RCM150-24) η [%] 110RCM300-24DMQ JM218 100 Rext is the series resistor of the voltage source including supply lines. If this condition is not fulfilled, the converter may not 110RCM150-24DMQ Vi = 110 V Vi = 50 V 90 Vi = 137 V 80 Table 3: Recommended values for the capacitor Cext V B nom RC150 RCM300 Rated voltage 24 V 1500 µF 3000 µF 40 V 36 V 1000 µF 2000 µF 63 V 72 V 220 µF 440 µF 125 V 110 V 100 µF 200 µF 200 V BCD.00791 Rev AD, 4-May-2017 70 60 0 0.2 0.4 0.6 0.8 Po / Po nom Fig. 3c Efficiency versus Vi and Po (110RCM300-24) MELCHER The Power Partners. Page 5 of 15 RCM Series Data Sheet 150 /300 W DC-DC Converters Electrical Output Data General Conditions: – TA = 25°C, unless TC is specified. – R input not connected Table 4a: Output data of RCM150 Output 12 V Characteristics Conditions 24 V Unit min typ max min typ max Vo Output voltage 1 Vi nom, 0.5 Io nom 11.88 12 12.12 23.76 24 24.24 Vow Worst case output voltage Vi min – Vi max TC min – TC max, 0 – Io nom 11.64 12.36 23.28 15.8 28.5 Vo droop Voltage droop –20 Vo P Overvoltage protection 2 Vo L Overvoltage shutdown 6 Io nom Nominal output current Io L Output current limit TC min – TC max vo Output noise 3 Switch. frequ. Total incl. spikes Vi nom, Io nom BW = 20 MHz Dynamic load regulation Voltage deviation 5 Vi nom 0.1 ↔ 0.9 Io nom vo d t d4 αVo Recovery time Temp. coefficient of Vo (NTC) 14.3 15 6.5 V A 7.2 40 80 60 120 700 1000 –0.02 mV/A 31.5 6.25 14.4 5 0 – Io nom, TC min – TC max 30 28 12.5 13.0 24.72 –40 14 V mVpp 5 0 – 0.02 0 ms % /K Table 4b: Output data of RCM300 Output 12 V Characteristics Conditions min typ 12 Vo Output voltage 1 Vi nom, 0.5 Io nom 11.88 Vow Worst case output voltage Vi min – Vi max TC min – TC max, 0 – Io nom 11.64 24 V max min typ 12.12 23.76 24 12.36 23.28 Unit max 24.24 Vo droop Voltage droop mV/A protection 2 Vo P Overvoltage Vo L Overvoltage shutdown 6 Io nom Nominal output current Io L Output current limit TC min – TC max vo Output noise 3 Switch. frequ. Total incl. spikes Vi nom, Io nom BW = 20 MHz vo d Dynamic load regulation Voltage deviation 5 Vi nom 0.1 ↔ 0.9 Io nom t d4 αVo 1 2 3 4 5 6 Recovery time Temp. coefficient of Vo (NTC) V 24.72 14.3 15 15.8 28.5 14 31.5 V 28 25 12.5 13.5 A 15 80 mVpp 120 5 0 – Io nom, TC min – TC max 30 – 0.02 5 0 –0.02 0 ms % /K If the output voltage is increased above Vo nom through R-input control, the output power should be reduced accordingly, so that Po max and TC max are not exceeded. Breakdown voltage of the incorporated suppressor diode at 1 mA . Exceeding this value might damage the suppressor diode. Measured according to IEC/EN 61204 with a probe described in annex A Recovery time until Vo returns to ±1% of Vo; see fig. 4. No overshoot at switch on. Output overvoltage protection by an electronic circuitry. BCD.00791 Rev AD, 4-May-2017 MELCHER The Power Partners. Page 6 of 15 RCM Series Data Sheet 150 /300 W DC-DC Converters Output Voltage Regulation Parallel and Series Connection Line and load regulation of the output is so good that input voltage and output current have virtually no influence to the output voltage. The outputs of max. 5 RCM Series converters may be connected in series without restrictions. Vo Vod Vo ±1 % Parallel operation is only recommended for redundant systems (option Q). To ensures proper current sharing, the load lines should have equal length and section. The output voltage exhibits a slight droop characteristic, which facilitates current sharing. In addition, the output voltage tends to be lowered with increasing temperature. Vo ±1 % Vod td td t Io /Io nom Redundant Systems 1 0.5 Note: If the sum of the output voltages is greater than 60 V, it cannot be considered being SELV (Safety Extra Low Voltage) according to the safety standards. ≥ 10 µs For redundant systems, we recommend the options Q and D, see Options. ≥ 10 µs 0 05102c t LE D Indicator The converters exhibit a green LED "Out OK", signaling that the output voltage is within the specified range. Fig. 4 Typical dynamic load regulation of output voltage Thermal Considerations A temperature protection is incorporated in the primary and secondary control logic each. Output Current Limitation The output is continuously protected against open-circuit (no load) and short-circuit by an electronic current limitation with rectangular characteristic; see fig. 5. Vo Vo nom 0.98 0.5 JM219 0 0.5 1.0 IoL Io Io nom Fig. 5 Rectangular current limitation of single-output models BCD.00791 Rev AD, 4-May-2017 MELCHER The Power Partners. Page 7 of 15 RCM Series Data Sheet 150 /300 W DC-DC Converters Description of Options SD and SD0 (= Vi–). If the shutdown function is not required, pin SD can be left open-circuit. Voltage on pin SD: Option D: Output Monitor, Output Adjust, Shutdown Option D consists of several auxiliary functions and encompasses an additional auxiliary connector. Converter operating: Converter disabled: The output response is shown in fig. 7. Note: In systems consisting of several converters, this feature may be used to control the activation sequence by logic signals or to enable the power source to start up, before full load is applied. Output Voltage Adjust (R) Note: With open R-input, Vo = Vo nom. The converter allows for adjusting the output voltage in the range of 80 to 105% of Vo nom. The adjust is accomplished by an external resistor R ext1 or R ext2 , connected to the R-input; see fig. 6. Depending on the value of the required output voltage, the resistor shall be connected: either: Between the R-pin and R– to adjust the output voltage to a value below Vo nom : Option M: Interruption Time The interruption time t hu is specified in the railway standard Vo /Vo nom 1 0.1 0 Vo Rext1 ≈ 4 kΩ • ––––––––– – 15.8 kΩ Vo nom – Vo Note: Rext1 = 0 Ω reduces Vo to 80%. (Vo – 2.5 V) –––––––– – 682kΩ Rext2 ≈ 4 kΩ • –––––––––– 2.5 V • (Vo /Vo nom – 1) JM191 Bias 4 kΩ R + Control logic Rext1 15.8 kΩ td on ton t off 0 JM193a t For less critical applications, option M is not required (class S1, no interruption time). R– Vi– Option Q: ORing FET for Redundant Systems Vo– The outputs of 2 parallel connected converters are separated with ORing diodes (built by FETs). If one converter fails, the remaining one must be capable to still deliver the full power to the load. If more power is needed, the system may be extended to more parallel converters (n+1 redundancy). Fig. 6 Output voltage control via R-input Output Voltage Monitor (D) The output voltage Vo is monitored. When Vo is in range, a relay with a change-over contact is activated. Note: The trigger levels are typ. ±5 % of Vonom (with open R-input). Data of relay contacts: 0.4 A /150 VDC Primary Shutdown (SD) The output of the converter may be enabled or disabled by a logic signal (e.g. CMOS) applied between the shutdown pin BCD.00791 Rev AD, 4-May-2017 tf EN 50155 clause 5.1.1.3: Class S2 is 10 ms. It is measured at VB nom (nominal battery voltage) for interruption and shortcircuit of the input. After such an event, the system is ready for the next event after 10 s. Fig. 7 shows the output voltage Vo, if option M is fitted. R+ Rext2 Vref = 2.5 V thu Fig. 7 Typical output response to the SD-signal. If option M is not fitted, thu = 0 ms. Note: Rext2 = 0 Ω increases Vo to 105%. 628 kΩ tr SD 1 or: Between the R-pin and R+ to adjust the output voltage to a value greater than Vo nom : Vi+ 12 to 154 V or open-circuit – 2 to +2 V Current sharing must be ensured by load lines of equal section and length. In addition, a slight droop characteristic of the output voltage and a negative temperature coefficient are helpful as well. To keep the losses as small as possible, the ORing diode is replaced by a FET. The voltage drop is approx. 22 mV (not dependent of Io). Note: In the case of a failing converter, the output voltage is maintained by the redundant converters. However, the failing item should be identified and replaced. We recommend the Out OK function (option D). MELCHER The Power Partners. Page 8 of 15 RCM Series Data Sheet 150 /300 W DC-DC Converters Option F: Incorporated Fuse Table 5: Recommended for external fuses The railway standard EN 50155 bans fuses in the converters. Consequently, the installer must preview an external fuse or circuit breaker. However, when this is not possible, we offer an incorporated fuse. This fuse is not accessible and will not trip, except if the converter is defect. Note: Converters with option F or option Q are protected against input reverse polarity by a series diode. Converter Fuse specification Ordering number 24RCM150-12, -24 15 A fast acting BEL 3AB (P) 15-R 24RCM300-12, -24 25 A fast acting Littlefuse 0314025 110RCM150-12, -24 5 A fast acting BEL 3AB (P) 5-R 110RCM300-12, -24 8 A fast acting BEL 3AB (P) 8-R Electromagnetic Compatibility (EMC) Electromagnetic Immunity Table 6: Electromagnetic immunity (type tests) Phenomenon Standard Level Coupling mode 1 Value applied Waveform Source imped. Test procedure Electrostatic discharge (to case) IEC/ EN 61000-4-2 43 contact discharge 6000 Vp 1/50 ns air discharge 8000 Vp 330 Ω 150 pF 10 positive and 10 negative discharges Electromagnetic field IEC/ EN 61000-4-3 x4 antenna 20 V/m AM 80% / 1 kHz n.a. 80 – 800 MHz yes A 5 antenna 20 V/m AM 80% / 1 kHz n.a. 800 – 1000 MHz yes A Electrical fast transients/burst IEC/ EN 61000-4-4 Surges Conducted disturbances 1 2 3 4 5 6 7 8 10 V/m 1400 – 2000 MHz 5 V/m 2000 – 2700 MHz 3 V/m 5100 – 6000 MHz In Perf. oper. crit.2 yes A ±2000 Vp bursts of 5/50 ns 2.5/5 kHz over 15 ms; burst period: 300 ms 50 Ω 60 s positive 60 s negative transients per coupling mode yes A i/c ±2000 Vp 1.2/50 µs A ±1000 Vp 5 pos. and 5 neg. surges per coupling mode yes +i/–i 42 Ω 0.5 µF i, o, signal wires 10 VAC (140 dBµV) AM 80% 1 kHz 150 Ω 0.15 – 80 MHz yes A 3 capacitive, o/c 36 i/c, +i/–i direct IEC/ EN 61000 -4-5 37 IEC/ EN 61000-4-6 38 i = input, o = output, c = case A = normal operation, no deviation from specs.; B = normal operation, temporary loss of function or deviation from specs possible Exceeds EN 50121-3-2:2015 table 6.3 Corresponds to EN 50121-3-2:2015 table 6.1 Corresponds to EN 50121-3-2:2015 table 6.2 (compliance with digital communication devices). Corresponds to EN 50121-3-2:2015 table 4.2 Covers or exceeds EN 50121-3-2:2015 table 4.3 Corresponds to EN 50121-3-2:2015 table 5.1 (radio frequency common mode). BCD.00791 Rev AD, 4-May-2017 MELCHER The Power Partners. Page 9 of 15 RCM Series Data Sheet 150 /300 W DC-DC Converters Electromagnetic Emissions The conducted emissions (fig. 9) have been tested according to EN 55011 (similar to EN 55032, much better values than requested by EN 50121-3-2:2015, table 1.1). The limits in fig. 8 apply to quasipeak values, which are always lower then peak values. Radiated emissions have been tested according to EN 55011 group 1, class A (similar to EN 55032), see EN 50121-32:2015, table 3.1. The test is executed with horizontal and vertical polarization. The worse result is shown in fig. 9. dBµV/m VUS EMC Labatory, 110RCM150-24DMQF; Vi = 110 VDC, Vo = 24 V / 6.25 A Testdistance 10 m, Class A, 3-Oct-2016; ESVS 30, Rhode & Schwarz 60 JM212 50 40 30 20 10 0 30 110RCM150-24DMQF; Vi = 110 V, Vo = 24 V; Io = 6.25 A Class A, 3-Oct-2016 dBµV EN 55011 A qp JM211 80 EN 55011 A av 60 50 100 200 500 1000 MHz Fig. 9a 110RCM150-24: Typ. radiated disturbances in 10 m distance (Vi = 110 V, I i nom, resistive load, quasi peak). 40 dBµV/m 20 VUS EMC Labatory, 300RCM150-24DMQF; Vi = 110 VDC, Vo = 24 V / 12.5 A Testdistance 10 m, Class A, 21-Apr-2017; ESVS 30, Rhode & Schwarz 60 JM221 50 0 0.2 0.5 1 2 5 10 20 MHz 40 Fig. 8a 110RCM150-24: Typ. disturbance voltage at the input (Vi = 110 V, Ii nom, resistive load, quasi peak and average) 30 20 10 0 30 110RCM300-24DMQF; Vi = 110 V, Vo = 24 V; Io = 12.5 A Class A, 20-Apr-2017 dBµV EN 55011 A qp JM220 80 EN 55011 A av 60 50 100 200 500 1000 MHz Fig. 9b 110RCM300-24: Typ. radiated disturbances in 10 m distance (Vi = 110 V, I i nom, resistive load, quasi peak). 40 20 0 0.2 0.5 1 2 5 10 20 MHz Fig. 8b 110RCM300-24: Typ. disturbance voltage at the input (Vi = 110 V, Ii nom, resistive load, quasi peak and average) BCD.00791 Rev AD, 4-May-2017 MELCHER The Power Partners. Page 10 of 15 RCM Series Data Sheet 150 /300 W DC-DC Converters Immunity to Environmental Conditions Table 7: Mechanical and climatic stress. Air pressure 800 – 1200 hPa Test method Standard Test conditions Db Damp heat test, cyclic EN 50155:2007, clause 12.2.5 IEC/EN 60068-2-30 Temperature: Cycles (respiration effect): Duration: 55 °C and 25 °C 2 2× 24 h Converter not operating Bd Dry heat test steady state EN 50155:2007, clause 12.2.4 IEC/EN 60068-2-2 Temperature: Duration: 70 °C 6h Converter operating Ad Cooling test steady state EN 50155:2007, clause 12.2.3 IEC/EN 60068-2-1 Temperature, duration Performance test –40 °C, 2 h +25 °C Conv. not operating -- Low temperature storage test EN 50155:2007, clause 12.2.14 IEC/EN 60068-2-1 Temperature, duration then start-up –40 °C, 16 h Conv. not operating Ka 1 Salt mist test sodium chloride (NaCl) solution EN 50155:2007, clause 12.2.10 IEC/EN 60068-2-11 class ST2 Temperature: Duration: 35 ±2 °C 16 h Converter not operating -- Shock EN 50155:2007 clause 12.2.11 EN 61373 sect. 10, class B, body mounted 1 Acceleration amplitude: Bump duration: Number of bumps: 5.1 gn 30 ms 18 (3 in each direction) Converter operating -- Simulated long life testing at increased random vibration levels EN 50155:2007 clause 12.2.11 EN 61373 sect. 8 and 9, class B, body mounted 2 Acceleration spectral density: Frequency band: Acceleration magnitude: Test duration: 0.02 g n2 /Hz 5 – 150 Hz 0.8 gn rm s 15 h (5 h in each axis) Converter operating 1 2 Status This test is is in preparation (not mandatory in EN 50155). Body mounted = chassis of a railway coach Temperatures Table 8: Temperature specifications, valid for an air pressure of 800 – 1200 hPa (800 – 1200 mbar) Temperature EN 50155 Class TX Characteristics TA Ambient temperature Case temperature TS Storage temperature 2 min max 10 minutes Converter operating 1 –40 70 85 –40 84 Not operational –55 85 2 TC 1 Conditions Unit °C Over temperature shutdown Measured at the measurement point TC; see Mechanical Data. Reliability Table 9: MTBF and device hours Ratings at specified case temperature between failures 1 Model Accord. to IEC 62380 110RCM150-24 1 MTBF Demonstrated hours Statistical values, based upon an average of 4300 working hours per year and in general field use over 5 years; upgrades and customer-induced errors are excluded. BCD.00791 Rev AD, 4-May-2017 MELCHER The Power Partners. Page 11 of 15 RCM Series Data Sheet 150 /300 W DC-DC Converters Mechanical Data Dimensions in mm. European Projection 75.45 68.2 40.9 29.5 11.15 JM205a 11.7 6.1 ∅ ∅4 4x) 5 Measuring point of case temperatureTC (4 x) 48 Measuring point of case temperatureTC 76.25 78 98 96 116 Fig. 10 Case RCM01, weight approx. 520 g, Aluminum, EP-powder coated BCD.00791 Rev AD, 4-May-2017 188.6 176.6 121.9 164.5 152.5 94.9 6 6 .5 ( 4. 12 7 36.1 38 JM203a Fig. 11 Case RCM02, weight approx. 820 g, Aluminum, EP-powder coated MELCHER The Power Partners. Page 12 of 15 RCM Series Data Sheet 150 /300 W DC-DC Converters Safety and Installation Instruction Installation Instruction Connectors and Pin Allocation of RCM150 - Input connector, 3 pins: Wago 236-403: Vi+, Vi–, PE; recommended wire section: 1.5 – 2.5 mm 2, 16 – 12 AWG - Output connector, 2 pins: Wago 236-402: Vo+, Vo–; recommended wire section: 1.5 – 2.5 mm 2, 16 – 12 AWG - Auxiliary connector: Phoenix Contact 1713883; recommended wire section: 0.2 – 1.5 mm 2, 24 – 16 AWG; pin allocation see fig. 12. These converters are components, intended exclusively for inclusion by an industrial assembly process or by a professionally competent person. Installation must strictly follow the national safety regulations in respect of the enclosure, mounting, creepage distances, clearances, markings and segregation requirements of the end-use application. Connection to the system shall only be effected with cables with suitable section (primary and secondary connector in cage clamp technique). The auxiliary connector shall be connected via the suitable female connector; see Accessories. No fuse is incorporated in the converter (except for option F). An external circuit breaker or a fuse in the wiring to one or both input pins. Vi– Vi+ PE R+. R– n.c. OK1 OK2 n.c. SD R R n.c. OK OK n.c. SD0 Vo+ Vo– Other installation methods may not meet the safety requirements. Check that PE is safely connected to protective earth. Fig. 12 Pin allocation of RCM150 Do not open the converters, or the warranty will be invalidated. Make sure that there is sufficient airflow available for convection cooling and that the temperature of the bottom plate is within the specified range. This should be verified by measuring the case temperature at the specified measuring point, when the converter is operated in the end-use application. TC max should not be exceeded. Ensure that a failure of the converter does not result in a hazardous condition. Connectors and Pin Allocation of RCM300 - Input connector, 3 pins: Wago 745-353: Vi–, Vi+, PE recommended wire section: 2.5 – 6 mm 2, 14 – 10 AWG - Output connector, 2 pins: Wago 745-602/006, Vo–, Vo+ recommended wire section: 2.5 – 16 mm 2, 14 – 6 AWG - Auxiliary connector: Phoenix Contact 1713883; recommended wire section: 0.2 – 1.5 mm 2, 24 – 16 AWG; pin allocation see fig. 13. Standards and Approvals The RCM Series converters are approved according to the safety standards IEC/EN 60950-1 and UL/CSA 60950-1 2nd Ed. • Class I equipment • Building in • Double or reinforced insulation based on 250 VAC or 240 VDC between input and output, and between input and the relay contacts (OK0, OK1, OK2). • Pollution degree 2 environment Vi– Vi+ PE R+. R– n.c. OK1 OK2 n.c. SD R R n.c. OK OK n.c. SD0 Vo– Vo+ They have been evaluated for: The converters are subject to manufacturing surveillance in accordance with the above mentioned UL standards and with ISO 9001:2008. Fig. 13 Pin allocation of RCM300 Table 10: Isolation Characteristic output 1 Electric strength test Input to case + output Output to case input OK contacts to case outputs Unit Factory test >1 s 4.2 2.86 1.0 2.86 2.86 2.86 kVDC AC test voltage equivalent to actual factory test 3.0 2.0 0.7 2.0 2.0 2.0 kVAC Insulation resistance >300 2 >300 2 >100 >300 >300 >300 MΩ Creepage distances 5.0 3.5 1.5 3.5 3.5 3.5 mm 1 2 Pretest of subassemblies in accordance with IEC/EN 60950 Tested at 500 VDC BCD.00791 Rev AD, 4-May-2017 MELCHER The Power Partners. Page 13 of 15 RCM Series Data Sheet 150 /300 W DC-DC Converters Cleaning Liquids and Protection Degree The converters are not hermetically sealed. In order to avoid possible damage, any penetration of liquids shall be avoided. The converters correspond to protection degree IP 30 for RCM150 and IP 20 for RCM 300. Railway Applications The RCM Series converters have been designed observing the railway standards EN 50155:2007 and EN 50121-32:2015. All boards are coated with a protective lacquer. The converters comply with the fire & smoke standard EN 45545, HL1 to HL3. Voltage Withstand Test The electric strength test is performed in the factory as routine test in accordance with EN 50514 and IEC/EN 60950 and should not be repeated in the field. The Company will not honor warranty claims resulting from incorrectly executed electric strength tests. BCD.00791 Rev AD, 4-May-2017 MELCHER The Power Partners. Page 14 of 15 (15) Accessories 3.7 Female Connector 4.7 0 10.2 RCM300 175.8 181.3 186 JM223 (98) 12 6 0 A suitable female connector is available. 15.7 RCM Series Data Sheet 150 /300 W DC-DC Converters 104 R 4 110 98 Fig. 14 Female connector 14 pins, HZZ00145-G Additional Heatsink (176.6) 4.2 R 5 A suitable heat sink for air cooling is available, if cooling by wall or a chassis mounting is not possible; see fig. 15 and fig. 16. Ø 5.65 0 10.2 RCM150 158.15 153.6 163.8 JM222 Ø 4.2 7 5. (152.5) R R 2 90 .5 84 78 (78) 12 6 0 3.7 12 Fig. 16 Additional heatsink for RCM 300 (HZZ00148-G) Fig. 15 Additional heatsink for RCM 150 (HZZ00147-G) NUCLEAR AND MEDICAL APPLICATIONS - These products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. Copyright © 2017, Bel Power Solutions Inc. All rights reserved. BCD.00791 Rev AD, 4-May-2017 MELCHER The Power Partners. www.belpowersolutions.com Page 15 of 15
HZZ00147-G 价格&库存

很抱歉,暂时无法提供与“HZZ00147-G”相匹配的价格&库存,您可以联系我们找货

免费人工找货