0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
MAP42-1012

MAP42-1012

  • 厂商:

    POWER-ONE

  • 封装:

  • 描述:

    MAP42-1012 - power supplies combines low cost and universal input - Power-One

  • 数据手册
  • 价格&库存
MAP42-1012 数据手册
MAP30/40/42 AC-DC Series Data Sheet Description Features • RoHS lead-solder-exempt compliant • Universal input 85-264 VAC • CE marked to Low Voltage Directive • Input transient & ESD compliance to EN61000-4-2/-3/-4 • Meets EN55022 conducted and radiated limits • Greater than 311,000 Hours MTBF • Remote sense (MAP30, MAP42) Power-One’s MAP30/40/42 Series of power supplies combines low cost and universal input in a board-only power solution to meet commercial and industrial requirements. Full international safety, EMI, and ESD compliance ensure worldwide acceptance. All units bear the CE Mark. Fixed frequency operation simplifies system level operation. The MAP30/40/42 Series is configured to the international standard 3.00" x 5.00" footprint. Input and output connections are made via popular single-row Molex connectors. Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements. Single-Output Model Selection MODEL OUTPUT VOLTAGE ADJUSTMENT RANGE MAXIMUM OUTPUT CURRENT PEAK OUTPUT CURRENT (NOTE 2) LINE REGULATION LOAD REGULATION RIPPLE & NOISE %p-p (NOTE 1) INITIAL SETTING ACCURACY MAP30-1005 MAP42-1005 MAP42-1012 MAP42-1024 NOTES: 5V 5V 12V/15V 24V/28V 4.7V to 5.8V 4.7V to 5.8V 11.0V to 18.0V 23.0V to 29.0V 6A 8A 3.4/2.7A (Note 3) 1.7/1.4A (Note 3) 8A 11A 4.6/3.7A (Note 3) 2.3/1.9A (Note 3) 0.2% 0.2% 0.2% 0.2% ±1% ±1% 1% 1% 1% 1% 1% 1% 4.9V to 5.1V 4.9V to 5.1V 11.9V to 12.1V 23.8V to 24.2V 1) Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. 2) Peak ratings may be used as maximum output current with 100 Linear Feet per Minute (LFM) forced air cooling. 3) MAP42-1012 output currents are expressed as 12V/15V operation. MAP42-1024 output currents are expressed as 24V/28V operation. Multiple-Output Model Selection – 40W CONTINUOUS OUTPUT POWER MODEL OUTPUT VOLTAGE ADJUSTMENT RANGE OUTPUT CURRENT PEAK OUTPUT CURRENT (NOTE 1) LINE REGULATION LOAD REGULATION RIPPLE & NOISE %p-p (NOTE 2) INITIAL SETTING ACCURACY MAP40-3000 MAP40-3100 MAP40-3101 MAP40-3105 MAP40-3500 MAP40-3003 NOTES : 1) 2) 3) 4) +5V +12V -12V +5V +12V -12V +5V +24V -12V +5V +12 -5V +5V +12V -12V +5V +15V -15V 4.75V to 5.50V Fixed Fixed 4.75V to 5.25V Fixed Fixed 4.75V to 5.25V Fixed Fixed 4.7V to 5.8V Fixed Fixed 4.7V to 5.8V Fixed Fixed 4.7V to 5.8V Fixed Fixed 3A 2A 0.3A 3A 2A 0.3A 3A 1A 0.3A 3A 2A 0.5A 5A 1A 0.3A 3A 1.5A 0.2A 5A 3.5A 0.5A 5A 3.5A 0.5A 5A 1.5A 0.5A 5A 3.5A 1.0A 6A 3.5A 0.5A 5A 3A 0.5A 0.2% 1% 1% 0.2% 1% 1% 0.2% 1% 1% 0.2% 1% 1% 0.2% 1% 1% 0.2% 1% 1% 2% 3.5% (Note 3) 2% (Note 4) 2% 3.5% (Note 3) 2% 2% 3.5% (Note 3) 2% 2% 3.5% (Note 3) 2% 2% 3.5% (Note 3) 2% 2% 3.5% (Note 3) 2% (Note 4) 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 4.9V to 5.1V 11.5V to 12.5V -11.4V to -12.6V 4.9V to 5.1V 11.5V to 12.5V -11.4V to -12.6V 4.9V to 5.1V 23.0V to 25.0V -11.5V to -12.5V 4.9V to 5.1V 11.5V to 12.5V -4.75V to -5.25V 4.9V to 5.1V 11.5V to 12.5V -11.4V to -12.6V 4.9V to 5.1V 14.7V to 15.3V -14.3V to -15.7V Peak loads for 30 seconds or less are acceptable, (10% duty cycle max.). Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. Quasi regulated output. See Regulation Curves for more information. Requires a minimum load of 0.5A on V1 or 0.3A on V2. REV. SEP 07, 2004 revised to JUN 19, 2006 Page 1 of 5 www.power-one.com MAP30/40/42 AC-DC Series Data Sheet Input Specifications PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Input Voltage - AC Input Frequency Brown Out Protection Hold-up Time Input Current Input Protection Inrush Surge Current Operating Frequency Continuous input range. MAP42 MAP30, MAP40 AC input. Lowest AC input voltage that regulation is maintained with full rated loads. Nominal AC Input Voltage (115VAC), full rated load. 90 VAC (40W load). Non-user serviceable internally located AC input line fuse. Internally limited by thermistor. Vin = 264VAC (one cycle). 25° C. Switching frequency of power supply (fixed frequency). 85 90 47 85 15 264 264 63 VAC Hz VAC ms ARMS APK kHz 1.2 38 23 25 30 Output Specifications PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Efficiency Minimum Loads Ripple and Noise Output Power Overshoot / Undershoot Regulation Transient Response Turn-on Delay Turn-on Rise Time Full load, 120VAC. Single output models; MAP30, MAP42. All multiple output models, see regulation graphs. Full load, 20 MHz bandwidth. Multiple output models with convection cooling. Output voltage overshoot/undershoot at turn-on, V1. Varies by output, total regulation includes: Line changes from 90-132 VAC or 175-264, changes in load starting at 20% load and changing to 100% load. Recovery time, to within 1% of initial set point due to a 50-100% load change, 4% max. deviation. (Main output only of multiple output units). Time required for initial output voltage stabilization. Time required for output voltage to rise from 10% to 90%. 70 0.0 % Amps See Model Selection Chart. 40 Watts 1 % See regulation graphs. 500 1 20 2 μs Sec ms Interface Signals and Internal Protection PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Overvoltage Protection Overload Protection Remote Sense MAP30-1005, MAP42-1005 MAP42-1012 MAP42-1024 Main output only of multiple output units. Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition. Total cable drop, single output models only. 5.8 20.0 32.0 5.8 130 6.8 22.0 37.0 6.8 V % 250 mV Safety, Regulatory, and EMI Specifications PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Agency Approvals Dielectric Withstand Voltage Electromagnetic Interference Input Transient Protection Insulation Resistance Leakage Current NOTES: UL60950. CSA 22.2 No. 60950. EN60950 (TUV). Input to output. FCC CFR title 47 part 15 sub-part B - conducted. EN55022 / CISPR 22 conducted (Note 1). EN55022 / CISPR 22 radiated (Note 2). EN61000-4-5 Level 3 Input to output. Per EN60950, 264VAC Approved. 2600 B B B Line to Line Line to Ground 1 2 7 500 750 VDC Class kV MΩ μA MAP42, MAP40-3100, 3001, 3105, 3500 MAP30-1005, MAP40-3000, MAP40-3003 1) MAP30-1005, MAP40-3000, MAP40-3003 meet Class A. 2) MAP40-3000, MAP40-3003, MAP3500 meet Class A. REV. SEP 07, 2004 revised to JUN 19, 2006 Page 2 of 5 www.power-one.com MAP30/40/42 AC-DC Series Data Sheet Environmental Specifications PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Altitude Operating Temperature Storage Temperature Temperature Coefficient Relative Humidity Shock Vibration Operating. Non-operating. Derate linearly above 50°C by 2.5% per °C to a maximum temperature of 70°C. 0°C to 70°C (after 15 minute warm-up). Non-condensing. Operating, peak acceleration. Random vibration, 10Hz to 2kHz, 3 axis. At 100% load: At 50% load: 0 0 -40 ±0.02 5 10k 40k 50 70 85 ±0.03 95 20 6 ASL Ft. ASL Ft. °C °C °C %/°C %RH G GRMS NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. REV. SEP 07, 2004 revised to JUN 19, 2006 Page 3 of 5 www.power-one.com MAP30/40/42 AC-DC Series Data Sheet MAP40-3500 TYPICAL QUASI REGULATION PERFORMANCE FOR +12V OUTPUT 14.25 13.75 12V OUTPUT VOLTAGE 13.25 12.75 +5V @ 5.0 Amps 12.25 +5V @ 3.0 Amps +5V @ 1.0 Amps +5V @ 0 Amps 11.25 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 11.75 12V OUTPUT CURRENT MAP40-3000/3100/3105 TYPICAL QUASI REGULATION PERFORMANCE FOR +12V OUTPUT 13.5 12V OUTPUT VOLTAGE 13.0 12.5 12.0 +5V @ 3.0 Amps 11.5 +5V @ 1.8 Amps +5V @ 0.6 Amps +5V @ 0 Amps 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 11.0 12V OUTPUT CURRENT MAP40-3003 TYPICAL QUASI REGULATION PERFORMANCE FOR +15V OUTPUT 17.0 16.5 16.0 15V OUTPUT VOLTAGE 15.5 15.0 14.5 14.0 13.5 0 0.15 0.3 0.45 0.6 0.75 0.9 1.05 1.2 1.35 1.5 +5V @ 3.0 Amps +5V @ 1.8 Amps +5V @ 0.6 Amps +5V @ 0 Amps 15V OUTPUT CURRENT REV. SEP 07, 2004 revised to JUN 19, 2006 Page 4 of 5 www.power-one.com MAP30/40/42 AC-DC Series Data Sheet OVERALL SIZE: 5.00" x 3.00" x (see table) (127.0mm x 76.2mm x see table) WEIGHT: 0.6 lb (0.26 kg) J1 NEUTRAL PIN 1 MAP30 J2 PIN 7 N/C V1 V1 GND GND +Sense -Sense MAP40 J2 PIN 6 V2 V1 V1 GND GND V3 MAP42 J2 PIN 6 V1 V1 GND GND +Sense -Sense LINE PIN 2 J3 SAFETY EARTH GROUND (0.250" x 0.032" FASTON) PIN 1 PIN 1 PIN 1 J1/J2 MATES WITH MOLEX (SERIES 2139 or SERIES 41695) .156" (4mm) CENTER CRIMP TERMINAL HOUSING OR EQUIVALENT MAP30/40/42 SERIES HEIGHT Single Output Models Model MAP30-1005 MAP42-1005 MAP42-1012 MAP42-1024 Height 1.16" (29.5) 1.25" (31.8) 1.25" (31.8) 1.25" (31.8) Multiple Output Models Model MAP40-3000 MAP40-3003 MAP40-3100 MAP40-3101 MAP40-3105 MAP40-3500 Height 1.16" (29.5) 1.16" (29.5) 1.25" (31.8) 1.25" (31.8) 1.25" (31.8) 1.60" (40.6) www.power-one.com REV. SEP 07, 2004 revised to JUN 19, 2006 Page 5 of 5
MAP42-1012 价格&库存

很抱歉,暂时无法提供与“MAP42-1012”相匹配的价格&库存,您可以联系我们找货

免费人工找货