0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
CERS-0512M

CERS-0512M

  • 厂商:

    POWER-SYSTEMS

  • 封装:

  • 描述:

    CERS-0512M - DC-DC Converter UNIT 1.5 W REGULATED DC-DC CONVERTER - Power Systems GmbH+Co.KG

  • 数据手册
  • 价格&库存
CERS-0512M 数据手册
DC-DC Converter UNIT CER Series (1.5 W REGULATED DC-DC CONVERTER) FEATURES 1000VDC ISOLATION HIGH EFFICIENCY SIX-SIDED SHIELD TO REDUCE EMI LOW COST NO EXTERNAL COMPONENTS REQUIRED UP TO 1.5W REGULATED OUTPUT POWER DUAL IN LINE PACKAGE 100% BURNED IN LOW NOISE MTBF > 850,000 HOURS OUTPUT SPECIFICATIONS Voltage Setpoint Accuracy Temperature Coefficient Ripple & Noise (20MHz BW) Line Regulation1 Load Regulation 2 INPUT SPECIFICATIONS +/-2% max +/-0.03%/ C O Input Voltage Range Input Filter +/-10% max Pi Network 100mVp-p max +/-0.5% max +/-0.5% max Current Limit Protection Automatic GENERAL SPECIFICATIONS Efficiency Isolation Voltage3 Isolation Resistance Switching Frequency Isolation Capacitance MTBF Weight 58% min 1000 VDC min 9 10 ohms min 50 KHz min 80pF max 850,000 Hours 12.0g-14.4g Six-Sided Shield Case 31.8mm*20.3mm*10.2mm Short Circuit Protection Short Circuit Restart ENVIRONMENTAL SPECIFICATIONS Operating Temperature Storage Temperature Cooling -25 C to +71 C O O O -55 C to +125 C O Free-Air Convection ALL SPECIFICATIONS TYPICAL AT NOMINAL LINE, FULL LOAD , AND 25 O Case Material Case Size C UNLESS OTHERWISE NOTED. 1 2 3 High Line to Low Line. Load Regulation is for output load current change from 10% to 100%. For 60 seconds www.Power-Systems.de Page: 1 / 5 Version: 4-Oct-02 DC-DC Converter UNIT CER Series (1.5 W REGULATED DC-DC CONVERTER) SELECTION GUIDE 1.5W OUTPUT MODEL NUMBER INPUT (VDC) 4.5-5.5 4.5-5.5 4.5-5.5 4.5-5.5 4.5-5.5 10.8-13.2 10.8-13.2 10.8-13.2 10.8-13.2 10.8-13.2 21.6-26.4 21.6-26.4 21.6-26.4 21.6-26.4 21.6-26.4 OUTPUT (VDC) 5 12 15 +/-12 +/-15 5 12 15 +/-12 +/-15 5 12 15 +/-12 +/-15 OUTPUT (mA) 300 125 100 +/-63 +/-50 300 125 100 +/-63 +/-50 300 125 100 +/-63 +/-50 INPUT CURRENT(mA) FULL LOAD NO LOAD 40 40 40 40 40 15 15 15 15 15 10 10 10 10 10 60 61 61 61 61 61 64 64 64 66 63 66 66 66 67 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 VOLTAGE VOLTAGE CURRENT EFF (%) ISOLATION (VDC) CERS-0505M CERS-0512M CERS-0515M CERD-0512M CERD-0515M CERS-1205M CERS-1212M CERS-1215M CERD-1212M CERD-1215M CERS-2405M CERS-2412M CERS-2415M CERD-2412M CERD-2415M 500 490 490 490 490 205 195 195 195 190 100 95 95 95 93 Note: Other input to output voltages may be available. Please contact factory. www.Power-Systems.de Page: 2 / 5 Version: 4-Oct-02 DC-DC Converter UNIT CER Series (1.5 W REGULATED DC-DC CONVERTER) SIMPLIFIED SCHEMATIC SINGLE OUTPUT +Vin OSCILLATOR DRIVER REGULATOR DUAL OUTPUT +Vout +Vin OSCILLATOR DRIVER REGULATOR +Vout Com. -Vout -Vin -Vout -Vin REGULATOR MECHANICAL DIMENSIONS & RECOMMENDED FOOTPRINT DETAILS PIN 1 & 24 2 & 23 3 & 22 10 & 15 11 & 14 12 & 13 SINGLE +Vin NC NC -Vout +Vout -Vin DUAL +Vin -Vout Common Common +Vout -Vin www.Power-Systems.de Page: 3 / 5 Version: 4-Oct-02 DC-DC Converter UNIT CER Series (1.5 W REGULATED DC-DC CONVERTER) TYPICAL APPLICATIONS SINGLE OUTPUT INPUT +Vin +Vout DUAL OUTPUT INPUT +Vin +Vout OUTPUT OUTPUT LOAD1 DC-DC CONVERTER -Vin -Vout LOAD DC-DC CONVERTER -Vin Common LOAD2 -Vout TYPICAL PERFORMANCE CUREVES Specifications typical at ta=25 OC,nominal input voltage , rated output current unless otherwise specified. OUTPUT LOAD vs EFFICIENCY 80% OUTPUT LOAD vs OUTPUT VOLTAGE 60% 40% 20% 0% 0% 20% OUTPUT VOLTAGE CHANGE(%) 100% 10% 5% 0% -5% -10% 0% 20% 40% 60% 80% 100% EFFICIENCY(%) SAFE OPERATING AREA 40% 60% 80% OUTPUT LOAD(%) TEMPERATURE DERATING 2.0 OUTPUT LOAD(%) INPUT VOLTAGE vs EFFICIENCY 100% OUTPUT POWER(W) EFFICIENCY(%) 1.5 1.0 0.5 0.0 -25 0 25 50 70 100 80% 60% 40% 20% 0% -10 -5 Nom 5 10 TA(degree C) INPUT VOLTAGE(%) www.Power-Systems.de Page: 4 / 5 Version: 4-Oct-02 DC-DC Converter UNIT CER Series (1.5 W REGULATED DC-DC CONVERTER) CER SERIES APPLICATION NOTES: EXTERNAL CAPACITANCE REQUIREMENTS: No external capacitance is required for operation of the CER series. To meet the reflected ripple requirements of the converter, an input impedance of less than 0.5 ohm from DC to 100KHz is required. External output capacitance is not required for operation, however it is recommended that 10uF tantalum and 0.1uF ceramic capacitance be selected for reduced system noise. Additional output capacitance may be added for increased filtering, but should not exceed 220uF. Negative Outputs: A negative output voltage may be obtained by connecting the +OUT to circuit ground and connecting –OUT as the negative output. FOR MORE INFORMATION CALL: Power Systems – The Power Solution Ilsfeld-Auenstein ( Germany ) Dörnet 8 E-mail: Info@Power-Systems.de Tel: + 49 / 70 62 / 67 59 – 6 Fax: + 49 / 70 62 / 67 59 -80 Home Page: www.Power-Systems.de www.Power-Systems.de Page: 5 / 5 Version: 4-Oct-02
CERS-0512M 价格&库存

很抱歉,暂时无法提供与“CERS-0512M”相匹配的价格&库存,您可以联系我们找货

免费人工找货