0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
CWD-1205A12M

CWD-1205A12M

  • 厂商:

    POWER-SYSTEMS

  • 封装:

  • 描述:

    CWD-1205A12M - DC-DC Converter UNIT - Power Systems GmbH+Co.KG

  • 数据手册
  • 价格&库存
CWD-1205A12M 数据手册
DC-DC Converter UNIT CW SERIES (10W~12W Wide Input Range) FEATURES •10W to 12W dil package •9-18V, 18-36V, 36-72V Wide Input Range •100% Burned in •High efficiency •UL 94V-0 Package material •Costum solutions available •RoHS compliant •3 Years warranty OUTPUT SPECIFICATIONS Voltage Set point Accuracy Temperature Coefficient Ripple & Noise (20MHz BW)1 Line Regulation2 Load Regulation3 Minimum Load Short Circuit Protection Short Circuit Restart Transient Response5 Over Load Protection +/-2% max +/-0.05%/ °C 100mVp-p max +/-0.5% max +/-0.5% max 20% of Full Load Continuous Automatic 350uS max 100% ~180% INPUT SPECIFICATIONS Input Voltage Range Input Filter Protection 2:1 Input Range Pi Network Fuse Recommended GENERAL SPECIFICATIONS Efficiency Isolation Voltage4 Isolation Resistance Isolation Capacitance Switching Frequency MTBF6 Weight Case Material Case Size Potting Material Conducted Emissions Radiated Emissions Remote On / Off -On -Off -Off idle current 78% min 1500 VDC min 109 ohms min 2200pF max 400 KHz Typ >600,000 Hours 18.5g Typ Five-sided shield case 31.8mm*20.3mm*12.2mm Epoxy (UL94-V0) EN55022 Class A EN55022 Class A 3.0…12V/DC or open circuit (referenced to-Vin) 0…1.2V/DC or short circuit (pin 1 and pin 2/3) 2.5 mA ENVIRONMENTAL SPECIFICATIONS Operating Temperature Storage Temperature Case Temperature Humidity Cooling -40 °C to +85 °C -55 °C to +105 °C 95% °C max 95% max Free-Air Convection ALL SPECIFICATIONS TYPICAL AT NOMINAL LINE, FULL LOAD , AND 25 °C UNLESS OTHERWISE NOTED. [1] Measured with 1uF ceramic capacitor connect to the output pins. [2] High Line to Low Line. [3] Load Regulation is for output load current change from 20% to 100%. [4] 1500Vdc for 10 seconds [5] 25% Step Load Change. [6] MIL-HDBK-217F @25 °C , Ground Benign. Power Systems – The Power Solution Web: Email: www.Power-Systems.de Info@Power-Systems.de Page (1) Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 800 Version 1.0, 20th May 2008 All specifications are subject to change without notice. DC-DC Converter UNIT CW SERIES (10W~12W Wide Input Range) ●SELECTION GUIDE(1) 2:1 10W~12W OUTPUT MODEL[7] NUMBER INPUT VOLTAGE (VDC) 9-18 9-18 9-18 9-18 9-18 9-18 9-18 9-18 18-36 18-36 18-36 18-36 18-36 18-36 18-36 18-36 36-75 36-75 36-75 36-75 36-75 36-75 36-75 36-75 OUTPUT VOLTAGE (VDC) 2.5 3.3 5 12 15 +/-5 +/-12 +/-15 2.5 3.3 5 12 15 +/-5 +/-12 +/-15 2.5 3.3 5 12 15 +/-5 +/-12 +/-15 OUTPUT CURRENT (mA) 3000 3000 2400 1000 800 +/-1200 +/-500 +/-400 3000 3000 2400 1000 800 +/-1200 +/-500 +/-400 3000 3000 2400 1000 800 +/-1200 +/-500 +/-400 INPUT[8] CURRENT(mA) FULL LOAD 802 1025 1190 1204 1204 1235 1190 1204 401 513 602 602 590 618 595 595 201 256 298 301 294 309 298 298 NO LOAD 70 70 70 70 70 70 70 70 35 35 35 35 35 35 35 35 25 25 25 25 25 25 25 25 EFF (%)[9] PACKAGE Capacitor Load max CWS-1202.5A10M CWS-1203.3A10M CWS-1205A12M CWS-1212A12M CWS-1215A12M CWD-1205A12M CWD-1212A12M CWD-1215A12M CWS-2402.5A10M CWS-2403.3A10M CWS-2405A12M CWS-2412A12M CWS-2415A12M CWD-2405A12M CWD-2412A12M CWD-2415A12M CWS-4802.5A10M CWS-4803.3A10M CWS-4805A12M CWS-4812A12M CWS-4815A12M CWD-4805A12M CWD-4812A12M CWD-4815A12M 78 80 84 83 83 81 84 83 78 80 83 83 85 81 84 84 78 80 84 83 85 81 84 84 A A A A A A A A A A A A A A A A A A A A A A A A 1000uF 1000uF 1000uF 220uF 220uF +/-670uF +/-100uF +/-47uF 1000uF 1000uF 1000uF 220uF 220uF +/-670uF +/-100uF +/-47uF 1000uF 1000uF 1000uF 220uF 220uF +/-670uF +/-100uF +/-47uF Note: Other input to output voltages may be available. Please contact factory. 7 CW*-*****A12M AND CW*-*****A10M (Isolation For 1500 VDC) 8 NOMINAL INPUT VOLTAGE. 9 NOMINAL INPUT VOLTAGE, FULL LOAD. Power Systems – The Power Solution Web: Email: www.Power-Systems.de Info@Power-Systems.de Page (2) Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 800 Version 1.0, 20th May 2008 All specifications are subject to change without notice. DC-DC Converter UNIT CW SERIES (10W~12W Wide Input Range) ●MECHANICAL DIMENSIONS 20.3[0.80] PACKAGE “A” 2.54[0.10] PIN 23 22 2 3 SINGLE Remote On/Off -Vin NC NC +Vout -Vout +Vin DUAL Remote On/Off -Vin Common -Vout +Vout Common +Vin 1 BOTTOM VIEW 16 14 9 11 SIDE VIEW 31.8[1.25] 2&3 9 11 15.24[0.60] 5.08[0.20] 12.2[0.48] 3.81[0.15] 14 16 22 & 23 All dimensions are in mm[inchs] NOTE: Pin Size is Tolerance 0.6Φ ±0.05mm All Dimensions In mm(Inches) Tolerance .X or .XX= ±0.5mm PACKAGE “A” 2.54mm ● RECOMMENDED FOOTPRINT DETAILS 2.54mm 23 22 16 14 123 9 11 TOP VIEW ●SIMPLIFIED SCHEMATIC SINGLE OUTPUT DUAL OUTPUT Power Systems – The Power Solution Web: Email: www.Power-Systems.de Info@Power-Systems.de Page (3) Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 800 Version 1.0, 20th May 2008 All specifications are subject to change without notice. DC-DC Converter UNIT CW SERIES (10W~12W Wide Input Range) ●TYPICAL PERFORMANCE CUREVES Specifications typical at ta=25°C, nominal input voltage, rated output current unless otherwise specified. ●OUTPUT LOAD VS EFFICIENCY ●TEMPERATURE DERATING EFFICIENCY(%) 80.0 60.0 40.0 20.0 0.0 0 20 40 60 80 100 % OF RATED LOAD(%) SAFE OPERATING AREA ●INPUT FUSE SELECTION GUIDE 9-18V INPUT VOLTAGE(VDC) 3000mA Slow-Blow Type 18-36V INPUT VOLTAGE(VDC) 1200mA Slow-Blow Type 36-75V INPUT VOLTAGE(VDC) 600mA Slow-Blow Type INPUT +Vin +Vout OUTPUT Fuse DC-DC CONVERTER -Vin -Vout Note: Certain applications may require the installation of external fuse in front of the input. CW 10W~12W SERIES APPLICATION NOTES: EXTERNAL CAPACITANCE REQUIREMENTS: No external capacitance is required for operation of the CW 10W~12W series. To meet the reflected ripple requirements of the converter, an input impedance of less than 0.5 ohm from DC to 100KHz is required. External output capacitance is not required for operation, however it is recommended that 10uF tantalum and 0.1uF ceramic capacitance be selected for reduced system noise. We can offer EMC-Filter According to EN55011/22 Class A. Power Systems – The Power Solution Web: Email: www.Power-Systems.de Info@Power-Systems.de Page (4) Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 800 Version 1.0, 20th May 2008 All specifications are subject to change without notice.
CWD-1205A12M 价格&库存

很抱歉,暂时无法提供与“CWD-1205A12M”相匹配的价格&库存,您可以联系我们找货

免费人工找货