0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
CXA-L0505-NJL

CXA-L0505-NJL

  • 厂商:

    POWER-SYSTEMS

  • 封装:

  • 描述:

    CXA-L0505-NJL - DC-AC INVERTER UNIT 3.0W SINGLE OUTPUT - Power Systems GmbH+Co.KG

  • 数据手册
  • 价格&库存
CXA-L0505-NJL 数据手册
DC-AC INVERTER UNIT CXA-L05XX-NJL SERIES (3.0W SINGLE OUTPUT) (PRELIMNARY, STANDARD) DESCRIPTION : This DC to AC Inverter was developed for notebook computer and many other low LCD Backlight power supply as low profile applications, either for Note Book PC or Industrial. APPLICABLE LCD: 6 to 10 inches single lamp type Lamp Voltage 600V Lamp Current 5mA FEATURES : High Efficiency (85%) Fuse protection High Efficiency Low noise with voltage resonant circuit TEMPERATURE & HUMDITY : Operating Temperature Range Storage Temperature Range Humidity 0°C ~ +60°C -30 °C ~ +85°C 95 %RH max DIMENSIONS : 80.5 max (3) (2) (8) 60±0.2 Unit: mm Weight: 11.0g typ. 20.5max 14±0.2 2-φ2.2±0.1 1 2 1 2-R1.1±0.1 3 8 max 1 max No. 1 2 3 Part Discription PCB Connector CN1 Connector CN2 Qty. 1 1 1 Material UL94V-0 (FR-4 or CEM-3) 53261-0590 SM02(8.0)B-BHS-1 16±0.2 1 CN1 CN2 Note t=1.0mm Molex JST Power Systems – The Power Solution Web: Email: www.Power-Systems.de Info@Power-Systems.de Page ( 1 /4 ) Address: Dörnet 8 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 80 VER, 28 October 2003 All specification are subject to change without notice. DC-AC INVERTER UNIT CXA-L05XX-NJL SERIES (3.0W SINGLE OUTPUT) Input Side CN1: (PRELIMNARY, STANDARD) Output Side CN2: Pin No. Symbols CN CN CN CN CN 1-1 1-2 1-3 1-4 1-5 Vin GND N.C. Ratings CXA-L0505-NJL CXA-L0512-NJL CXA-L0524-NJL 5V 12V 24V 0V 0V 0V - Pin No. Symbols CN 2-1 VHIGH N.C. CN 2-2 CN 2-3 VLOW Ratings 600 Vrms (0V) ELECTRICAL CHARACTERISTICS: CXA-L0505-NJL Ite ms Output Current Input Current Fre quency Open Circuit Voltage CXA-L0512-NJL Symbols Iout1 Iout2 Iin F Vope n Conditions Vin (V) Ta (°C) RL (KΩ ) 5±0.05 18~28 120 110~130 5±0.25 0~60 ∞ Spe cifica tion Unit Min. Typ. Ma x. 4.5 5.0 5.5 mArms 4.0 5.0 6.0 720 1000 mA DC 33 40 47 kHz 1400 1500 Vrms Conditions Ite m s Output Curre nt Input Curre nt Fre que ncy Ope n Circuit V olta ge CXA-L0524-NJL Spe cifica tion Unit M in. 4.5 4.0 33 Typ. Ma x . 5.0 5.0 300 40 5.5 6.0 500 47 m Arm s m A DC kHz V rm s Sym bols Vin (V ) Ta (°C) Iout1 Iout2 Iin F Vope n 12±0.12 18~ 28 RL (K ⎠ ) 120 110~130 12±0.6 0~60 ∞ 1400 1500 Items Output Curre nt Input Curre nt Fre que ncy Ope n Circuit Volta ge Symbols Iout1 Iout2 Iin F Vope n Conditions Vin (V) Ta (°C) RL (K⎠ ) 24±0.24 18~28 120 110~130 24±1.2 0~60 ∞ Spe cifica tion Unit Min. Typ. Ma x . 4.5 5.0 5.5 mArm s 4.0 5.0 6.0 150 250 mA DC 26 32 38 kHz 1400 1500 Vrm s Power Systems – The Power Solution Web: Email: www.Power-Systems.de Info@Power-Systems.de Page ( 2 /4 ) Address: Dörnet 8 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 80 VER, 28 October 2003 All specification are subject to change without notice. DC-AC INVERTER UNIT CXA-L05XX-NJL SERIES (3.0W SINGLE OUTPUT) (PRELIMNARY, STANDARD) APPLICATION (for example) None Dimming Type Vin CN1-1(Vin) CN1-2(GND) CN1-3(NC) CN1-4(NC) CN1-5(NC) CN2-1(Iout) CXA-L0512-VJL SM02(8.0)B-BHS (JST) CCFL RL CN2-3(Iout-ret) TEST CIRCUIT: lin A Vin V Vin - CN1-1 (Vin) CN1-2 (GND) CN1-3 (NC) CN1-4 (NC) CN1-5 (NC) CN2-1 (VHIGH) NC NC NC RL Iout CN2-3 (VLOW) A V F 1000:1 Power Systems – The Power Solution Web: Email: www.Power-Systems.de Info@Power-Systems.de Page ( 3 /4 ) Address: Dörnet 8 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 80 VER, 28 October 2003 All specification are subject to change without notice. DC-AC INVERTER UNIT CXA-L05XX-NJL SERIES (3.0W SINGLE OUTPUT) (PRELIMNARY, STANDARD) Note 1. Note 2. For circuit connection, please prefer to test circuit diagram. Please use minimum of 2mm clearance (all directions) between inverter high voltage area and any conductors. Please refer to mechanical drawing for marking of high voltage area. Open voltage (strike voltage) is measured across the transformer secondary winding at no load as the reading at the output connector would be less than the actual value. If the start up voltage falls below Cold Cathode Tube strike voltage, the CCFL will not light up easily specially at lower ambient temperature. Please review mounting instruction to avoid any abnormal operation due to coupling/leakage capacitance of inverter high voltage area to any surrounding conductor. For operation in non-isolated configuration, please connect CN2-3 (V-Low) to input return (GND) as the output of DC/AC inverter is electrically isolated from input. For proper operation of circuit protection (FUSE or IC PROTECTOR) of CXA-L0505-NJL, please use minimum of 2A capacity for input power supply and 1A for CXA-L0512-NJL and CXA-L0524-NJL.. Note 3. Note 4. Note 5. Note 6. Power Systems – The Power Solution Web: Email: www.Power-Systems.de Info@Power-Systems.de Page ( 4 /4 ) Address: Dörnet 8 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 80 VER, 28 October 2003 All specification are subject to change without notice.
CXA-L0505-NJL 价格&库存

很抱歉,暂时无法提供与“CXA-L0505-NJL”相匹配的价格&库存,您可以联系我们找货

免费人工找货