0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
QUANTAFOB-4S1

QUANTAFOB-4S1

  • 厂商:

    RFSOLUTIONS

  • 封装:

  • 描述:

    1 CH REMOTE CONTROL SYS 12-30VDC

  • 数据手册
  • 价格&库存
QUANTAFOB-4S1 数据手册
QUANTAFOB Remote Control System Features • Up to 100m Range • 433MHz FM Technology • 1 – 4 Channels each 1000W • Waterproof Receiver (IP68) • High Security RF Protocol • 4 Changeover Relays 5A @ 230Vac • Outputs Momentary or Latching • Any Switch Map to Any Relay • Systems supplied ’ready to Go’ • FCC Certified and CE Compliant Applications • General Purpose Remote Switching • Electric Gates • Roller Shutter Doors • Garden Lighting. Description A versatile general purpose Remote Control System for many different applications. Housed in a rugged IP68 weatherproof enclosure, The new QUANTAFOB system is ideally suited to any remote switch requirement. Each receiver has 4 relays, using the ‘easylearn’ process each relay can be controlled from any switch on any transmitter. Additional transmitters may be added to the system using the same ‘easy-learn’ process. Installation is by screw terminals to the power supply and the output relay contacts. The output relays are activated by the button press on the transmitter encoder. DS QUANTAFOB-2 QUANTAFOB Systems Part Numbers Part Number Description Power Supply Frequency QUANTAFOB-4S1 1 ch System 12-30Vac/dc 433 QUANTAFOB-4S2 2 ch System 12-30Vac/dc 433 QUANTAFOB-4S3 3 ch System 12-30Vac/dc 433 QUANTAFOB-4S4 4 ch System 12-30Vac/dc 433 Part Number Description Range* Frequency FOBBER-4T1 1 Sw 100m 433 FOBBER-4T2 2 Sw 100m 433 FOBBER-4T3 3 Sw 100m 433 FOBBER-4T4 4 Sw 100m 433 FOBBER-4T6 6 Sw 100m 433 FOBBER-4T8 8 Sw 100m 433 Custom Systems Fobbers can be customised with logo, colour or complete custom plastic housing for unique Branding QUANTAFOB Relay Outputs The receiver provides 4 changeover relay switches each capable of switching up to 1.2KW (5A @ 230V). Each relay is independent and separately controlled, and can therefore be used to switch most voltages either ac or dc. Each output relay provides an isolated switch. Connections are Common (COM), Normally Open (NO) and Normally Closed (NC). NC COM NO NC COM NO Relay Connections when Transmitter NOT Operating Relay Connections when Transmitter OPERATING Installation Below is a simple example showing one possible way to wire a relay in order to provide switched power to an external load: When the relay is energised the ‘COM’ connects to ’NO’ and power is applied to the Load. 1. Open the enclosure by removing fixing screws from the enclosure 2. Remove the antenna and slide out the circuit board. 3. Connect the power supply screw terminals 12-32V ac or dc to the supply terminals. 4. Wire your desired connections to the relay switches 5. Once wiring is complete, use the handheld QUANTA transmitter to switch the outputs on and off. 6. As supplied, the transmitter will operate the outputs - Sw 1 to output 1, Sw 2 to output 2 etc. 7. Change the output functions to latching, / Momentary Operation. NO COM 12V NC LOAD Relay Receiver 0V Relay Relay 12V 0V Supply Terminals QUANTAFOB Configuring Receiver Relay Outputs Receivers can be used for many applications. The link pins LK1 and LK2 set the action of the relays 1/2 sec Mom = Relay will operate for half a second no matter how long a transmitter switch is operated Mom = Relay will operate for as long as transmitter switch operated Latch = Relay will toggle ON/OFF on each transmitter button press Learn Switch Link Pins LK1 LK2 Link Positions LK1 LK2 Fitted Fitted Fitted Open Open Open Fitted Open Relays RLY 1 1/2 sec Mom Mom RLY 2 1/2 sec Mom Mom RLY 3 1/2 sec Mom Latch RLY 4 1/2 sec Mom Latch Mom Latch Mom Latch Mom Latch Mom Latch QUANTAFOB Advanced operation - Pairing a transmitter button with a With this system, you can pair together any individual transmitter button with any receiver relay output. Without opening either enclosure. All you need is a magnet. 1. Briefly (less than 1 second) place the transmitter next to the receiver in the position shown and then remove it. 2. The receiver will buzz once (One beep means the receiver unit is ready to allocate a transmitter to relay switch 1) 3. Press the button on the transmitter which you wish to pair 4. The receiver will beep twice to confirm pairing 5. Repeat for any additional transmitter switches NOTE: Each receiver has a maximum memory for up to 28 pairings, these can be from any buttons on any transmitters! NOTE: The switch that is operated by the magnet is on the left of the antenna. Advanced Note: It is possible to select relay outputs 2-4, by repeating step 3 and counting the number of beeps. 2 beeps for relay 2, 3 for 3 and 4 f or 4. Advanced operation - Erasing receiver memory with a 1. Hold the magnet in the position shown for ~5 seconds. 2. The receiver will sound a long ’Beep’ to confirm erased QUANTAFOB Advanced Operation - Pairing a transmitter button using the internal learn switch To pair a new transmitter switch follow this procedure Open the receiver enclosure and extract the Circuitboard assembly Note!: Any transmitter button can be configured to operate any of the receiver relays. 1. Select the receiver output relay to learn to: 2. Briefly press the receiver Pairing switch (S2) once 3. The Learn LED will flash once to indicate relay 1 is selected 4. After the LED stops flashing, press the Learn switch again to select the next relay channel 5. Repeat step 4 until the required relay is selected. 6. Press the button on the transmitter you want to learn to the chosen relay. 7. The Learn LED will flash to indicate Pairing is complete. Pairing a Transmitter to a Receiver The only limitation is that each receiver has a maximum memory for up to 30 pairings, these can be from the same or any number of transmitters. Erasing Receivers Memory 1. Press and hold the receiver Learn Switch for approx 10 seconds. 2. When the Learn LED turns ON all memory is erased NOTE: You cannot erase individual Tx encoders QUANTAFOB Technical specifications Transmitters: FOBBER Transmitter Enclosure Rating: Battery Type: Battery Life: Dimensions: Standard IP68 CR2032 (supplied) 2 years @ approx. 50 1/2second presses p/day 90 x 54 x 27 mm Changing the Battery: Remove the 2 enclosure screws. replace battery, taking care of contacts and the battery polarity Receiver Unit Enclosure Rating: IP68 Dimensions: 130 x 112 x 42 mm (not including antenna) Operating Temperature:-10 to +50o Celsius. *The relay contacts in this unit are for functional use only and must not be used for isolation purposes QUANTAFOB Mechanical Dimensions 50.00 10.00 59.00 46.00 All Dimensions in mm 82.00 RED Directive This product meets the requirements of directive 2014/53/EU. Full declaration is available at:https://www.rfsolutions.co.uk/certification-i59 RF Solutions Ltd. Recycling Notice Waste Batteries and Accumulators Meets the following EC Directives: Directive 2006/66/EC DO NOT Discard with normal waste, please recyROHS Directive 2002/95/EC Specifies certain limits for hazardous substances. cle. Where batteries are fitted, before recycling the product, the batteries must be removed and disposed of at a licensed collection point. Environment Agency producer registration number: WEE/JB0104WV. WEEE Directive 2002/96/EC Waste electrical & electronic equipment. This product must be disposed of through a licensed WEEE collection point. RF Solutions Ltd., fulfills its WEEE obligations by membership of an approved compliance scheme. Disclaimer: Whilst the information in this document is believed to be correct at the time of issue, RF Solutions Ltd does not accept any liability whatsoever for its accuracy, adequacy or completeness. No express or implied warranty or representation is given relating to the information contained in this document. RF Solutions Ltd reserves the right to make changes and improvements to the product(s) described herein without notice. Buyers and other users should determine for themselves the suitability of any such information or products for their own particular requirements or specification(s). RF Solutions Ltd shall not be liable for any loss or damage caused as a result of user’s own determination of how to deploy or use R F Solutions Ltd’s products. Use of RF Solutions Ltd products or components in life support and/or safety applications is not authorised except with express written approval. No licences are created, implicitly or otherwise, under any of RF Solutions Ltd’s intellectual property rights. Liability for loss or damage resulting or caused by reliance on the information contained herein or from the use of the product (including liability resulting from negligence or where RF Solutions Ltd was aware of the possibility of such loss or damage arising) is excluded. This will not operate to limit or restrict RF Solutions Ltd’s liability for death or personal injury resulting from its negligence.
QUANTAFOB-4S1 价格&库存

很抱歉,暂时无法提供与“QUANTAFOB-4S1”相匹配的价格&库存,您可以联系我们找货

免费人工找货