0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
BP5039A_10

BP5039A_10

  • 厂商:

    ROHM(罗姆)

  • 封装:

  • 描述:

    BP5039A_10 - Non-Isolated AC/DC Converter - Rohm

  • 数据手册
  • 价格&库存
BP5039A_10 数据手册
Data Sheet 100VAC Input/24VDC (200mA) Output Non-Isolated AC/DC Converter BP5039A Absolute Maximum Ratings Parameter Input voltage Maximum output current ESD endurance Maximum surface temperature Operating Temperature range Storage temperature range Symbol Vcc IoMAX Vsurge TcMAX Topr Tstg Limits 170 200 2 105 −20 to +80 −25 to +105 Unit V mApk kV °C °C °C 19.5MAX. Dimensions (Unit : mm) 35.0MAX. Mark Side 1 3 5 7 7.62 1 . 3 ±0 . 2 2.54�11=27.94 10 12 0 . 2 5 ±0 . 0 5 4.85MAX. 4.25MAX. 0 . 5 ±0 . 1 3.6MAX. 5.08 9.1MAX. Electrical Characteristics Symbol Min. Parameter Input voltage range 113 Vi Output voltage 22 Vo Output current 0 Io Line regulation −0.50 Vr Load regulation −0.50 Vl Output ripple voltage − Vp Power conversion efficiency 70 η Output current at 200 Io1 overcurrent 150 Io2 Typ. 141 24 − 0.30 0.25 0.07 82 245 220 Max. 170 26 200 0.50 0.50 − − − Unit V V mA V V Vp-p % mA mA Conditions DC (80 to 120VAC) Vi=141V, Io=100mA Vi=141V ∗1 Vi=113 to 170V, Io=100mA Vi=141V, Io=0 to 100mA ∗2 Vi=141V, Io=100mA Vi=141V, Io=200mA ∗2 Vi=170V, Output short, Ta=25°C Vi=170V, Output short, Ta=80°C Derating Curve 250 Output Current Io(mA) 200 150 100 50 0 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 Ambient Temperature Ta(°C) Operation Range Derating Curve Conversion Efficiency 100 90 80 70 60 50 40 30 20 10 0 0 Conversion Efficiency η(%) Conversion Efficiency (Ta=31°C, Vi=141V) ∗1 Maximum output current varies depending on ambient temperature ; please refer to derating curve. ∗2 Please refer to Load regulation, Conversion efficiency. Application Circuit BP5039A Be sure to use fuse for safety. Pin No. 1 2 3 4 5 6 7 8 9 10 11 12 Function Output terminal Vo(24V) Not used Choke coil connect Not used Choke coil connect Not used COMMON Not used Not used N.C. Not used Input terminal Vi(141VDC) 4±1.0 50 100 150 Output Current Io(mA) 200 12 10 DC motor Ii Vi D1 R1 FUSE 7531 Load Regulation 30 Output Voltage Vo(V) 25 20 15 10 5 0 0 50 100 150 200 250 Output Current Io(mA) 300 Load Regulation (Ta=25°C, Vi=141V) Io C3 L1 + + ZNR − C1 − C2 Vo Please verify operation and characteristics in the customer's circuit before actual usage. Ensure that the load current does not exceed the maximum rating. External Component Specifications FUSE: FUSE C1: Input capacitor C2: Output capacitor Use a quick-acting fuse of (1A) above 250V, 22 to 820µF Ripple current 0.13Arms or above above 25V, 100 to 470µF low impedance ESR : 0.4Ω Max. Ripple current 0.25Arms or above Capacitor impedance affects the output ripple voltage. above 250V, 0.1 to 0.22µF Use a film or ceramic capacitor Evaluate under actual operating conditions. Inductance : 1.5mH Rating current : above 0.4A In the absolute maximum ratings, the reverse surge voltage should be 400V or above the average rectifier current should be 1A or greater, and the forward surge current should be 20A or more. 10 to 22Ω 1/4W Determine the ideal value through actual testing. A varistor must be used to protect against lightning surges and static electricity. Surface Temperature Increase 40 35 30 25 20 15 10 5 0 Temperature Rising ∆T(°C) Surface Temperature Increase (Ta=315°C, Vi=141V) C3: Noise reduction capacitor L1: Power Inductor D1: Rectifier diode 0 50 100 150 200 Output Current Io(mA) 250 R1: Noise reduction resistor ZNR: Varistor www.rohm.com ©2010 ROHM Co., Ltd. All rights reserved. 1/1 2010.01 - Rev.A Notice Notes No copying or reproduction of this document, in part or in whole, is permitted without the consent of ROHM Co.,Ltd. The content specified herein is subject to change for improvement without notice. The content specified herein is for the purpose of introducing ROHM's products (hereinafter "Products"). If you wish to use any such Product, please be sure to refer to the specifications, which can be obtained from ROHM upon request. Examples of application circuits, circuit constants and any other information contained herein illustrate the standard usage and operations of the Products. The peripheral conditions must be taken into account when designing circuits for mass production. Great care was taken in ensuring the accuracy of the information specified in this document. However, should you incur any damage arising from any inaccuracy or misprint of such information, ROHM shall bear no responsibility for such damage. The technical information specified herein is intended only to show the typical functions of and examples of application circuits for the Products. ROHM does not grant you, explicitly or implicitly, any license to use or exercise intellectual property or other rights held by ROHM and other parties. ROHM shall bear no responsibility whatsoever for any dispute arising from the use of such technical information. The Products specified in this document are intended to be used with general-use electronic equipment or devices (such as audio visual equipment, office-automation equipment, communication devices, electronic appliances and amusement devices). The Products specified in this document are not designed to be radiation tolerant. While ROHM always makes efforts to enhance the quality and reliability of its Products, a Product may fail or malfunction for a variety of reasons. Please be sure to implement in your equipment using the Products safety measures to guard against the possibility of physical injury, fire or any other damage caused in the event of the failure of any Product, such as derating, redundancy, fire control and fail-safe designs. ROHM shall bear no responsibility whatsoever for your use of any Product outside of the prescribed scope or not in accordance with the instruction manual. The Products are not designed or manufactured to be used with any equipment, device or system which requires an extremely high level of reliability the failure or malfunction of which may result in a direct threat to human life or create a risk of human injury (such as a medical instrument, transportation equipment, aerospace machinery, nuclear-reactor controller, fuelcontroller or other safety device). ROHM shall bear no responsibility in any way for use of any of the Products for the above special purposes. If a Product is intended to be used for any such special purpose, please contact a ROHM sales representative before purchasing. If you intend to export or ship overseas any Product or technology specified herein that may be controlled under the Foreign Exchange and the Foreign Trade Law, you will be required to obtain a license or permit under the Law. Thank you for your accessing to ROHM product informations. More detail product informations and catalogs are available, please contact us. ROHM Customer Support System http://www.rohm.com/contact/ www.rohm.com © 2010 ROHM Co., Ltd. All rights reserved. R1010A
BP5039A_10 价格&库存

很抱歉,暂时无法提供与“BP5039A_10”相匹配的价格&库存,您可以联系我们找货

免费人工找货