0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
BP5041B15_10

BP5041B15_10

  • 厂商:

    ROHM(罗姆)

  • 封装:

  • 描述:

    BP5041B15_10 - Non-Isolated AC/DC Converter - Rohm

  • 数据手册
  • 价格&库存
BP5041B15_10 数据手册
Data Sheet 220VAC Input/15VDC (80mA) Output Non-Isolated AC/DC Converter BP5041B15 Absolute Maximum Ratings Parameter Input voltage Output current ESD endurance Operating temperature range Storage temperature range Symbol Vi Io Vsurge Topr Tstg Limits 390 80 2 −25 to +80 −25 to +105 Unit V mApk kV °C °C 19.3MAX. Dimensions (Unit : mm) 32.5MAX. 11.5MAX. Mark Side 1 3 5 7 0.5 ± 0.1 1.3 ± 0.2 3.25MAX P=5.08 ± 0.2 22.86 6.75MAX. 10 0.25±0.05 4.75MAX. Electrical Characteristics Symbol Parameter Input voltage range Vi Output voltage Vo Output current Io Line regulation Vr Load regulation Vl Output ripple voltage Vp Power conversion efficiency η Min. 226 14.0 0 − − − 50 Typ. 282 15.0 − 0.05 0.05 0.05 64 Max. 390 16.0 80 0.15 0.15 0.15 − Unit V V mA V V Vp-p % Conditions DC(160 to 276VAC) Vi=282V, Io=50mA Vi=282V ∗1 Vi=226 to 390V, Io=50mA Vi=282V, Io=0 to 50mA ∗2 Vi=282V, Io=50mA Vi=282V, Io=80mA ∗2 Derating Curve 120 Output Current Io(mA) 100 80 60 40 20 0 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 Ambient Temperature Ta(°C) Operation Range Derating Curve ∗1 Maximum output current varies depending on ambient temperature ; please refer to derating curve. ∗2 Please refer to Load regulation, Conversion efficiency. Conversion Efficiency 100 90 80 70 60 50 40 30 20 10 0 0 Conversion Efficiency η(%) Conversion Efficiency (Ta=25°C, Vi=282V) Application Circuit BP5041B15 Please note that pin No.10 side is input. Pin No. 1 2 3 4 5 6 7 8 9 10 Function Output terminal Vo(15V) Not used N.C. Not used COMMON Not used N.C. Not used Not used Input terminal Vi(282VDC) 4±1.0 10 D1 Input AC200V 50Hz/60Hz ZNR + R1 10Ω1/4W FUSE 0.5A C2 0.1µF 7 5 3 1 10 20 30 40 50 60 70 80 Output Current Io(mA) Output +15V − C1 4.7µF/450V + C3 Load Regulation 16.0 15.8 15.6 15.4 15.2 15.0 14.8 14.6 14.4 14.2 14.0 Load Regulation (Ta=25°C, Vi=282V) Output Voltage Vo(V) − 100µF/50V Be sure to use fuse for safety. Please verify operation and characteristics in the customer's circuit before actual usage. Ensure that the load current does not exceed the maximum rating. External Component Specifications FUSE: FUSE C1: Input smoothing capacitor C2: Noise reduction capacitor Use a fuse of 0.5A Capacitance : 3.3 to 22µF Rated voltage : 450V or higher Ripple current 0.13Arms or greater Capacitance : 0.1 to 0.22µF Rated voltage : 450V or higher Use a film or ceramic capacitor. Evaluate under actual operating conditions. Capacitance : 100 to 470µF Rated voltage : 25V or higher, low impedance part Impedance is 0.39Ω max. at high frequencies Ripple current 0.1Arms above. Capacitor impedance affects the output ripple voltage. In the absolute maximum ratings, the reverse surge voltage should be 800V or higher, the average rectifying current should be 0.5A or higher, and the forward surge current should be 20A or higher. 10 to 22Ω 1/4W Determine the ideal value through actual testing. A varistor is required to protect against lightning surges and static electricity. 0 10 20 30 40 50 60 70 80 Output Current Io(mA) Surface Temperature Increase Temperature Rising ∆T(°C) 25 20 15 10 5 0 0 Surface Temperature Increase (Ta=25°C,Vi=282V) C3: Output smoothing capacitor 10 20 30 40 50 60 70 80 Output Current Io(mA) D1: Rectifier diode R1: Noise reduction resistor ZNR: Varistor www.rohm.com ©2010 ROHM Co., Ltd. All rights reserved. 1/1 2010.01 - Rev.A Notice Notes No copying or reproduction of this document, in part or in whole, is permitted without the consent of ROHM Co.,Ltd. The content specified herein is subject to change for improvement without notice. The content specified herein is for the purpose of introducing ROHM's products (hereinafter "Products"). If you wish to use any such Product, please be sure to refer to the specifications, which can be obtained from ROHM upon request. Examples of application circuits, circuit constants and any other information contained herein illustrate the standard usage and operations of the Products. The peripheral conditions must be taken into account when designing circuits for mass production. Great care was taken in ensuring the accuracy of the information specified in this document. However, should you incur any damage arising from any inaccuracy or misprint of such information, ROHM shall bear no responsibility for such damage. The technical information specified herein is intended only to show the typical functions of and examples of application circuits for the Products. ROHM does not grant you, explicitly or implicitly, any license to use or exercise intellectual property or other rights held by ROHM and other parties. ROHM shall bear no responsibility whatsoever for any dispute arising from the use of such technical information. The Products specified in this document are intended to be used with general-use electronic equipment or devices (such as audio visual equipment, office-automation equipment, communication devices, electronic appliances and amusement devices). The Products specified in this document are not designed to be radiation tolerant. While ROHM always makes efforts to enhance the quality and reliability of its Products, a Product may fail or malfunction for a variety of reasons. Please be sure to implement in your equipment using the Products safety measures to guard against the possibility of physical injury, fire or any other damage caused in the event of the failure of any Product, such as derating, redundancy, fire control and fail-safe designs. ROHM shall bear no responsibility whatsoever for your use of any Product outside of the prescribed scope or not in accordance with the instruction manual. The Products are not designed or manufactured to be used with any equipment, device or system which requires an extremely high level of reliability the failure or malfunction of which may result in a direct threat to human life or create a risk of human injury (such as a medical instrument, transportation equipment, aerospace machinery, nuclear-reactor controller, fuelcontroller or other safety device). ROHM shall bear no responsibility in any way for use of any of the Products for the above special purposes. If a Product is intended to be used for any such special purpose, please contact a ROHM sales representative before purchasing. If you intend to export or ship overseas any Product or technology specified herein that may be controlled under the Foreign Exchange and the Foreign Trade Law, you will be required to obtain a license or permit under the Law. Thank you for your accessing to ROHM product informations. More detail product informations and catalogs are available, please contact us. ROHM Customer Support System http://www.rohm.com/contact/ www.rohm.com © 2010 ROHM Co., Ltd. All rights reserved. R1010A
BP5041B15_10 价格&库存

很抱歉,暂时无法提供与“BP5041B15_10”相匹配的价格&库存,您可以联系我们找货

免费人工找货