0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
EKI07117

EKI07117

  • 厂商:

    SANKEN(三垦)

  • 封装:

    SOT78

  • 描述:

    MOSFET N-CH 75V 62A TO-220

  • 数据手册
  • 价格&库存
EKI07117 数据手册
75 V, 62 A, 7.2 mΩ Low RDS(ON) N ch Trench Power MOSFET EKI07117 Data Sheet Package ● ● ● ● V(BR)DSS --------------------------------- 75 V (ID = 100 µA) ID ---------------------------------------------------------- 62 A RDS(ON) ---------- 9.7 mΩ max. (VGS = 10 V, ID = 31.2 A) Qg ------25.0 nC (VGS = 4.5 V, VDS = 38 V, ID = 31.2 A) ● TO220-3L ● ● ● ● ● ● Low Total Gate Charge High Speed Switching Low On-Resistance Capable of 4.5 V Gate Drive 100 % UIL Tested RoHS Compliant (4) ns Features es ig (1) (2) (3) Applications D(2)(4) ew D ● DC-DC converters ● Synchronous Rectification ● Power Supplies Not to scale S(3) d fo rN G(1)  Unless otherwise specified, TA = 25 °C Symbol Test conditions Unit VDS 75 V VGS ± 20 V TC = 25 °C 62 A PW ≤ 100µs Duty cycle ≤ 1 % 125 A 62 A 125 A 126 mJ 23.3 A 116 W m Drain to Source Voltage ec o m Gate to Source Voltage Continuous Drain Current Rating en Parameter de Absolute Maximum Ratings IDM ISM Single Pulse Avalanche Energy EAS Avalanche Current IAS Power Dissipation PD Operating Junction Temperature TJ 150 °C TSTG − 55 to 150 °C ot R Continuous Source Current (Body Diode) Pulsed Source Current (Body Diode) N Pulsed Drain Current ID Storage Temperature Range IS PW ≤ 100µs Duty cycle ≤ 1 % VDD = 38 V, L = 1 mH, IAS = 11.2 A, unclamped, RG = 4.7 Ω Refer to Figure 1 TC = 25 °C EKI07117-DSE Rev.1.4 SANKEN ELCTRIC CO., LTD. May 09, 2018 http://www.sanken-ele.co.jp/en © SANKEN ELECTRIC CO., LTD. 2013 1 EKI07117 Thermal Characteristics  Unless otherwise specified, TA = 25 °C Parameter Thermal Resistance (Junction to Case) Thermal Resistance (Junction to Ambient) Symbol Test Conditions Min. Typ. Max. Unit RθJC − − 1.1 °C/W RθJA − − 62.5 °C/W Min. Typ. Electrical Characteristics ns  Unless otherwise specified, TA = 25 °C Unit − − V − 100 µA − − ± 100 nA 1.0 2.0 2.5 V − 7.2 9.7 mΩ ID = 15.6 A, VGS = 4.5 V − 8.2 11.2 mΩ f = 1 MHz − 1.1 − Ω − 4040 − − 370 − − 215 − − 54.0 − − 25.0 − − 9.8 − − 7.3 − − 6.8 − − 6.4 − − 29.4 − − 13.3 − IS = 31.2 A, VGS = 0 V − 0.9 1.5 V IF = 31.2 A di/dt = 100 A/µs Refer to Figure 3 − 44.3 − ns − 69.1 − nC V(BR)DSS ID = 100 μA, VGS = 0 V 75 IDSS VDS = 75 V, VGS = 0 V − Gate to Source Leakage Current IGSS VGS = ± 20 V RG Input Capacitance Ciss Output Capacitance Coss Reverse Transfer Capacitance Crss Total Gate Charge (VGS = 10 V) Qg1 m Qgs ec o Turn-On Delay Time Qg2 m Gate to Drain Charge Rise Time R Turn-Off Delay Time N ot Fall Time Source to Drain Diode Forward Voltage Source to Drain Diode Reverse Recovery Time Source to Drain Diode Reverse Recovery Charge VDS = 25 V VGS = 0 V f = 1 MHz en Total Gate Charge (VGS = 4.5 V) Gate to Source Charge ID = 31.2 A, VGS = 10 V de Gate Resistance ew RDS(ON) rN Static Drain to Source On-Resistance VDS = VGS, ID = 1 mA fo VGS(th) d Gate Threshold Voltage Test Conditions VDS = 38 V ID = 31.2 A Qgd td(on) tr td(off) VDD = 38 V ID = 31.2 A VGS = 10 V, RG = 4.7 Ω Refer to Figure 2 tf VSD trr Qrr EKI07117-DSE Rev.1.4 SANKEN ELCTRIC CO., LTD. May 09, 2018 http://www.sanken-ele.co.jp/en © SANKEN ELECTRIC CO., LTD. 2013 Max. es ig Symbol D Parameter Drain to Source Breakdown Voltage Drain to Source Leakage Current pF nC ns 2 EKI07117 Test Circuits and Performance Curves E AS  L V(BR)DSS 1 2  L  I AS  2 V(BR)DSS  VDD V(BR)DSS ID VDS IAS RG VDD VDS 0V ID VDD ns VGS (b) Waveform Unclamped Inductive Switching RL RG VDD d VGS 90% VDS de 10% td(on) tr m en P.W. = 10 μs Duty cycle ≤ 1 % td(off) tf ton toff (a) Test Circuit (b) Waveform Figure 2. Switching Time ec o m 10% fo VDS 0V 90% rN VGS ew D Figure 1. es ig (a) Test Circuit R D.U.T. ot IF L IF N VDD RG trr 0V VGS IRM × 90 % di/dt 0V IRM (a) Test Circuit Figure 3. (b) Waveform Diode Reverse Recovery Time EKI07117-DSE Rev.1.4 SANKEN ELCTRIC CO., LTD. May 09, 2018 http://www.sanken-ele.co.jp/en © SANKEN ELECTRIC CO., LTD. 2013 3 EKI07117 RDS(ON)-ID characteristics (typical) RDS(ON)-ID characteristics (typical) VGS=10V ID-VGS characteristics (typical) VGS=4.5V 20 VDS=5V 25 140 120 20 15 75℃ 10 25℃ 100 Tc = 125℃ 15 ID (A) RDS(ON) (mΩ ) RDS(ON) (mΩ ) Tc = 125℃ 75℃ 10 25℃ 5 80 60 Tc =125℃ 40 75℃ 20 25℃ 0 0 20 40 60 80 100 120 0 20 40 60 ID (A) 80 100 0 120 0 100 100 60 3V 40 5 10 0 15 0 75℃ 40 0.5 25℃ 20 0 1 0 1.5 en m 3 VGS (V) Vth (V) 10 ec o Coss 5 R 10 10 20 1 ID=1mA VGS=VDS 0 30 40 50 0 0 ot 0 2 Tc=25℃ VDS=38V ID=31.2A Crss Ta=25℃ VGS=0V f =1MHz 20 40 25 60 50 Qg (nC) N 16 94 14 14 92 12 12 6 BVDSS (V) 96 16 8 10 8 6 ID=31.2A VGS=10V 2 ID=15.6A VGS=4.5V 50 75 100 Tc (℃) 125 150 86 ID=1mA VGS=0V 80 0 25 25 50 75 150 88 82 2 0 125 90 84 4 4 100 BVDSS-Tc characteristics (typical) 18 RDS(ON) (mΩ) RDS(ON) (mΩ) RDS(ON)-Tc characteristics (typical) 18 10 75 Tc (℃) VDS (V) RDS(ON)-Tc characteristics (typical) 1.5 Vth-Tc characteristics (typical) m Ciss 100 1 d VGS - Qg characteristics (typical) 15 100000 1000 0.5 VSD (V) de Capacitance-VDS characteristics (typical) 10000 Tc =125℃ 60 VSD (V) VGS (V) Capacitance (pF) fo 0 80 0V 20 0.0 IDR (A) ew VGS=4.5V rN IDR (A) VDS (V) 80 ID=15.6A 0.1 VDS=0V D VGS=10V 0.4 ID=31.2A ID=27.2A 5 120 120 0.3 4 140 140 0.5 3 IDR-VSD characteristics (typical) Tc=25℃ Tc=25℃ 0.6 2 VGS (V) IDR-VSD characteristics (typical) VDS-VGS characteristics (typical) 0.2 1 ID (A) es ig 0 ns 5 100 125 150 Tc (℃) EKI07117-DSE Rev.1.4 SANKEN ELCTRIC CO., LTD. May 09, 2018 http://www.sanken-ele.co.jp/en © SANKEN ELECTRIC CO., LTD. 2013 78 25 50 75 100 125 150 Tc (℃) 4 EKI07117 PD-Ta Derating SAFE OPERATING AREA 120 1000 ID(pulse) MAX PT=100μs 100 ID (A) PD (W) 90 60 10 PT=1ms 1 30 0.1 0 50 100 0.1 150 1 10 VDS (V) Ta (℃) TRANSIENT THERMAL RESISTANCE - PULSE WIDTH D ew 1.E+00 rN Rth j-c (℃/W) 1.E+01 100 es ig 0 ns 1 shot Tc=25℃ 1.E-03 1.E-02 1.E-01 de 1.E-02 1.E-04 d fo 1.E-01 1.E+00 Tc = 25℃ 1shot VDS < 10V 1.E+01 1.E+02 N ot R ec o m m en P.T. (sec) EKI07117-DSE Rev.1.4 SANKEN ELCTRIC CO., LTD. May 09, 2018 http://www.sanken-ele.co.jp/en © SANKEN ELECTRIC CO., LTD. 2013 5 EKI07117 Physical Dimensions en de d fo rN ew D es ig ns  TO220-3L NOTES: Dimensions in millimeters Maximum gate burr height is 0.3 mm. Bare lead frame: Pb-free (RoHS compliant) When soldering the products, it is required to minimize the working time, within the following limits: Flow: 260 ± 5 °C / 10 ± 1 s, 2 times Soldering Iron: 380 ± 10 °C / 3.5 ± 0.5 s, 1 time Soldering should be at a distance of at least 1.5 mm from the body of the product. - Recommended screw torque for TO220: 0.490 N∙m to 0.686 N∙m (5 kgf∙cm to 7 kgf∙cm) R ec o m m - N ot Marking Diagram YMW BXX EKI××××× Lot Number: Y is the last digit of the year of manufacture (0 to 9) M is the month of the year (1 to 9, O, N, or D) W is the week of the month (1 to 5) B expresses Pb free pins XX is the control number Part Number EKI07117-DSE Rev.1.4 SANKEN ELCTRIC CO., LTD. May 09, 2018 http://www.sanken-ele.co.jp/en © SANKEN ELECTRIC CO., LTD. 2013 6 EKI07117 Important Notes N ot R ec o m m en de d fo rN ew D es ig ns ● All data, illustrations, graphs, tables and any other information included in this document (the “Information”) as to Sanken’s products listed herein (the “Sanken Products”) are current as of the date this document is issued. The Information is subject to any change without notice due to improvement of the Sanken Products, etc. Please make sure to confirm with a Sanken sales representative that the contents set forth in this document reflect the latest revisions before use. ● The Sanken Products are intended for use as components of general purpose electronic equipment or apparatus (such as home appliances, office equipment, telecommunication equipment, measuring equipment, etc.). Prior to use of the Sanken Products, please put your signature, or affix your name and seal, on the specification documents of the Sanken Products and return them to Sanken. When considering use of the Sanken Products for any applications that require higher reliability (such as transportation equipment and its control systems, traffic signal control systems or equipment, disaster/crime alarm systems, various safety devices, etc.), you must contact a Sanken sales representative to discuss the suitability of such use and put your signature, or affix your name and seal, on the specification documents of the Sanken Products and return them to Sanken, prior to the use of the Sanken Products. The Sanken Products are not intended for use in any applications that require extremely high reliability such as: aerospace equipment; nuclear power control systems; and medical equipment or systems, whose failure or malfunction may result in death or serious injury to people, i.e., medical devices in Class III or a higher class as defined by relevant laws of Japan (collectively, the “Specific Applications”). Sanken assumes no liability or responsibility whatsoever for any and all damages and losses that may be suffered by you, users or any third party, resulting from the use of the Sanken Products in the Specific Applications or in manner not in compliance with the instructions set forth herein. ● In the event of using the Sanken Products by either (i) combining other products or materials or both therewith or (ii) physically, chemically or otherwise processing or treating or both the same, you must duly consider all possible risks that may result from all such uses in advance and proceed therewith at your own responsibility. ● Although Sanken is making efforts to enhance the quality and reliability of its products, it is impossible to completely avoid the occurrence of any failure or defect or both in semiconductor products at a certain rate. You must take, at your own responsibility, preventative measures including using a sufficient safety design and confirming safety of any equipment or systems in/for which the Sanken Products are used, upon due consideration of a failure occurrence rate and derating, etc., in order not to cause any human injury or death, fire accident or social harm which may result from any failure or malfunction of the Sanken Products. Please refer to the relevant specification documents and Sanken’s official website in relation to derating. ● No anti-radioactive ray design has been adopted for the Sanken Products. ● The circuit constant, operation examples, circuit examples, pattern layout examples, design examples, recommended examples, all information and evaluation results based thereon, etc., described in this document are presented for the sole purpose of reference of use of the Sanken Products. ● Sanken assumes no responsibility whatsoever for any and all damages and losses that may be suffered by you, users or any third party, or any possible infringement of any and all property rights including intellectual property rights and any other rights of you, users or any third party, resulting from the Information. ● No information in this document can be transcribed or copied or both without Sanken’s prior written consent. ● Regarding the Information, no license, express, implied or otherwise, is granted hereby under any intellectual property rights and any other rights of Sanken. ● Unless otherwise agreed in writing between Sanken and you, Sanken makes no warranty of any kind, whether express or implied, including, without limitation, any warranty (i) as to the quality or performance of the Sanken Products (such as implied warranty of merchantability, and implied warranty of fitness for a particular purpose or special environment), (ii) that any Sanken Product is delivered free of claims of third parties by way of infringement or the like, (iii) that may arise from course of performance, course of dealing or usage of trade, and (iv) as to the Information (including its accuracy, usefulness, and reliability). ● In the event of using the Sanken Products, you must use the same after carefully examining all applicable environmental laws and regulations that regulate the inclusion or use or both of any particular controlled substances, including, but not limited to, the EU RoHS Directive, so as to be in strict compliance with such applicable laws and regulations. ● You must not use the Sanken Products or the Information for the purpose of any military applications or use, including but not limited to the development of weapons of mass destruction. In the event of exporting the Sanken Products or the Information, or providing them for non-residents, you must comply with all applicable export control laws and regulations in each country including the U.S. Export Administration Regulations (EAR) and the Foreign Exchange and Foreign Trade Act of Japan, and follow the procedures required by such applicable laws and regulations. ● Sanken assumes no responsibility for any troubles, which may occur during the transportation of the Sanken Products including the falling thereof, out of Sanken’s distribution network. ● Although Sanken has prepared this document with its due care to pursue the accuracy thereof, Sanken does not warrant that it is error free and Sanken assumes no liability whatsoever for any and all damages and losses which may be suffered by you resulting from any possible errors or omissions in connection with the Information. ● Please refer to our official website in relation to general instructions and directions for using the Sanken Products, and refer to the relevant specification documents in relation to particular precautions when using the Sanken Products. ● All rights and title in and to any specific trademark or tradename belong to Sanken and such original right holder(s). DSGN-CEZ-16003 EKI07117-DSE Rev.1.4 SANKEN ELCTRIC CO., LTD. May 09, 2018 http://www.sanken-ele.co.jp/en © SANKEN ELECTRIC CO., LTD. 2013 7
EKI07117 价格&库存

很抱歉,暂时无法提供与“EKI07117”相匹配的价格&库存,您可以联系我们找货

免费人工找货