Power Entry Modules with Line Filter www.schurter.com/pg06 IEC Appliance Inlet C14 with Filter, Circuit Breaker TA45
545
Standard- or Medical-Filter
C14
70° C
Description
- Panel Mount: Screw-on mounting from front side - 3 Functions: Appliance Inlet Protection class I, circuit breaker type TA45 2pole, Line filter in standard and medical version - Quick connect terminals 6.3 x 0.8 mm - Alternative: version without line filter 6145 - We recommend for new applications the new type DF12
Characteristics
- All single elements are already wired Unwired versions available on request - Line switch non-illuminated or illuminated Thermal overload protection Optional with undervoltage- or remote trip release - Qualified for use in equipment according IEC/EN 60950
References Weblinks
General Product Information Approvals, RoHS, CHINA-RoHS, Mating Connectors, e-Store, Distributor-Stock-Check, Accessories
Approvals
- VDE License Number: 117118 - UL License Number: E72928
Technical Data
Ratings IEC Ratings UL/CSA Leakage Current Dielectric Strength 1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz 1 - 15 A @ Ta 40 °C / 125 VAC; 60 Hz standard < 0.5 mA (250 V / 60 Hz) medical < 5 µA (250 V / 60 Hz) > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) -10 °C to 55 °C 10/055/21 acc. to IEC 60068-1 from front side IP 40 acc. to IEC 60529 Suitable for appliances with protection class 1 acc. to IEC 61140 Quick connect terminals 6.3 x 0.8 mm Screw: max 8 mm Mounting screw torque max 0.5 Nm Thermoplastic, black, UL 94V-0 Appliance-Inlet/-Outlet C14 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 °C, 10 A, Protection Class 1 Acc. IEC/EN 60934, UL 1077, CSA 22.2 no. 235 2-pole rocker switch, illuminated or nonilluminated. Optional with undervoltage- or remote trip release Short circuit capacity Icn: at In < 3A/240VAC : 10 x In at In ≥ 3A/240VAC : 300A Rocker switch 2-pole non-illuminated or illuminated acc. to IEC 61058-1 Technical details Standard and Medical Version, IEC 60939, IEC 60601-1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details > 100'000 h acc. to MIL-HB-217 F
Circuit Breakers
Allowable Operation Temp. Climatic Category Degree of Protection Protection Class Terminal Panel Thickness s Material: Housing
Line Switch
Line Filter
MTBF
EMC Products
545
www.schurter.com/pg06 Dimensions
Detail A 2 36 43 A 3.25 ø6 1
Power Entry Modules with Line Filter
67.5 mm
29 +0.2
0
6.3x0.8mm
R 3-0.5
0
91.5
80
6.3x0.8mm 50.7 67.5* 13.5 M3/ø 3.6
* --- Version TA45 with undervoltage release
Technical Data of Filter-Components
Rated Current [A] 1 2 3 4 6 8 10 15 1 2 6 8 10 15 Filter-Type Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Inductances L [mH] 2 x 11 2x4 2 x 2.5 2 x 1.6 2 x 0.7 2 x 0.6 2 x 0.4 2 x 0.1 2 x 11 2x4 2 x 0.7 2 x 0.6 2 x 0.4 2 x 0.1 Capacitance CX [nF] 47 47 47 47 47 47 47 47 47 47 47 47 47 47 Capacitance CY [nF] 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 R [MΩ] 1 1 1 1 1 1
Diagrams Standard version
Medical version
1) Line 2) Load
1) Line 2) Load
EMC Products
80 ±0.1
72
+0.1 0
Power Entry Modules with Line Filter www.schurter.com/pg06
545
- - - - differential mode _____ common mode
Attenuation Loss 1A
Standard version
2A
3A
4A
6A
8A
10 A
15A
Medical version (M5)
1A
2A
3A
4A
6A
8A
10 A
15A
EMC Products
545
www.schurter.com/pg06
Power Entry Modules with Line Filter
4
EMC Products
Power Entry Modules with Line Filter www.schurter.com/pg06 Packaging unit Accessories
Description
545
20 Pcs
Assorted Covers Rear Cover 0859.0074
Mating Outlets/Connectors
Category / Description
Appliance Outlet Overview complete IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder or Quick-connect Terminal IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder or Quick-connect Terminal Appliance Outlet further types to 5145 Connector Overview complete IEC Connector C15, Rewireable, Straight IEC Connector C15A, Rewireable, Straight IEC Connector C15A, Rewireable, Straight IEC Connector C15A, Rewireable, Angled IEC Connector C13, Rewireable, Angled Connector further types to 5145 Power Cord Overview complete Power Cord with IEC Connector C13, Angled Power Cord with IEC Connector C13, Angled Power Cord with IEC Connector C13, Angled Power Cord with IEC Connector C13, Angled Power Cord with IEC Connector C13 Power Cord further types to 5145 0311 3011 3012 3013 3020 ... 0101 0102 0102-G 0112 4012 ... 4787 4788 5091 5092
EMC Products
5
545
www.schurter.com/pg06
Power Entry Modules with Line Filter
Technical data (continued) Circuit breaker Tripping characteristics In < 3 A
[ min ] [ sec ] 10’000
Type Rated current TA45 In < 3 A 1-pole protected
Tripping characteristics In 3… 15 A
[ min ] [ sec ] 10’000
Type Rated current TA45 I n ≥ 3... ≤ 15 A 1-pole protected
60 30 20 10 5 200 100 1 50 20 10 5 2 1 0,5
Tripping time
60 30 20 10 5 200 100 1 50 20 10 5 2 1 0,5
Tripping time
2000 1000 500
Ambient temp.
2-pole protected +23 °C
2’000 1’000 500
Ambient temp.
2-pole protected +23 °C
0,3 0,2 0,1 1,05 1,32 2 3 4 [ x In ] 5 8 10
Multiple of rated current
0,3 0,2 0,1 1,05 1,32 2 3 4 [ x In ] 5 8 10
Multiple of rated current
Effect of ambient temperature 1) The unit is calibrated for an ambient temperature of +23 °C. To determine the rated current for a lower or higher ambient temperature, use a correction factor from the table below. * Ambient temperature [°C] Correction factor –10 0,89 –5 0,91 0 0,92 +23 1,00 +30 1,03 +40 1,08 +55 1,16
* Temperature must be measured at the rear of the breaker next to the terminals after equipment operating temperature has been reached.
1) Example Rated current at +23 °C Ambient temperature Correction factor Chosen rated current at + 40 °C ambient temperature
6,0 A +40 °C 1,08 6 A x 1,08 = 6,5 A
Order code (Order example) Type Order code TA45 (2-pole rocker-switch without accessories) Wiring 0 W ithout 1 W ith Type of line filter 1 Standard 3 Medical Rated current of line filter 1 1 (A) 5 6 (A) 2 2 (A) 6 8 (A) 3 3 (A) 7 10 (A) 4 4 (A) 8 15 (A)
5145. A B T W F 1 5 0 C 0 see table 1
.001
Please note that Schurter will establish an internal part number for logistical use in additional to the order code. The format of this internal part number is, for example 5145.0031.001
6
The specifications, descriptions and illustrations indicated in this document are based on EMC Products current information. All content is subject to modifications and amendments.