0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
40PC006B3A

40PC006B3A

  • 厂商:

    SENSORTECHNICS

  • 封装:

  • 描述:

    40PC006B3A - Fully signal conditioned pressure transducer - Sensortechnics GmbH

  • 数据手册
  • 价格&库存
40PC006B3A 数据手册
40PC Series Fully signal conditioned pressure transducer FEATURES · Pressure ranges from 0 ... ± 50 mmHg to 0 ... 500 psi gage · High accuracy · TTL power supply · Ratiometric 0.5 to 4.5 V output · Dual-Inline pinning for easy PCB-mounting · Excellent media compatibility MEDIA COMPATIBILITY P1: dry gases only P2: all media compatible with glass, silicon, stainless steel, Invar, Sn/Ni plating or Sn/Ag solder SPECIFICATIONS Maximum ratings Supply voltage (VS) Output current Source Sink Output load capacitance Temperature limits Operating Storage Compensated Humidity (non-condensing) 4.75 ... 5.25 V ELECTRICAL CONNECTION 0.5 mA 1.0 mA 10 nF NOTES: -45 to +125°C -55 to +125°C -45 to +125°C 0 - 95 %RH 1. Square corner marks pin 1 (Vs) 2. Output is short circuit protected November 2007 / 573 1/8 www.sensortechnics.com 40PC Series Fully signal conditioned pressure transducer PRESSURE RANGE SPECIFICATIONS (unless otherwise noted, VS = 5.00 V, RL > 100 kΩ, tamb = 25°C) Part number 40P C 001B 2A 40PC006G2A 40PC015G2A 40P C 015V 2A 40PC030G2A 40PC100G2A 40PC150G2A 40PC250G2A 40PC500G2A Operating pressure range 0 ... ±50 mmHg 0 ... 300 mmHg 0 ... 15 psig 0 ... -15 psig 0 ... 30 psig 0 ... 100 psig 0 ... 150 psig 0 ... 250 psig 0 ... 500 psig Proof pressure1 170 mmHg 650 mmHg 4 5 p si 3 0 p si 6 0 p si 2 0 0 p si 3 0 0 p si 5 0 0 p si 1 0 0 0 p si Sensitivity (typ.) 40.0 mV/mmHg 13.33 mV/mmHg 266.7 mV/psi -266.7 mV/psi 133.3 mV/psi 40.0 mV/psi 25.7 mV/psi 16.0 mV/psi 8.0 mV/psi Specification notes: 1. 2. 3. 4. 5. 6. Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element. Non-linearity - the maximum deviation of measured output at constant temperature, from "Best Straight Line" through three points (offset pressure, full scale pressure and 1/2 full scale pressure). Thermal effects tested and guaranteed in the specified temperature ranges relative to 25°C. All specifications shown are relative to 25°C. Span is the algebraic difference between lowest and highest specified pressure. Total accuracy is the maximum deviation from the 25°C reference transfer function at any pressure or temperature over the specified ranges. This calculation includes null, span, linearity, hysteresis, repeatability, null shift and span shift. Response time for 0 to full-scale pressure step change, readings taken at 10 % and 90 % of full-scale pressure. 2/8 November 2007 / 573 www.sensortechnics.com 40PC Series Fully signal conditioned pressure transducer 40PC001B2A PERFORMANCE CHARACTERISTICS Characteristics Min. -50 2.45 at -50 mmHg at +50 mmHg Offset Span 2.50 4.0 0.5 4.5 ±1.50 ±1.50 ±0.8 ±0.15 ±0.25 10.0 1 mA ms %FSS (unless otherwise noted, VS = 5.00 V, RL > 100 kΩ, tamb = 25°C) Typ. Max. +50 2.55 V Unit mmHg Operating pressure Zero pressure offset Span 4 Output Thermal effects (0 to 50°C)3 Non-linearity (BSL) 2 Hysteresis and repeatability Ratiometricity error (VS = 4.75 ... 5.25 V) Current consumption (no load) Response time 6 40PC006G2A PERFORMANCE CHARACTERISTICS Characteristics Min. 0 0.45 3.95 Offset Span -18 to +63°C -45 to +125°C -18 to +63°C -45 to +125°C Combined offset and span -18 to +63°C -45 to +125°C 0.50 4.00 4.5 ±1.25 ±2.75 ±0.75 ±2.0 ±1.5 ±4.0 ±4.0 ±0.2 ±0.15 ±0.25 10.0 1 mA ms %FSS (unless otherwise noted, VS = 5.00 V, RL > 100 kΩ, tamb = 25°C) Typ. Max. 300 0.55 4.05 V Unit mmHg Operating pressure Zero pressure offset Span 4 Full scale output Thermal effects3 Total accuracy5 Non-linearity (BSL)2 Hysteresis and repeatability Ratiometricity error (VS = 4.75 ... 5.25 V) Current consumption (no load) Response time6 -45 to +125°C November 2007 / 573 3/8 www.sensortechnics.com 40PC Series Fully signal conditioned pressure transducer 40PC015G2A PERFORMANCE CHARACTERISTICS Characteristics Min. 0 0.39 3.89 Offset Span Combined offset and span -18 -45 -18 -45 -18 -45 -45 to to to to to to to +63°C +85°C +63°C +85°C +63°C +85°C +85°C ±0.15 ±0.25 10.0 1 mA ms (unless otherwise noted, VS = 5.00 V, RL > 100 kΩ, tamb = 25°C) Typ. 0.50 4.00 4.5 Max. 15 0.61 4.11 ±2.0 ±2.75 ±0.75 ±1.0 ±2.0 ±3.0 ±4.0 ±0.2 Unit p si g V Operating pressure Zero pressure offset Span4 Full scale output Thermal effects3 %FSS Total accuracy5 Non-linearity (BSL)2 Hysteresis and repeatability Ratiometricity error (VS = 4.75 ... 5.25 V) Current consumption (no load) Response time6 40PC015V2A PERFORMANCE CHARACTERISTICS Characteristics Min. 0 0.46 3.9 Offset Span -18 to +25°C -45 to +85°C -18 to +25°C +25 to +85°C -45 to +25°C -18 to +25°C +25 to +85°C -40 to +25°C +45 to +85°C ±0.15 ±0.25 10.0 1 mA ms (unless otherwise noted, VS = 5.00 V, RL > 100 kΩ, tamb = 25°C) Typ. 0.50 4.0 4.5 Max. -15 0.54 4.1 ±0.75 ±1.0 ±2.0 ±1.25 ±2.25 ±1.5 ±1.0 ±1.75 ±2.25 ±0.3 Unit p si g V Operating pressure Zero pressure offset Span4 Full scale output Thermal effects3 Combined offset and span %FSS Total accuracy5 Non-linearity (BSL)2 Hysteresis and repeatability Ratiometricity error (VS = 4.75 ... 5.25 V) Current consumption (no load) Response time6 4/8 November 2007 / 573 www.sensortechnics.com 40PC Series Fully signal conditioned pressure transducer 40PC030G2A PERFORMANCE CHARACTERISTICS Characteristics Min. 0 0.46 3.92 Offset -18 -45 -45 -18 -45 -45 -18 -45 -45 to to to to to to to to to +63°C +85°C +125°C +63°C +85°C +125°C +63°C +125°C +125°C ±0.15 ±0.25 10.0 1 mA ms (unless otherwise noted, VS = 5.00 V, RL > 100 kΩ, tamb = 25°C) Typ. 0.50 4.00 4.5 Max. 30 0.54 4.08 ±1.5 ±2.0 ±2.25 ±1.5 ±2.0 ±2.25 ±2.0 ±2.25 ±2.25 ±0.3 Unit p si g V Operating pressure Zero pressure offset Span4 Full scale output Thermal effects3 Span Combined offset and span Total accuracy5 Non-linearity (BSL)2 Hysteresis and repeatability Ratiometricity error (VS = 4.75 ... 5.25 V) Current consumption (no load) Response time6 %FSS 40PC100G2A PERFORMANCE CHARACTERISTICS Characteristics Min. 0 0.46 3.91 Offset -18 -45 -45 -18 -45 -45 -18 -45 -45 -45 to to to to to to to to to to +63°C +85°C +125°C +63°C +85°C +125°C +63°C +85°C +125°C +125°C ±0.15 ±0.25 10.0 1 mA ms (unless otherwise noted, VS = 5.00 V, RL > 100 kΩ, tamb = 25°C) Typ. 0.50 4.0 4.5 Max. 100 0.54 4.09 ±1.25 ±2.0 ±3.0 ±0.75 ±1.0 ±2.0 ±1.5 ±2.5 ±3.0 ±3.0 ±0.1 Unit p si g V Operating pressure Zero pressure offset Span4 Full scale output Thermal effects3 Span Combined offset and span %FSS Total accuracy5 Non-linearity (BSL)2 Hysteresis and repeatability Ratiometricity error (VS = 4.75 ... 5.25 V) Current consumption (no load) Response time6 November 2007 / 573 5/8 www.sensortechnics.com 40PC Series Fully signal conditioned pressure transducer 40PC150G2A PERFORMANCE CHARACTERISTICS Characteristics Min. 0 0.46 3.93 Offset -18 -45 -45 -18 -45 -45 -18 -45 -45 -45 to to to to to to to to to to +63°C +85°C +125°C +63°C +85°C +125°C +63°C +85°C +125°C +125°C ±0.15 ±0.25 10.0 1 mA ms (unless otherwise noted, VS = 5.00 V, RL > 100 kΩ, tamb = 25°C) Typ. 0.50 4.0 4.5 Max. 150 0.54 4.07 ±0.75 ±1.0 ±1.5 ±0.75 ±1.0 ±1.5 ±0.75 ±1.0 ±1.5 ±2.5 ±0.1 Unit p si g V Operating pressure Zero pressure offset Span4 Full scale output Thermal effects3 Span Combined offset and span %FSS Total accuracy5 Non-linearity (BSL)2 Hysteresis and repeatability Ratiometricity error (VS = 4.75 ... 5.25 V) Current consumption (no load) Response time6 40PC250G2A PERFORMANCE CHARACTERISTICS Characteristics Min. 0 0.46 3.93 Offset -18 -45 -45 -18 -45 -45 -18 -45 -45 -45 to to to to to to to to to to +63°C +85°C +125°C +63°C +85°C +125°C +63°C +85°C +125°C +125°C ±0.15 ±0.25 10.0 1 mA ms (unless otherwise noted, VS = 5.00 V, RL > 100 kΩ, tamb = 25°C) Typ. 0.50 4.0 4.5 Max. 250 0.54 4.07 ±0.75 ±1.0 ±2.0 ±0.75 ±1.0 ±2.0 ±0.75 ±1.0 ±3.0 ±3.0 ±0.1 Unit p si g V Operating pressure Zero pressure offset Span4 Full scale output Thermal effects3 Span Combined offset and span %FSS Total accuracy5 Non-linearity (BSL)2 Hysteresis and repeatability Ratiometricity error (VS = 4.75 ... 5.25 V) Current consumption (no load) Response time6 6/8 November 2007 / 573 www.sensortechnics.com 40PC Series Fully signal conditioned pressure transducer 40PC500G2A PERFORMANCE CHARACTERISTICS Characteristics Min. 0 0.46 3.91 Offset -18 -45 -45 -18 -45 -45 -18 -45 -45 -45 to to to to to to to to to to +63°C +85°C +125°C +63°C +85°C +125°C +63°C +85°C +125°C +125°C ±0.15 ±0.25 10.0 1 mA ms (unless otherwise noted, VS = 5.00 V, RL > 100 kΩ, tamb = 25°C) Typ. 0.50 4.0 4.5 Max. 500 0.54 4.09 ±1.0 ±1.5 ±2.5 ±0.75 ±1.0 ±1.5 ±1.0 ±1.75 ±3.0 ±3.0 ±0.2 Unit p si g V Operating pressure Zero pressure offset Span4 Full scale output Thermal effects3 Span Combined offset and span %FSS Total accuracy5 Non-linearity (BSL)2 Hysteresis and repeatability Ratiometricity error (VS = 4.75 ... 5.25 V) Current consumption (no load) Response time6 OUTLINE DRAWING mass: 4 g dimensions in mm (inches) November 2007 / 573 7/8 www.sensortechnics.com 40PC Series Fully signal conditioned pressure transducer ORDERING INFORMATION 40PC xxx x xA 40PC series Lead forming 1: unformed (straight) 2: formed away from port 3: formed towards port 2: stocking devices 1, 3: call Sensortechnics for availability Pressure range 001: 0 ... ±50 mmHg 006: 0 ... 300 mmHg 015: 0 ... 15 psi 015: 0 ... -15 psi 030: 0 ... 30 psi 100: 0 ... 100 psi 150: 0 ... 150 psi 250: 0 ... 250 psi 500: 0 ... 500 psi Pressure mode B: bidirectional gage pressure: available for ±50 mmHg only G: gage pressure V: vacuum gage: available for -15 psi only Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others. 8/8 November 2007 / 573 www.sensortechnics.com
40PC006B3A 价格&库存

很抱歉,暂时无法提供与“40PC006B3A”相匹配的价格&库存,您可以联系我们找货

免费人工找货