0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
17DUE92WJ12

17DUE92WJ12

  • 厂商:

    SIEMENS

  • 封装:

  • 描述:

    STARTER,COMBO SZ1,10-40AMPS,N4SS

  • 数据手册
  • 价格&库存
17DUE92WJ12 数据手册
Data sheet US2:17DUE92WJ12 Non-reversing motor starter Size 1 Three phase full voltage Solid-state overload relay OLRelay amp range 10-40a 24VAC 50-60HZ coil Combination type 60Amp fusible disconnect 60Amp / 250V fuse clip Encl NEMA type 4X 304 S-steel Water/dust tight non-corrosive Standard width enclosure product brand name Class 17 design of the product Non-reversing motor starter with fusible disconnect special product feature ESP200 overload relay General technical data weight [lb] Height x Width x Depth [in] 34 lb touch protection against electrical shock NA for enclosed products installation altitude [ft] at height above sea level maximum 6560 ft 24 × 11 × 8 in ambient temperature [°F] ● during storage -22 ... +149 °F ● during operation -4 ... +104 °F ambient temperature ● during storage -30 ... +65 °C ● during operation -20 ... +40 °C country of origin USA Horsepower ratings yielded mechanical performance [hp] for 3-phase AC motor ● at 200/208 V rated value 7.5 hp ● at 220/230 V rated value 7.5 hp ● at 460/480 V rated value 0 hp ● at 575/600 V rated value 0 hp Contactor size of contactor NEMA controller size 1 number of NO contacts for main contacts 3 operating voltage for main current circuit at AC at 60 Hz maximum 600 V operational current at AC at 600 V rated value 27 A mechanical service life (switching cycles) of the main contacts typical 10000000 Auxiliary contact number of NC contacts at contactor for auxiliary contacts 0 number of NO contacts at contactor for auxiliary contacts 1 number of total auxiliary contacts maximum 8 contact rating of auxiliary contacts of contactor according to UL 10A@600VAC (A600), 5A@600VDC (P600) Coil US2:17DUE92WJ12 Page 1/2 1.21.2021 Subject to change without notice © Copyright Siemens type of voltage of the control supply voltage AC control supply voltage ● at AC at 50 Hz rated value 24 V ● at AC at 60 Hz rated value 24 V holding power at AC minimum 8.6 W apparent pick-up power of magnet coil at AC 218 V·A apparent holding power of magnet coil at AC 25 V·A operating range factor control supply voltage rated value of magnet coil 0.85 ... 1.1 percental drop-out voltage of magnet coil related to the input voltage 50 % switch ON delay time 19 ... 29 ms OFF delay time 10 ... 24 ms Overload relay product function ● overload protection Yes ● phase failure detection Yes ● asymmetry detection Yes ● ground fault detection Yes ● test function Yes ● external reset Yes reset function Manual, automatic and remote trip class Class 5 / 10 / 20 (factory set) / 30 adjustable current response value current of the currentdependent overload release 10 ... 40 A tripping time at phase-loss maximum 3s relative repeat accuracy 1% product feature protective coating on printed-circuit board Yes number of NC contacts of auxiliary contacts of overload relay 1 number of NO contacts of auxiliary contacts of overload relay 1 operational current of auxiliary contacts of overload relay ● at AC at 600 V 5A ● at DC at 250 V 1A contact rating of auxiliary contacts of overload relay according to UL 5A@600VAC (B600), 1A@250VDC (R300) insulation voltage ● with single-phase operation at AC rated value 600 V ● with multi-phase operation at AC rated value 300 V Disconnect Switch response value of switch disconnector 60A / 250V design of fuse holder Class R fuse clips operating class of the fuse link Class R Enclosure degree of protection NEMA rating 4X, 304 stainless steel design of the housing Dust-tight, watertight & corrosion resistant Mounting/wiring mounting position vertical fastening method Surface mounting and installation type of electrical connection for supply voltage line-side Box lug tightening torque [lbf·in] for supply 35 ... 35 lbf·in type of connectable conductor cross-sections at line-side at AWG cables single or multi-stranded 1x (14 ... 2 AWG) temperature of the conductor for supply maximum permissible 75 °C material of the conductor for supply AL or CU type of electrical connection for load-side outgoing feeder Screw-type terminals tightening torque [lbf·in] for load-side outgoing feeder 35 ... 35 lbf·in type of connectable conductor cross-sections at AWG 1x (14 ... 2 AWG) US2:17DUE92WJ12 Page 2/3 1.21.2021 Subject to change without notice © Copyright Siemens cables for load-side outgoing feeder single or multistranded temperature of the conductor for load-side outgoing feeder maximum permissible 75 °C material of the conductor for load-side outgoing feeder AL or CU type of electrical connection of magnet coil Screw-type terminals tightening torque [lbf·in] at magnet coil 5 ... 12 lbf·in type of connectable conductor cross-sections of magnet coil at AWG cables single or multi-stranded 2x (16 ... 12 AWG) temperature of the conductor at magnet coil maximum permissible 75 °C material of the conductor at magnet coil CU type of electrical connection for auxiliary contacts Screw-type terminals tightening torque [lbf·in] at contactor for auxiliary contacts 10 ... 15 lbf·in type of connectable conductor cross-sections at contactor at AWG cables for auxiliary contacts single or multistranded 1x (12 AWG), 2x (16 ... 14 AWG), 2x (18 ... 16 AWG) temperature of the conductor at contactor for auxiliary contacts maximum permissible 75 °C material of the conductor at contactor for auxiliary contacts CU type of electrical connection at overload relay for auxiliary contacts Screw-type terminals tightening torque [lbf·in] at overload relay for auxiliary contacts 7 ... 10 lbf·in type of connectable conductor cross-sections at overload relay at AWG cables for auxiliary contacts single or multistranded 2x (20 ... 14 AWG) temperature of the conductor at overload relay for auxiliary contacts maximum permissible 75 °C material of the conductor at overload relay for auxiliary contacts CU Short-circuit current rating design of the fuse link for short-circuit protection of the main circuit required 10kA@600V (Class H or K); 100kA@600V (Class R or J) certificate of suitability NEMA ICS 2; UL 508; CSA 22.2, No.14 Further information Industrial Controls - Product Overview (Catalogs, Brochures,…) www.usa.siemens.com/iccatalog Industry Mall (Online ordering system) https://mall.industry.siemens.com/mall/en/us/Catalog/product?mlfb=US2:17DUE92WJ12 Service&Support (Manuals, Certificates, Characteristics, FAQs,...) https://support.industry.siemens.com/cs/US/en/ps/US2:17DUE92WJ12 Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...) http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=US2:17DUE92WJ12&lang=en Certificates/approvals https://support.industry.siemens.com/cs/US/en/ps/US2:17DUE92WJ12/certificate US2:17DUE92WJ12 Page 3/4 1.21.2021 Subject to change without notice © Copyright Siemens US2:17DUE92WJ12 Page 4/5 1.21.2021 Subject to change without notice © Copyright Siemens last modified: US2:17DUE92WJ12 Page 5/5 3/21/2020 1.21.2021 Subject to change without notice © Copyright Siemens
17DUE92WJ12 价格&库存

很抱歉,暂时无法提供与“17DUE92WJ12”相匹配的价格&库存,您可以联系我们找货

免费人工找货