0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
3RA23248XB302AC2

3RA23248XB302AC2

  • 厂商:

    SIEMENS

  • 封装:

  • 描述:

    CONTACTOR REV S0 12A 24VAC SPRG

  • 数据手册
  • 价格&库存
3RA23248XB302AC2 数据手册
Data sheet 3RA2324-8XB30-2AC2 Reversing contactor assembly AC-3,5,5 kW/400 V,AC24V,50/60Hz 3-pole, Size S0 Spring-type terminal electrical and mechanical interlock product brand name SIRIUS product designation Reversing contactor assembly product type designation 3RA23 manufacturer's article number ● 1 of the supplied contactor 3RT2024-2AC20 ● 2 of the supplied contactor 3RT2024-2AC20 ● of the supplied RH assembly kit 3RA2923-2AA2 General technical data size of contactor S0 product extension auxiliary switch Yes shock resistance at rectangular impulse ● at AC 7,5g / 5 ms, 4,7g / 10 ms ● at DC 10g / 5 ms, 7,5g / 10 ms shock resistance with sine pulse ● at AC 11,8g / 5 ms, 7,4g / 10 ms ● at DC 15g / 5 ms, 10g / 10 ms mechanical service life (switching cycles) ● of contactor typical 10 000 000 ● of the contactor with added auxiliary switch block typical 10 000 000 reference code acc. to IEC 81346-2 Q Substance Prohibitance (Date) 01.10.2009 00:00:00 Ambient conditions installation altitude at height above sea level maximum 2 000 m ● ambient temperature during operation -25 ... +60 °C ● ambient temperature during storage -55 ... +80 °C Main circuit number of poles for main current circuit 3 number of NO contacts for main contacts 3 number of NC contacts for main contacts 0 ● operating voltage at AC-3 rated value maximum 690 V operational current at AC-3 ● at 400 V rated value 12 A operating power ● at AC-3 — at 400 V rated value 5.5 kW — at 500 V rated value 7.5 kW 3RA23248XB302AC2 Page 1/2 1.21.2021 Subject to change without notice © Copyright Siemens — at 690 V rated value 7.5 kW ● at AC-4 at 400 V rated value 5.5 kW operating frequency at AC-3 maximum 1 000 1/h Control circuit/ Control type of voltage of the control supply voltage AC control supply voltage 1 at AC ● at 50 Hz rated value 24 V ● at 60 Hz rated value 24 V operating range factor control supply voltage rated value of magnet coil at AC ● at 50 Hz 0.8 ... 1.1 ● at 60 Hz 0.8 ... 1.1 apparent pick-up power of magnet coil at AC ● at 50 Hz 65 V·A inductive power factor with closing power of the coil ● at 50 Hz 0.82 apparent holding power of magnet coil at AC ● at 50 Hz 8.5 V·A inductive power factor with the holding power of the coil ● at 50 Hz 0.25 Auxiliary circuit number of NO contacts for auxiliary contacts ● per direction of rotation 1 ● instantaneous contact 2 contact reliability of auxiliary contacts < 1 error per 100 million operating cycles UL/CSA ratings full-load current (FLA) for 3-phase AC motor ● at 480 V rated value 11 A ● at 600 V rated value 11 A yielded mechanical performance [hp] for 3-phase AC motor ● at 220/230 V rated value 3 hp ● at 460/480 V rated value 7.5 hp ● at 575/600 V rated value 10 hp contact rating of auxiliary contacts according to UL A600 / Q600 Short-circuit protection design of the fuse link ● for short-circuit protection of the main circuit — with type of coordination 1 required gG NH 3NA, DIAZED 5SB, NEOZED 5SE: 63 A — with type of assignment 2 required gG NH 3NA, DIAZED 5SB, NEOZED 5SE: 25 A ● for short-circuit protection of the auxiliary switch required fuse gG: 10 A Installation/ mounting/ dimensions mounting position +/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface fastening method screw and snap-on mounting onto 35 mm standard mounting rail height 114 mm width 90 mm depth 97 mm required spacing ● with side-by-side mounting — forwards 6 mm — backwards 0 mm — upwards 6 mm — downwards 6 mm — at the side 6 mm ● for grounded parts — forwards 3RA23248XB302AC2 Page 2/3 6 mm 1.21.2021 Subject to change without notice © Copyright Siemens — backwards 0 mm — upwards 6 mm — at the side 6 mm — downwards 6 mm ● for live parts — forwards 6 mm — backwards 0 mm — upwards 6 mm — downwards 6 mm — at the side 6 mm Connections/ Terminals type of electrical connection for main current circuit spring-loaded terminals type of connectable conductor cross-sections ● for main contacts — solid 2x (1 ... 10 mm²) — solid or stranded 2x (1 ... 10 mm²) — finely stranded with core end processing 2x (1 ... 6 mm²) — finely stranded without core end processing 2x (1 ... 6 mm²) ● at AWG cables for main contacts 1x (18 ... 8) type of connectable conductor cross-sections ● for auxiliary contacts — solid or stranded 2x (0.5 ... 2.5 mm²) — finely stranded with core end processing 2x (0.5 ... 1.5 mm²) — finely stranded without core end processing 2x (0.5 ... 1.5 mm²) ● at AWG cables for auxiliary contacts 2x (20 ... 14) Safety related data B10 value with high demand rate acc. to SN 31920 1 000 000 proportion of dangerous failures ● with low demand rate acc. to SN 31920 40 % ● with high demand rate acc. to SN 31920 75 % failure rate [FIT] with low demand rate acc. to SN 31920 100 FIT T1 value for proof test interval or service life acc. to IEC 61508 20 y protection class IP on the front acc. to IEC 60529 IP20 touch protection on the front acc. to IEC 60529 finger-safe, for vertical contact from the front Communication/ Protocol product function bus communication Yes protocol is supported AS-Interface protocol No product function control circuit interface with IO link No Certificates/ approvals General Product Approval Declaration of Conformity Miscellaneous Test Certificates Marine / Shipping Special Test Certificate Marine / Shipping other 3RA23248XB302AC2 Page 3/4 Railway 1.21.2021 Subject to change without notice © Copyright Siemens Confirmation Vibration and Shock Further information Information- and Downloadcenter (Catalogs, Brochures,…) https://www.siemens.com/ic10 Industry Mall (Online ordering system) https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RA2324-8XB30-2AC2 Cax online generator http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RA2324-8XB30-2AC2 Service&Support (Manuals, Certificates, Characteristics, FAQs,...) https://support.industry.siemens.com/cs/ww/en/ps/3RA2324-8XB30-2AC2 Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...) http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RA2324-8XB30-2AC2&lang=en Characteristic: Tripping characteristics, I²t, Let-through current https://support.industry.siemens.com/cs/ww/en/ps/3RA2324-8XB30-2AC2/char Further characteristics (e.g. electrical endurance, switching frequency) http://www.automation.siemens.com/bilddb/index.aspx?view=Search&mlfb=3RA2324-8XB30-2AC2&objecttype=14&gridview=view1 3RA23248XB302AC2 Page 4/5 1.21.2021 Subject to change without notice © Copyright Siemens 3RA23248XB302AC2 Page 5/6 1.21.2021 Subject to change without notice © Copyright Siemens last modified: 3RA23248XB302AC2 Page 6/6 12/15/2020 1.21.2021 Subject to change without notice © Copyright Siemens
3RA23248XB302AC2 价格&库存

很抱歉,暂时无法提供与“3RA23248XB302AC2”相匹配的价格&库存,您可以联系我们找货

免费人工找货