3RT10543AB36

3RT10543AB36

  • 厂商:

    SIEMENS

  • 封装:

  • 描述:

    CONTACTOR S6 400VUC 3P 2NO 2NC C

  • 数据手册
  • 价格&库存
3RT10543AB36 数据手册
Data sheet 3RT1054-3AB36 Power contactor, AC-3 115 A, 55 kW / 400 V AC (50-60 Hz) / DC operation 23-26 V UC Auxiliary contacts 2 NO + 2 NC 3-pole, Size S6 with box terminals Drive: conventional Spring-type terminal product brand name SIRIUS product designation Power contactor product type designation 3RT1 General technical data size of contactor S6 product extension ● function module for communication No ● auxiliary switch Yes power loss [W] for rated value of the current at AC in hot operating state ● per pole power loss [W] for rated value of the current without load current share typical 21 W 7W 5.2 W surge voltage resistance ● of main circuit rated value 8 kV ● of auxiliary circuit rated value 6 kV maximum permissible voltage for safe isolation between coil and main contacts acc. to EN 60947-1 690 V shock resistance at rectangular impulse ● at AC 8,5g / 5 ms, 4,2g / 10 ms ● at DC 8,5g / 5 ms, 4,2g / 10 ms shock resistance with sine pulse ● at AC 13,4g / 5 ms, 6,5g / 10 ms ● at DC 13,4g / 5 ms, 6,5g / 10 ms mechanical service life (switching cycles) ● of contactor typical 10 000 000 ● of the contactor with added electronically optimized auxiliary switch block typical 5 000 000 ● of the contactor with added auxiliary switch block typical 10 000 000 reference code acc. to IEC 81346-2 Q Substance Prohibitance (Date) 01.05.2012 00:00:00 Ambient conditions installation altitude at height above sea level maximum 2 000 m ● ambient temperature during operation -25 ... +60 °C ● ambient temperature during storage -55 ... +80 °C Main circuit number of poles for main current circuit 3RT10543AB36 Page 1/2 3 1.21.2021 Subject to change without notice © Copyright Siemens number of NO contacts for main contacts ● operating voltage at AC-3 rated value maximum 3 1 000 V operational current ● at AC-1 at 400 V at ambient temperature 40 °C rated value 160 A ● at AC-1 — up to 690 V at ambient temperature 40 °C rated value 160 A — up to 690 V at ambient temperature 60 °C rated value 140 A — up to 1000 V at ambient temperature 40 °C rated value 80 A — up to 1000 V at ambient temperature 60 °C rated value 80 A ● at AC-3 — at 400 V rated value 115 A — at 500 V rated value 115 A — at 690 V rated value 115 A — at 1000 V rated value 53 A ● at AC-4 at 400 V rated value 97 A ● at AC-5a up to 690 V rated value 140 A ● at AC-5b up to 400 V rated value 95 A ● at AC-6a — up to 230 V for current peak value n=20 rated value 115 A — up to 400 V for current peak value n=20 rated value 115 A — up to 500 V for current peak value n=20 rated value 115 A — up to 690 V for current peak value n=20 rated value 115 A — up to 1000 V for current peak value n=20 rated value 53 A ● at AC-6a — up to 230 V for current peak value n=30 rated value 98 A — up to 400 V for current peak value n=30 rated value 98 A — up to 500 V for current peak value n=30 rated value 98 A — up to 690 V for current peak value n=30 rated value 98 A — up to 1000 V for current peak value n=30 rated value 53 A minimum cross-section in main circuit at maximum AC-1 rated value 70 mm² operational current for approx. 200000 operating cycles at AC-4 ● at 400 V rated value 54 A ● at 690 V rated value 48 A operational current ● at 1 current path at DC-1 — at 24 V rated value 160 A — at 110 V rated value 18 A — at 220 V rated value 3.4 A — at 440 V rated value 0.8 A — at 600 V rated value 0.5 A ● with 2 current paths in series at DC-1 — at 24 V rated value 160 A — at 110 V rated value 160 A — at 220 V rated value 20 A — at 440 V rated value 3.2 A 3RT10543AB36 Page 2/3 1.21.2021 Subject to change without notice © Copyright Siemens — at 600 V rated value 1.6 A ● with 3 current paths in series at DC-1 — at 24 V rated value 160 A — at 110 V rated value 160 A — at 220 V rated value 160 A — at 440 V rated value 11.5 A — at 600 V rated value 4A operational current ● at 1 current path at DC-3 at DC-5 — at 24 V rated value 160 A — at 110 V rated value 2.5 A — at 220 V rated value 0.6 A — at 440 V rated value 0.17 A — at 600 V rated value 0.12 A ● with 2 current paths in series at DC-3 at DC-5 — at 24 V rated value 160 A — at 110 V rated value 160 A — at 220 V rated value 2.5 A — at 440 V rated value 0.65 A — at 600 V rated value 0.37 A ● with 3 current paths in series at DC-3 at DC-5 — at 24 V rated value 160 A — at 110 V rated value 160 A — at 220 V rated value 160 A — at 440 V rated value 1.4 A — at 600 V rated value 0.75 A operating power ● at AC-3 — at 230 V rated value 37 kW — at 400 V rated value 55 kW — at 500 V rated value 75 kW — at 690 V rated value 110 kW — at 1000 V rated value 75 kW operating power for approx. 200000 operating cycles at AC-4 ● at 400 V rated value 29 kW ● at 690 V rated value 48 kW operating apparent power at AC-6a ● up to 230 V for current peak value n=20 rated value 40 000 kV·A ● up to 400 V for current peak value n=20 rated value 80 000 V·A ● up to 500 V for current peak value n=20 rated value 100 000 V·A ● up to 690 V for current peak value n=20 rated value 130 000 V·A ● up to 1000 V for current peak value n=20 rated value 90 000 V·A operating apparent power at AC-6a ● up to 230 V for current peak value n=30 rated value 30 000 V·A ● up to 400 V for current peak value n=30 rated value 60 000 V·A ● up to 500 V for current peak value n=30 rated value 80 000 V·A ● up to 690 V for current peak value n=30 rated value 110 000 V·A ● up to 1000 V for current peak value n=30 rated value 90 000 V·A short-time withstand current in cold operating state up to 40 °C ● limited to 1 s switching at zero current maximum 2 565 A; Use minimum cross-section acc. to AC-1 rated value ● limited to 5 s switching at zero current maximum 1 654 A; Use minimum cross-section acc. to AC-1 rated value ● limited to 10 s switching at zero current maximum 1 170 A; Use minimum cross-section acc. to AC-1 rated value ● limited to 30 s switching at zero current maximum 729 A; Use minimum cross-section acc. to AC-1 rated value ● limited to 60 s switching at zero current maximum 572 A; Use minimum cross-section acc. to AC-1 rated value no-load switching frequency 3RT10543AB36 Page 3/4 1.21.2021 Subject to change without notice © Copyright Siemens ● at AC 2 000 1/h ● at DC 2 000 1/h operating frequency ● at AC-1 maximum 800 1/h ● at AC-2 maximum 400 1/h ● at AC-3 maximum 1 000 1/h ● at AC-4 maximum 130 1/h Control circuit/ Control type of voltage of the control supply voltage AC/DC control supply voltage at AC ● at 50 Hz rated value 23 ... 26 V ● at 60 Hz rated value 23 ... 26 V control supply voltage at DC ● rated value 23 ... 26 V operating range factor control supply voltage rated value of magnet coil at DC ● initial value 0.8 ● full-scale value 1.1 operating range factor control supply voltage rated value of magnet coil at AC ● at 50 Hz 0.8 ... 1.1 ● at 60 Hz 0.8 ... 1.1 design of the surge suppressor with varistor apparent pick-up power of magnet coil at AC ● at 50 Hz 300 V·A inductive power factor with closing power of the coil ● at 50 Hz 0.9 apparent holding power of magnet coil at AC ● at 50 Hz 5.8 V·A inductive power factor with the holding power of the coil ● at 50 Hz 0.8 closing power of magnet coil at DC 360 W holding power of magnet coil at DC 5.2 W closing delay ● at AC 20 ... 95 ms ● at DC 20 ... 95 ms opening delay ● at AC 40 ... 60 ms ● at DC 40 ... 60 ms arcing time 10 ... 15 ms control version of the switch operating mechanism Standard A1 - A2 Auxiliary circuit number of NC contacts for auxiliary contacts instantaneous contact 2 number of NO contacts for auxiliary contacts instantaneous contact 2 operational current at AC-12 maximum 10 A operational current at AC-15 ● at 230 V rated value 6A ● at 400 V rated value 3A ● at 500 V rated value 2A ● at 690 V rated value 1A operational current at DC-12 ● at 24 V rated value 10 A ● at 48 V rated value 6A ● at 60 V rated value 6A ● at 110 V rated value 3A ● at 125 V rated value 2A 3RT10543AB36 Page 4/5 1.21.2021 Subject to change without notice © Copyright Siemens ● at 220 V rated value 1A ● at 600 V rated value 0.15 A operational current at DC-13 ● at 24 V rated value 10 A ● at 48 V rated value 2A ● at 60 V rated value 2A ● at 110 V rated value 1A ● at 125 V rated value 0.9 A ● at 220 V rated value 0.3 A ● at 600 V rated value 0.1 A contact reliability of auxiliary contacts 1 faulty switching per 100 million (17 V, 1 mA) UL/CSA ratings full-load current (FLA) for 3-phase AC motor ● at 480 V rated value 124 A ● at 600 V rated value 125 A yielded mechanical performance [hp] ● for single-phase AC motor — at 230 V rated value 25 hp ● for 3-phase AC motor — at 200/208 V rated value 40 hp — at 220/230 V rated value 50 hp — at 460/480 V rated value 100 hp — at 575/600 V rated value 125 hp contact rating of auxiliary contacts according to UL A600 / Q600 Short-circuit protection design of the fuse link ● for short-circuit protection of the main circuit — with type of coordination 1 required gG: 355 A (690 V, 100 kA) — with type of assignment 2 required gG: 250 A (690 V, 100 kA), aM: 200 A (690 V, 50 kA), BS88: 250 A (415 V, 50 kA) ● for short-circuit protection of the auxiliary switch required gG: 10 A (500 V, 1 kA) Installation/ mounting/ dimensions mounting position with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back fastening method screw fixing ● side-by-side mounting Yes height 172 mm width 120 mm depth 170 mm required spacing ● with side-by-side mounting — forwards 20 mm — upwards 10 mm — downwards 10 mm — at the side 0 mm ● for grounded parts — forwards 20 mm — upwards 10 mm — at the side 10 mm — downwards 10 mm ● for live parts — forwards 20 mm — upwards 10 mm — downwards 10 mm — at the side 10 mm Connections/ Terminals type of electrical connection 3RT10543AB36 Page 5/6 1.21.2021 Subject to change without notice © Copyright Siemens ● for main current circuit box terminal ● for auxiliary and control circuit spring-loaded terminals ● at contactor for auxiliary contacts Spring-type terminals ● of magnet coil Spring-type terminals type of connectable conductor cross-sections ● for main contacts — stranded max. 1x 50, 1x 70 mm² — finely stranded with core end processing max. 1x 50, 1x 70 mm² — finely stranded without core end processing max. 1x 50, 1x 70 mm² ● at AWG cables for main contacts 2x 1/0 connectable conductor cross-section for main contacts ● stranded 16 ... 70 mm² ● finely stranded with core end processing 16 ... 70 mm² ● finely stranded without core end processing 16 ... 70 mm² connectable conductor cross-section for auxiliary contacts ● solid or stranded 0.25 ... 2.5 mm² ● finely stranded with core end processing 0.25 ... 1.5 mm² ● finely stranded without core end processing 0.25 ... 2.5 mm² type of connectable conductor cross-sections ● for auxiliary contacts — solid 2x (0.25 ... 2.5 mm²) — solid or stranded 2x (0,25 ... 2,5 mm²) — finely stranded with core end processing 2x (0.25 ... 1.5 mm²) — finely stranded without core end processing 2x (0.25 ... 2.5 mm²) ● at AWG cables for auxiliary contacts 2x (24 ... 14) ● AWG number as coded connectable conductor cross section for auxiliary contacts 24 ... 14 Safety related data B10 value with high demand rate acc. to SN 31920 1 000 000 product function ● mirror contact acc. to IEC 60947-4-1 Yes ● positively driven operation acc. to IEC 60947-5-1 No protection class IP on the front acc. to IEC 60529 IP20 touch protection on the front acc. to IEC 60529 finger-safe, for vertical contact from the front suitability for use safety-related switching OFF Yes Certificates/ approvals General Product Approval EMC KC Declaration of Conformity Miscellaneous Marine / Shipping 3RT10543AB36 Page 6/7 Test Certificates Special Test Certificate Marine / Shipping Type Test Certificates/Test Report other Railway 1.21.2021 Subject to change without notice © Copyright Siemens Confirmation Miscellaneous Miscellaneous Confirmation Special Test Certificate Further information Information- and Downloadcenter (Catalogs, Brochures,…) https://www.siemens.com/ic10 Industry Mall (Online ordering system) https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RT1054-3AB36 Cax online generator http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RT1054-3AB36 Service&Support (Manuals, Certificates, Characteristics, FAQs,...) https://support.industry.siemens.com/cs/ww/en/ps/3RT1054-3AB36 Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...) http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RT1054-3AB36&lang=en Characteristic: Tripping characteristics, I²t, Let-through current https://support.industry.siemens.com/cs/ww/en/ps/3RT1054-3AB36/char Further characteristics (e.g. electrical endurance, switching frequency) http://www.automation.siemens.com/bilddb/index.aspx?view=Search&mlfb=3RT1054-3AB36&objecttype=14&gridview=view1 3RT10543AB36 Page 7/8 1.21.2021 Subject to change without notice © Copyright Siemens last modified: 1/18/2021 3RT10543AB36 Page 8/8 1.21.2021 Subject to change without notice © Copyright Siemens
3RT10543AB36 价格&库存

很抱歉,暂时无法提供与“3RT10543AB36”相匹配的价格&库存,您可以联系我们找货

免费人工找货