0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
3RT1065-6NP36

3RT1065-6NP36

  • 厂商:

    SIEMENS

  • 封装:

  • 描述:

    CONTACTOR S10 265A 200-277VUC 3P

  • 数据手册
  • 价格&库存
3RT1065-6NP36 数据手册
Data sheet 3RT1065-6NP36 Power contactor, AC-3 265 A, 132 kW / 400 V AC (50-60 Hz) / DC operation 200-277 V UC Auxiliary contacts 2 NO + 2 NC 3-pole, Size S10 Busbar connections Drive: electronic with PLC interface 24 V DC screw terminal product brand name SIRIUS product designation Power contactor product type designation 3RT1 General technical data size of contactor S10 product extension ● function module for communication No ● auxiliary switch Yes power loss [W] for rated value of the current at AC in hot operating state ● per pole power loss [W] for rated value of the current without load current share typical 54 W 18 W 3.4 W surge voltage resistance ● of main circuit rated value 8 kV ● of auxiliary circuit rated value 6 kV maximum permissible voltage for safe isolation between coil and main contacts acc. to EN 60947-1 690 V shock resistance at rectangular impulse ● at AC 8,5g / 5 ms, 4,2g / 10 ms ● at DC 8,5g / 5 ms, 4,2g / 10 ms shock resistance with sine pulse ● at AC 13,4g / 5 ms, 6,5g / 10 ms ● at DC 13,4g / 5 ms, 6,5g / 10 ms mechanical service life (switching cycles) ● of contactor typical 10 000 000 ● of the contactor with added electronically optimized auxiliary switch block typical 5 000 000 ● of the contactor with added auxiliary switch block typical 10 000 000 reference code acc. to IEC 81346-2 Q Ambient conditions installation altitude at height above sea level maximum 2 000 m ● ambient temperature during operation -25 ... +60 °C ● ambient temperature during storage -55 ... +80 °C Main circuit number of poles for main current circuit 3 number of NO contacts for main contacts 3 3RT10656NP36 Page 1/2 12.21.2020 Subject to change without notice © Copyright Siemens ● operating voltage at AC-3 rated value maximum 1 000 V operational current ● at AC-1 at 400 V at ambient temperature 40 °C rated value 330 A ● at AC-1 — up to 690 V at ambient temperature 40 °C rated value 330 A — up to 690 V at ambient temperature 60 °C rated value 300 A — up to 1000 V at ambient temperature 40 °C rated value 150 A — up to 1000 V at ambient temperature 60 °C rated value 150 A ● at AC-3 — at 400 V rated value 265 A — at 500 V rated value 265 A — at 690 V rated value 265 A — at 1000 V rated value 95 A ● at AC-4 at 400 V rated value 230 A ● at AC-5a up to 690 V rated value 290 A ● at AC-5b up to 400 V rated value 219 A ● at AC-6a — up to 230 V for current peak value n=20 rated value 265 A — up to 400 V for current peak value n=20 rated value 265 A — up to 500 V for current peak value n=20 rated value 265 A — up to 690 V for current peak value n=20 rated value 265 A — up to 1000 V for current peak value n=20 rated value 95 A ● at AC-6a — up to 230 V for current peak value n=30 rated value 184 A — up to 400 V for current peak value n=30 rated value 184 A — up to 500 V for current peak value n=30 rated value 184 A — up to 690 V for current peak value n=30 rated value 184 A — up to 1000 V for current peak value n=30 rated value 95 A minimum cross-section in main circuit at maximum AC-1 rated value 185 mm² operational current for approx. 200000 operating cycles at AC-4 ● at 400 V rated value 117 A ● at 690 V rated value 105 A operational current ● at 1 current path at DC-1 — at 24 V rated value 300 A — at 110 V rated value 33 A — at 220 V rated value 3.8 A — at 440 V rated value 0.9 A — at 600 V rated value 0.6 A ● with 2 current paths in series at DC-1 — at 24 V rated value 300 A — at 110 V rated value 300 A — at 220 V rated value 300 A — at 440 V rated value 4A — at 600 V rated value 2A 3RT10656NP36 Page 2/3 12.21.2020 Subject to change without notice © Copyright Siemens ● with 3 current paths in series at DC-1 — at 24 V rated value 300 A — at 110 V rated value 300 A — at 220 V rated value 300 A — at 440 V rated value 11 A — at 600 V rated value 5.2 A operational current ● at 1 current path at DC-3 at DC-5 — at 24 V rated value 300 A — at 110 V rated value 3A — at 220 V rated value 0.6 A — at 440 V rated value 0.18 A — at 600 V rated value 0.125 A ● with 2 current paths in series at DC-3 at DC-5 — at 24 V rated value 300 A — at 110 V rated value 300 A — at 220 V rated value 2.5 A — at 440 V rated value 0.65 A — at 600 V rated value 0.37 A ● with 3 current paths in series at DC-3 at DC-5 — at 24 V rated value 300 A — at 110 V rated value 300 A — at 220 V rated value 300 A — at 440 V rated value 1.4 A — at 600 V rated value 0.75 A operating power ● at AC-3 — at 230 V rated value 75 kW — at 400 V rated value 132 kW — at 500 V rated value 160 kW — at 690 V rated value 250 kW — at 1000 V rated value 132 kW operating power for approx. 200000 operating cycles at AC-4 ● at 400 V rated value 66 kW ● at 690 V rated value 102 kW operating apparent power at AC-6a ● up to 230 V for current peak value n=20 rated value 100 000 kV·A ● up to 400 V for current peak value n=20 rated value 180 000 V·A ● up to 500 V for current peak value n=20 rated value 220 000 V·A ● up to 690 V for current peak value n=20 rated value 310 000 V·A ● up to 1000 V for current peak value n=20 rated value 160 000 V·A operating apparent power at AC-6a ● up to 230 V for current peak value n=30 rated value 70 000 V·A ● up to 400 V for current peak value n=30 rated value 120 000 V·A ● up to 500 V for current peak value n=30 rated value 150 000 V·A ● up to 690 V for current peak value n=30 rated value 220 000 V·A ● up to 1000 V for current peak value n=30 rated value 160 000 V·A short-time withstand current in cold operating state up to 40 °C ● limited to 1 s switching at zero current maximum 4 880 A; Use minimum cross-section acc. to AC-1 rated value ● limited to 5 s switching at zero current maximum 4 045 A; Use minimum cross-section acc. to AC-1 rated value ● limited to 10 s switching at zero current maximum 2 785 A; Use minimum cross-section acc. to AC-1 rated value ● limited to 30 s switching at zero current maximum 1 664 A; Use minimum cross-section acc. to AC-1 rated value ● limited to 60 s switching at zero current maximum 1 276 A; Use minimum cross-section acc. to AC-1 rated value no-load switching frequency ● at AC 1 000 1/h 3RT10656NP36 Page 3/4 12.21.2020 Subject to change without notice © Copyright Siemens ● at DC 1 000 1/h operating frequency ● at AC-1 maximum 800 1/h ● at AC-2 maximum 300 1/h ● at AC-3 maximum 700 1/h ● at AC-4 maximum 130 1/h Control circuit/ Control type of voltage of the control supply voltage AC/DC control supply voltage at AC ● at 50 Hz rated value 200 ... 277 V ● at 60 Hz rated value 200 ... 277 V control supply voltage at DC ● rated value 200 ... 277 V type of PLC-control input acc. to IEC 60947-1 Type 2 consumed current at PLC-control input acc. to IEC 60947-1 maximum 20 mA voltage at PLC-control input rated value 24 V operating range factor of the voltage at PLC-control input 0.8 ... 1.1 operating range factor control supply voltage rated value of magnet coil at DC ● initial value 0.8 ● full-scale value 1.1 operating range factor control supply voltage rated value of magnet coil at AC ● at 50 Hz 0.8 ... 1.1 ● at 60 Hz 0.8 ... 1.1 design of the surge suppressor with varistor apparent pick-up power of magnet coil at AC ● at 50 Hz 530 V·A inductive power factor with closing power of the coil ● at 50 Hz 0.8 apparent holding power of magnet coil at AC ● at 50 Hz 5 V·A inductive power factor with the holding power of the coil ● at 50 Hz 0.5 closing power of magnet coil at DC 580 W holding power of magnet coil at DC 3.4 W closing delay ● at AC 45 ... 80 ms ● at DC 45 ... 80 ms opening delay ● at AC 80 ... 100 ms ● at DC 80 ... 100 ms arcing time 10 ... 15 ms control version of the switch operating mechanism PLC-IN or Standard A1 - A2 (adjustable) Auxiliary circuit number of NC contacts for auxiliary contacts instantaneous contact 2 number of NO contacts for auxiliary contacts instantaneous contact 2 operational current at AC-12 maximum 10 A operational current at AC-15 ● at 230 V rated value 6A ● at 400 V rated value 3A ● at 500 V rated value 2A ● at 690 V rated value 1A operational current at DC-12 ● at 24 V rated value 3RT10656NP36 Page 4/5 10 A 12.21.2020 Subject to change without notice © Copyright Siemens ● at 48 V rated value 6A ● at 60 V rated value 6A ● at 110 V rated value 3A ● at 125 V rated value 2A ● at 220 V rated value 1A ● at 600 V rated value 0.15 A operational current at DC-13 ● at 24 V rated value 10 A ● at 48 V rated value 2A ● at 60 V rated value 2A ● at 110 V rated value 1A ● at 125 V rated value 0.9 A ● at 220 V rated value 0.3 A ● at 600 V rated value 0.1 A contact reliability of auxiliary contacts 1 faulty switching per 100 million (17 V, 1 mA) UL/CSA ratings full-load current (FLA) for 3-phase AC motor ● at 480 V rated value 240 A ● at 600 V rated value 242 A yielded mechanical performance [hp] ● for 3-phase AC motor — at 200/208 V rated value 75 hp — at 220/230 V rated value 100 hp — at 460/480 V rated value 200 hp — at 575/600 V rated value 250 hp contact rating of auxiliary contacts according to UL A600 / Q600 Short-circuit protection design of the fuse link ● for short-circuit protection of the main circuit — with type of coordination 1 required gG: 500 A (690 V, 100 kA) — with type of assignment 2 required gG: 400 A (690 V, 100 kA), aM: 315 A (690 V, 50 kA), BS88: 400 A (415 V, 50 kA) ● for short-circuit protection of the auxiliary switch required gG: 10 A (500 V, 1 kA) Installation/ mounting/ dimensions mounting position with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back fastening method screw fixing ● side-by-side mounting Yes height 210 mm width 145 mm depth 202 mm required spacing ● with side-by-side mounting — forwards 20 mm — upwards 10 mm — downwards 10 mm — at the side 0 mm ● for grounded parts — forwards 20 mm — upwards 10 mm — at the side 10 mm — downwards 10 mm ● for live parts — forwards 20 mm — upwards 10 mm — downwards 10 mm — at the side 10 mm 3RT10656NP36 Page 5/6 12.21.2020 Subject to change without notice © Copyright Siemens Connections/ Terminals width of connection bar 25 mm thickness of connection bar 6 mm diameter of holes 11 mm number of holes 1 type of electrical connection ● for main current circuit Connection bar ● for auxiliary and control circuit screw-type terminals ● at contactor for auxiliary contacts Screw-type terminals ● of magnet coil Screw-type terminals type of connectable conductor cross-sections ● at AWG cables for main contacts 2/0 ... 500 kcmil connectable conductor cross-section for main contacts ● stranded 70 ... 240 mm² connectable conductor cross-section for auxiliary contacts ● solid or stranded 0.5 ... 4 mm² ● finely stranded with core end processing 0.5 ... 2.5 mm² type of connectable conductor cross-sections ● for auxiliary contacts — solid 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²) — solid or stranded 2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²) — finely stranded with core end processing 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²) ● at AWG cables for auxiliary contacts 2x (20 ... 16), 2x (18 ... 14), 1x 12 ● AWG number as coded connectable conductor cross section for auxiliary contacts 18 ... 14 Safety related data B10 value with high demand rate acc. to SN 31920 1 000 000 product function ● mirror contact acc. to IEC 60947-4-1 Yes ● positively driven operation acc. to IEC 60947-5-1 No protection class IP on the front acc. to IEC 60529 IP00; IP20 with box terminal/cover touch protection on the front acc. to IEC 60529 finger-safe, for vertical contact from the front with box terminal/cover suitability for use safety-related switching OFF Yes Certificates/ approvals General Product Approval EMC KC Declaration of Conformity Miscellaneous Marine / Shipping Type Test Certificates/Test Report Marine / Shipping Special Test Certificate other Confirmation 3RT10656NP36 Page 6/7 Test Certificates Railway Miscellaneous Miscellaneous 12.21.2020 Confirmation Special Test Certificate Subject to change without notice © Copyright Siemens Further information Information- and Downloadcenter (Catalogs, Brochures,…) https://www.siemens.com/ic10 Industry Mall (Online ordering system) https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RT1065-6NP36 Cax online generator http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RT1065-6NP36 Service&Support (Manuals, Certificates, Characteristics, FAQs,...) https://support.industry.siemens.com/cs/ww/en/ps/3RT1065-6NP36 Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...) http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RT1065-6NP36&lang=en Characteristic: Tripping characteristics, I²t, Let-through current https://support.industry.siemens.com/cs/ww/en/ps/3RT1065-6NP36/char Further characteristics (e.g. electrical endurance, switching frequency) http://www.automation.siemens.com/bilddb/index.aspx?view=Search&mlfb=3RT1065-6NP36&objecttype=14&gridview=view1 3RT10656NP36 Page 7/8 12.21.2020 Subject to change without notice © Copyright Siemens last modified: 3RT10656NP36 Page 8/8 12/18/2020 12.21.2020 Subject to change without notice © Copyright Siemens
3RT1065-6NP36 价格&库存

很抱歉,暂时无法提供与“3RT1065-6NP36”相匹配的价格&库存,您可以联系我们找货

免费人工找货