6EP71336AE000BN0

6EP71336AE000BN0

  • 厂商:

    SIEMENS

  • 封装:

  • 描述:

    SIMATIC ET 200SP PS 24V/10A

  • 数据手册
  • 价格&库存
6EP71336AE000BN0 数据手册
Data sheet 6EP7133-6AE00-0BN0 SIMATIC ET 200SP PS/1AC/24VDC/10A SIMATIC ET 200SP PS 24V/10A Stabilized power supply Input: 120/230 V AC Output: 24 V DC/10 A Input Input ● Note 1-phase AC Automatic range selection supply voltage ● 1 at AC rated value 120 V ● 2 at AC rated value 230 V input voltage ● 1 at AC 85 ... 132 V ● 2 at AC 170 ... 264 V Wide-range input No Overvoltage resistance 2.3 × Vin rated, 1.3 ms Mains buffering at Vin = 93/187 V Mains buffering at Iout rated, min. 20 ms; at Vin = 93/187 V Rated line frequency 1 50 Hz Rated line frequency 2 60 Hz Rated line range 47 ... 63 Hz input current ● at rated input voltage 120 V 4.34 A ● at rated input voltage 230 V 1.92 A Switch-on current limiting (+25 °C), max. 60 A I²t, max. 6.3 A²·s Built-in incoming fuse T 6.3 A/250 V (not accessible) Protection in the mains power input (IEC 898) recommended LS switch: B/C 10 A/6 A Output Output Controlled, isolated DC voltage Rated voltage Vout DC 24 V Total tolerance, static ± 3% Static mains compensation, approx. 0.1 % Static load balancing, approx. 1% Residual ripple peak-peak, max. 150 mV Residual ripple peak-peak, typ. 50 mV Spikes peak-peak, max. (bandwidth: 20 MHz) 240 mV Spikes peak-peak, typ. (bandwidth: 20 MHz) 150 mV Adjustment range 22.8 ... 28 V 6EP71336AE000BN0 Page 1/2 12.18.2020 Subject to change without notice © Copyright Siemens product function output voltage adjustable Yes Output voltage setting via potentiometer Status display Green LED for 24 V OK Signaling Relay contact (NO contact, rating 60 V DC/ 0.3 A) for "24 V OK" On/off behavior Overshoot of Vout < 3 % Startup delay, max. 0.3 s Voltage rise, typ. 30 ms Rated current value Iout rated 10 A Current range 0 ... 12 A ● Note supplied active power typical 10 A up to +60°C; +60 ... +70 °C: Derating 3%/K 240 W short-term overload current ● on short-circuiting during the start-up typical 30 A ● at short-circuit during operation typical 30 A duration of overloading capability for excess current ● on short-circuiting during the start-up 750 ms ● at short-circuit during operation 800 ms Parallel switching for enhanced performance Yes Numbers of parallel switchable units for enhanced performance 2 Efficiency Efficiency at Vout rated, Iout rated, approx. 90 % Power loss at Vout rated, Iout rated, approx. 26 W power loss [W] during no-load operation maximum 2.8 W Closed-loop control Dynamic mains compensation (Vin rated ±15 %), max. 0.3 % Dynamic load smoothing (Iout: 10/90/10 %), Uout ± typ. 3% Load step setting time 10 to 90%, typ. 1 ms Load step setting time 90 to 10%, typ. 1 ms Protection and monitoring Output overvoltage protection protection against overvoltage in case of internal fault Vout < 31.8 V Current limitation 14 ... 15 A property of the output short-circuit proof Yes Short-circuit protection Constant current characteristic enduring short circuit current RMS value ● typical 14.1 A overcurrent overload capability in normal operation overload capability 150 % Iout rated up to 5 s/min Overload/short-circuit indicator - Safety Primary/secondary isolation Yes galvanic isolation Safety extra-low output voltage Uout acc. to EN 60950-1 and EN 50178 Protection class Class I leakage current ● maximum 3.5 mA ● typical 1 mA Degree of protection (EN 60529) IP20 Approvals CE mark Yes UL/cUL (CSA) approval cULus-Listed (UL61010-2-201, CSA C22.2 No.142), cCSAus (CSA C22.2 No. 60950-1, UL 60950-1) certificate of suitability NEC Class 2 No CB approval Yes Marine approval BV, DNV GL EMC Emitted interference EN 61000-6-3 Class B Supply harmonics limitation EN 61000-3-2 Noise immunity EN 61000-6-2 environmental conditions 6EP71336AE000BN0 Page 2/3 12.18.2020 Subject to change without notice © Copyright Siemens ambient temperature ● during operation — Note -30 ... +70 °C with natural convection ● during transport -40 ... +85 °C ● during storage -40 ... +85 °C Humidity class according to EN 60721 Climate class 3K3, 5 … 95% no condensation Mechanics Connection technology Push-in terminals Connections ● Supply input L, N, PE: 1 push-in terminal each for 0.2 ... 2.5 mm² single-core/finely stranded ● Output +, -: 2 push-in terminals each for 0.2 ... 2.5 mm² ● Auxiliary Signaling contact: 2 push-in terminals for 0.2 ... 2.5 mm² ● signaling contact 2 push-in terminals for 0.2 ... 2.5 mm² product function ● removable terminal at input Yes ● removable terminal at output Yes width of the enclosure 160 mm height of the enclosure 117 mm depth of the enclosure 74 mm required spacing ● top 50 mm ● bottom 50 mm ● left 0 mm ● right 0 mm Weight, approx. 0.7 kg product feature of the enclosure housing can be lined up Yes Installation Snaps onto DIN rail EN 60715 35x7.5/15 electrical accessories Redundancy module, buffer module, selectivity module, DC UPS MTBF at 40 °C 1 114 510 h other information Specifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified) 6EP71336AE000BN0 Page 3/3 12.18.2020 Subject to change without notice © Copyright Siemens
6EP71336AE000BN0 价格&库存

很抱歉,暂时无法提供与“6EP71336AE000BN0”相匹配的价格&库存,您可以联系我们找货

免费人工找货