514CCC001460AAGR

514CCC001460AAGR

  • 厂商:

    SILABS(芯科科技)

  • 封装:

    SMD-6

  • 描述:

    有源晶振 3.3V SMD-6 12.42MHz

  • 详情介绍
  • 数据手册
  • 价格&库存
514CCC001460AAGR 数据手册
Si 514 A NY -F REQ U E N C Y I 2 C P R O GRAMMABLE X O (100 kH Z TO 250 MH Z ) Features        Programmable to any frequency  from 100 kHz to 250 MHz 0.026 ppb frequency tuning  resolution  Glitch suppression on OE, power on and frequency transitions  Low jitter operation 2- to 4-week lead times  Total stability includes 10-year aging  Comprehensive production test coverage includes crystal ESR and DLD On-chip LDO for power supply noise filtering 3.3, 2.5, or 1.8 V operation Differential (LVPECL, LVDS, HCSL) or CMOS output options Optional integrated 1:2 CMOS fanout buffer Industry standard 5x7, 3.2x5, and 2.5x3.2 mm packages –40 to 85 oC operation Applications All-digital PLLs DAC+ VCXO replacement  SONET/SDH/OTN  3G-SDI/HD-SDI/SDI Datacom Industrial automation  FPGA/ASIC clock generation  FPGA synchronization     Si5602 5x7mm, 3.2x5mm 2.5x3.2mm Ordering Information: See page 28. Pin Assignments: See page 27. SDA 1 6 VDD Description SCL 2 5 CLK– The Si514 user-programmable I2C XO utilizes Skyworks Solutions' advanced PLL technology to provide any frequency from 100 kHz to 250 MHz with programming resolution of 0.026 parts per billion. The Si514 uses a single integrated crystal and Skyworks Solutions’ proprietary DSPLL synthesizer to generate any frequency across this range using simple I2C commands. Ultra-fine tuning resolution replaces DACs and VCXOs with an all-digital PLL solution that improves performance where synchronization is necessary or in free-running reference clock applications. This solution provides superior supply noise rejection, simplifying low jitter clock generation in noisy environments. Crystal ESR and DLD are individually production-tested to guarantee performance and enhance reliability. The Si514 is factory-configurable for a wide variety of user specifications, including startup frequency, I2C address, supply voltage, output format, and stability. Specific configurations are factory-programmed at time of shipment, eliminating long lead times and non-recurring engineering charges associated with custom frequency oscillators. GND 3 4 CLK+ Functional Block Diagram Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • August 12, 2021 Si 514 TA B L E Section OF C ONTENTS Page 1. Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 2. Solder Reflow and Rework Requirements for 2.5x3.2 mm Packages . . . . . . . . . . . . . . 11 3. Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 3.1. Programming a New Output Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 3.2. Programming a Small Frequency Change (sub ±1000 ppm) . . . . . . . . . . . . . . . . . . 13 3.3. Programming a Large Frequency Change (> ±1000 ppm) . . . . . . . . . . . . . . . . . . . .14 4. All-Digital PLL Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 5. User Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 5.1. Register Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 5.2. Register Detailed Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 5.3. I2C Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 6. Pin Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 6.1. Dual CMOS (1:2 Fanout Buffer) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 7. Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 8. Package Outline Diagram: 5 x 7 mm, 6-pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 9. PCB Land Pattern: 5 x 7 mm, 6-pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 10. Package Outline Diagram: 3.2 x 5.0 mm, 6-pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 11. PCB Land Pattern: 3.2 x 5.0 mm, 6-pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 12. Package Outline Diagram: 2.5 x 3.2 mm, 6-pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 13. PCB Land Pattern: 2.5 x 3.2 mm, 6-pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 14. Top Marking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 14.1. Si514 Top Marking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 14.2. Top Marking Explanation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Document Change List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 2 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • August 12, 2021 Si514 1. Electrical Specifications Table 1. Operating Specifications VDD = 1.8 V ±5%, 2.5 or 3.3 V ±10%, TA = –40 to +85 oC Parameter Supply Voltage Supply Current Symbol Test Condition Min Typ Max Units VDD 3.3 V option 2.97 3.3 3.63 V 2.5 V option 2.25 2.5 2.75 V 1.8 V option 1.71 1.8 1.89 V CMOS, 100 MHz, single-ended — 21 26 mA LVDS (output enabled) — 19 23 mA LVPECL (output enabled) — 39 43 mA HCSL (output enabled) — 41 44 mA Tristate (output disabled) — — 18 mA –40 — 85 o IDD Operating Temperature TA C Table 2. Input Characteristics VDD = 1.8 V ±5%, 2.5 or 3.3 V ±10%, TA = –40 to +85 oC Parameter Symbol Test Condition Min Typ Max Units SDA, SCL Input Voltage High VIH 0.80 x VDD — — V SDA, SCL Input Voltage Low VIL — — 0.20 x VDD V Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 3 Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • August 12, 2021 Si 514 Table 3. Output Clock Frequency Characteristics VDD = 1.8 V ±5%, 2.5 or 3.3 V ±10%, TA = –40 to +85 oC Parameter Programmable Frequency Range Frequency Reprogramming Resolution Symbol Test Condition Min Typ Max Units FO CMOS, Dual CMOS 0.1 — 212.5 MHz FO LVDS/LVPECL/HCSL 0.1 — 250 MHz — 0.026 — ppb MRES Frequency Range for Small Frequency Change (Continuous Glitchless Output) Settling time for Small Frequency Change From center frequency –1000 — +1000 ppm ±1000 ppm from center frequency — — 10 ms Frequency Stability Grade C –30 — +30 ppm Frequency Stability Grade B –50 — +50 ppm Frequency Stability Grade A –100 — +100 ppm Frequency Stability Grade C –20 — +20 ppm Frequency Stability Grade B –25 — +25 ppm Frequency Stability Grade A –50 — +50 ppm Temperature Stability Startup Time TSU Minimum VDD until output frequency (FO) within specification — — 10 ms Disable Time TD FO < 10 MHz — — 40 µs FO  10 MHz — — 5 µs FO < 10 MHz — — 60 µs FO  10 MHz — — 20 µs Enable Time TE *Note: Total stability includes initial accuracy, operating temperature, supply voltage change, load change, shock and vibration (not under operation), and 10 years aging at 40 oC. 4 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • August 12, 2021 Si514 Table 4. Output Clock Levels and Symmetry VDD = 1.8 V ±5%, 2.5 or 3.3 V ±10%, TA = –40 to +85 oC Parameter Symbol Test Condition Min Typ Max Units CMOS Output Logic High VOH 0.85 x VDD — — V CMOS Output Logic Low VOL — — 0.15 x VDD V CMOS Output Logic High Drive IOH 3.3 V –8 — — mA 2.5 V –6 — — mA 1.8 V –4 — — mA 3.3 V 8 — — mA 2.5 V 6 — — mA 1.8 V 4 — — mA 0.1 to 125 MHz, CL = 15 pF — 0.8 1.2 ns 0.1 to 212.5 MHz, CL = no load — 0.6 0.9 ns CMOS Output Logic Low Drive IOL CMOS Output Rise/Fall Time (20 to 80% VDD) TR/TF LVPECL/HCSL Output Rise/Fall Time (20 to 80% VDD) LVDS Output Rise/Fall Time (20 to 80% VDD) LVPECL Output Common Mode TR/TF — — 565 ps TR/TF — — 800 ps VOC 50  to VDD – 2 V, single-ended — VDD – 1.4 V — V LVPECL Output Swing VO 50  to VDD – 2 V, single-ended 0.55 0.8 0.90 VPPSE LVDS Output Common Mode VOC 100  line-line, 3.3/2.5 V 1.13 1.23 1.33 V 100  line-line, 1.8 V 0.83 0.92 1.00 V LVDS Output Swing VO Single-ended 100 differential termination 0.25 0.35 0.45 VPPSE HCSL Output Common Mode HCSL Output Swing VOC 50 to ground 0.35 0.38 0.42 V VO Single-ended 0.58 0.73 0.85 VPPSE Duty Cycle DC 48 50 52 % Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 5 Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • August 12, 2021 Si 514 Table 5. Output Clock Jitter and Phase Noise (LVPECL) VDD = 2.5 or 3.3 V ±10%, TA = –40 to +85 oC; Output Format = LVPECL Parameter Symbol Test Condition Min Typ Max Units Period Jitter (RMS) JPRMS 10 k samples1 — — 1.3 ps Period Jitter (Pk-Pk) JPPKPK 10 k samples1 — — 11 ps 1.875 MHz to 20 MHz integration bandwidth2 (brickwall) — 0.31 0.5 ps 12 kHz to 20 MHz integration bandwidth2 — 0.8 1.0 ps 100 Hz — –86 — dBc/Hz 1 kHz — –109 — dBc/Hz 10 kHz — –116 — dBc/Hz 100 kHz — –123 — dBc/Hz 1 MHz — –136 — dBc/Hz 10 kHz sinusoidal noise — 3.0 — ps 100 kHz sinusoidal noise — 3.5 — ps 500 kHz sinusoidal noise — 3.5 — ps 1 MHz sinusoidal noise — 3.5 — ps LVPECL output, 156.25 MHz, offset > 10 kHz — –75 — dBc Phase Jitter (RMS) Phase Noise, 156.25 MHz Additive RMS Jitter Due to Power Supply Noise3 Spurious φJ φN JPSR SPR Notes: 1. Applies to output frequencies: 74.17582, 74.25, 75, 77.76, 100, 106.25, 125, 148.35165, 148.5, 150, 155.52, 156.25, 212.5, 250 MHz. 2. Applies to output frequencies: 100, 106.25, 125, 148.35165, 148.5, 150, 155.52, 156.25, 212.5 and 250 MHz. 3. 156.25 MHz. Increase in jitter on output clock due to sinewave noise added to VDD (2.5/3.3 V = 100 mVPP). 6 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • August 12, 2021 Si514 Table 6. Output Clock Jitter and Phase Noise (LVDS) VDD = 1.8 V ±5%, 2.5 or 3.3 V ±10%, TA = –40 to +85 oC; Output Format = LVDS Symbol Test Condition Min Typ Max Unit Period Jitter (RMS) JPRMS 10k samples1 — — 2.1 ps Period Jitter (Pk-Pk) JPPKPK 10k samples1 — — 18 ps Phase Jitter (RMS) φJ 1.875 MHz to 20 MHz integration bandwidth2 (brickwall) — 0.25 0.55 ps 12 kHz to 20 MHz integration bandwidth2 (brickwall) — 0.8 1.0 ps 100 Hz — –86 — dBc/Hz 1 kHz — –109 — dBc/Hz 10 kHz — –116 — dBc/Hz 100 kHz — –123 — dBc/Hz 1 MHz — –136 — dBc/Hz LVPECL output, 156.25 MHz, offset>10 kHz — –75 — dBc Parameter Phase Noise, 156.25 MHz Spurious φN SPR Notes: 1. Applies to output frequencies: 74.17582, 74.25, 75, 77.76, 100, 106.25, 125, 148.35165, 148.5, 150, 155.52, 156.25, 212.5, 250 MHz. 2. Applies to output frequencies: 100, 106.25, 125, 148.35165, 148.5, 150, 155.52, 156.25, 212.5 and 250 MHz. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 7 Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • August 12, 2021 Si 514 Table 7. Output Clock Jitter and Phase Noise (HCSL) VDD = 1.8 V ±5%, 2.5 or 3.3 V ±10%, TA = –40 to +85 oC; Output Format = HCSL Symbol Test Condition Min Typ Max Unit Period Jitter (RMS) JPRMS 10k samples* — — 1.2 ps Period Jitter (Pk-Pk) JPPKPK 10k samples* — — 11 ps Phase Jitter (RMS) φJ 1.875 MHz to 20 MHz integration bandwidth*(brickwall) — 0.25 0.30 ps 12 kHz to 20 MHz integration bandwidth* (brickwall) — 0.8 1.0 ps 100 Hz — –90 — dBc/Hz 1 kHz — –112 — dBc/Hz 10 kHz — –120 — dBc/Hz 100 kHz — –127 — dBc/Hz 1 MHz — –140 — dBc/Hz LVPECL output, 156.25 MHz, offset>10 kHz — –75 — dBc Parameter Phase Noise, 156.25 MHz Spurious φN SPR *Note: Applies to an output frequency of 100 MHz. 8 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • August 12, 2021 Si514 Table 8. Output Clock Jitter and Phase Noise (CMOS, Dual CMOS) VDD = 1.8 V ±5%, 2.5 or 3.3 V ±10%, TA = –40 to +85 oC; Output Format = CMOS, Dual CMOS Parameter Symbol Test Condition Min Typ Max Unit φJ 1.875 MHz to 20 MHz integration bandwidth2 (brickwall) — 0.25 0.35 ps 12 kHz to 20 MHz integration bandwidth2 (brickwall) — 0.8 1.0 ps 100 Hz — –86 — dBc/Hz 1 kHz — –108 — dBc/Hz 10 kHz — –115 — dBc/Hz 100 kHz — –123 — dBc/Hz 1 MHz — –136 — dBc/Hz LVPECL output, 156.25 MHz, offset>10 kHz — –75 — dBc Phase Jitter (RMS) Phase Noise, 156.25 MHz Spurious φN SPR Notes: 1. Applies to output frequencies: 74.17582, 74.25, 75, 77.76, 100, 106.25, 125, 148.35165, 148.5, 150, 155.52, 156.25, 212.5 MHz. 2. Applies to output frequencies: 100, 106.25, 125, 148.35165, 148.5, 150, 155.52, 156.25, 212.5 MHz. Table 9. Environmental Compliance and Package Information Parameter Conditions/Test Method Mechanical Shock MIL-STD-883, Method 2002 Mechanical Vibration MIL-STD-883, Method 2007 Solderability MIL-STD-883, Method 2003 Gross and Fine Leak MIL-STD-883, Method 1014 Resistance to Solder Heat MIL-STD-883, Method 2036 Contact Pads Gold over Nickel Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 9 Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • August 12, 2021 Si 514 Table 10. Thermal Characteristics Parameter Symbol Test Condition Value Units CLCC, Thermal Resistance Junction to Ambient* JA Still air 110 °C/W 2x5 x 3.2 mm, Thermal Resistance Junction to Ambient* JA Still air 164 °C/W *Note: Applies to 5 x 7 and 3.2 x 5 mm packages. Table 11. Absolute Maximum Ratings1 Parameter Symbol Rating TAMAX 85 TS –55 to +125 oC VDD –0.5 to +3.8 V VI –0.5 to VDD + 0.3 V ESD Sensitivity (HBM, per JESD22-A114) HBM 2 kV Soldering Temperature (Pb-free profile)2 TPEAK 260 TP 20–40 Maximum Operating Temperature Storage Temperature Supply Voltage Input Voltage (any input pin) Soldering Temperature Time at TPEAK (Pb-free profile)2 Units o C o C sec Notes: 1. Stresses beyond those listed in this table may cause permanent damage to the device. Functional operation or specification compliance is not implied at these conditions. Exposure to maximum rating conditions for extended periods may affect device reliability. 2. The device is compliant with JEDEC J-STD-020E. 10 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • August 12, 2021 Si514 2. Solder Reflow and Rework Requirements for 2.5x3.2 mm Packages Reflow of Skyworks Solutions' components should be done in a manner consistent with the IPC/JEDEC J-STD-20E standard. The temperature of the package is not to exceed the classification Temperature provided in the standard. The part should not be within -5°C of the classification or peak reflow temperature (TPEAK) for longer than 30 seconds. Key to maintaining the integrity of the component is providing uniform heating and cooling of the part during reflow and rework. Uniform heating is achieved through having a preheat soak and controlling the temperature ramps in the process. J-STD-20E provides minimum and maximum temperatures and times for the preheat/Soak step that need to be followed, even for rework. The entire assembly area should be heated during rework. Hot air should be flowed from both the bottom of the board and the top of the component. Heating from the top only will cause un-even heating of component and can lead to part integrity issues. Temperature Ramp-up rate are not to exceed 3°C/second. Temperature ramp-down rates from peak to final temperature are not to exceed 6°C/second. Time from 25°C to peak temperature is not to exceed 8 min for Pb-free solders. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 11 Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • August 12, 2021 Si 514 3. Functional Description The Si514 offers system designers a programmable, low jitter XO solution with exceptionally fine frequency tuning resolution. To enable designers to take full advantage of this flexibility and performance, Skyworks Solutions provides an easy-to-use evaluation kit and intuitive suite of Windows-based software utilities to simplify the Si514 programming process. The Si5xx-PROG-EVB kit contains the Programmable Oscillator Software suite and an EVB Driver (USBXpress®) for use with USB-equipped PCs. Go to www.skyworksinc.com/en/application-pages/Developers for more information. Alternatively, “3.1. Programming a New Output Frequency” provides designers a detailed description, along with examples, of the frequency programming requirements and process for designers who are interested in learning more about the programming algorithms implemented within the Programmable Oscillator Software suite. 3.1. Programming a New Output Frequency The output frequency (Fout) is determined by programming the feedback multiplier (M=M_Int.M_Frac), HighSpeed Divider (HS_DIV), and Low-Speed Divider (LS_DIV) according to the following formula: F XO  M F out = -------------------------------------------------HS_DIV  LS_DIV where F XO = 31.98MHz Figure 1. Block Diagram of Si514 The value of the feedback multiplier M is adjustable in the following range: 65.04065041  M  78.17385866. This keeps the VCO frequency within the range of 2080 MHz  FVCO  2500 MHz, since the VCO frequency is the product of the internal fixed-frequency crystal (FXO) and the high-resolution 29-bit fractional multiplier (M). This 29bit resolution of M allows the VCO frequency to have a frequency tuning resolution of 0.026 ppb. The device comes from the factory with a pre-programmed center frequency within the range of 100 kHz  FOUT  250 MHz, as specified by the 6-digit code in the part number. (See section “7. Ordering Information” for more information.) To change from the factory-programmed frequency to a different value, the user must follow one of two algorithms based on the magnitude of the frequency change.    12 “Small Frequency Change.” To change the frequency by < ±1000 ppm, the user must keep the same center frequency and only update the value of M. Refer to section "3.2. Programming a Small Frequency Change (sub ±1000 ppm)" on page 13. “Large Frequency Change.” To change the frequency by ±1000 ppm, the user must change the center frequency. This may require updates to the output dividers (HS_DIV and/or LS_DIV) and possibly the LP1 and Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • August 12, 2021 Si514 LP2 values, in addition to updating the value of M, which requires the VCO to be recalibrated. Refer to section "3.3. Programming a Large Frequency Change (> ±1000 ppm)" on page 14. Figure 2 provides a graphic depiction of the difference between small and large frequency changes. Range of small frequency change FCENTER -1000 ppm FVCO_MIN (2080 MHz) Small Frequency Change Large Frequency Change FCENTER +1000 ppm FCENTER F'CENTER FVCO_MAX (2500 MHz) Programming a new center frequency requires a VCO calibration and the output should be squelched Figure 2. Small vs. Large Frequency Change Illustration 3.2. Programming a Small Frequency Change (sub ±1000 ppm) The value of the feedback multiplier, M is the only parameter that needs to be updated for output frequency changes less than ±1000 ppm from the center frequency (recalibrating the VCO is NOT required). This enables the output to remain continuous during the change. For example, the output frequency can be swept continuously between 148.5 MHz and 148.352 MHz (i.e., –0.997 ppm) with no output discontinuities or glitches by changing M in either multiple steps or in a single step. For small frequency changes, each update of M requires 100 µs to settle. Note: It is not possible to implement a frequency change ≥ ±1000 ppm using multiple small frequency changes without changing the center frequency and recalibrating the VCO. Use the following procedure to make small frequency changes: 1. If the current value of M is already known, then skip to step 2; else, using the serial port, read the current M value (Registers 5-9). 2. Calculate the new value of M as follows (all values are in decimal format): a. Mcurrent = M_Int + M_Frac/229 (Eq 2.2) b. Mnew = Mcurrent x Fout_new / Fout_current (Eq 2.3) c. M_Intnew = INT[Mnew]* (Eq 2.4) d. M_Fracnew = (Mnew – INT[Mnew]) x 229 (Eq 2.5) *Where INT[n] rounds n down to the nearest integer (e.g., INT[3.9] = 3) 3. Using the I2C port, write the new value of M_Frac[23:0] (Not all registers need to be updated.) (Registers: 5, 6, 7) 4. If necessary, write new value of M_Int[2:0] and M_Frac[28:24] register. (Register 8) 5. Write M_Int[8:3]. (Register 9) Frequency changes take effect when M_Int[8:3] is written. Example 2.1: An Si514 generating a 148.5 MHz clock must be reconfigured “on-the-fly” to generate a 148.352 MHz clock. This represents a change of –0.996.633 ppm which is within the ±1000 ppm window. 1. Read the current value of M: a. Register 5 = 0xD3 (M_Frac[7:0]) b. Register 6 = 0x65 (M_Frac[15:8]) c. Register 7 = 0x7C (M_Frac[23:16]) Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 13 Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • August 12, 2021 Si 514 d. e. f. g. h. Register 8 = 0x49 (M_Int[2:0],M_Frac[28:24]) Register 9 = 0x09 (M_Int[8:3]) M_Int = 0b001001010 = 0x4A = 0d74 M_Frac = 0x097C65D3 = 159,147,475 M= M_Int + M_Frac/229 = 74 + 159,147,475/229 = 74.296435272321105 2. Calculate Mnew: a. Mnew = 74.296435272321105 x 148.352/148.5 = 74.2223889933965 b. M_Intnew = 74 = 0x4A c. M_Fracnew = 0.2223889933965 x 229 = 119,394,181 = 0x071DCF85 3. Write Mnew to Registers 5-7: a. Register 5 = 0x85 b. Register 6 = 0xCF c. Register 7 = 0x1D 4. Write Mnew to Register 8: a. Register 8 = 0x47 5. Write Mnew to Register 9: a. Register 9 = 0x09 3.3. Programming a Large Frequency Change (> ±1000 ppm) Large frequency changes are those that vary the FVCO frequency by an amount greater than ±1000 ppm from an operating FCENTER. Figure 2 illustrates the difference between large and small frequency changes. Changing from FCENTER to F'CENTER requires a calibration cycle that resets internal circuitry to establish F'CENTER as the new operating center frequency. The below steps are recommended when performing large frequency changes: 1. Disable the output: Write OE register bit to a 0 (Register 132, bit2) 2. If using one of the standard frequencies listed in Table 12, then write the new LP1, LP2, M_Frac, M_Int, HS_DIV and LS_DIV register values according to the table (be sure to write M_Int[8:3] (Register 9) after writing to the M_Frac registers (Registers 5-8)). Skip to Step 9. If the desired frequency is not in the table, then follow steps 4-8 below. 3. Determine the minimum value of LS_DIV (minimizing LS_DIV minimizes the number of dividers on the output stage, thus minimizing jitter) according to the following formula: a. LS_DIV = FVCO(MIN)/(FOUT x HS_DIV(MAX)) (Eq 2.6) b. LS_DIV = 2080/(FOUT(MHz) x 1022) (Eq 2.7) i. Since LS_DIV is restricted to: dividing by 1,2,4,8,16,32, choose the next largest value over the result derived in Eq 2.7 (e.g., if result is 4.135, choose LS_DIV = 8) 4. Determine the minimum value for HS_DIV (this optimizes timing margins) a. HS_DIV(MIN) = FVCO(MIN)/(FOUT x LS_DIV) (Eq 2.8) b. HS_DIV(MIN) = 2080/(FOUT(MHz) x LS_DIV) (Eq 2.9) i.HS_DIV(MIN) will be the next even number greater than or equal to the result derived in Eq 2.9 (keeping in the range of 10-1022) Note: SPEED_GRADE_MIN (Reg 48) ≤ LS_DIV x HS_DIV ≤ SPEED_GRADE_MAX (Reg 49); If outside this range, the output will be forced to the disabled state. 5. Determine a value for M according to the following formula (all values are in decimal format): a. M = LS_DIV x HS_DIV x FOUT/FXO (Eq 2.10) b. M = LS_DIV x HS_DIV x FOUT(MHz)/31.98 (Eq 2.11) c. M_Int = INT[M] (Eq 2.12) d. M_Frac = (M – INT[M]) x 229 (Eq 2.13) 14 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • August 12, 2021 Si514 Table 12. Standard Frequency Table DEC HEX Fout (MHz) M M_INT M_FRAC HSDIV LSDIV LP1 LP2 M_INTX M_FRACX HSDIVX LSDIVX LP1_X LP2_X 0.100000 65.04065041 65 21824021 650 5 2 2 41 14D0215 28A 5 2 2 1.544000 65.08167605 65 43849494 674 1 2 2 41 29D1716 2A2 1 2 2 2.048000 65.06466542 65 34716981 1016 0 2 2 41 211BD35 3F8 0 2 2 4.096000 65.06466542 65 34716981 508 0 2 2 41 211BD35 1FC 0 2 2 4.915200 65.16712946 65 89726943 424 0 2 2 41 5591FDF 1A8 0 2 2 19.440000 65.65103189 65 349520087 108 0 2 3 41 14D540D7 6C 0 2 3 24.576000 66.08930582 66 47945695 86 0 2 3 42 2DB97DF 56 0 2 3 25.000000 65.66604128 65 357578187 84 0 2 3 41 155035CB 54 0 2 3 27.000000 65.85365854 65 458304437 78 0 2 3 41 1B512BB5 4E 0 2 3 38.880000 65.65103189 65 349520087 54 0 2 3 41 14D540D7 36 0 2 3 44.736000 67.14596623 67 78365022 48 0 2 3 43 4ABC15E 30 0 2 3 54.000000 67.54221388 67 291098862 40 0 2 3 43 1159D0EE 28 0 2 3 62.500000 66.44777986 66 240399983 34 0 2 3 42 E54366F 22 0 2 3 65.536000 65.57698562 65 309766794 32 0 2 3 41 1276AA8A 20 0 2 3 74.175824 69.58332458 69 313169998 30 0 3 3 45 12AA984E 1E 0 3 3 74.250000 69.65290807 69 350527350 30 0 3 3 45 14E49F76 1E 0 3 3 77.760000 68.08255159 68 44319550 28 0 3 3 44 2A4433E 1C 0 3 3 106.250000 66.44777986 66 240399983 20 0 2 3 42 E54366F 14 0 2 3 125.000000 70.3564728 70 191379875 18 0 3 3 46 B6839A3 12 0 3 3 148.351648 74.22221288 74 119299633 16 0 3 4 4A 71C5E31 10 0 3 4 148.500000 74.29643527 74 159147475 16 0 3 4 4A 97C65D3 10 0 3 4 150.000000 65.66604128 65 357578187 14 0 2 3 41 155035CB E 0 2 3 155.520000 68.08255159 68 44319550 14 0 3 3 44 2A4433E E 0 3 3 156.250000 68.40212633 68 215889929 14 0 3 3 44 CDE3809 E 0 3 3 212.500000 66.44777986 66 240399983 10 0 2 3 42 E54366F A 0 2 3 250.000000 78.17385866 78 93339658 10 0 4 4 4E 590400A A 0 4 4 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 15 Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • August 12, 2021 Si 514 6. Determine values for LP1 and LP2 according to Table 13: Table 13. LP1, LP2 Values Fvco_max Fvco_min M_max M_min LP1 LP2 2500000000.00000 2425467616.18572 78.173858662 75.843265046 4 4 2425467616.18572 2332545246.89005 75.843265046 72.937624981 3 4 2332545246.89005 2170155235.53450 72.937624981 67.859763463 3 3 2170155235.53450 2087014168.27005 67.859763463 65.259980246 2 3 2087014168.27005 2080000000.00000 65.259980246 65.040650407 2 2 7. Write new LP1, LP2, M_Frac, M_Int, HS_DIV and LS_DIV register values (be sure to write M_Int[8:3] (Register 9) after writing to the M_Frac registers (Registers 5-8) 8. Write FCAL (Register 132, bit 0) to a 1 (this bit auto-resets, so it will always read as 0). 9. Enable the output: Write OE register bit to a 1. The Si514 does not automatically detect large frequency changes. The user needs to assert the FCAL register bit to initiate the calibration cycle required to re-center the VCO around the new frequency. Large frequency changes are discontinuous and output may skip to intermediate frequencies or generate glitches. Resetting the OE bit before FCAL will prevent intermediate frequencies from appearing on the output while Si514 completes a calibration cycle and settles to F'CENTER. Settling time for large frequency changes is 10 msec maximum. Example 2.2: The user has a part that is programmed with SPEED_GRADE_MIN = 20 and SPEED_GRADE_MAX = 250 that is programmed from the factory for FOUT = 50 MHz and wants to change to an STS-1 rate of 51.84 MHz. This represents a change of +36,800 ppm which exceeds ±1000 ppm and therefore requires a large frequency change process. 1. Write Reg 132, bit 2 to a 0 to disable the output. 2. Since 51.84 MHz is not in Table 2.1, the divider parameters must be calculated. 3. Calculate LS_DIV by using Eq 2.7: a. LS_DIV = 2080/(51.84 x 1022) = 0.039 b. Since 0.039 < 1, use a divide-by-one (bypass), therefore LS_DIV = 0 4. Calculate HS_DIV(MIN) by using Eq 2.9: a. HS_DIV(MIN) = 2080/(51.84 x 1) = 40.123 b. Since 40.123 > 40, use HS_DIV(MIN) = 42 = 0x2A 5. From Eq 2.11: a. M = 1 x 42 x 51.84/31.98 = 68.08255159474 b. M_Int = 68 = 0x44 c. M_Frac = 0.08255259474 x 229 = 44,320,087 = 0x2A44557 6. From Table 2.2: a. LP1 = 3 b. LP2 = 3 16 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • August 12, 2021 Si514 7. Write Registers 0, 5-11: a. Register 0 = 0x33 b. Register 5 = 0x57 (M_Frac[7:0]) c. Register 6 = 0x45 (M_Frac[15:8]) d. Register 7 = 0xA4 (M_Frac[23:16]) e. Register 8 = 0x42 (M_Int[2:0],M_Frac[28:24]) f. Register 9 = 0x05 (M_Int[8:3]) g. Register 10 = 0x2A h. Register 11 = 0x00 8. Calibrate the VCO by writing Register 132, bit 0 to a 1. 9. Enable the output by writing Register 132, bit 2 to a 1. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 17 Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • August 12, 2021 Si 514 4. All-Digital PLL Applications The Si514 uses a high resolution divider M that enables fine frequency adjustments with resolution better than 0.026 parts per billion. Fine frequency adjustments are useful when making frequency corrections that compensate for changing ambient conditions, long term aging or when locking the Si514 to an input clock reference. Figure 3 shows a typical implementation using a system IC such as an FPGA to control the output of the Si514 in a phaselocked application. Refer to “AN575: An Introduction to FPGA-Based ADPLLs” for more information. Fin ÷ Si514 SCL I2C Control SDA PD Loop Filter Command Conversion I2C Master CLK_OUT Any Frequency DSPLL FB ÷ FPGA Figure 3. All-Digital PLL Application Using Si514 with Dual CMOS Output Since small frequency changes must be within ±1000 ppm of the center frequency, HS_DIV and LS_DIV remain constant. The below expression can be used to calculate a new M2 divider value based on a desired output frequency shift, where ∆FOUT is in ppm. –6 M 2 = M 1  1 – F OUT  10  Some systems, particularly those that use feedback control, can simplify the computation by implementing an approximate frequency change based on toggling a bit position or adding/subtracting a bit to the existing M_Frac value. Since M ranges approximately ±10% between 65.04065041 and 78.17385866, the effect of changing M_Frac by a single bit depends only slightly on the absolute value of M. For M=71 near the midpoint of the range, toggling M_Frac[0] changes the output frequency by 0.026 ppb. Each higher order bit doubles the influence such that toggling M_Frac[1] is 0.052 ppb, M_Frac[2] is 0.1 ppb, etc. Figure 4 shows this trend across multiple registers generalized to M_Frac[N]. Coarse changes greater than ±1.7 ppm are possible but most applications require finer transitions. Toggling each bit involves incrementing or decrementing the bit position. Writing M_Int[8:3] in register 9 completes the operation. 1.7ppm 6.7ppb M = 71.000000000000 M_Int[8:0] = 000100111 0.026ppb M_Frac[28:0] = 00000000000000000000000000000 M_Frac[23:16] = 00000000 M_Frac[15:8] = 00000000 M_Frac[7:0] = 00000000 Figure 4. Output Frequency Change When Toggling M_Frac[N], M=71 18 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • August 12, 2021 Si514 5. User Interface 5.1. Register Map Table 14 displays the Si514 user register map. Registers not shown are reserved. Registers with reserved bits are read-modify-write. Table 14. User Register Map Address Bit 7 0 6 5 4 3 LP1[3:0] M_Frac [7:0] 6 M_Frac [15:8] 7 M_Frac [23:16] 8 M_Int [2:0] 0 M_Frac [28:24] 9 M_Int [8:3] 10 HS_DIV [7:0] 11 LS_DIV [ 2:0] 14 132 1 LP2[3:0] 5 128 2 HS_DIV [9:8] OE_STATE [1:0] RST OE FCAL Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 19 Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • August 12, 2021 Si 514 5.2. Register Detailed Description Note: Registers not shown are reserved. Registers with reserved bits are read-modify-write. Register 0. Bit 7 6 5 4 3 2 1 Name LP1[3:0] LP2[3:0] Type R/W R/W Default Varies Varies Bit Name 7:4 LP1[3:0] Sets loop compensation factor LP1. Value depends on VCO frequency. 3:0 LP2[3:0] Sets loop compensation factor LP2. Value depends on VCO frequency. 0 Function Register 5. Bit 7 6 5 4 3 Name M_Frac[7:0] Type R/W Default Varies Bit Name 7:0 M_Frac[7:0] 2 1 0 Function Fractional part of feedback divider M that sets up the output frequency. Frequency updates take effect when M_Int[8:3] is written. Register 6. Bit 6 5 4 3 Name M_Frac[15:8] Type R/W Default Varies Bit 7:0 20 7 Name 2 1 0 Function M_Frac[15:8] Fractional part of feedback divider M that sets up the output frequency. Frequency updates take effect when M_Int[8:3] is written. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • August 12, 2021 Si514 Register 7. Bit 7 6 5 4 3 Name M_Frac[23:16] Type R/W Default Varies Bit Name 7:0 2 1 0 Function M_Frac[23:16] Fractional part of feedback divider M that sets up the output frequency. Frequency updates take effect when M_Int[8:3] is written. Register 8. Bit 7 6 5 4 3 2 Name M_Int[2:0] M_Frac[28:24] Type R/W R/W Default Varies Varies 1 0 Bit Name Function 7:5 M_Int[2:0] Integer part of feedback divider M that sets the output frequency. Frequency updates take effect when M_Int[8:3] is written. 4:0 M_Frac[28:24] Fractional part of feedback divider M that sets up the output frequency. Frequency updates take effect when M_Int[8:3] is written. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 21 Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • August 12, 2021 Si 514 Register 9. Bit 7 6 5 4 3 Name 2 1 0 M_Int[8:3] Type R/W R/W R/W Default Varies Bit Name Function 7:6 Reserved 5:0 M_Int[8:3] Integer part of feedback divider M that sets the output frequency. Frequency updates take effect when M_Int[8:3] is written. Register 10. Bit 22 7 6 5 4 3 Name HS_DIV[7:0] Type R/W Default Varies 2 1 0 Bit Name Function 7:0 HS_DIV[7:0] Integer divider that divides VCO frequency and provides output to LS_DIV. Follow the large frequency change procedure when updating. The allowed values are even numbers in the range from 10 to 1022 (i.e., 10, 12, 14, 16, ...., 1022). The decimal value represents the actual divide value (i.e. 12 means divide-by-12). Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • August 12, 2021 Si514 Register 11. Bit 7 6 Name 5 4 3 2 LS_DIV[2:0] Type R/W R/W R/W R/W Varies Bit Name 7 Reserved 6:4 LS_DIV[2:0] 3:2 Reserved 1:0 HS_DIV[9:8] 0 HS_DIV[9:8] R/W Default 1 Varies Function Last output divider stage. Used during large frequency changes. To update, follow large frequency change procedure. LS_DIV value updates asynchronously. 000: divide-by-1 001: divide-by-2 010: divide-by-4 011: divide-by-8 100: divide-by-16 101: divide-by-32 All others reserved. Integer divider that divides VCO frequency and provides output to LS-DIV. Follow the large frequency change procedure when updating. The allowed values are even numbers in the range from 10 to 1022 (i.e., 10, 12, 14, 16, ..., 1022). The decimal value represents the actual divide value (i.e., 12 means divide-by-12). Register 14. Bit 7 6 Name Type 5 4 3 2 1 0 R/W R/W R/W R/W OE_STATE[1:0] R/W Default R/W R/W 0 Bit Name 7:6 Reserved 5:4 OE_STATE[1:0] 3:0 Reserved 0 Function Sets logic state of output when output disabled. 00: high impedance 10: logic low when output disabled 01: logic high when output disabled 11: reserved Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 23 Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • August 12, 2021 Si 514 Register 128. Bit 7 Name RST Type R/W Default 0 Bit Name 7 RST 6:0 Reserved 6 5 4 3 2 1 0 R/W R/W R/W R/W R/W R/W R/W 1 0 Function Global Reset. Resets all register values to default values. Self-clearing. Register 132. Bit 7 6 5 4 3 Name Type OE R/W R/W R/W R/W R/W Default 24 2 R/W 1 Bit Name 7:3 Reserved 2 OE 1 Reserved 0 FCAL FCAL R/W R/W 0 Function Output Enable. OE can stop in high, low or high impedance state. 1: Output driver enabled. 0: Output driver powered down. OE_STATE register determines output state when disabled. Initiates frequency calibration cycle. Necessary when making large frequency changes. Frequency calibration cycle takes 10 msec maximum. To prevent intermediate frequencies on the output, set disable output using OE register. Self-clearing. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • August 12, 2021 Si514 5.3. I2C Interface Configuration and operation of the Si514 is controlled by reading and writing to the RAM space using the I2C interface. The device operates in slave mode with 7-bit addressing and can operate in Standard-Mode (100 kbps) or Fast-Mode (400 kbps). Burst data transfer with auto address increments are also supported. The I2C bus consists of a bidirectional serial data line (SDA) and a serial clock input (SCL). Both the SDA and SCL pins must be connected to the VDD supply via an external pull-up as recommended by the I2C specification. The Si514 7-bit I2C slave address is user-customized during the part number configuration process. See "6. Pin Descriptions" on page 27 for more details. Data is transferred MSB first in 8-bit words as specified by the I2C specification. A write command consists of a 7bit device (slave) address + a write bit, an 8-bit register address, and 8 bits of data as shown in Figure 5. A write burst operation is also shown where every additional data word is written using an auto-incremented address. Write Operation – Single Byte S Slv Addr [6:0] 0 A Reg Addr [7:0] A Data [7:0] A P A Data [7:0] Write Operation - Burst (Auto Address Increment) S Slv Addr [6:0] 0 A Reg Addr [7:0] A Data [7:0] A P Reg Addr +1 From slave to master From master to slave 1 – Read 0 – Write A – Acknowledge (SDA LOW) N – Not Acknowledge (SDA HIGH) S – START condition P – STOP condition Figure 5. I2C Write Operation A read operation is performed in two stages. A data write is used to set the register address, then a data read is performed to retrieve the data from the set address. A read burst operation is also supported. This is shown in Figure 6. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 25 Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • August 12, 2021 Si 514 Read Operation – Single Byte S Slv Addr [6:0] 0 A Reg Addr [7:0] A S Slv Addr [6:0] 1 A Data [7:0] P N P Read Operation - Burst (Auto Address Increment) S Slv Addr [6:0] 0 A Reg Addr [7:0] A S Slv Addr [6:0] 1 A Data [7:0] A P Data [7:0] N P Reg Addr +1 From slave to master From master to slave 1 – Read 0 – Write A – Acknowledge (SDA LOW) N – Not Acknowledge (SDA HIGH) S – START condition P – STOP condition Figure 6. I2C Read Operation The timing specifications and timing diagram for the I2C bus is compatible with the I2C-Bus standard. SDA timeout is supported for compatibility with SMBus interfaces. The I2C bus can be operated at a bus voltage of 1.71 to 3.63 V and is 3.3 V tolerant. 26 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • August 12, 2021 Si514 6. Pin Descriptions SDA 1 6 VDD SCL 2 5 CLK– GND 3 4 CLK+ Table 15. Si514 Pin Descriptions Pin Name Function 1 SDA I2C Serial Data. 2 SCL I2C Serial Clock. 3 GND Electrical and Case Ground. 4 CLK+ Clock Output. 5 CLK- Complementary clock output (LVPECL, LVDS, HCSL, and Complementary dual CMOS formats). Clock output for in-phase dual CMOS format. No connect (N/C) for single-ended CMOS format. 6 VDD Power Supply Voltage. 6.1. Dual CMOS (1:2 Fanout Buffer) Dual CMOS output format ordering options support either complementary or in-phase output signals. This feature enables replacement of multiple XOs with a single Si514 device. ~ ~ Complementary Outputs In-Phase Outputs Figure 7. Integrated 1:2 CMOS Buffer Supports Complementary or In-Phase Outputs Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 27 Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • August 12, 2021 Si 514 7. Ordering Information The Si514 supports a wide variety of options including startup frequency, stability, output format, and VDD. Specific device configurations are programmed into the Si514 at time of shipment. Configurations can be specified using the Part Number Configuration chart below. Skyworks Solutions provides a web browser-based part number configuration utility to simplify this process. To access this tool refer to www.skyworksinc.com/products/timingoscillators and click “Customize” in the product table. The Si514 XO series is supplied in industry-standard, RoHScompliant, 2.5 x 3.2 mm, 3.2 x 5.0 mm, and 5 x 7 mm packages. Tape and reel packaging is an ordering option. Series Output Format Package 514 LVPECL, LVDS, HCSL, CMOS, Dual CMOS 6-pin 1st Option Code: Output Format A = Revision: A G = Temp Range: -40°C to 85°C R = Tape & Reel; Blank = Coil Tape 514 X X X XXXXXX X AGR VDD Output Format LVPECL A 3.3V B 3.3V LVDS C 3.3V CMOS D 3.3V HCSL E 2.5V LVPECL F 2.5V LVDS G 2.5V CMOS H 2.5V HCSL J 1.8V LVDS K 1.8V CMOS L 1.8V HCSL M 3.3V Dual CMOS (In-phase) N 3.3V Dual CMOS (Complementary) P 2.5V Dual CMOS (In-phase) Q 2.5V Dual CMOS (Complementary) R 1.8V Dual CMOS (In-phase) S 1.8V Dual CMOS (Complementary) 3rd Option Code: Frequency Grade CMOS (MHz) LVPECL, LVDS, HCSL (MHz) 0.1 to 212.5 0.1 to 250 A B C 0.1 to 170 0.1 to 125 Package Option Dimensions 0.1 to 170 A 5 x 7 mm 0.1 to 125 B 3.2 x 5 mm C 2.5 x 3.2 mm 6-digit Frequency and Default I2C Address Code 2nd Option Code: Frequency Stability Total Temperature A ±100ppm ±50ppm B ±50ppm ±25ppm C ±30ppm ±20ppm Code Description xxxxxx The Si514 supports a user-defined start-up frequency which must be in the same range as specified by the Frequency Grade code. A user-defined, 7-bit I2C address is supported. Each unique start-up frequency/I2C address combination is assigned a 6-digit code by: (see ** below) . ** www.skyworksinc.com/en/application-pages/timing-lookup-customize Figure 8. Part Number Convention Example orderable part number: 514ECB000107AAG supports 2.5 V LVPECL, ±30 ppm total stability, user programmable output frequency range from 100 kHz to 170 MHz, 5x7 mm package and –40 to 85 °C temperature range. The frequency code designates 10 MHz startup with I2C address of 0x55. Refer to www.silabs.com/VCXO lookup to look up the attributes of any Skyworks Solutions orderable XO/VCXO part number. Note: CMOS and Dual CMOS maximum frequency is 212.5 MHz. 28 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • August 12, 2021 Si514 8. Package Outline Diagram: 5 x 7 mm, 6-pin Figure 9 illustrates the 5 x 7 mm, 6-pin package details for the Si514. Table 16 lists the values for the dimensions shown in the illustration. Figure 9. Si514 Outline Diagram Table 16. Package Diagram Dimensions (mm) Dimension A b c D D1 e E E1 H L L1 p R aaa bbb ccc ddd eee Min 1.50 1.30 0.50 4.30 6.10 0.55 1.17 0.05 1.80 Nom 1.65 1.40 0.60 5.00 BSC 4.40 2.54 BSC 7.00 BSC 6.20 0.65 1.27 0.10 — 0.70 REF 0.15 0.15 0.10 0.10 0.05 Max 1.80 1.50 0.70 4.50 6.30 0.75 1.37 0.15 2.60 Notes: 1. All dimensions shown are in millimeters (mm) unless otherwise noted. 2. Dimensioning and Tolerancing per ANSI Y14.5M-1994. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 29 Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • August 12, 2021 Si 514 9. PCB Land Pattern: 5 x 7 mm, 6-pin Figure 10 illustrates the 5 x 7 mm, 6-pin PCB land pattern for the Si514. Table 17 lists the values for the dimensions shown in the illustration. Figure 10. Si514 PCB Land Pattern Table 17. PCB Land Pattern Dimensions (mm) Dimension C1 E X1 Y1 (mm) 4.20 2.54 1.55 1.95 Notes: General 1. 2. 3. 4. All dimensions shown are in millimeters (mm) unless otherwise noted. Dimensioning and Tolerancing is per the ANSI Y14.5M-1994 specification. This Land Pattern Design is based on the IPC-7351 guidelines. All dimensions shown are at Maximum Material Condition (MMC). Least Material Condition (LMC) is calculated based on a Fabrication Allowance of 0.05 mm. Solder Mask Design 5. All metal pads are to be non-solder mask defined (NSMD). Clearance between the solder mask and the metal pad is to be 60 µm minimum, all the way around the pad. Stencil Design 6. A stainless steel, laser-cut and electro-polished stencil with trapezoidal walls should be used to assure good solder paste release. 7. The stencil thickness should be 0.125 mm (5 mils). 8. The ratio of stencil aperture to land pad size should be 1:1. Card Assembly 9. A No-Clean, Type-3 solder paste is recommended. 10. The recommended card reflow profile is per the JEDEC/IPC J-STD-020 specification for Small Body Components. 30 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • August 12, 2021 Si514 10. Package Outline Diagram: 3.2 x 5.0 mm, 6-pin Figure illustrates the 3.2 x 5 mm package details for the Si514. Table 18 lists the values for the dimensions shown in the illustration. Figure 11. Si514 Outline Diagram Table 18. Package Diagram Dimensions (mm) Dimension A b c D D1 e E E1 H L L1 p R aaa bbb ccc ddd eee Min 1.06 0.54 0.35 2.55 4.35 0.45 0.80 0.05 1.17 Nom 1.17 0.64 0.45 3.20 BSC 2.60 1.27 BSC 5.00 BSC 4.40 0.55 0.90 0.10 1.27 0.32 REF 0.15 0.15 0.10 0.10 0.05 Max 1.33 0.74 0.55 2.65 4.45 0.65 1.00 0.15 1.37 Notes: 1. All dimensions shown are in millimeters (mm) unless otherwise noted. 2. Dimensioning and Tolerancing per ANSI Y14.5M-1994. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 31 Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • August 12, 2021 Si 514 11. PCB Land Pattern: 3.2 x 5.0 mm, 6-pin Figure 12 illustrates the 3.2 x 5.0 mm PCB land pattern for the Si514. Table 19 lists the values for the dimensions shown in the illustration.   Figure 12. Si514 Recommended PCB Land Pattern Table 19. PCB Land Pattern Dimensions (mm) Dimension (mm) C1 2.60 E 1.27 X1 0.80 Y1 1.70 Notes: General 1. 2. 3. 4. All dimensions shown are in millimeters (mm) unless otherwise noted. Dimensioning and Tolerancing is per the ANSI Y14.5M-1994 specification. This Land Pattern Design is based on the IPC-7351 guidelines. All dimensions shown are at Maximum Material Condition (MMC). Least Material Condition (LMC) is calculated based on a Fabrication Allowance of 0.05 mm. Solder Mask Design 5. All metal pads are to be non-solder mask defined (NSMD). Clearance between the solder mask and the metal pad is to be 60 µm minimum, all the way around the pad. Stencil Design 6. A stainless steel, laser-cut and electro-polished stencil with trapezoidal walls should be used to assure good solder paste release. 7. The stencil thickness should be 0.125 mm (5 mils). 8. The ratio of stencil aperture to land pad size should be 1:1. Card Assembly 9. A No-Clean, Type-3 solder paste is recommended. 10. The recommended card reflow profile is per the JEDEC/IPC J-STD-020 specification for Small Body Components. 32 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • August 12, 2021 Si514 12. Package Outline Diagram: 2.5 x 3.2 mm, 6-pin Figure 13 illustrates the package details for the 2.5 x 3.2 mm Si514. Table 20 lists the values for the dimensions shown in the illustration. Figure 13. Si514 Outline Diagram Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 33 Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • August 12, 2021 Si 514 Table 20. Package Diagram Dimensions (mm) Dimension A A1 A2 W D e E M L D1 E1 SE aaa bbb ddd Min — Nom — 0.26 REF 0.7 REF Max 1.1 0.65 0.7 0.75 0.45 3.20 BSC 1.25 BSC 2.50 BSC 0.30 BSC 0.5 2.5 BSC 1.65 BSC 0.825 BSC 0.1 0.2 0.08 0.55 Notes: 1. All dimensions shown are in millimeters (mm) unless otherwise noted. 2. Dimensioning and Tolerancing per ANSI Y14.5M-1994. 34 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • August 12, 2021 Si514 13. PCB Land Pattern: 2.5 x 3.2 mm, 6-pin Figure 14 illustrates the 2.5 x 3.2 mm PCB land pattern for the Si514. Table 21 lists the values for the dimensions shown in the illustration. Figure 14. Si514 Recommended PCB Land Pattern Table 21. PCB Land Pattern Dimensions (mm) Dimension C1 (mm) 1.9 E 2.50 X1 0.70 Y1 1.05 Notes: General 3. All dimensions shown are at Maximum Material Condition (MMC). Least Material Condition (LMC) is calculated based on a Fabrication Allowance of 0.05 mm. 4. This Land Pattern Design is based on the IPC-7351 guidelines. Solder Mask Design 5. All metal pads are to be non-solder mask defined (NSMD). Clearance between the solder mask and the metal pad is to be 60 µm minimum, all the way around the pad. Stencil Design 6. A stainless steel, laser-cut and electro-polished stencil with trapezoidal walls should be used to assure good solder paste release. 7. The stencil thickness should be 0.125 mm (5 mils). 8. The ratio of stencil aperture to land pad size should be 1:1 for all perimeter pins. Card Assembly 9. A No-Clean, Type-3 solder paste is recommended. 10. The recommended card reflow profile is per the JEDEC/IPC J-STD-020 specification for Small Body Components. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 35 Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • August 12, 2021 Si 514 14. Top Marking Use the utility located at: www.skyworksinc.com/en/application-pages/timing-lookup-customize to cross-reference the marked code to a specific device configuration. 14.1. Si514 Top Marking 4 C CC CC T TTT TT Y Y WW 14.2. Top Marking Explanation Mark Method: Laser Line 1 Marking: 4 = Si514 CCCCC = Mark Code 4CCCCC Line 2 Marking: TTTTTT = Assembly Manufacturing Code TTTTTT Line 3 Marking: Pin 1 indicator. Circle with 0.5 mm diameter; left-justified YY = Year. WW = Work week. Characters correspond to the year and work week of package assembly. YYWW 36 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • August 12, 2021 Si514 REVISION HISTORY Revision 1.2 June, 2018  Changed “Trays” to “Coil Tape” in Ordering Guide. Revision 1.1 December, 2017  Added new 2.5 x 3.2 mm package. Revision 1.0  Updated Table 1 on page 3. Updates to supply current typical and maximum values for CMOS, LVDS, LVPECL and HCSL. frequency test condition corrected to 100 MHz. Updates to OE VIH minimum and VIL maximum values. CMOS  Updated Table 2 on page 3. Dual CMOS nominal frequency maximum added. stability footnotes clarified for 10 year aging at 40 °C. Disable time maximum values updated. Enable time parameter added. Total  Updated Table 3 on page 4. CMOS output rise / fall time typical and maximum values updated. output rise / fall time maximum value updated. LVPECL output swing maximum value updated. LVDS output common mode typical and maximum values updated. HCSL output swing maximum value updated. Duty cycle minimum and maximum values tightened to 48/52%. LVPECL/HCSL  Updated Table 5 on page 6. Phase jitter test condition and maximum value updated. noise typical values updated. Additive RMS jitter due to external power supply noise typical values updated. Footnote 3 updated limiting the VDD to 2.5/3.3V Phase      Added Tables 6, 7, 8 for LVDS, HCSL, CMOS, and Dual CMOS operations. Moved Absolute Maximum Ratings table. Added note to Figure 8 clarifying CMOS and Dual CMOS maximum frequency. Updated Figure 9 outline diagram to correct pinout. Updated “14. Top Marking” section and moved to page 36. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 37 Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • August 12, 2021
514CCC001460AAGR
物料型号:Si514

器件简介: Si514是一款由Skyworks公司生产的全频率I2C可编程晶振(XO),频率范围从100 kHz到250 MHz,具备0.026 ppb的频率调谐分辨率。它使用了先进的PLL技术,通过简单的I2C命令即可生成所需频率。Si514适用于多种应用,包括全数字PLL、DAC+VCXO替换、SONET/SDH/OTN、3G-SDI/HD-SDI/SDI等。

引脚分配: - SDA:I2C串行数据。 - SCL:I2C串行时钟。 - CLK+:时钟输出。 - CLK-:LVPECL、LVDS、HCSL和双CMOS格式的互补时钟输出;对于单端CMOS格式,CLK-不连接。 - VDD:电源电压。

参数特性: - 可编程频率范围:100 kHz至250 MHz。 - 频率调谐分辨率:0.026 ppb。 - 低抖动操作。 - 工作温度范围:-40至85°C。 - 电源电压选项:3.3V、2.5V或1.8V。 - 差分(LVPECL、LVDS、HCSL)或CMOS输出选项。

功能详解: Si514使用了一个单一的集成晶体和Skyworks的专有DSPLL合成器,通过I2C命令在频率范围内生成任何频率。它提供了优越的电源噪声抑制,简化了在嘈杂环境中低抖动时钟的生成。晶体的ESR和DLD在生产测试中被单独测试,以保证性能并提高可靠性。

应用信息: Si514适用于数据通信、工业自动化、FPGA/ASIC时钟生成、FPGA同步等领域。

封装信息: Si514提供2.5x3.2 mm、3.2x5.0 mm和5x7 mm的封装选项,符合行业标准。
514CCC001460AAGR 价格&库存

很抱歉,暂时无法提供与“514CCC001460AAGR”相匹配的价格&库存,您可以联系我们找货

免费人工找货