0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
SI5040-D-GM

SI5040-D-GM

  • 厂商:

    SILABS(芯科科技)

  • 封装:

    -

  • 描述:

    IC TXRX XFP 10GBPS 32LGA

  • 数据手册
  • 价格&库存
SI5040-D-GM 数据手册
Si5040 1 0 G b p s X F P T RAN SC EIVER W I T H J ITTE R AT T E N U ATO R Features Complete, high-performance, low-power, 10 Gbps XFP transceiver featuring independent CDRs, DSPLL®-based jitter-attenuating CMUs, and data retimers in both transmit and receive directions. N ot fo R r N ec o ew m m D e es nd ig e ns d Si5100 Pin Assignments Applications GND SS SD 29 V DD 30 28 27 26 25 1 24 RX_LOL 2 23 GND RX_LOS 3 22 TD+ VDDIO 4 21 TD– GND 5 20 GND RXDIN– 6 19 RD+ RXDIN+ 7 18 RD– GND 8 17 GND GND PAD GND PAD GND PAD 9 10 11 12 13 14 15 16 VDD INTERRUPT GND PAD REFCLK- The Si5040 is a complete, low-power, high-performance XFP transceiver suitable for multiple XFP module types, from short-reach datacom to long-reach telecom applications. The Si5040 integrates a rate-agile, programmable-bandwidth, jitterattenuating CMU in the transmit direction, which significantly attenuates jitter present at the XFI interface and on the applied reference clock, removing the need for an external jitter cleanup circuit. The device supports referenceless operation or operation with a synchronous or asynchronous reference clock. The device can be completely configured through a serial microcontroller interface. The Si5040 is compliant with all XFP requirements in both datacom and telecom applications. The Si5040 is packaged in a 5x5 mm LGA package and dissipates 575 mW (typ). 31 GND V DD Description 32 TX DO UT– Jitter-attenuation and signal regeneration of 10 Gbps serial signal on line cards REFCLK+  XFP telecom modules XFP datacom modules Optical test equipment GND    Si5040 (Transparent Top View) TX DO UT+  See page 103. NC   Ordering Information: V DD  Transmitter jitter generation 2.5 mUIrms (typical) Automatic slicing level adjustment with optional programmable override Programmable sample phase adjustment Line loopback, XFI loopback, pattern generation, and pattern check test capabilities 1.8/3.3 V or single 1.8 V supply 575 mW (typ) power dissipation 5x5 mm LGA package Serial microcontroller interface control NC  DSPLL-based, jitter-attenuating CMUs  in both transmit and receive directions Frequency-agile jitter filtering from 9.8 to  11.35 Gbps (continuous)  Compliant to XFP specifications and jitter specifications for telecom (SONET/SDH, OTU-2) and datacom  (10 GbE/10 GbE+FEC and 10 GFC/10 GFC+FEC) applications Supports referenceless operation  Integrated limiting amplifier provides  better than 8 mV receiver sensitivity  User-programmable receiver loss-of signal (LOS) detector SPSEL  SCK Functional Block Diagram RX_LOS RXDIN Interrupt Program mable Equalizer RX_LOL CDR LA Control FIFO CML RD DSPLLTM Jitter Attenuator XFI Loopback Serial Interface D Clk Line Loopback RefCLK (optional) DSPLLTM Jitter Attenuator Serial Port Clk TXDOUT CML FIFO D CDR Equalizer TD Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 N ot fo R r N ec o ew m m D e es nd ig e ns d Si5040 2 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 TA B L E O F C O N T E N T S Section Page N ot fo R r N ec o ew m m D e es nd ig e ns d 1. Si5040 Detailed Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 2. Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 3. Typical Application Schematic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 4. Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 5. Receiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 5.1. Receive Equalizer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 5.2. Limiting Amplifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 5.3. Receive Amplitude Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 5.4. Receiver Loss of Signal Alarm (LOS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 5.5. Receiver Slice Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 5.6. Clock and Data Recovery (CDR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 5.7. Reference Clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24 5.8. Receiver Loss of Lock (LOL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 5.9. Receiver Phase Adjust . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 5.10. Receive Clock Multiplier Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 5.11. Recommended Pre-Emphasis on the RD Signal . . . . . . . . . . . . . . . . . . . . . . . . . . 28 6. Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 6.1. Transmitter Loss-of-Signal Alarm (LOS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 6.2. Transmit Equalizer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 6.3. Clock and Data Recovery (CDR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 6.4. Transmitter Loss of Lock (LOL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 6.5. Transmitter Phase Adjust . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 6.6. Transmit Clock Multiplier Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 6.7. Timing Modes Of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 7. Loopback Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 7.1. XFI Loopback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 7.2. Lineside Loopback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 8. Looptime Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 9. Pattern Generation and Checking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 10. Serial Microcontroller Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 10.1. I2C Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 10.2. SPI-Like Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 11. Interrupt Functionality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 12. Programmable Power Down Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 13. Si5040 Register Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 14. Pin Descriptions: Si5040 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100 15. Ordering Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103 16. Package Outline: Si5040 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104 17. Recommended VDD Power Supply Filtering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105 Document Change List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106 Contact Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .108 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 3 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 4 TXDOUT- TXDOUT+ RXDIN+ RXDIN- CML RX CDR TX FIFO LTR REFCLK INTERRUPT Interrupt Control Line LB Data XFI LB Data TM DLOS SQM TX LOS SCK SD SS SPISEL TXLOL refLOS REFCLK Equalizer LVPECL CML Line LB Data RX Pattern Gen. Tx Phase Adjust Freq Offset Measurement TX CDR SQM Measurement AND Serial Port Communication Digital LOS Clock XFI Recovered Line LB Clk rxRefclkEn(x) LTR RX FIFO RX Pattern Check DSPLL Jitter Attenuator RX CMU Line Recovered Data Digital LOS XFI Recovered Data DSPLLTM Jitter Attenuator TX CMU Line Recovered Clock XFI LB Clk Freq Offset Measurement RXLOL RX_LOL SQM Measurement DLOS SQM Rx Phase Adjust RX LOS XFI LB Clk ALOS TX Pattern Check Analog LOS SLICE_ADJ LA TX Pattern Gen. XFI LB Data RX EQ HF Boost Programmable Equalizer RX EQ Gain Peak Detector RX_LOS N ot fo R r N ec o ew m m D e es nd ig e ns d TD+ TD- REFCLK- REFCLK+ (optional) RD- RD+ Si5040 1. Si5040 Detailed Block Diagram Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 2. Electrical Specifications Table 1. Recommended Operating Conditions Parameter Symbol Min1 Typ Max1 Unit TA –40 25 95 C Supply Voltage VDD2 1.62 1.80 1.89 V LVTTL I/O Supply Voltage VDDIO 1.62 — 3.63 V N ot fo R r N ec o ew m m D e es nd ig e ns d Ambient Temperature Test Condition Notes: 1. All minimum and maximum specifications are guaranteed and apply across the recommended operating conditions. Typical values apply at nominal supply voltages and an operating temperature of 25 C unless otherwise stated. 2. Maximum power ramp-up time to reach VDD > 1.62 V should be less than 50 ms. Any ramp-up time slower than 50 ms will require a software reset to ensure proper calibration of all internal circuits. V SIGNAL + Differential VICM , VOCM SIGNAL – I/Os VISE , V OSE Single-Ended Peak-to-Peak Voltage (SIGNAL +) – (SIGNAL –) Differential Peak-to-Peak Voltage VID ,VOD (V ID = 2VISE) Differential Voltage Swing t Figure 1. Voltage Measurement 80% All Differential IOs 20% tF tR Figure 2. Rise/Fall Time Measurement Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 5 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Table 2. DC Characteristics (VDD = 1.8 V +5%/–10%, TA = –40 to 95 °C) Parameter Supply Current Test Condition Min Typ Max Unit — — 370 mA VDD = 1.89 V1 VDD = 1.8 V1 — — — 575 700 — mW IDD PD N ot fo R r N ec o ew m m D e es nd ig e ns d Power Dissipation Symbol Differential Input Voltage Swing (RXDIN) (at BER 10–12) VID Figure 1 with Receive Equalizer bypassed 8 — 1000 mVPPD Common Mode Output Voltage (TXDOUT) VOCM Figure 1 — 1.3 – VOD/2 — V 800 700 600 500 400 300 200 100 — — — — — — — — — — — — — — — — 250 — 2400 mVPPD — 100 —  Differential Output Voltage Swing (TXDOUT), Differential Peak-to-Peak OutLevel[2:0] = 111 110 101 100 011 010 001 000 VOD Figure 1 RL = 100  LVPECL Input Voltage Swing, Differential Peak-to-Peak (REFCLK)2 VID Figure 1 Differential Input Impedance (TD, REFCLK, RXDIN) RIN LVTTL Input Voltage Low VIL VDDIO = 3.3 V3 –0.3 — 0.8 V LVTTL Input Voltage High VIH VDDIO = 3.3 V3 2.0 — VDDIO + 0.3 V LVTTL Input Impedance RIN 10 — — k LVTTL Output Voltage Low (IOUT = 2 mA) VOL VDDIO = 3.3 V3 — — 0.4 V LVTTL Output Voltage High (IOUT = 2 mA) VOH VDDIO = 3.3 V3 2.4 — — V — 100 —  Termination Mismatch (RD) — — 5 % Termination Mismatch (TD) — — 5 % Differential Output Impedance (RD, TXDOUT) ROUT mVPPD Notes: 1. TX CMU Mode 0. 2. REFCLK must be ac-coupled. For CMU Mode 1 or TX LTR operation, the minimum input swing should be 650 mVPPD. 3. VDDIO = 1.8 V, not characterized. 6 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Table 2. DC Characteristics (Continued) (VDD = 1.8 V +5%/–10%, TA = –40 to 95 °C) Parameter Symbol Test Condition Min Typ Max Unit V I2C Bus Lines (SD, SCK) VILI2C — — 0.3 x VDDIO Input Voltage High VIHI2C 0.7 x VDDIO — — N ot fo R r N ec o ew m m D e es nd ig e ns d Input Voltage Low Input Current Hysteresis of Schmitt trigger inputs Output Voltage Low III2C VIN = 0.1 x VDDIO to 0.9 x VDDIO –10 — 10 VHYSI2C VDDIO = 1.8 V 0.1 x VDD — — VDDIO = 3.3 V 0.05 x VDD — — VDDIO = 1.8 V IO = 3 mA — — 0.2 x VDD VDDIO = 3.3 V IO = 3 mA — — 0.4 VOLI2C V µA V V V V Notes: 1. TX CMU Mode 0. 2. REFCLK must be ac-coupled. For CMU Mode 1 or TX LTR operation, the minimum input swing should be 650 mVPPD. 3. VDDIO = 1.8 V, not characterized. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 7 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Table 3. AC Characteristics–RXDIN (Receiver Input) (VDD = 1.8 V +5/–10%, TA = –40 to 95 C) Parameter Symbol Test Condition Min Typ Max Unit 9.80 9.95 11.35 Gbps < 2 GHz 5 GHz 10 GHz 15 10 5 — — — — — — dB dB dB ALOS Range Analog Mode 10 — 400 mVPPD ALOS Step Size Analog Mode — 1 — mVPPD ALOS Relative Accuracy Analog Mode 1 — — mV DLOS Range Consecutive Digits Mode 0.5 — 100 µs DLOS Accuracy Consecutive Digits Mode 0.5 — — µs Analog Mode 0 — 6 dB Slice Voltage Range mode = absolute or proportional –240 — 240 mVD Slice Voltage Error Max error from the programmed absolute slice voltage ±20 % RX Path Data Rate N ot fo R r N ec o ew m m D e es nd ig e ns d Input Return Loss (RXDIN) ALOS Hysteresis (Programmable 0.4 dB steps) Sample Phase Range Jitter Tolerance OC-192 BER = 10–12 JTOL(PP) –12 — 12 ps f = 2.0 kHz 15 30 — UIPP f = 20 kHz 1.5 3.0 — UIPP f = 400 kHz 1.5 3.0 — UIPP f = 4 MHz 0.4 — — UIPP f = 80 MHz 0.4 — — UIPP Register 86, bit 6:3 = 8 decimal Register 68, bit 3:0 = 2 decimal Register 67, bit 6:2 = 17 decimal — — — — 50 50 ms ms Acquisition Time (Default mode) REFCLK Referenceless TAQ Frequency Difference at which Receive PLL Goes Out of Lock LOL 800 — — ppm Frequency Difference at which Receive PLL Goes into Lock LOCK — — 200 ppm 8 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Table 4. AC Characteristics—RD (Receiver Output) (VDD = 1.8 V +5/–10%, TA = –40 to 95 C) Parameter Symbol Test Condition Common Mode AC Output Voltage Typ Max Unit — — 15 mVRMS tR,tF Figure 2 24 — — ps SDD22 0.05–0.1 GHz 20 — — dB 0.1–5.5 GHz 8 — — dB 5.5–12 GHz * — — dB SCC22 0.1–15 GHz 3 — — dB Deterministic Jitter DJ — — 0.09 UIPP Total Jitter TJ >4 MHz. See Appendix E1 in the XFP specification. — — 0.17 UIPP Eye Mask X1 See Figure 3. — 0.08 — UI Eye Mask X2 See Figure 3. — 0.33 — UI Eye Mask Y1 See Figure 3. 190 — — mV Eye Mask Y2 See Figure 3. — — 385 mV Jitter Transfer Bandwidth (Programmable) cmuBandwidth[3:0] (Register 6, bits 7:4) 0100 JBW 9.95 Gbps N ot fo R r N ec o ew m m D e es nd ig e ns d Output Rise and Fall Times (RD) Min Differential Output Return Loss Common Mode Output Return Loss kHz — 380 760 *Note: Differential return loss given by equation SDD22 (dB) = 8 – 20.66 Log10(f/5.5), with fin GHz. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 9 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Y2 Y1 N ot fo R r N ec o ew m m D e es nd ig e ns d Absolute Amplitude Si5040 0 –Y1 –Y2 0.0 X1 X2 1–X2 1–X1 Normalized Time (UI) 1.0 Figure 3. Receiver Differential Output Mask (RD) 10 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Table 5. AC Characteristics—TXDOUT (Transmitter Output) (VDD = 1.8 V +5/–10%, TA = –40 to 95 C) Parameter Output Rise + Fall Times Symbol Test Condition Min Typ Max Unit tR, tF Figure 2 20 25 30 ps 400 kHz–10 GHz 10 GHz–16 GHz 6 4 — — — — dB dB N ot fo R r N ec o ew m m D e es nd ig e ns d Output Return Loss Random RMS Jitter Generation, TXDOUT1 JGEN(rms) OC-192, CMU mode 0 — 2.8 4.6 mUIRMS Total Peak-to-Peak Jitter Generation, TXDOUT1 JGEN(PP) OC-192, CMU mode 0 — 36 60 mUIPP — 180 220 Hz — 1.37 1.76 kHz 0010 — Not supported 0100 — 0101 — Not supported kHz 0110 — Not supported kHz Jitter Transfer Bandwidth (Programmable) CMU bandwidth [3:0] (Register 134, bits 7:4) 0000 0001 JBW Jitter Transfer Peaking Acquisition Time REFCLK Referenceless 9.95 Gbps < 120 kHz 380 — 760 kHz kHz 0.03 dB TAQ — — — — 50 61 ms ms 618.75 154.687 622 155 709.4 177.35 MHz Input Reference Clock Frequency2 RCFREQ Input Reference Clock Duty Cycle RCDUTY 40 — 60 % Input Reference Clock Frequency Tolerance RCTOL –100 — 100 ppm ref clk /16 mode ref clk /64 mode Notes: 1. PRBS31 or SONET framed PRBS31 data. The integrated CMU filters out SONET framing effects. 2. Input reference clock frequency can be either Baud rate/16 or Baud rate/64 ±100 ppm. The typical and maximum numbers specified here correspond to /16 or /64 of the typical and maximum data rate that the device supports. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 11 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Table 6. AC Characteristics–TD (Transmitter Input) Parameter Symbol Test Condition Min Typ Max Unit 9.80 9.95 11.35 Gbps 0.05–0.1 GHz 20 — — dB 0.1–5.5 GHz 8 — — dB 5.5–12 GHz See Note 1 — — dB 0.1–15 GHz 3 — — dB — 0.45 UIPP — 0.65 UIPP — See Figure 4 — UIPP N ot fo R r N ec o ew m m D e es nd ig e ns d TX Path Data Rate Differential Input Return Loss Common Mode Input Return Loss (TD) SDD11 SCC11 Total Non-DDJ2 Total Jitter TJ Sinusoidal Jitter Tolerance3 SJ Eye Mask (See Figure 5) X1 — — 0.325 UI Eye Mask (See Figure 5) Y1 50 — — mV Eye Mask (See Figure 5) Y2 — — 525 mV Notes: 1. Return loss is given by the following equation: SDD11(dB) = 8–20.66Log10(f/5.5), with f in GHz. 2. Total jitter less ISI. 3. The jitter tolerance given in Figure 5 is in addition to the random and deterministic jitter given in this table. Table 7. CMU Timing Modes Mode Description Typical Jitter Gen. Recommended CMU Jitter Transfer Bandwidth Setting 0 No Reference Clock or Asynchronous Reference Clock1,2 3.5 mUIrms 380 kHz 1 Clean, synchronous3 2.5 mUIrms 380 kHz 2 Clean, asynchronous1,3 2.5 mUIrms 1.37 kHz Notes: 1. Reference clock with frequency equal to Baud rate /64 ±100 ppm and phase noise as defined in XFP Specification 3.1, Section 3.9. 2. Since the default bandwidth for this mode is 100 kHz, Register 134 [7:4] should be written to a “4” to set the bandwidth to 380 kHz. 3. Clean reference clock with frequency equal to exactly Baud rate /64 and phase noise as defined in XFP Specification 3.1, Section 3.9.1. REFCLK input amplitude >650 mVppd. 12 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Si5040 TD Jitter Tolerance (Typ) 100 N ot fo R r N ec o ew m m D e es nd ig e ns d XFI Specification Sinusoidal Jitter Tolerance (UIpp) 10 1 0.1 0.01 1 10 100 1000 10000 100000 1000000 10000000 100000000 Frequency (Hz) Absolute Amplitude Figure 4. XFI Sinusoidal Jitter Tolerance (UIPP) Y2 Y1 0 –Y1 –Y2 0.0 X1 1–X1 1.0 Normalized Time (UI) Figure 5. Transmitter Differential Input Mask (TD) Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 13 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Table 8. AC Characteristics—I2C Bus Lines (SD, SCK) (VDD = 1.8 V +5/–10%, TA = –40 to 95 C) Parameter Pin Capacitance Symbol Test Condition CII2C Min Typ Max Unit — — 10 pF N ot fo R r N ec o ew m m D e es nd ig e ns d Table 9. Switching Characteristics—Serial Microcontroller Interface2 VDD = 1.8 V +5/–10%, VDDIO = 3.3 V ±10%, TA = –40 to 95 °C, CL = 20 pF Parameter Symbol Test Conditions Min Typ Max Unit 100 — — ns Cycle Time SCK tc Rise Time, SCK tr 20–80% — — 25 ns Fall Time, SCK tf 20–80% — — 25 ns Low Time, SCK tlsc 20–20% 30 — — ns High Time, SCK thsc 80–80% 30 — — ns Delay Time, SCK Fall to SD Active td1 — — 25 ns td2 — — 25 ns td3 — — 25 ns Setup Time, SS to SCK Fall tsu1 25 — — ns Hold Time, SS to SCK Rise th1 20 — — ns Setup Time, SD to SCK Rise tsu2 25 — — ns Hold Time, SD to SCK Rise th2 20 — — ns Delay Time between Slave Selects tcs 25 — — ns Delay Time, SCK Fall to SD Transition Delay Time, SS Rise to SD Tri-state 1 Notes: 1. SD is designed to be tristated by the release of the chip select signal (the rising edge of the SS). 2. All timing is referenced to the 50% level of the waveform unless otherwise noted. Input test levels are VIH = VDD –0.4 V, VIL = 0.4 V 14 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 tc tr tf SCK thsc tlsc tsu1 N ot fo R r N ec o ew m m D e es nd ig e ns d th1 SS tcs tsu2 th2 SD td1 td3 td2 SD Figure 6. Serial Microcontroller Interface Timing Diagram SS SCK SD 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 2 1 0 Figure 7. SPI-Like Interface Write/Set Address Command SS SCK SD 7 6 5 4 3 2 Read Command 1 0 7 6 5 4 3 Read Data Figure 8. SPI-Like Interface Read Command Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 15 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Table 10. Thermal Characteristics Parameter Thermal Resistance Junction to Ambient Symbol Test Condition Value Unit JA Still Air 50 C/W N ot fo R r N ec o ew m m D e es nd ig e ns d Table 11. Absolute Maximum Ratings* Parameter DC Supply Voltage LVTTL Supply Voltage Differential Input Voltages Symbol Value Unit VDD –0.5 to 1.98 V VDDIO –0.5 to 3.8 V VDIF –0.3 to (VDD+ 0.3) V ±50 mA Maximum Current any Output PIN Operating Junction Temperature TJCT –55 to 150 C Storage Temperature Range TSTG –55 to 150 C High-speed pins 2 kV All except high-speed pins 2 kV ESD HBM Tolerance (100 pf, 1.5 k) *Note: Permanent device damage can occur if the absolute maximum ratings are exceeded. Restrict functional operation to the conditions specified in the operational sections of this data sheet. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. 16 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 3. Typical Application Schematic TXDOUT- TXDOUT+ .1 UF .1 UF VDD_1P8 N ot fo R r N ec o ew m m D e es nd ig e ns d VDD_1P8 VDDIO SD25 SS26 VDD327 GND728 TD-21 U? 16INTRPT 15VDD1 14REFCLK- 13REFCLK+ 12VDD2 .1 UF 11NC RD-18 9SPSEL RD+19 7RXDIN+ 8GND3 TD+ TD- GND520 6RXDIN- 10NC RXDIN+ .1 UF .1 UF TD+22 SI5040 5GND2 .1 UF .1 UF SCK24 GND423 3RX_LOS 4VDDIO RXDIN- TXDOUT-29 GND831 2RX_LOL TXDOUT+30 VDD432 C? 1GND1 .1 UF VDD_1P8 .01 UF .01 UF .1 UF RD- GND617 .1 UF RD+ .01 UF VDD_1P8 REFCLK+ .01 UF .01 UF .01 UF VDD_1P8 REFCLK- Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 17 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 4. Functional Description The Si5040 XFP transceiver is a single-chip, bidirectional signal conditioner for use in XFP modules as defined by the XFP multi-source agreement. The Si5040 includes independent clock and data recovery units (CDRs) and frequency-agile, jitter-attenuating clock multiplier units (CMUs) in both receive and transmit directions. The receive path includes a limiting amplifier and a programmable equalizer for direct connection to an optical receiver transimpedance amplifier. The transmit path includes an equalizer for direct connection to the XFI channel. N ot fo R r N ec o ew m m D e es nd ig e ns d The device provides data-agnostic operation over a continuous range of data rates from 9.8 to 11.35 Gbps. Typical data rates and associated applications include the following:  9.8304 Gbps: Common Public Radio Interface (CPRI)  9.95 Gbps: SONET OC-192, SDH STM-64, 10 Gbps Ethernet WAN PHY  10.31 Gbps: 10 Gbps Ethernet LAN PHY  10.52 Gbps: 10 Gbps FibreChannel (10 GFC)  10.70 Gbps: OTN OTU-2 (G.709)  11.09 Gbps: 10 Gbps Ethernet LAN PHY with 255/237 FEC coding  11.32 Gbps: 10 Gbps FibreChannel with 255/237 FEC coding Serial control and status monitoring is supported with either an SPI-like or I2C serial interface. 18 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 5. Receiver The Si5040 receiver includes a programmable equalizer, a high-sensitivity limiting amplifier, clock and data recovery unit (CDR), and a FIFO/retimer function. 5.1. Receive Equalizer Normalized Output Amplitude (dB) N ot fo R r N ec o ew m m D e es nd ig e ns d The RX equalizer is a programmable equalizer designed to boost the high-frequency components while attenuating the low-frequency components. Figure 9 illustrates a typical frequency response of the RX equalizer when its capacitor setting (or high-frequency boost, RxEqHFBoost at Register 85, Bit [7:5]) is set to the maximum value and its resistor setting (or low-frequency gain/attenuation, RxEqGain at Register 84, Bit [7:5]) is changed to achieve different low-frequency attenuations. 2.00 1.00 0.00 -1.00 -2.00 -3.00 -4.00 -5.00 -6.00 -7.00 -8.00 -9.00 -10.00 -11.00 -12.00 -13.00 -14.00 -15.00 -16.00 -17.00 -18.00 -19.00 -20.00 -21.00 -22.00 -23.00 -24.00 -25.00 1.00E+06 1.00E+07 1.00E+08 1.00E+09 1.00E+10 1.00E+11 Frequency (Hz) Figure 9. Typical RX Equalizer Frequency Response To optimize the equalizer settings for a given application, the following procedure is recommended:  Set RxEqHFBoost at Register 85, Bit [7:5] to 7 (Default = 4), and adjust RxEqGain at Register 84, Bit [7:5] (Default = 5), to achieve the best performance.  Further adjust RxEqHFBoost to increase the performance further. Note that setting RxEqGain to 0 dB bypasses the equalizer. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 19 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 5.2. Limiting Amplifier The Si5040 incorporates a high-sensitivity differential limiting amplifier with sufficient gain to allow direct connection to a transimpedance amplifier. The amplifier has a guaranteed sensitivity of 8 mVppd. 5.3. Receive Amplitude Monitor N ot fo R r N ec o ew m m D e es nd ig e ns d The Si5040 limiting amplifier includes circuitry that monitors the amplitude of the receiver differential input signal (RXDIN). The amplitude value can be read from the Peakdet register (Register 16). The receiver signal amplitude monitoring circuit is also used in the generation of the loss-of-signal alarm (LOS). 5.4. Receiver Loss of Signal Alarm (LOS) The Si5040 receiver generates a loss-of-signal alarm when the input signal fails to meet the selected programmable condition for loss of signal. The programmable LOS mode is controlled in the RxlosCtrl register (Register 10). The programmable modes are Analog Loss Of Signal (ALOS), Digital Loss of Signal (DLOS), and Signal Quality Monitor (SQM). As shown in Figure 15, one or more of these alarm signals is logically combined into the Receiver Loss of Signal (RX_LOS) alarm pin (Pin 3). The state of the RX_LOS alarm pin will also be reflected in the LOS bit in the RxAlarmStatus register (Register 9). LOS may also be configured to generate an interrupt. The status of the LOS interrupt bit may be read in the RxintStatus register (Register 5). The status of the various LOS modes is stored in the losStatus register (Register 11). An ALOS alarm occurs when the peak-to-peak signal amplitude on the RXDIN input is below the threshold value set in the aLosThresh register (Register 12). The level may be set from 10 to 400 mV in 1 mV increments. The amount of hysteresis applied to ALOS is set in the aLosThresh2 register (Register 13) up to a maximum of “aLoSThresh+” 6 dB. The default value is “aLoSThresh+” 3 dB. The analog LOS function is enabled by setting bit 0 in the RxLosCtrl register (Register 10). Note that the peak-to-peak detector and ALOS detection are designed to work with pseudo-random dc-balanced data band limited to (dLosAssertThresh *5 +2) *1024 No Yes Set dLos Figure 10. Algorithm to Set dLOS 20 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 N ot fo R r N ec o ew m m D e es nd ig e ns d Si5040 >0 transition in a 1024-bit field No Yes Increment Reset Counter Count Is Count > dLosClearThresh *16 +1 No Yes Clear dLos Figure 11. Algorithm to Clear dLOS The receiver may be programmed to perform any of the following consequent actions upon declaring RX_LOS: 1. Lock the receiver to the applied reference clock (lock to reference): ltrOnLOS bit in Register 7. 2. Assert receiver loss of lock (LOL): lolOnLOS bit in Register 7. 3. Disable (squelch) the receive data output (RD): SquelchOnRxLOS bit in Register 28. 4. Generate a clock pattern at the receive data output (RD): clkOnLOS bit in Register 28. For different combinations of ltrOnLOS and lolOnLOS settings in Register 7, the device may behave differently in the CDR lock acquisition process. Refer to Figure 12 and Figure 13 for more details on CDR and VCO behaviors upon declaring LOS. ltrOnLOS = 0, lolOnLOS = 0, and VCOCAL[1:0] = 10 binary by default. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 21 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 LOS=1? Y Y LOLonLOS =0 and ltrOnLos=0? (Default) LOLonLOS =1 and ltrOnLos =0? LOLonLOS = 1 and ltrOnLos = 1? LOLonLOS = 0 and ltrOnLos = 1? N ot fo R r N ec o ew m m D e es nd ig e ns d Y Y CDR continuously tries to lock to incoming data, and the VCO frequency does not get re-centered prior to the lock acquisition process. Next Figure VCOCAL[1:0] = 10 (Default)? VCOCAL[1:0] = 00? VCOCAL[1:0] = 01? Y Y Y VCOCAL[1:0] = 11? Y Is refClk present? N The internal VCO pull range will be automatically re-centered to the reference clock frequency to start the CDR lock acquisition process. Y Y Is refClk present? N VCO stays at the center of its frequency range awaiting for refClk. The entire VCO frequency range will be swiped to start the CDR lock acquisition process. Invalid mode! LOL will stay on. Figure 12. CDR and VCO Behaviors Upon Declaring LOS (1 of 2) From Previous Figure LOLonLOS = 0 and ltrOnLos = 1? LOLonLOS =1 and ltrOnLos =1? Y Y Ltr (bit 1 in Register 7)= 1? Y N Y Is refClk present? N VCO stays at the center of its frequency range awaiting for refClk. Since ltr has been set to 1 prior to the assertion of LOS, CMU maintains lock to the reference and the CDR lock acquisition depends on CDRLTDATA control in Register 7. CMU locks to the reference clock until LOS is clear. Note that LOL will be off during this period. VCOCAL[1:0] = X0? VCOCAL[1:0] = X1? Y Y Y Is refClk present? Invalid mode! ltrOnLOS is enabled but refClk is disabled. N The internal VCO pull range will be automatically recentered to the reference clock frequency to start the CDR lock acquisition process. Note that LOL will not be cleared. VCO stays at the center of its frequency range awaiting for refClk. Figure 13. CDR and VCO Behaviors Upon Declaring LOS (2 of 2) 22 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 LOL=1? Y VCOCAL[1:0] = 01? VCOCAL[1:0] = 10 (Default)? VCOCAL[1:0] = 00? Y The internal VCO pull range will be automatically re-centered to the reference clock frequency to start the CDR lock acquisition process. Y Y N ot fo R r N ec o ew m m D e es nd ig e ns d Y VCOCAL[1:0] = 11? Is refClk present? N The entire VCO frequency range will be swiped to start the CDR lock acquisition process. Y Y Is refClk present? N VCO stays at the center of its frequency range awaiting for refClk Invalid mode! LOL will stay on. Figure 14. Receive and Transmit CDR and VCO Behaviors Upon Declaring LOL 5.5. Receiver Slice Control In order to optimize the bit error rate performance of the system, the receiver supports automatic and manual adjustment of the 0/1 decision threshold (slice control). Four slice modes can be programmed via Register 20 as detailed below:  AutoSlice Mode (sliceEn[2:0] = 001): The slice is automatically set without any control by the user. An internal estimate of the eye opening is used to automatically adjust the slice voltage. This mode can be used when there is no FEC processor as it continually adjusts the slice voltage. Registers 22/21 have no effect on this mode of operation.  Constant Duty Cycle Mode (sliceEn[2:0] = 010): This mode continually adjusts the slice voltage to maintain a user-selected duty cycle at the limiting amplifier output. The duty cycle can be set in the sliceLVL register (Registers 22 and 21). This mode can be used when there is no FEC processor, however, if the duty cycle is dynamically controlled the recommended duty cycle step size is less than or equal to 0.1%. In an actual system the duty cycle should not be set to less than 45% or greater than 55%. For the case of maximum dispersion, an optimally-set duty cycle will typically perform slightly better than Autoslice.  Proportional Mode (sliceEn[2:0] = 011):The slice offset is defined as a percentage of the peak-to-peak value of the input signal. The percent value is written in the sliceLVL register (Registers 22 and 21) as an offset from 50%. Due to drifts and temperature variations in the silicon, the slice offset values must be dynamically modified at a rate of 100 ms or faster. This mode is recommended only when a FEC processor is present to control the slice level.  Absolute Mode (sliceEn[2:0] = 100): The slice offset is defined as an absolute voltage. The offset can be set in the range of –240 to +240 mV in the sliceLVL register (Registers 22 and 21). Just as in proportional mode, the slice offset values must be dynamically modified at a rate of 100ms or faster. This mode is recommended only when a FEC processor is present to control the slice level. Autoslice and constant duty cycle are the preferred slice modes of operation for Telecom and Datacom applications. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 23 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 5.6. Clock and Data Recovery (CDR) N ot fo R r N ec o ew m m D e es nd ig e ns d The Si5040 integrates a CDR to recover the clock and data from the input signal applied to RXDIN. The CDR can be operated with or without an external reference clock. Reference or referenceless operation is programmed in the RxCalConfig register (Register 8). If a reference clock is applied to the receiver, the CDR can be forced to lock to the reference clock in the event that a loss of signal occurs. The CDR can be programmed to continue to sample the RXDIN input while the receive PLL is locked to the reference clock. These options are controlled in the RxConfig register (Register 7). 5.7. Reference Clock The Si5040 will operate with or without an external reference clock. If a reference clock is applied, the receiver uses the reference clock to center the internal VCO pull range, which, in turn, reduces the acquisition time of the CDR. If the reference clock is not applied, the entire VCO frequency range will be swept for lock acquisition. Note that since the applied reference clock is used for both the receiver and the transmitter and since the receiver may be running at a different rate than the transmitter, the user is given the option of disabling the reference clock on the receiver. The RxrefclkEn bit in the RxConfig register (Register 7) controls this function. The receiver can be locked to the reference clock under the following programmable conditions: (RxConfig, Register 7) 1. Set LTR (bit 1). 2. Set LTR on receive loss-of-signal (LOS) (bit 5). Note: If it is desired to allow the CDR to acquire lock to the incoming data while LTR at Register 7, Bit 1 is set to 1 (Lock to Reference clock enabled), set CDRLTDATA at Register 7, Bit 4 to 1 (default). If it is desired to sample the incoming data with a programmable phase and slice level while LTR is set to 1, set sliceEn[2:0] at Register 20 to 000 binary (auto slice disabled). 5.8. Receiver Loss of Lock (LOL) Receiver LOL functions differently depending on whether the receiver is operating in reference or referenceless mode. By default (uselolmode Register 7, Bit 3 = 0), SQM-based LOL is used in referenceless mode, and Frequency-based LOL is used in reference mode. In reference mode however, either SQM or Frequency LOL can be used by setting Register 7, Bits 2 and 3 to the appropriate values. 5.8.1. SQM LOL SQMLOL mode is selected in one of two ways. If register 7[3:2] = 11b, then SQMLOL mode is selected. If register 7[3] = 0 and register 7[1] = 0, then SQMLOL mode is selected. The SQMLOL method compares an internal jitter measure to the sqmLOLThresh (see below on how to set this threshold). When the internal jitter measure is greater than the sqmLOLThresh, RXLOL is asserted. When RxLOL is asserted the 5040 RX side will automatically start to try to acquire lock again across an input data range of 9.8–11.4 Gbps. RxLOL is deasserted when the jitter measure is less than the sqmLOLThresh. The sqmLOLThreshold must be set using registers 106, 107, 108, and 109 in the following order: 1. Write register 107 = A0h. 2. Write register 108 = 3Fh. 3. Write register 109 = B9h. 4. Write register 106 = 04h. 5. Write register 106 = 84h. These are indexed address registers. Register 106 contains the sqmLOLThresh register address and 107-109 contain the data to be written to it. Register 106 must be written twice. The first write of 04h sets the address, and 84h applies the value in 107-109 into the sqmLOLThresh registers. The above values are recommended for all applications. Using sqmLOLThresh values other than the default or the one given above can cause unexpected problems, such as false lock, and are not recommended. 24 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 5.8.1.1. Dynamic Register Control The dynamic control of RxLoopFAcq (Register 98) is required to ensure the locking performance of the CDR. It is required for all applications that RxLoopFAcq be set to 98h when RX LOL is asserted and to 00h when RX LOL is deasserted. Only the default value and the value given above are supported for writes to Register 98. Any read back of this register will not necessarily return the value written. If a valid reference clock is applied at pins 13,14 and rxRefclkEn = 1 (reg7[0]) and Rx VCOCAL = x0b (reg8[2:1]), then the dynamic register write to register 98 is not necessary. N ot fo R r N ec o ew m m D e es nd ig e ns d In addition, for proper LOL performance, RxPDGainAcq (Register 77) must be written once to 0Dh after power is applied or a SW reset is implemented. If a valid reference clock is applied at pins 13,14 and rxRefclkEn = 1 (reg7[0]) and Rx VCOCAL = x0b (reg8[2:1]), then it is not necessary to write to register 77. 5.8.2. Frequency LOL The Si5040 supports the use of a ~622 MHz or ~155 MHz (/64 or /16) reference clock. The reference clock frequency is selected in the ChipConfig1 register (Register 2). There are two ways in which FREQLOL is selected. When register7[3:2] = 10b, then FREQLOL is selected. When register7[3] = 0 and register7[1] = 1, then FREQLOL is selected. LOL is asserted if the recovered clock frequency deviates from the reference clock frequency by >±1000 ppm. LOL is de-asserted if the recovered clock is within ±200 ppm of the reference clock frequency. Refer to Figure 14 for CDR and VCO behaviors upon declaring LOL. 5.8.3. Acquisition Time Enhancement The acquisition lock time for a signal applied at RXDIN can be reduced to less than 15 ms by the following register writes: 1. Write register 86 = 0011 1000 = 38h. 2. Write register 67 = 0100 0001 = 41h. 3. Write register 68 = 0000 0011 = 03h. 5.8.4. LOL Interrupt LOL may be configured to generate an interrupt. The status of the LOL interrupt bit can be read from the RxintStatus register (Register 5). The status of LOL may also be read from the RxAlarmStatus register (Register 9). LOL may also be asserted upon activation of LOS (see "5.4. Receiver Loss of Signal Alarm (LOS)" on page 20 and Figure 15 on page 26). Receive data (RD) may be squelched on LOL. This option is configured in the RxdPathConfig register (Register 28). Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 25 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 aLOSThresh (Bit 1:0, Register 13 and Bit 7:0, Register 12) aLOSHyst[3:0] (Bit 7:4, Register 13) Peak-toPeak Monitor aLOS (Bit 1, Register 11) N ot fo R r N ec o ew m m D e es nd ig e ns d aLosEn (Bit 0, Register 10, Default= 1) RxdLosAssertThresh[7:0] (Bit 7:0, Register 17) RxdLosClearThresh (Bit 7:0, Register 18) DLOS Monitor 00: 01: 01: 01: LOS (Bit 5, Register 9, Bit 0, Register 11 or Pin 3) dLOS (Bit 2, Register 11) EN dLosEn[1:0] (Bit 2:1, Register 10) Disabled (Default) Based on consecutive number of 1s Based on consecutive number of 0s Based on either consecutive number of 1s or 0s RxSqmThresh[5:0] (Bit 7:2, Register 26) RxSqmDeassertThresh[5:0] (Bit 5:0, Register 27) 1 EN Signal Quality Monitor sqmAlarm (Bit 0, Register 9) sqmLOS (Bit 4, Register 11) sqmLosEn (Bit 3, Register 10, Default= 0) lolOnLos (Bit 6, Register 7, Default= 0) RxSqmValue[5:0] (Bit 5:0, Register 25) LOL (Bit 4, Register 9 or Pin 2) SqmLol 1 (Default) Rx Recovered Clock Reference Clock Frequency Offset Monitor FreqLol 0 Select lolMode (Bit 2, Register 7) useLolMod (Bit 3, Register 7, Default= 0) Figure 15. RX LOS and LOL Block Diagram 26 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 TxdLosAssertThresh[7:0] (Bit 7:0, Register 145) TxdLosClearThresh (Bit 7:0, Register 146) dLosEn[1:0] (Bit 2:1, Register 138) dLOS (Bit 2, Register 139) DLOS Monitor LOS (Bit 5, Register 137 or Bit 0, Register 139) EN N ot fo R r N ec o ew m m D e es nd ig e ns d 00: Disabled (Default) 01: Based on consecutive number of 1s 01: Based on consecutive number of 0s 01: Based on either consecutive number of 1s or 0s TxSqmThresh[5:0] (Bit 7:2, Register 154) TxSqmDeassertThresh[5:0] (Bit 5:0, Register 155) 1 EN sqmAlarm (Bit 0, Register 137) Signal Quality Monitor sqmLOS (Bit 4, Register 139) sqmLosEn (Bit 3, Register 138, Default= 0) TxSqmValue[5:0] (Bit 5:0, Register 153) SqmLol 1 (Default) Tx Recovered Clock Reference Clock Frequency Offset Monitor FreqLol LOL (Bit 4, Register 137) 0 Select useLolMod lolMode (Bit 2, Register 135) (Bit 3, Register 135, Default= 0) Figure 16. TX LOS and LOL Block Diagram Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 27 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 5.9. Receiver Phase Adjust The Si5040 receiver supports programmable sample phase adjust. The sampling point may be advanced or delayed in time by adjusting the value loaded into the RxPhaseAdjust register (Register 24). The range of adjustment is ±12 ps. 5.10. Receive Clock Multiplier Unit N ot fo R r N ec o ew m m D e es nd ig e ns d The Si5040 receiver incorporates a DSPLL®-based clock multiplier unit (CMU) that attenuates the jitter on data recovered from the line interface. This makes it much easier to significantly exceed the jitter requirements for 10 Gbit SONET, Ethernet, and Fibre Channel applications. The CMU is rate-adaptable across the entire range of device operation. Note that when the ltr bit or ltrOnLOS bit in Register 7 is set to 1, the receive CMU is locked to the reference clock. The receiver CMU supports 380 kHz bandwidth (cmuBandwidth[3:0] at Register 6 = 0100). 5.11. Recommended Pre-Emphasis on the RD Signal Even though the RD signal rise/fall time is very fast, some users may wish to add high-frequency boost to the RD signal. This is done with an external RC network to reduce low-frequency energy, effectively boosting the high frequencies. To compensate for loss in the circuit and maintain proper signal size and eye opening at the XFI connector, the RD amplitude will have to increase to 700 or 800 mV. Register 56 controls the RD signal amplitude. The resistors and capacitors can be generic low-cost components, and the circuit should be located very close to the Si5040 RD± pins. This circuit is recommended for all XFP applications. 5040 R D + XFI RD+ 20 .5 274  3 .0 p f 3 .0 p f .0 1 µ F 274  20 .5 XFI RD- 5040 R D - Figure 17. RD Pre-Emphasis Circuit 28 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 6. Transmitter The Si5040 transmitter includes an XFI-compliant, fixed-equalizer CDR for recovery of clock and data from the XFI channel (TD inputs), pattern generation and checking function (see “6.3. Clock and Data Recovery (CDR)”), transmit FIFO, and jitter-attenuating clock multiplier unit. 6.1. Transmitter Loss-of-Signal Alarm (LOS) N ot fo R r N ec o ew m m D e es nd ig e ns d The Si5040 transmitter generates a loss-of-signal alarm when the TD input signal fails to meet the selected programmable condition for Transmit Loss of Signal. The programmable LOS mode is controlled in the TxLosCtrl register (Register 138). The available modes are Digital Loss of Signal (DLOS) and Signal Quality Monitor (SQM). The state of LOS is reflected in the LOS bit in the TxLosStatus register (Register 139). LOS may also be configured to generate an interrupt. The status of the LOS interrupt bit may be read in the TxintStatus register (Register 133). The status of the various LOS modes is stored in the TxLosStatus register (Register 139). A DLOS alarm occurs when the bit stream on the TD input contains a run length of ones or zeroes greater than the value loaded in the TxdLosAssertThresh register (Register 145). dLos will remain asserted until the bit stream shows activity for a time greater than that loaded in the TxdLOSClearThresh register (Register 146). An SQM alarm occurs when the TD input signal quality falls below the value loaded in TxSqmThresh (Register 154). The Signal Quality Monitor measures the magnitude of the horizontal eye opening of the received signal. The SQM value can be read from the TxsqmValue register (Register 153). An SQM alarm will assert if the TxsqmEn bit has been set in the TxSqmConfig register (Register 154). SQM hysteresis is set in the TxsqmDeassertThresh register (Register 155). The transmitter may be programmed to cause the following events on an LOS condition: 1. Disable (squelch) the transmitter data output (TXDOUT) (Register 156). 2. Generate a clock pattern at the transmit data output (TXDOUT) (Register 156). 6.2. Transmit Equalizer The TX equalizer is a passive, fixed-gain equalizer based on the inverse response of the XFI channel. The equalizer attenuates the low-frequency components of the input signal to compensate for the high-frequency losses through the XFI channel. The overall frequency response through the XFI channel and the equalizer should be essentially flat. 6.3. Clock and Data Recovery (CDR) The Si5040 integrates a CDR to recover the clock and data from the signal applied to the TD input. The CDR may be operated with or without an external reference clock. Reference and referenceless operation is programmed in the TxCalConfig register (Register 136). If a reference clock is applied, the CDR may be forced to lock to the reference clock in the event that a loss of signal occurs. This option is programmed in the TxConfig register (Register 135). Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 29 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 6.4. Transmitter Loss of Lock (LOL) Transmitter LOL functions in different ways depending on whether the transmitter is operating in reference or referenceless mode. By default (uselolmode Register 135, Bit 3 = 0), SQM-based LOL is used in referenceless mode, and Frequency-based LOL is used in reference mode. However, in reference mode, either SQM or Frequency LOL can be used by setting Register 135, Bits 2 and 3, to the appropriate values. 6.4.1. SQM LOL N ot fo R r N ec o ew m m D e es nd ig e ns d When the VCO is configured to calibrate without a reference clock (VCOCAL[1:0] = 01 binary), the default values of register 135[3:2] will cause the LOL method to be SQMLOL. Just as in the receiver (see "5.8.1. SQM LOL" on page 24), the SQMLOL method compares an internal jitter measure to the sqmLOLThresh; however, the TX sqmLOLThresh value must not be modified. When the internal jitter measure is greater than the sqmLOLThresh, TXLOL is asserted. TxLOL is deasserted when the jitter measure is less than the sqmLOLThresh. 6.4.1.1. Dynamic Register Control The dynamic control of TxLoopFAcq (Register 226) is required to ensure the locking performance of the CDR. For all applications, it is required that TxLoopFAcq be set to 98h when TX LOL is asserted and to 00h when TX LOL is deasserted. Only the default value and the value given above are supported for Register 226. Any read back of this register will not necessarily return 98h. If a valid reference clock is applied at pins 13,14 and the Tx VCOCAL = x0b (reg136[2:1]), then the dynamic register write to register 226 is not necessary. In addition, for proper LOL performance, TxPDGainAcq (Register 205) must be written once to 0Dh after power is applied or a SW reset is implemented. If a valid reference clock is applied at pins 13,14 and Tx VCOCAL = x0b (reg136[2:1]) then it is not necessary to write to register 205. 6.4.2. Frequency LOL The Si5040 supports the use of a ~622 MHz or ~155 MHz (/64 or /16) reference clock. When FREQLOL is set (Register 135[3:2] = 10b), LOL is asserted if the recovered clock frequency deviates from the reference clock frequency by >±1000 ppm. LOL is de-asserted if the recovered clock is within ±200 ppm of the reference clock frequency. The reference clock frequency is selected in the ChipConfig1 register (Register 2). Refer to Figure 14 for CDR and VCO behaviors upon declaring LOL. 6.4.3. Acquisition Time Enhancement The acquisition time for a signal applied at TD can be reduced to less than 15 ms by the following register writes:  Register 195 = 0100 0000 = 40h  Register 196 = 0000 0111 = 07h  Register 214 = 0011 1000 = 38h 6.4.4. LOL Interrupt LOL may be configured to generate an interrupt. The status of the LOL interrupt bit can be read from the TxintStatus register (Register 133). The status of LOL may also be read from the TxAlarmStatus register (Register 137). Transmitter data (TXDOUT) may be squelched on LOL. This option is configured in the TxdPathConfig register (Register 156). 6.5. Transmitter Phase Adjust The Si5040 transmitter supports manual sample phase adjust. The sampling point may be advanced or delayed in time by adjusting the value loaded into the PhaseAdjust register (Register 152). The range of adjustment is >±12 ps. Note that the transfer function from the register value to the phase adjust time is highly variable; therefore, we only guarantee that the largest or smallest register value will achieve better than +12 ps or –12 ps, respectively. 6.6. Transmit Clock Multiplier Unit The Si5040 transmitter incorporates a DSPLL®-based clock multiplier unit (CMU) that attenuates the jitter on the data recovered from the XFI interface. This makes it much easier to significantly exceed the jitter requirements for 10 Gbit SONET, Ethernet, and FibreChannel applications. The CMU is rate-adaptable across the entire range of device operation. Selectable CMU bandwidths support adjustment of the degree of jitter filtering required for a given application. 30 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 6.7. Timing Modes Of Operation For maximum flexibility, the Si5040 supports three CMU timing modes that make it suitable for XFP modules targeted at both datacom and telecom applications. The modes of operation determine how the transmit CMU is configured. Timing modes are set in the TxCmuConfig register (Register 134). 6.7.1. Referenceless Mode (Mode 0) N ot fo R r N ec o ew m m D e es nd ig e ns d In the referenceless mode of operation, timing information is recovered from the XFI data and used as the timing source for the transmit CMU (Figure 18). The mode is set in TxCmuConfig (Register 134). This mode should be chosen when a synchronous reference clock is not available or if the jitter on the recovered XFI data is less than that on the available synchronous reference clock. Optionally, an asynchronous reference clock at a frequency of 1/64 of the baud rate (as defined in the XFP specification) may be applied for VCO centering purposes and to generate receive LOL and transmit LOL. However, a reference clock is not necessary to generate these signals. Referenceless mode is the default mode after power-on. 6.7.2. Synchronous Reference Clock Mode (Mode 1) If an external synchronous reference clock with jitter characteristics of higher quality than those of the recovered XFI clock is available, the device may be operated in Synchronous Reference Clock Mode (Figure 19). The mode is set in TxCmuConfig (Register 134). In this mode, the transmit CMU derives the line-rate clock by multiplying the clock frequency applied to the REFCLK inputs by 64. This mode is equivalent to the "Optional Synchronous CMU Clock" mode described in the XFP specification (see XFP MSA Rev. 4.0 Section 3.9.1). It is not necessary to meet the phase noise characteristics defined for the synchronous reference clock in the XFP specification since the Si5040 transmit CMU attenuates jitter on the reference clock. 6.7.3. Asynchronous Reference Clock Mode (Mode 2) If an external asynchronous reference clock with jitter characteristics of higher quality than those of the recovered XFI clock is available, the device can be operated in Asynchronous Reference Clock Mode (Figure 20). The mode is set in TxCmuConfig (Register 134). The external reference clock is used as the timing source for the transmit CMU. The resulting transmit clock is frequency locked to the incoming data, and the jitter on the transmit clock is reduced due to the low jitter of the applied reference clock. The transmit CMU bandwidth may be set to 180 or 1370 Hz, depending on how much jitter is present on the applied reference clock. A FIFO in the data path accommodates any jitter differences between the serial data and the CMU line-rate clock. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 31 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 DSPLL ® Jitter Attenuator CMU N ot fo R r N ec o ew m m D e es nd ig e ns d XFI Recovered Clock TXDOUT CML CDR FIFO Equalizer XFI Recovered Data TD Figure 18. Referenceless Mode (Mode 0) DSPLL ® Jitter Attenuator CMU Synchronous Reference Clock XFI Recovered Clock TXDOUT CML CDR FIFO Equalizer XFI Recovered Data TD Figure 19. Synchronous Reference Clock (Mode 1) DSPLL® Jitter Attenuator CMU Cleaned Up Clock XFI Recovered Clock TXDOUT CML FIFO XFI Recovered Asynch Ref Clock (Mode 2) Phase Phase in out CDR Equalizer TD Data Figure 20. Mode 2 32 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 7. Loopback Modes The Si5040 supports XFI Loopback, Lineside Loopback, and Looptime modes. 7.1. XFI Loopback N ot fo R r N ec o ew m m D e es nd ig e ns d The Si5040 is configured in the XFI Loopback mode by writing to the ChipConfig1 register (Register 2). The Si5040 is configured in the XFI Loopback mode by writing to the ChipConfig1 register (Register 2). Data on the TD input is retimed and output on the RD output. The clock recovered from the XFI data (TD) is used as the timing source for the RD output. For this reason, RX VCOCAL (Register 8, Bit [2:1]) must be set to reference or auto mode. If the data from the transmitter is not required at the TXDOUT output pins, it may be disabled by writing to the transmitter Squelch bit in the dPath register (Register 156, bit 2). Data on the TD input is retimed and output on the RD output. The clock recovered from the XFI data (TD) is used as the timing source for the RD output. 7.2. Lineside Loopback The Si5040 is configured in the Lineside Loopback mode by writing to the ChipConfig1 register (Register 2). Data received on the receiver input (RXDIN) is output on the transmitter (TXDOUT) output. Since in this mode the clock recovered from the receiver input is used as the timing source for the transmit CMU, TX VCOCAL (Register 136, Bit [2:1]) must be in reference or auto mode. If the data from the receiver is not required at the XFI interface, it may be disabled by writing to the receiver Squelch bit in the dPath register (Register 28, bit 2). 8. Looptime Mode The Si5040 supports looptime mode for applications in which it is desirable to time the transmitter off the receiver clock. Data received at the XFI interface (TD) is retimed using the clock recovered from the receiver (RXDIN). As a result of the transmit CMU jitter attenuation feature in the Si5040, with the appropriate setting of the CMU bandwidth (set in Register 134), the jitter on the recovered clock is significantly attenuated so that the data on the transmit output will be compliant with the datacom and telecom standards supported by the Si5040. A FIFO within the data path accommodates any jitter differences between the serial data and the CMU line-rate clock. Looptime mode is enabled by writing to the TxCmuConfig register (Register 134). Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 33 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 9. Pattern Generation and Checking The Si5040 includes a programmable pattern generator and checker function in both the receiver and transmitter signal paths. The Si5040 can generate and check PRBS7, PRBS31, or a 64-bit, user-defined pattern programmed in the tpSel register (receiver Register 29, transmitter Register 157). N ot fo R r N ec o ew m m D e es nd ig e ns d Notes: 1. When PRBS7 or PRBS31 is selected for the pattern generator or checker, the pattern can either be inverted or noninverted by programming the tpGenInvert and tpChkInvert bits in the pgSel register (receiver Register 29, transmitter Register 157). Per Section 5.8 in O.150, PRBS31 is specified as an inverted pattern. The pattern generators default to generating an inverted PRBS31 to comply with 0.150. However, the pattern generators and checkers have the option to invert the pattern. 2. The pattern checker will report no error if the input sequence is an all 0s pattern. However, a loss-of-lock or loss-of-signal indicator will assert in these conditions. The user-defined patterns are programmed in the tpArbGenPtn and tpArbChkPtn registers (receiver Registers 31– 38 and transmitter Registers 159–166). The time period or number of bits over which the checker should look for errors is defined in the tpTimeBase bits located in the tpChkConfig register (receiver Register 30, transmitter Register 158). The time base can be programmed to be infinite (always looking for errors) or set to one of three defined values. Changing to another time base will reset the error counter. The pattern checker offers a Loss-of-Sync indicator along with a 40-bit error count register and an 8-bit error count register in floating point notation. When the checker achieves synchronization between the expected and the received pattern, the tpSyncLos register (receiver Register 9, transmitter Register 137) is deasserted. Note that as soon as the checker is synchronized, the error count register is reset to 0, and error counting begins. As soon as the checker loses synchronization in the middle of a measuring window defined by the tpTimeBase register, the error count register is loaded with all 1s, indicating the maximum error count. In order to differentiate between a Loss-of-Sync event and a bit error event, the user should monitor both the tpSyncLos register and the error count register described below. The tpChkErrCnt register holds the error count from the last completed time base if the checker is in a defined time base mode; otherwise, in the infinite time base setting, the current running error count is stored. An interrupt is generated when the number of errors exceeds the value loaded in the 8-bit tpTargetErr register (receiver Register 47, transmitter Register 175). The tpChkErr register holds the error count in an 8-bit floating point format. In order for the pattern generation/check function to operate correctly, a timing source must be applied. A valid timing source for the receiver pattern generation/check function can be any of the following:  A reference clock with the device placed in lock-to-reference mode. Data applied at the RXDIN inputs from which a recovered clock can be derived.  Data applied at the TD inputs from which a recovered clock can be derived and with the device placed in XFI loopback mode. A valid timing source for the transmitter pattern generation/check function can be any of the following:   A reference clock with the device placed in lock-to-reference mode.  Data applied at the TD inputs from which a recovered clock can be derived.  Data applied at the RXDIN inputs from which a recovered clock can be derived and with the device placed in Looptime mode. 34 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 10. Serial Microcontroller Interface Device control and status monitoring is supported with a selectable I2C or SPI-like interface. SPSEL (Pin 9) controls which of the two serial formats is selected. 10.1. I2C Interface N ot fo R r N ec o ew m m D e es nd ig e ns d When configured in I2C control mode (pin SPSEL tied low), the control interface to the Si5040 is a 2-wire bus for bidirectional communication. The bus consists of a bidirectional serial data line (SD) and a serial clock input (SCK). The SD pin may be configured as a CMOS output or as an open drain output using Register 2, bit 4. Fast mode operation is supported for transfer rates up to 400 kbps as specified in the I2C-Bus Specification standard. A chip select pin is provided (SS) to address the Si5040. Figure 21 shows the command format for both read and write access. Data is always sent MSB first. Table 2 on page 6 and Table 3 on page 8 give the dc and ac electrical parameters for the SCK and SD I/Os, respectively. The timing specifications and timing diagram for the I2C bus can be found in the I2C-Bus Specification standard (fast mode operation). S Slave Address 0 A Byte Address A Data A Data A P Write Command S Slave Address 0 A Byte Address A S Slave Address 1 A Data A Data A P Read Command Address auto incremented after each data read or write 1 Read 0 Write A – Acknowledge (SD LOW) From master to slave S – START condition P – STOP condition From slave to master Figure 21. I2C Command Format The device has two possible I2C addresses depending on the SSb pin setting. If the SSb pin is floating or externally tied high, the device has an I2C address of 7d' 1000001. If the SSb pin is externally tied low, the device has an I2C address of 7d' 1000000. For applications that require two Si5040 devices connected on the same I2C bus, each individual device can be accessed with a unique I2C address depending on the SSb pin setting. Figure 22 illustrates how the I2C address can be configured and what the expected value is for the first byte after the START condition. Note that the first byte after the START condition could be either 82h or 83h depending on whether it's a read or write. The first byte after the START condition could be either 80h or 81h depending on whether it is a read or write. By design, this bit in the I 2C address is determined by the SSb pin. 1 0 0 0 0 0 Per I2C specification, this bit is either 1 for read or 0 for write. X Source: Fig 14 of I2C – Bus Specification Version 2.1 Figure 22. Device I2C Address Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 35 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 10.2. SPI-Like Interface When configured in SPI-like control mode (pin SPSEL tied high), the control interface to the Si5040 is a 3-wire interface modeled close to commonly-available microcontrollers and bidirectional serial peripheral devices. The interface consists of a clock input (SCK), slave select input (SS), and serial data input/output (SD). The SD pin may be configured as a CMOS output or as an open drain output using Register 2, bit 4. N ot fo R r N ec o ew m m D e es nd ig e ns d Data is transferred one byte at a time, with each register access consisting of a pair of byte transfers. Figure 7 and Figure 8 on page 15 illustrate read and write/set address operations on the SPI bus, and Table 9 on page 14 gives the timing requirements for the interface. Table 12 shows the SPI command format. The first byte of the pair is the instruction byte. The "Set Address" command writes the 8-bit address value that will be used for the subsequent read or write. The "Write" command writes data into the device based on the address previously established, and the "Write/ Address Increment" command writes data into the device and automatically increments the register address for use on the subsequent command. The "Read" command reads one byte of data from the device, and the "Read/Address Increment" reads one byte and increments the register address automatically. The second byte of the pair is the address or data byte. As shown in Figure 7 and Figure 8 on page 15, SS should be held low during the entire two byte transfer. Raising SS resets the internal state machine; so, SS must be raised between each two byte transfers to guarantee that the state machine will be reinitialized. During a read operation, the SD becomes active on the falling edge of SCK, and the 8-bit contents of the register are driven out MSB first. The SD is high-impedance on the rising edge of SS. During write operations, data is driven into the Si5040 via the SD pin MSB first. Data always transitions with the falling edge of the clock and is latched on the rising edge. The clock should return to a logic high when no transfer is in progress. The Si5040 SPI-like interface supports continuous clocking operation where SS is used to gate two byte transfers. Table 12. SPI-Like Command Format Instruction 36 Address/Dat 00000000—Set Address AAAAAAAA 01000000—Write DDDDDDDD 01100000—Write/Address Increment DDDDDDDD 10000000—Read DDDDDDDD 10100000—Read/Address Increment DDDDDDDD Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 11. Interrupt Functionality N ot fo R r N ec o ew m m D e es nd ig e ns d Alarm Status bits (Register 9/137) are sampled by a 10 MHz clock to create the Interrupt Status bits (Register 5/133). If the Interrupt Enable bit (Register 2, bit 5) is a zero, all the Interrupt status bits are forced to zero. The Alarm Status bits are always active regardless of the state of the Interrupt Enable bit and the Interrupt Mask bits. The Interrupt Mask bits (Register 4/132) masks the Alarms Status bits from affecting the corresponding Interrupt Status bit. Writing a zero to an Interrupt Status bit forces that bit to a zero; however, if the corresponding Alarm bit is active and the Interrupt Mask bit is not set, the next 10 MHz clock cycle will again cause the Interrupt Status bit to set. All of the Interrupt Status bits are logically “NORed” together to create the Interrupt bit (or pin16). Please refer to Figure 23 for an illustration of the device interrupt tree. The polarity of the Interrupt (pin 16) is active low. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 37 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 RX_REFLOS Interrupt Status (sticky) bit (Register 5, bit 6) RX_REFLOS Alarm status bit (Register 9, bit 6) Q D CK RX_REFLOS Interrupt mask bit (Register 4, bit 6) C N ot fo R r N ec o ew m m D e es nd ig e ns d 10 MHz Clock Clear RX_LOS Alarm status bit (Register 9, bit 5) Interrupt Enable (Register 2, bit 5) Q D CK C 10 MHz Clock Write-to-Clear Clear RX_LOL Alarm status bit (Register 9, bit 4) RX_LOL Interrupt Status (sticky) bit (Register 5, bit 4) Q C RX_LOL Interrupt mask bit (Register 4, bit 4) 10 MHz Clock Clear RX_LOS Interrupt mask bit (Register 4, bit 5) Interrupt Enable (Register 2, bit 5) D CK RX_LOS Interrupt Status (sticky) bit (Register 5, bit 5) Interrupt Enable (Register 2, bit 5) INTERRUPT Interrupt pin (Open drain or LVTTL , Active Low) TX_REFLOS Alarm status bit (Register 137, bit 6) CK C TX_REFLOS Interrupt mask bit (Register 132, bit 6) 10 MHz Clock Clear TX_LOS Alarm status bit (Register 137, bit 5) Interrupt Enable (Register 2, bit 5) C TX_LOS Interrupt mask bit (Register 132, bit 5) 10 MHz Clock Clear TX_LOL Alarm status bit (Register 137, bit 4) Interrupt Enable (Register 2, bit 5) C 10 MHz Clock Clear TX_LOL Interrupt Status (sticky) bit (Register 132, bit 4) Q D CK TX_LOS Interrupt Status (sticky) bit (Register 133, bit 5) Q D CK TX_REFLOS Interrupt Status (sticky) bit (Register 133, bit 6) Q D TX_LOL Interrupt mask bit (Register 132, bit 4) Interrupt Enable (Register 2, bit 5) Figure 23. Device Interrupt Tree 38 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 12. Programmable Power-Down Options N ot fo R r N ec o ew m m D e es nd ig e ns d The RX and TX paths can be powered down independently by programming RxPdn = 1 at Register 3, Bit 0 (Default = 0) or TxPdn = 1 at Register 131, Bit 0 (Default = 0), respectively. As long as both paths are not powered down, all registers are still accessible. Any values written to the registers of the powered-down path will have no immediate effect but will take effect once the path is powered back up and a recalibration is initiated (RX hardRecal at Register 8, Bit 3 or TX hardRecal at Register 136, Bit 3). Any read of registers of the powered-down path will return garbage as there is no VCO clock. When both the RX and TX paths are powered down, there is a special power up requirement that depends upon the state of the SPSEL pin. If SPSEL is high, any read or write access will wake up the device. The path that was last powered down will be powered up first. The other path can then be powered up by setting the appropriate Pdn bit to a zero. Each side that is powered up must have a hard recal performed to calibrate all circuits (RX hardRecal at Register 8, Bit 3, or TX hardRecal at Register 136, Bit 3). If SPSEL is low (I2C mode), power up from both sides powered down can only be accomplished by physically removing VDD from the Si5040 and then re-applying VDD. Of course, this will power up both sides of the device, and a hard recal will automatically occur. Note that interrupts must be masked or ignored during power down and unmasked and cleared after the recalibration. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 39 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 13. Si5040 Register Summary Any reserved bits listed in the table below or reserved registers (23, 54–55, 58–76, 78–83, 86–97, 99–105, 110– 130, 140–144, 148–151, 182–183, 185–204, 206–225, and 227–255) must not be written to a non-default value. All reserved bits have the default values shown below. Reg Name Default Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 N ot fo R r N ec o ew m m D e es nd ig e ns d Receiver 0 Part Identifier 40h 1 Part Identifier 30h 2 ChipConfig1 58h losOpen Drain intOpen Drain intEnable spiOpen Drain Reserved linesideLoopback XFILoopback refClkFreq 3 RxChipConfig2 0h Reserved Reserved Reserved Reserved Reserved Reserved Reserved RxPdn 4 RxintMask 0h Reserved refLOS LOS LOL fifoErr tpErrAlarm tpSyncLos sqmAlarm 5 RxintStatus (Sticky Bits) 0h Reserved refLOS LOS LOL fifoErr tpErrAlarm tpSyncLos sqmAlarm 6 RxCmuConfig 40h 7 RxConfig 15h Reserved lolOnLOS ltrOnLOS CDRLTDATA uselolMode 8 RxCalConfig 0h Reserved Reserved Reserved Reserved hardRecal 9 RxAlarmStatus 0h Reserved refLOS LOS LOL fifoErr 10 RxLosCtrl 1h Reserved Reserved Reserved Reserved sqmLosEn 11 RxLosStatus 0h Reserved Reserved Reserved sqmLos dLOSlastTrigger 12 aLosThresh Fh 13 aLosThresh2 70h 15 peakDet 0h 16 peakDet 0h 17 RxdLosAssertThresh 5h RxdLosAssertThresh[7:0] 18 RxdLos ClearThresh 60h RxdLosClearThresh[7:0] 20 sliceConfig 11h 21 sliceLvl 0h sliceLvl[7:0] 22 sliceLvl 0h sliceLvl[15:8] 24 RxphaseAdjust 0h Reserved 25 RxSqmValue N/A Reserved 26 RxSqmConfig 29h 27 RxSqmDeassertThresh Fh Reserved Reserved 28 RxdPathConfig 2h Reserved dinvert 29 RxtpSel 0h tpChkInvert 40 Identifier[7:0] Revision[3:0] Identifier[3:0] cmuBandwidth[3:0] Reserved Reserved lolMode ltr rxRefclkEn VCOCAL[1:0] tpErrAlarm tpSyncLos swReset sqmAlarm dLosEn[1:0] dLOS aLosEn aLOS LOS aLOSThresh[7:0] aLosHyst[3:0] Reserved aLosThresh[1:0] peakDet[7:0] Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved peakDet[1:0] Reserved sliceEn[2:0] RxphaseAdjust[6:0] Reserved RxSqmValue[5:0] RxSqmThresh[5:0] Reserved Reserved FIFOAutoReset FIFOReset RxSqmDeassertThresh[5:0] clkOnLOS tpChkSel[2:0] SquelchOn- SquelchOnRxLOL RxLOS tpGenInvert Squelch tpGenSel[2:0] Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Name Default Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 30 RxtpChkConfig 2h Reserved Reserved Reserved Reserved Reserved tpSyncMask 31 RxtpArbGenPtn AAh RxtpArbGenPtn[7:0] 32 RxtpArbGenPtn AAh RxtpArbGenPtn[15:8] 33 RxtpArbGenPtn AAh RXtpArbGenPtn[23:16] 34 RxtpArbGenPtn AAh RxtpArbGenPtn[31:24] 35 RxtpArbGenPtn AAh RxtpArbGenPtn[39:32] 36 RxtpArbGenPtn AAh RxtpArbGenPtn[47:40] 37 RxtpArbGenPtn AAh RxtpArbGenPtn[55:48] 38 RxtpArbGenPtn AAh RxtpArbGenPtn[63:56] 39 RxtpArbChkPtn AAh RxtpArbChkPtn[7:0] 40 RxtpArbChkPtn AAh RxtpArbChkPtn[15:8] 41 RxtpArbChkPtn AAh RxtpArbChkPtn[23:16] 42 RxtpArbChkPtn AAh RxtpArbChkPtn[31:24] 43 RxtpArbChkPtn AAh RxtpArbChkPtn[39:32] 44 RxtpArbChkPtn AAh RxtpArbChkPtn[47:40] 45 RxtpArbChkPtn AAh RxtpArbChkPtn[55:48] 46 RxtpArbChkPtn AAh RxtpArbChkPtn[63:56] 47 RxtpTargetErr FFh RxtpTargetErr[7:0] 48 RxtpChkErrCnt N/A RxtpChkErrCnt[7:0] 49 RxtpChkErrCnt N/A RxtpChkErrCnt[15:8] 50 RxtpChkErrCnt N/A RxtpChkErrCnt[23:16] 51 RxtpChkErrCnt N/A RxtpChkErrCnt[31:24] 52 RxtpChkErrCnt N/A RxtpChkErrCnt[39:32] 53 RxtpChkErr N/A RxtpChkErr[7:0] 56 OutputLevel F5h 77 RxPDGainAcq 8Dh RxPDGainAcq[2:0] 84 RxEqConfig1 A1h RxEqGain Reserved 85 RxEqConfig2 E0h RxEqHFBoost Reserved 98 RxLoopFAcq 1Eh RxLoop FAcqCtl 106 sqmLOLThreshWrt 00h sqmLOL ThreshWrt Reserved 107 sqmLOLThresh 00h sqmLOL Thresh[0] Reserved 108 sqmLOLThresh 00h 109 sqmLOLThresh 00h Bit 1 HsPowerCtl[1:0] Reserved Reserved Reserved Reserved Reserved Bit 0 tpTimeBase[1:0] N ot fo R r N ec o ew m m D e es nd ig e ns d Reg outLevel[2:0] Reserved Reserved Reserved Reserved Reserved RxLoopFAcq[6:0] sqmLOLThreshAdd[5:0] Reserved Reserved Reserved Reserved sqmLOLThresh[8:1] Reserved Reserved sqmLOLThresh[13:9] Reserved Transmitter 131 TxChipConfig2 22h Reserved Reserved Reserved Reserved Reserved Reserved XORATE TxPdn Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 41 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Reg Name Default Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 132 TxintMask 0h Reserved refLOS LOS LOL fifoErr tpErrAlarm tpSyncLos sqmAlarm 133 TxintStatus (Sticky Bits) 0h Reserved refLOS LOS LOL fifoErr tpErrAlarm tpSyncLos sqmAlarm 134 TxCmuConfig 40h 135 TxConfig 94h cmuBandwidth[3:0] Reserved Reserved CDRLTDATA uselolMode cmuMode[2:0] lolMode ltr N ot fo R r N ec o ew m m D e es nd ig e ns d Reserved Reserved 136 TxCalConfig 0h Reserved Reserved Reserved Reserved hardRecal 137 TxAlarmStatus 0h Reserved refLOS LOS LOL fifoErr 138 TxLosCtrl Eh Reserved Reserved Reserved Reserved sqmLosEn 139 TxLosStatus 0h Reserved Reserved Reserved sqmLOS dLOSlastTrigger 145 TxdLosAssertThresh 00 TxdLosAssertThresh[7:0] 146 TxdLos ClearThresh 60h TxdLosClearThresh[7:0] 152 TxPhaseAdjust 0h Reserved 153 TxSqmValue 0h Reserved 154 TxSqmConfig 05h 155 TxSqmDeassertThresh 08h Reserved Reserved 156 TxdPathConfig 2h Reserved dinvert 157 TxtpSel 0h tpChkInvert 158 TxtpChkConfig 2h Reserved 159 TxtpArbGenPtn AAh TxtpArbGenPtn[7:0] 160 TxtpArbGenPtn AAh TxtpArbGenPtn[15:8] 161 TxtpArbGenPtn AAh TXtpArbGenPtn[23:16] 162 TxtpArbGenPtn AAh TxtpArbGenPtn[31:24] 163 TxtpArbGenPtn AAh TxtpArbGenPtn[39:32] 164 TxtpArbGenPtn AAh TxtpArbGenPtn[47:40] 165 TxtpArbGenPtn AAh TxtpArbGenPtn[55:48] 166 TxtpArbGenPtn AAh TxtpArbGenPtn[63:56] 167 TxtpArbChkPtn AAh TxtpArbChkPtn[7:0] 168 TxtpArbChkPtn AAh TxtpArbChkPtn[15:8] 169 TxtpArbChkPtn AAh TxtpArbChkPtn[23:16] 170 TxtpArbChkPtn AAh TxtpArbChkPtn[31:24] 171 TxtpArbChkPtn AAh TxtpArbChkPtn[39:32] 172 TxtpArbChkPtn AAh TxtpArbChkPtn[47:40] 173 TxtpArbChkPtn AAh TxtpArbChkPtn[55:48] 42 Reserved VCOCAL[1:0] tpErrAlarm tpSyncLos swReset sqmAlarm dLosEn[1:0] dLOS Reserved Reserved LOS Reserved Reserved FIFOAuto Reset FIFOReset TxphaseAdjust[6:0] Reserved TxSqmValue[5:0] TxSqmThresh[5:0] TxSqmDeassertThresh[5:0] clkOnLOS SquelchOnTxLOL tpChkSel[2:0] Reserved Reserved SquelchOn TxLOS Squelch tpGenInvert Reserved Reserved tpGenSel[2:0] tpSyncMask tpTimeBase[1:0] Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Name Default Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 174 TxtpArbChkPtn AAh TxtpArbChkPtn[63:56] 175 TxtpTargetErr FFh TxtpTargetErr[7:0] 176 TxtpChkErrCnt N/A TxtpChkErrCnt[7:0] 177 TxtpChkErrCnt N/A TxtpChkErrCnt[15:8] 178 TxtpChkErrCnt N/A TxtpChkErrCnt[23:16] 179 TxtpChkErrCnt N/A TxtpChkErrCnt[31:24] 180 TxtpChkErrCnt N/A TxtpChkErrCnt[39:32] 181 TxtpChkErr N/A TxtpChkErr[7:0] 184 OutputLevel F5h 205 TxPDGainAcq 8Dh 226 TxLoopFAcq 1Eh Bit 2 Bit 1 N ot fo R r N ec o ew m m D e es nd ig e ns d Reg HsPowerCtl[1:0] Reserved TxPDGainAcq[2:0] TxLoop FAcqCtl Reserved Reserved Reserved Reserved Bit 0 outLevel[2:0] Reserved Reserved Reserved TxLoopFAcq[6:0] Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 43 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 0. Part Identifier Bit D7 D6 D5 D4 D3 Identifier[7:0] Type R D1 D0 N ot fo R r N ec o ew m m D e es nd ig e ns d Name D2 Reset settings = 0100 0000 Bit Name 7:0 Identifier[7:0] Function Second and least significant digit of the device part number (40). Register 1. Part Identifier Bit D7 D6 D5 D4 D3 D2 D1 Name Revision[3:0] Identifier[3:0] Type R R D0 Reset settings = 0011 0000 Bit Name 7:4 Revision[3:0] Die revision (Revision D = 3 decimal). 3:0 Identifier[3:0] Third digit of the device number (0). 44 Function Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 2. ChipConfig1 D7 D6 D5 D4 D3 D2 D1 D0 Name losOpenDrain intOpenDrain intEnable spiOpenDrain Reserved lineside Loopback XFI Loopback refClkFreq N ot fo R r N ec o ew m m D e es nd ig e ns d Bit Type R/W R/W R/W R/W R/W R/W R/W R/W Reset settings = 0101 1000 Bit Name Function 7 losOpenDrain RX LOS Output Select. 0 = CMOS output. 1 = Open Drain. 6 intOpenDrain Interrupt Pin Drive Select. 0 = CMOS output. 1 = Open Drain. 5 intEnable 4 spiOpenDrain 3 Reserved Do not change. Must only write a 1 to this bit. 2 lineside Loopback Lineside Loopback Mode Control. 0 = Normal operation. 1 = Optical data loopback. 1 XFILoopback 0 refClkFreq Interrupt Enable. 0 = Interrupts disabled. 1 = Interrupts enabled. SD Pin Drive Configuration. 0 = CMOS. 1 = Open Drain. XFI Loopback Mode Control. 0 = Normal operation. 1 = XFI loopback. Reference Clock Frequency Select. 0 = 155 MHz. 1 = 622 MHz. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 45 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 3. RxChipConfig2 Bit D7 D6 D5 D4 D3 D2 D1 Name RxPdn R R R R R R R R/W N ot fo R r N ec o ew m m D e es nd ig e ns d Type D0 Reset settings = 0000 0000 Bit Name 7:1 Reserved 0 RxPdn 46 Function Read returns zero. Receiver Power Down. 0 = Normal operation. 1 = Receiver powered down. A hard recal must be performed to calibrate all circuits (RX hardRecal at Register 8, Bit 3) when the receiver is returned to normal operation after a power down. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 4. RxintMask Bit D7 Name Type D5 D4 D3 refLOS LOS LOL fifoErr R/W R/W R/W R/W D2 D1 tpErrAlarm tpSyncLos R/W R/W D0 sqmAlarm R/W N ot fo R r N ec o ew m m D e es nd ig e ns d R D6 Reset settings = 0000 0000 Bit Name Function 7 Reserved 6 refLOS Reference Clock LOS Interrupt. 0 = Unmasked. Reference clock LOS generates an alarm on the Interrupt output pin (pin 16) if interrupts are enabled. (intEnable = 1) 1 = refLOS alarm is ignored. 5 LOS Loss of Signal Interrupt. 0 = Unmasked. LOS generates an alarm on the Interrupt output (pin 16) if interrupts are enabled. (intEnable = 1) 1 = LOS alarm is ignored. 4 LOL Loss of Lock Interrupt. 0 = Unmasked. LOL generates an alarm on the Interrupt output (pin 16) if interrupts are enabled. (intEnable = 1) 1 = LOL alarm is ignored. 3 fifoErr Receiver FIFO Error Interrupt. 0 = Unmasked. fifoErr generates an alarm on the Interrupt output (pin 16) if interrupts are enabled (intEnable = 1). Will always read back zero if FIFOAutoReset is active (Reg28[1] = 1). 1 = fifoErr alarm is ignored. 2 tpErrAlarm Test Pattern Generator/Checker Alarm Interrupt. 0 = Unmasked. tpErrAlarm generates an alarm on the Interrupt output (pin 16) if interrupts are enabled. (intEnable = 1) 1 = tpErrAlarm is ignored. 1 tpSyncLos Test Pattern Checker Loss of Sync Interrupt. 0 = Unmasked. tpSyncLos generates an alarm on the Interrupt output (pin 16) if interrupts are enabled. (initEnable = 1) 1 = tpSyncLos alarm is ignored. 0 sqmAlarm Signal Quality Monitor Alarm Interrupt. 0 = Unmasked. sqmAlarm generates an alarm on the Interrupt output (pin 16) if interrupts are enabled. (intEnable = 1) 1 = sqmAlarm is ignored. Read returns zero. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 47 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 5. RxintStatus (Sticky Bits) Bit D7 Name R D5 D4 D3 refLOS LOS LOL fifoErr R/W R/W R/W R/W D2 D1 tpErrAlarm tpSyncLos R/W R/W D0 sqmAlarm R/W N ot fo R r N ec o ew m m D e es nd ig e ns d Type D6 Reset settings = 0000 0000 Bit Name 7 Reserved 6 refLOS Reference Clock LOS Interrupt. A latched version of the refLOS alarm status bit. An interrupt is generated if interrupts are enabled (intEnable = 1) and if not masked by the corresponding interrupt mask bit. The interrupt may be cleared by writing a zero to this bit position or by disabling interrupts. 5 LOS Loss of Signal Interrupt. A latched version of the LOS alarm status bit. An interrupt is generated if interrupts are enabled (intEnable = 1) and if not masked by the corresponding interrupt mask bit. The interrupt may be cleared by writing a zero to this bit position or by disabling interrupts. 4 LOL Loss of Lock Interrupt. A latched version of the LOL alarm status bit. An interrupt is generated if interrupts are enabled (intEnable = 1) and if not masked by the corresponding interrupt mask bit. The interrupt may be cleared by writing a zero to this bit position or by disabling interrupts. 3 fifoErr Receiver FIFO Error Interrupt. A latched version of the fifoErr alarm status bit. An interrupt is generated if interrupts are enabled (intEnable = 1) and if not masked by the corresponding interrupt mask bit. The interrupt may be cleared by writing a zero to this bit position or by disabling interrupts. 2 tpErrAlarm Test Pattern Generator/Checker Alarm Interrupt. A latched version of the tpErrAlarm status bit. An interrupt is generated if interrupts are enabled (intEnable = 1) and if not masked by the corresponding interrupt mask bit. The interrupt may be cleared by writing a zero to this bit position or by disabling interrupts. 1 tpSyncLos Test Pattern Checker Loss of Sync Interrupt. A latched version of the tpSyncLos alarm status bit. An interrupt is generated if interrupts are enabled (intEnable = 1) and if not masked by the corresponding interrupt mask bit. The interrupt may be cleared by writing a zero to this bit position or by disabling interrupts. 0 sqmAlarm Signal Quality Monitor Alarm Interrupt. A latched version of the sqmAlarm status bit. An interrupt is generated if interrupts are enabled (intEnable = 1) and if not masked by the corresponding interrupt mask bit. The interrupt may be cleared by writing a zero to this bit position or by disabling interrupts. 48 Function Read returns zero. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 6. RxCmuConfig Bit D7 D6 D5 D4 D3 D2 D1 cmuBandwidth[3:0] Reserved Reserved Type R/W R R/W N ot fo R r N ec o ew m m D e es nd ig e ns d Name D0 Reset settings = 0100 0000 Bit 7:4 Name Function cmuBandwidth[3:0] RxCMU Jitter Transfer Bandwidth. 0000 = Not supported 0001 = Not supported 0010 = Not supported 0011 = Not supported 0100 = 380 kHz Default 0101 = Not supported 0110 = Not supported 3 Reserved Read returns zero. 2:0 Reserved Do not change; must only write 000 to these bits. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 49 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 7. RxConfig Bit D7 Name D5 D4 D3 D2 D1 D0 lolOnLOS ltrOnLOS CDRLTDATA uselolMode lolMode ltr rxRefclkEn R/W R/W R/W R/W R/W R/W R/W R N ot fo R r N ec o ew m m D e es nd ig e ns d Type D6 Reset settings = 0001 0101 Bit Name 7 Reserved Read returns zero. 6 lolOnLOS Loss of Lock on Loss of Signal. 0 = Normal LOL operation. 1 = Assert loss of lock on a loss of signal condition. 5 ltrOnLOS Lock to Reference on Loss of Signal. 0 = Normal LTR operation. 1 = Assert lock to reference on a loss of signal condition. 4 CDRLTDATA 3 uselolMode Loss of Lock Mode Overwrite. 0 = Frequency LOL if RX ltr = 1 and SQM LOL if RX ltr = 0. The LOL mode can be read from the lolmode bit 2. 1 = LOL is based on lolMode bit2. 2 lolMode Loss of Lock Mode (This bit is only used if bit3 = 1). 0 = LOL bases on frequency difference between the reference clock and received data. 1 = LOL bases on SQM. 1 ltr 0 rxRefclkEn 50 Function CDR Lock Acquisition Options when Lock to Reference is enabled. 0 = CDR phase locks to reference clock. 1 = CDR continues to attempt to lock to data. Lock to Reference. 0 = Normal operation. 1 = RX CMU locked to reference clock. Receiver Reference Clock Enable. 0 = Reference clock not used by the receiver (incorrect rate). 1 = Reference clock applied to the receiver. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 8. RxCalConfig Bit D7 D6 D5 D4 Name hardRecal R R R R R/W D2 D1 VCOCAL[1:0] R/W R/W D0 swReset R/W N ot fo R r N ec o ew m m D e es nd ig e ns d Type D3 Reset settings = 0000 0000 Bit Name Function 7:4 Reserved Read returns zero. 3 hardRecal Force Recalibarions. 0 = Normal operation 1 = Initiate all calibrations of internal circuits and do not reset all RX registers. Bit is cleared upon completion of calibrations. 2:1 VCOCAL[1:0] Receive VCO Calibration Modes. 00 (Default) = Automatic detection of the reference clock is enabled. If the reference clock is present and rxRefclkEn (Register 7, bit 0), it will be used to center the internal VCO pull range at the beginning of the lock acquisition process. Otherwise, the entire VCO frequency range will be swept. 01 = Enable referenceless operation. The entire VCO frequency range will be swept during the CDR lock acquisition process regardless of the presence of the reference clock. 10 = Enable reference operation. The internal VCO pull range will be centered with the reference clock frequency. 11 = Invalid mode. Note that receive LOL will always be on. Note: VCOCAL[1:0] must be set to reference (10b) or auto mode (00b) when part is configured to be in XFI loopback mode. Note: When Rx VCOCAL = x0b and a valid reference clock is present and rxRefclkEn = 1 (reg7[0]), registers 77 and 98 must not be written to. See section “5.8.1.1. Dynamic Register Control”. 0 swReset Reset. 0 = Normal operation. 1 = Reset all RX side registers. Bit is cleared upon completion of reset. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 51 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 9. RxAlarmStatus Bit D7 Name Type D5 D4 D3 refLOS LOS LOL fifoErr R R R R D2 D1 tpErrAlarm tpSyncLos R D0 sqmAlarm R R N ot fo R r N ec o ew m m D e es nd ig e ns d R D6 Reset settings = 0000 0000 Bit Name 7 Reserved 6 refLOS 5 LOS Function Read returns zero. Reference Clock LOS Alarm. Loss of signal on the reference clock input, based on a coarse deviation in frequency. Loss of Signal Alarm. Loss of signal on the receiver input. Note: This bit is the logical OR of the Analog LOS (aLOS), Digital LOS (dLOS) and Signal Quality Monitor LOS (sqmLOS) alarms, which can be enabled individually by programming Register 10. 52 4 LOL Loss of Lock Alarm. The receiver PLL has lost lock with the input signal. Reflects the state of the RX_LOL pin (pin 2). 3 fifoErr 2 tpErrAlarm Test Pattern Generator/Checker Alarm. The receiver test pattern checker has reached the predetermined error count set in Register 47. 1 tpSyncLos Test Pattern Checker Loss-of-Sync Alarm. The receiver test pattern checker has lost sync with the pattern. When the test pattern checker is disabled, this bit is automatically set to 0. When the test pattern checker is enabled, an “I” in this location means the test pattern checker has lost synchronization between the expected pattern and the received pattern. 0 sqmAlarm Signal Quality Monitor Alarm. The internal signal quality monitor value has met the predetermined threshold value. Receiver FIFO Error Alarm. The receiver FIFO has overflowed or underflowed. If FIFOAutoReset is active (Reg28[1] = 1), this bit is automatically cleared when a FIFO over/under flow has occurred. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 10. RxLosCtrl Bit D7 D6 D5 D4 Name R R R R D2 D1 D0 sqmLosEn dLosEn[1:0] aLosEn R/W R/W R/W N ot fo R r N ec o ew m m D e es nd ig e ns d Type D3 Reset settings = 0000 0001 Bit Name Function 7:4 Reserved Read returns zero. 3 sqmLosEn Signal Quality Monitor LOS Enable. 0 = Disabled. 1 = Signal Quality Monitor alarm causes an LOS alarm. 2:1 dLosEn[1:0] 0 aLosEn Digital LOS Enable Mode. 00 = Disabled. 01 = Digital LOS alarm is based on the consecutive number of zeros programmed in Register 17. 10 = Digital LOS alarm is based on the consecutive number of ones programmed in Register 17. 11 = Digital LOS alarm is based on the consecutive number of either zeros or ones programmed in Register 17. Analog LOS Enable. 0 = Disabled. 1 = Analog LOS alarm active. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 53 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 11. RxLosStatus Bit D7 D6 D5 Name R R R D3 D2 D1 D0 sqmLOS dLOSlastTrigger dLOS aLOS LOS R R R R R N ot fo R r N ec o ew m m D e es nd ig e ns d Type D4 Reset settings = 0000 0000 Bit Name 7:5 Reserved 4 sqmLOS Function Read returns zero. Signal Quality Monitor LOS. When the internal signal quality monitor (Reg25) is less than the threshold in registers 26 and 27, this bit will be high. If a LOL (Reg9[4]) is high, this bit is forced to a 0. dLOSlastTrigger Digital Loss of Signal Last Trigger. Holds a zero or one depending on which bit caused the last digital LOS event. dLOS Digital Loss of Signal. Digital LOS event status bit. aLOS Analog Loss of Signal. Analog LOS event status bit. LOS Loss of Signal. Reflects the state of the RX_LOS pin (pin 3). 3 2 1 0 Register 12. aLosThresh Bit D7 D6 D5 D4 D3 Name aLosThresh[7:0] Type R/W D2 D1 D0 Reset settings = 0000 1111 Bit Name 7:0 aLosThresh[7:0] Function Analog Loss of Signal Threshold. Lower 8 bits of the analog LOS threshold value in mVppd. Note: Maximum analog LOS threshold is 400 mVppd. 54 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 13. aLosThresh2 Bit D7 D6 D5 D4 D3 D2 D1 D0 aLosHyst[3:0] Reserved aLosThresh[9:8] Type R/W R R/W N ot fo R r N ec o ew m m D e es nd ig e ns d Name Reset settings = 0111 0000 Bit Name 7:4 aLosHyst[3:0] 3:2 Reserved 1:0 aLosThresh[9:8] Function Analog Loss of Signal Hysteresis. Analog LOS deassert value = (aLosHyst + 16)/16 * aLosThresh in mVppd. Read returns zero. Analog Loss of Signal Threshold. Upper two bits of the analog threshold value in mVppd. Notes: 1. Maximum analog LOS threshold is 400 mVppd. 2. Combined with Register 12, 00 0000 1010 = 10 mVppd minimum. 01 1001 0000 = 400 mVppd maximum. Register 15. peakDet Bit D7 D6 D5 D4 D3 Name peakDet[7:0] Type R D2 D1 D0 Reset settings = 0000 0000 Bit Name Function 7:0 peakDet[7:0] Peak Detector Signal Amplitude. Least significant byte of the receiver peak detector signal amplitude in mV. This register should be read before register 16. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 55 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 16. peakDet Bit D7 D6 D5 D4 D3 D2 Name D1 D0 peakDet[1:0] R R N ot fo R r N ec o ew m m D e es nd ig e ns d Type Reset settings = 0000 0000 Bit Name 7:2 Reserved 1:0 peakDet[9:8] Function Read returns zero. Peak Detector Signal Amplitude. Most significant two bits of the receiver peak detector signal amplitude in mV. This register should be read after reading Register 15. Note: Combined with Register 15, 00 0000 0000 = 0 mV 11 1111 1111 = 1022 mV Register 17. RxdLosAssertThresh Bit D7 D6 D5 D4 D3 Name RxdLosAssertThresh[7:0] Type R/W D2 D1 D0 Reset settings = 0000 0101 Bit 7:0 56 Name Function RxdLosAssertThresh[7:0] Receiver Digital Loss of Signal Assert Threshold. The number of consecutive identical digits before digital LOS is asserted. Assert threshold in bits = (RxdLosAssertThresh x 5 + 2) x 1024. See Figure 10 on page 20. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 18. RxdLosClearThresh Bit D7 D6 D5 D4 D3 RxdLosClearThresh[7:0] Type R/W D1 D0 N ot fo R r N ec o ew m m D e es nd ig e ns d Name D2 Reset settings = 0110 0000 Bit 7:0 Name Function RxdLosClearThresh[7:0] Receiver Digital Loss of Signal Clear Threshold. Clear threshold that releases a digital LOS event. The number of consecutive 1024 bit fields with at least one transition that are required to clear dLos is calculated as RxdLos clearthresh x 16 + 1. See Figure 11 on page 21. Register 20. sliceConfig Bit D7 D6 D5 Name Reserved Type R/W D4 D3 D2 D1 D0 sliceEn[2:0] R R/W Reset settings = 0001 0001 Bit Name Function 7:4 Reserved Do not change; must only write 0001 to these bits. 3 Reserved Read returns zero. 2:0 sliceEn[2:0] Slice Mode Enable. 000 = Slice disabled. 001 = Autoslice enabled. 010 = Constant duty cycle slice enabled. 011 = Proportional slice enabled. 100 = Absolute slice mode enabled. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 57 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 21. sliceLvl Bit D7 D6 D5 D4 D3 sliceLvl[7:0] Type R/W D1 D0 N ot fo R r N ec o ew m m D e es nd ig e ns d Name D2 Reset settings = 0000 0000 Bit Name 7:0 sliceLvl[7:0] Function Slice Level. Least significant byte of slice level setting. 2's compliment signed value. Absolute mode: 7FFFH = maximum slice offset = +240 mV 8000H = minimum slice offset = –240 mV Proportional Mode:Threshold = 50% + sliceLvl/65536 x 100 Constant Duty Cycle Mode:7A7AH = maximum duty cycle = ~74% 8586H = minimum duty cycle = ~26% sliceLvl  15:0  Duty Cycle = 50% + --------------------------------------- % 1310 Register 22. sliceLvl Bit D15 D14 D13 D12 D11 Name sliceLvl[15:8] Type R/W D10 D9 D8 Reset settings = 0000 0000 Bit Name 15:8 sliceLvl[15:8] Function Slice Level. Most significant byte of slice level setting. 2s compliment signed value. Absolute mode: 7FFFH = maximum slice offset = +240 mV 8000H = minimum slice offset = –240 mV Proportional Mode:Threshold = 50% + sliceLvl/65536 x 100 Constant Duty Cycle Mode:7A7AH = maximum duty cycle = ~74% 8586H = minimum duty cycle = ~26% sliceLvl  15:0  Duty Cycle = 50% + --------------------------------------- % 1310 Note: The slice level defined by Register 22 and 21 gets updated together after Register 21, the least significant byte of the 16-bit field, has been written. Prior to writing Register 21, the value written to Register 22 is stored into a mirroring register first. Any read to Register 22 prior to writing Register 21 will not return the intended value. 58 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 24. RxphaseAdjust Bit D7 D6 D5 D4 Name D2 D1 D0 RxphaseAdjust[6:0] R R/W N ot fo R r N ec o ew m m D e es nd ig e ns d Type D3 Reset settings = 0000 0000 Bit Name 7 Reserved 6:0 Function Read returns zero. RxphaseAdjust[6:0] Receiver Phase Adjust. Programmable range will cover at least –12 to 12 ps. The transfer function from Register 24 to the actual picoseconds of phase shift is highly variable. Value is signed, in 2s complement format: 100 0001 < –12 ps 011 1111 > 12 ps Register 25. RxSqmValue Bit D7 D6 D5 Name D4 D3 D2 D1 D0 RxSqmValue[5:0] Type R R Reset settings = undefined Bit Name 7:6 Reserved 5:0 Function Read returns zero. RxSqmValue[5:0] Receiver Signal Quality Monitor Value. Measured value of the magnitude of the received signal's horizontal eye opening. 00 0000 = minimum 11 1111 = maximum Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 59 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 26. RxSqmConfig Bit D7 D6 D5 D4 RxSqmThresh[5:0] Type R/W D2 D1 D0 R/W R/W D1 D0 N ot fo R r N ec o ew m m D e es nd ig e ns d Name D3 Reset settings = 0010 1001 Bit 7:2 Name Function RxSqmThresh[5:0] Receiver Signal Quality Monitor Threshold. Threshold used to assert SQM LOS alarm. 00 0000 = 0 (decimal) 11 1111 = 63 (decimal) Note: Default = 10 (decimal) 1 Reserved Do not change; must only write 0 to this bit. 0 Reserved Do not change; must only write 1 to this bit. Register 27. RxSqmDeassertThresh Bit D7 D6 D5 D4 Name Type D3 D2 RxSqmDeassertThresh[5:0] R R/W Reset settings = 0000 1111 Bit Name 7:6 Reserved 5:0 Function Read returns zero. RxSqmDeassertThresh[5:0] Receiver Signal Quality Monitor Deassert Threshold. Value where the SQM alarm is removed. 00 0000 = 0 (decimal) 11 1111 = 63 (decimal) Note: Default = 15 (decimal) 60 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 28. RxdPathConfig Bit D7 dinvert D5 D4 D3 clkOnLOS SquelchO- SquelchOnRxLOL nRxLOS D2 D1 D0 Squelch FIFOAuto Reset FIFOReset N ot fo R r N ec o ew m m D e es nd ig e ns d Name D6 Type R R/W R/W R/W R/W R/W R/W R/W Reset settings = 0000 0010 Bit Name 7 Reserved 6 dinvert 5 clkOnLOS Function Read returns zero. Data Invert. 0 = Normal operation. 1 = RD+ and RD– outputs (pins 19, 18) inverted. Clock Output on Receive Loss of Signal. 0 = Normal operation. 1 = 622 MHz clock output on RD+ and RD– on receiver LOS condition. 4 SquelchOnRxLOL Data Squelch on Receive Loss of Lock. 0 = Normal operation. 1 = Squelch RD+ and RD– outputs (pins 19, 18) on receiver Loss of Lock condition. 3 SquelchOnRxLOS Data Squelch on Receive Loss of Signal. 0 = Normal operation. 1 = Squelch RD+ and RD– outputs (pins 19, 18) on receiver Loss of Signal condition. 2 Squelch 1 FIFOAutoReset 0 FIFOReset Data Squelch. 0 = Normal operation. 1 = Squelch RD+ and RD– outputs (pins 19, 18). FIFO Auto Reset. 0 = No reset of receive FIFO on FIFO error. 1 = Automatically reset receive FIFO on FIFO underflow or overflow and clear fifoerr bit in RXintMask register (Reg4[1]). FIFO pointer is reset to center value and FIFO is cleared. FIFO Reset. 0 = Normal operation. 1 = Reset receive FIFO. FIFO pointer is reset to center value and FIFO is cleared. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 61 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 29. RxtpSel D7 D6 D5 D4 D3 D2 D1 Name tpChkInvert tpChkSel[2:0] tpGenInvert tpGenSel[2:0] Type R/W R/W R/W R/W D0 N ot fo R r N ec o ew m m D e es nd ig e ns d Bit Reset settings = 0000 0000 Bit Name 7 tpChkInvert 6:4 tpChkSel[2:0] 3 tpGenInvert 2:0 tpGenSel[2:0] Function Test Pattern Checker Data Invert. 0 = Normal operation. 1 = Invert data applied to test pattern checker. Test Pattern Checker Mode Select. 000 = Pattern checker disabled. 001 = Check for PRBS7 pattern. 010 = Check for PRBS31 pattern. 011 = Check for 64 bit user defined pattern. Test Pattern Generator Data Invert. 0 = Normal operation. 1 = Invert generated pattern. Test Pattern Generator Mode Select. 000 = Pattern generator disabled. 001 = Generate PRBS7 pattern. 010 = Generate PRBS31 pattern. 011 = Generate 64 bit user defined pattern. Notes: 1. Users cannot switch from generating PRBS31 to PRBS7 directly. tpGenSel should be set to 000 (pattern generator disabled) before switching to PRBS7. Note that this only applies to switching from PRBS31 to PRBS7. 2. The PRBS31pattern is inverted as per Section 5.8 of O.150. 62 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 30. RxtpChkConfig Bit D7 D6 D5 D4 D3 D2 Name Type D1 D0 tpSyncMask tpTimeBase[1:0] R/W R/W N ot fo R r N ec o ew m m D e es nd ig e ns d R Reset settings = 0000 0010 Bit Name 7:3 2 Reserved tpSyncMask 1:0 Function Read returns zero. Test Pattern Checker Sync Mask. 0 = Normal operation. 1 = After synchronization has been achieved a loss of sync will not be reported and the pattern checker will not be reset. tpTimeBase[1:0] Test Pattern Checker Timebase. The time or number of bits over which the pattern will be checked. 00 = continuous (infinite). 01 = (220 – 1024) bits 10 = (230 – 1024) bits 11 = (240 – 1024) bits Register 31. RxtpArbGenPtn Bit D7 D6 D5 D4 D3 Name RxtpArbGenPtn[7:0] Type R/W D2 D1 D0 Reset settings = 1010 1010 Bit 7:0 Name Function RxtpArbGenPtn[7:0] Receiver Test Pattern Generator User Defined Pattern. Note: Bit 0 in Register 31 is the LSB of the 64-bit user-defined pattern, and Bit 7 in Register 38 is the MSB. The transmit sequence is from LSB to MSB. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 63 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 32. RxtpArbGenPtn Bit D15 D14 D13 D12 D11 RxtpArbGenPtn[15:8] Type R/W D9 D8 N ot fo R r N ec o ew m m D e es nd ig e ns d Name D10 Reset settings = 1010 1010 Bit 7:0 Name Function RxtpArbGenPtn[15:8] Receiver Test Pattern Generator User Defined Pattern. Note: Bit 0 in Register 31 is the LSB of the 64-bit user-defined pattern, and Bit 7 in Register 38 is the MSB. The transmit sequence is from LSB to MSB. Register 33. RxtpArbGenPtn Bit D23 D22 D21 D20 D19 Name RxtpArbGenPtn[23:16] Type R/W D18 D17 D16 Reset settings = 1010 1010 Bit 7:0 Name Function RxtpArbGenPtn[23:16] Receiver Test Pattern Generator User Defined Pattern. Note: Bit 0 in Register 31 is the LSB of the 64-bit user-defined pattern, and Bit 7 in Register 38 is the MSB. The transmit sequence is from LSB to MSB. Register 34. RxtpArbGenPtn Bit D31 D30 D29 D28 D27 Name RxtpArbGenPtn[31:24] Type R/W D26 D25 D24 Reset settings = 1010 1010 Bit 7:0 Name Function RxtpArbGenPtn[31:24] Receiver Test Pattern Generator User Defined Pattern. Note: Bit 0 in Register 31 is the LSB of the 64-bit user-defined pattern, and Bit 7 in Register 38 is the MSB. The transmit sequence is from LSB to MSB. 64 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 35. RxtpArbGenPtn Bit D39 D38 D37 D36 D35 RxtpArbGenPtn[39:32] Type R/W D33 D32 N ot fo R r N ec o ew m m D e es nd ig e ns d Name D34 Reset settings = 1010 1010 Bit 7:0 Name Function RxtpArbGenPtn[39:32] Receiver Test Pattern Generator User Defined Pattern. Note: Bit 0 in Register 31 is the LSB of the 64-bit user-defined pattern, and Bit 7 in Register 38 is the MSB. The transmit sequence is from LSB to MSB. Register 36. RxtpArbGenPtn Bit D47 D46 D45 D44 D43 Name RxtpArbGenPtn[47:40] Type R/W D42 D41 D40 Reset settings = 1010 1010 Bit 7:0 Name Function RxtpArbGenPtn[47:40] Receiver Test Pattern Generator User Defined Pattern. Note: Bit 0 in Register 31 is the LSB of the 64-bit user-defined pattern, and Bit 7 in Register 38 is the MSB. The transmit sequence is from LSB to MSB. Register 37. RxtpArbGenPtn Bit D55 D54 D53 D52 D51 Name RxtpArbGenPtn[55:48] Type R/W D50 D49 D48 Reset settings = 1010 1010 Bit 7:0 Name Function RxtpArbGenPtn[55:48] Receiver Test Pattern Generator User Defined Pattern. Note: Bit 0 in Register 31 is the LSB of the 64-bit user-defined pattern, and Bit 7 in Register 38 is the MSB. The transmit sequence is from LSB to MSB. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 65 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 38. RxtpArbGenPtn Bit D63 D62 D61 D60 D59 RxtpArbGenPtn[63:56] Type R/W D57 D56 N ot fo R r N ec o ew m m D e es nd ig e ns d Name D58 Reset settings = 1010 1010 Bit 7:0 Name Function RxtpArbGenPtn[63:56] Receiver Test Pattern Generator User Defined Pattern. Note: Bit 0 in Register 31 is the LSB of the 64-bit user-defined pattern, and Bit 7 in Register 38 is the MSB. The transmit sequence is from LSB to MSB. Register 39. RxtpArbChkPtn Bit D7 D6 D5 D4 D3 Name RxtpArbChkPtn[7:0] Type R/W D2 D1 D0 Reset settings = 1010 1010 Bit 7:0 Name Function RxtpArbChkPtn[7:0] Receiver Test Pattern Checker User Defined Pattern. Note: Bit 0 in Register 39 is the LSB of the received 64-bit user-defined pattern, and Bit 7 in Register 46 is the MSB. The receive sequence is from LSB to MSB. Register 40. RxtpArbChkPtn Bit D15 D14 D13 D12 D11 Name RxtpArbChkPtn[15:8] Type R/W D10 D9 D8 Reset settings = 1010 1010 Bit 7:0 Name Function RxtpArbChkPtn[15:8] Receiver Test Pattern Checker User Defined Pattern. Note: Bit 0 in Register 39 is the LSB of the received 64-bit user-defined pattern, and Bit 7 in Register 46 is the MSB. The receive sequence is from LSB to MSB. 66 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 41. RxtpArbChkPtn Bit D23 D22 D21 D20 D19 RxtpArbChkPtn[23:16] Type R/W D17 D16 N ot fo R r N ec o ew m m D e es nd ig e ns d Name D18 Reset settings = 1010 1010 Bit 7:0 Name Function RxtpArbChkPtn[23:16] Receiver Test Pattern Checker User Defined Pattern. Note: Bit 0 in Register 39 is the LSB of the received 64-bit user-defined pattern, and Bit 7 in Register 46 is the MSB. The receive sequence is from LSB to MSB. Register 42. RxtpArbChkPtn Bit D31 D30 D29 D28 D27 Name RxtpArbChkPtn[31:24] Type R/W D26 D25 D24 Reset settings = 1010 1010 Bit 7:0 Name Function RxtpArbChkPtn[31:24] Receiver Test Pattern Checker User Defined Pattern. Note: Bit 0 in Register 39 is the LSB of the received 64-bit user-defined pattern, and Bit 7 in Register 46 is the MSB. The receive sequence is from LSB to MSB. Register 43. RxtpArbChkPtn Bit D39 D38 D37 D36 D35 Name RxtpArbChkPtn[39:32] Type R/W D34 D33 D32 Reset settings = 1010 1010 Bit 7:0 Name Function RxtpArbChkPtn[39:32] Receiver Test Pattern Checker User Defined Pattern. Note: Bit 0 in Register 39 is the LSB of the received 64-bit user-defined pattern, and Bit 7 in Register 46 is the MSB. The receive sequence is from LSB to MSB. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 67 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 44. RxtpArbChkPtn Bit D47 D46 D45 D44 D43 RxtpArbChkPtn[47:40] Type R/W D41 D40 N ot fo R r N ec o ew m m D e es nd ig e ns d Name D42 Reset settings = 1010 1010 Bit 7:0 Name Function RxtpArbChkPtn[47:40] Receiver Test Pattern Checker User Defined Pattern. Note: Bit 0 in Register 39 is the LSB of the received 64-bit user-defined pattern, and Bit 7 in Register 46 is the MSB. The receive sequence is from LSB to MSB. Register 45. RxtpArbChkPtn Bit D55 D54 D53 D52 D51 Name RxtpArbChkPtn[55:48] Type R/W D50 D49 D48 Reset settings = 1010 1010 Bit 7:0 Name Function RxtpArbChkPtn[55:48] Receiver Test Pattern Checker User Defined Pattern. Note: Bit 0 in Register 39 is the LSB of the received 64-bit user-defined pattern, and Bit 7 in Register 46 is the MSB. The receive sequence is from LSB to MSB. Register 46. RxtpArbChkPtn Bit D63 D62 D61 D60 D59 Name RxtpArbChkPtn[63:56] Type R/W D58 D57 D56 Reset settings = 1010 1010 Bit 7:0 Name Function RxtpArbChkPtn[63:56] Receiver Test Pattern Checker User Defined Pattern. Note: Bit 0 in Register 39 is the LSB of the received 64-bit user-defined pattern, and Bit 7 in Register 46 is the MSB. The receive sequence is from LSB to MSB. 68 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 47. RxtpTargetErr Bit D7 D6 D5 D4 D3 RxtpTargetErr[7:0] Type R/W D1 D0 N ot fo R r N ec o ew m m D e es nd ig e ns d Name D2 Reset settings = 1111 1111 Bit Name 7:0 Function RxtpTargetErr[7:0] Receiver Test Pattern Checker Target Error Count. If the value in the RxtpChkErrCnt register (register 53) exceeds this target error count, an interrupt will be generated. The value is represented as an 8-bit floating point number. Mantissa = bits[7:4] Exponent = bits[3:0] Error count = (Mantissa/16) x 16Exponent 0000 0000 = 0 (decimal) 1111 1111 = (15/16) x 1615 (decimal) Note: This register value does not represent a target bit error rate (BER). Rather, it is a target bit error count for the period defined by tpTimeBase[1:0]. Register 48. RxtpChkErrCnt (LSB of a 40-bit Register) Bit D7 D6 D5 D4 D3 Name RxtpChkErrCnt[7:0] Type R D2 D1 D0 Reset settings = undefined Bit 7:0 Name Function RxtpChkErrCnt[7:0] Receiver Test Pattern Checker Error Count. When using a defined timebase, this register holds the error count from the last completed timebase. In the continuous timebase setting, the register holds the current running error count. Reading the least significant byte (LSB) latches the upper bytes. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 69 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 49. RxtpChkErrCnt (40-bit Register) Bit D15 D14 D13 D12 D11 RxtpChkErrCnt[15:8] Type R D9 D8 N ot fo R r N ec o ew m m D e es nd ig e ns d Name D10 Reset settings = undefined Bit 7:0 Name Function RxtpChkErrCnt[15:8] Receiver Test Pattern Checker Error Count. When using a defined timebase, this register holds the error count from the last completed timebase. In the continuous timebase setting, the register holds the current running error count. Reading the least significant byte latches the upper bytes. Register 50. RxtpChkErrCnt (40-bit Register) Bit D23 D22 D21 D20 D19 Name RxtpChkErrCnt[23:16] Type R D18 D17 D16 Reset settings = undefined Bit 7:0 Name Function RxtpChkErrCnt[23:16] Receiver Test Pattern Checker Error Count. When using a defined timebase, this register holds the error count from the last completed timebase. In the continuous timebase setting, the register holds the current running error count. Reading the least significant byte latches the upper bytes. Register 51. RxtpChkErrCnt (40-bit Register) Bit D31 D30 D29 D28 D27 Name RxtpChkErrCnt[31:24] Type R D62 D25 D24 Reset settings = undefined Bit 7:0 70 Name Function RxtpChkErrCnt[31:24] Receiver Test Pattern Checker Error Count. When using a defined timebase, this register holds the error count from the last completed timebase. In the continuous timebase setting, the register holds the current running error count. Reading the least significant byte latches the upper bytes. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 52. RxtpChkErrCnt (MSB of a 40-bit Register) Bit D39 D38 D37 D36 D35 RxtpChkErrCnt[39:32] Type R D33 D32 N ot fo R r N ec o ew m m D e es nd ig e ns d Name D34 Reset settings = undefined Bit Name 7:0 Function RxtpChkErrCnt[39:32] Receiver Test Pattern Checker Error Count. When using a defined timebase, this register holds the error count from the last completed timebase. In the continuous timebase setting, the register holds the current running error count. Reading the least significant byte latches the upper bytes. Note: Combined registers 48 to 52, 0000000000 = 0 (decimal) FFFFFFFFFF = 240 – 1 (decimal) Register 53. RxtpChkErr Bit D7 D6 D5 D4 D3 Name RxtpChkErr[7:0] Type R D2 D1 D0 Reset settings = undefined Bit 7:0 Name Function RxtpChkErr[7:0] Receiver Test Pattern Checker Error. Measured error count in 8-bit floating point notation. The contents of this register are an alternative format to the RxtpChkErrCnt. Mantissa = bits [7:4] Exponent = bits [3:0] Error count = (Mantissa/16) x 16Exponent 0000 0000 = 0 (decimal) 1111 1111 = (15/16) x 1615 (decimal) Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 71 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 56. OutputLevel Bit D7 D6 Reserved Type R/W D4 D3 D2 D1 D0 outLevel[2:0] Reserved R/W N ot fo R r N ec o ew m m D e es nd ig e ns d Name D5 Reset settings = 1111 0101 Bit Name Function 7:6 Reserved Do not change; must only write 11 to these bits. 5:3 Reserved These bits are not user defined, and writes to these bits are ignored. 2:0 outLevel[2:0] RD output drive level. 000 = 100 mVppd 001 = 200 mVppd 010 = 300 mVppd 011 = 400 mVppd 100 = 500 mVppd 101 = 600 mVppd 110 = 700 mVppd 111 = 800 mVppd Register 77. RxPDGainAcq Bit D7 D6 D5 D4 D3 D2 Name RxPDGainAcq[2:0] Reserved Type R/W R/W D1 D0 Reset Settings = 1000 1101 72 Bit Name 7:5 RxPDGainAcq[2:0] 4:0 Reserved Function RX phase detector gain during acquisition. Note that these bits require a one time write of 000b after a power up or a software reset. Reserved; must only write 01101b to these bits. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 84. RxEqConfig1 Bit D7 D6 D5 D4 D3 D2 RxEqGain Reserved Type R/W R/W D0 N ot fo R r N ec o ew m m D e es nd ig e ns d Name D1 Reset settings = 1010 0001 Bit Name Function 7:5 RxEqGain Low-Frequency Gain in the Receiver Equalizer Frequency Response. 000 0 dB (max gain) 001 –2 dB 010 –2 dB (same as 001 setting) 011 –3 dB 100 –4 dB 101 –5 dB 110 –6 dB 111 –7 dB (min gain) 4:0 Reserved Do not change; must only write 00001 to these bits. Register 85. RxEqConfig2 Bit D7 D6 D5 D4 D3 D2 Name RxEqHFBoost Reserved Type R/W R/W D1 D0 Reset settings = 1110 0000 Bit Name 7:5 RxEqHFBoost 4:0 Reserved Function High-Frequency Boost in the Receiver Equalizer Frequency Response. 000 0 dB (min boost setting) 001 1 dB 010 2 dB 011 3 dB 100 4 dB 101 5 dB 110 6 dB 111 7 dB (max boost setting) Do not change; must only write 00000 to these bits. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 73 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 98. RxLoopFAcq D7 D6 D5 D4 D3 Name RxLoopFAcqCtl RxLoopFAcq[6:0] Type R/W R/W D2 D1 N ot fo R r N ec o ew m m D e es nd ig e ns d Bit D0 Reset settings = 0001 1110 Bit Name 7 RxLoopFAcqCtl 6:0 RxLoopFAcq[6:0] Function RX Acquistion Loop Filter Override. 1 = Use value written in Bit [6:0]. Set to 1 only when RX LOL is asserted. 0 = Use internally generated value. Set to 0 when RX LOL is deasserted. RX Loop Filter Setting for Acquisition. RX Loop filter override setting to be used during acquisiton. Set to 001 1000b when RX LOL is asserted and to 000 0000b when RX LOL is deasserted. Note that any read back may not return the last written value. Register 106. sqmLOLThreshWrt Bit D7 D6 D5 D4 D3 D2 Name sqmLOLThreshWrt Reserved sqmLOLThreshAdd[5:0] Type R/W R/W R/W D1 D0 Reset settings = 0000 0000 Bit 7 74 Name Function sqmLOLThreshWrt Self-clearning strobe bit to apply sqmLOL Threshold from registers 107,108,109. This is an indexing address register and requires the sqmLOL threshold address to be set before writing data in the appropriate indexed data registers. For this reason, it must first be written to 04h, followed by 84h. Refer to Section 5.8.1 for more information about this register. 6 Reserved 5:0 sqmLOL ThreshAdd[5:0] Do not change; must only write 0 to this bit. Address for sqmLOL Threshold. Must be set to 4. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 107. sqmLOLThresh D7 D6 D5 D4 D3 Name sqmLOLThresh[0] Reserved Type R/W R/W D2 D1 N ot fo R r N ec o ew m m D e es nd ig e ns d Bit D0 Reset settings = 0000 0000 Bit 7 Name Function sqmLOLThresh[0] SQM LOL Threshold. Least significant bit of 14 bit SQM LOL Threshold setting; value is unsigned integer value. RxLOL is asserted when jitter measure exceeds value in sqmLOLThresh[13:0] and is deasserted when jitter measure is below the threshold. Refer to "5.8.1. SQM LOL" on page 24 for more information about this register. 6:0 Reserved Reserved. Should be written to 010 0000b. Register 108. sqmLOLThresh Bit D7 Name Type D6 D5 D4 D3 D2 D1 D0 sqmLOLThresh[8:1] R/W R/W Reset settings = 0000 0000 Bit 7:0 Name Function sqmLOLThresh[8:1] SQM LOL Threshold. Bit [8:1] of sqmLOL Threshold setting; value is unsigned integer value. RxLOL is asserted when jitter measure exceeds value in sqmLOLThresh[13:0] and is deasserted when jitter measure is below the threshold. Refer to Section 5.8.1 for more information about this register. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 75 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 109. sqmLOLThresh Bit D7 D6 D5 D4 D3 D2 D1 Reserved sqmLOLThresh[13:9] Type R/W R/W N ot fo R r N ec o ew m m D e es nd ig e ns d Name D0 Reset settings = 0000 0000 Bit Name 7:5 Reserved 4:0 Function Reserved. Should be written to 101b. sqmLOLThresh[13:9] SQM LOL Threshold. Bit [13:9] of sqmLOL Threshold setting; value is unsigned integer value. RxLOL is asserted when jitter measure exceeds value in sqmLOLThresh[13:0] and is deasserted when jitter measure is below the threshold. Refer to Section 5.8.1 for more information about this register. Register 131. TxChipConfig2 Bit D7 D6 D5 D4 D3 Name Type R R/W D2 D1 D0 Reserved TxPdn R R/W Reset settings = 0010 0010 Bit Name 7 Reserved Read returns zero. 6:1 Reserved Do not change; must only write 010001 to these bits. 0 TxPdn 76 Function Transmitter Power Down. 0 = Normal operation. 1 = Transmitter powered down. A hard recal must be performed to calibrate all circuits (TX hardRecal at Register 136, Bit 3) when the transmitter is returned to normal operation after a power down. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 132. TxintMask Bit D7 Name R D5 D4 D3 refLOS LOS LOL fifoErr R/W R/W R/W R/W D2 D1 tpErrAlarm tpSyncLos R/W R/W D0 sqmAlarm R/W N ot fo R r N ec o ew m m D e es nd ig e ns d Type D6 Reset settings = 0000 0000 Bit Name Function 7 Reserved 6 refLOS Reference Clock LOS Interrupt. 0 = Unmasked. Reference clock LOS generates an alarm on the Interrupt output pin (pin 12) if interrupts are enabled. (intEnable = 1). 1 = refLOS alarm is ignored. 5 LOS Loss of Signal Interrupt. 0 = Unmasked. LOS generates an alarm on the Interrupt output pin (pin 12) if interrupts are enabled. (intEnable = 1). 1 = LOS alarm is ignored. 4 LOL Loss of Lock Interrupt. 0 = Unmasked. LOL generates an alarm on the Interrupt output pin (pin 12) if interrupts are enabled. (intEnable = 1). 1 = LOL alarm is ignored. 3 fifoErr Transmitter FIFO Error Interrupt. 0 = Unmasked. fifoErr generates an alarm on the Interrupt output pin (pin 12) if interrupts are enabled. (intEnable = 1). Will always read back zero if FIFOAutoReset is active (Reg156[1] = 1). 1 = fifoErr alarm is ignored. 2 tpErrAlarm Test Pattern Generator/Checker Alarm Interrupt. 0 = Unmasked. tpErrAlarm generates an alarm on the Interrupt output pin (pin 12) if interrupts are enabled. (intEnable = 1). 1 = tpErrAlarm is ignored. 1 tpSyncLos Test Pattern Checker Loss of Sync Interrupt. 0 = Unmasked. tpSyncLos generates an alarm on the Interrupt output pin (pin 12) if interrupts are enabled. (initEnable = 1). 1 = tpSyncLos alarm is ignored. 0 sqmAlarm Signal Quality Monitor Alarm Interrupt. 0 = Unmasked. sqmAlarm generates an alarm on the Interrupt output pin (pin 12) if interrupts are enabled. (intEnable = 1). 1 = sqmAlarm is ignored. Read returns zero. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 77 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 133. TxintStatus (Sticky Bits) Bit D7 Name R D5 D4 D3 refLOS LOS LOL fifoErr R/W R/W R/W R/W D2 D1 tpErrAlarm tpSyncLos R/W R/W D0 sqmAlarm R/W N ot fo R r N ec o ew m m D e es nd ig e ns d Type D6 Reset settings = 0000 0000 Bit Name 7 Reserved 6 refLOS Reference Clock LOS Interrupt. A latched version of the refLOS alarm status bit. An interrupt is generated if interrupts are enabled (intEnable = 1) and if not masked by the corresponding interrupt mask bit. The interrupt may be cleared by writing a zero to this bit position or by disabling interrupts. 5 LOS Loss of Signal Interrupt. A latched version of the LOS alarm status bit. An interrupt is generated if interrupts are enabled (intEnable = 1) and if not masked by the corresponding interrupt mask bit. The interrupt may be cleared by writing a zero to this bit position or by disabling interrupts. 4 LOL Loss of Lock Interrupt. A latched version of the LOL alarm status bit. An interrupt is generated if interrupts are enabled (intEnable = 1) and if not masked by the corresponding interrupt mask bit. The interrupt may be cleared by writing a zero to this bit position or by disabling interrupts. 3 fifoErr Transmitter FIFO Error Interrupt. A latched version of the fifoErr alarm status bit. An interrupt is generated if interrupts are enabled (intEnable = 1) and if not masked by the corresponding interrupt mask bit. The interrupt may be cleared by writing a zero to this bit position or by disabling interrupts. 2 tpErrAlarm Test Pattern Generator/Checker Alarm Interrupt. A latched version of the tpErrAlarm status bit. An interrupt is generated if interrupts are enabled (intEnable = 1) and if not masked by the corresponding interrupt mask bit. The interrupt may be cleared by writing a zero to this bit position or by disabling interrupts. 1 tpSyncLos Test Pattern Checker Loss of Sync Interrupt. A latched version of the tpSyncLos alarm status bit. An interrupt is generated if interrupts are enabled (intEnable = 1) and if not masked by the corresponding interrupt mask bit. The interrupt may be cleared by writing a zero to this bit position or by disabling interrupts. 0 sqmAlarm Signal Quality Monitor Alarm Interrupt. A latched version of the sqmAlarm status bit. An interrupt is generated if interrupts are enabled (intEnable = 1) and if not masked by the corresponding interrupt mask bit. The interrupt may be cleared by writing a zero to this bit position or by disabling interrupts. 78 Function Read returns zero. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 134. TxCmuConfig Bit D7 D6 D5 cmuBandwidth[3:0] Type R/W D3 D2 D1 D0 cmuMode[2:0] R R/W N ot fo R r N ec o ew m m D e es nd ig e ns d Name D4 Reset settings = 0100 0000 Bit 7:4 Name Function cmuBandwidth[3:0] TxCMU Jitter Transfer Bandwidth. 0000 = 180 Hz Valid for CMU modes 2 and 6. 0001 = 1.37 kHz Valid for CMU modes 2 and 6. 0010 Not supported. 0011 Not supported. 0100 = 380 kHz Valid for CMU modes 0 and 1 only. 0101 Not supported. 0110 Not supported. Note: A manual recalibration (hardRecal = 1 in Register 8) is required after a change in the CMU jitter transfer bandwidth. 3 Reserved 2:0 cmuMode[2:0] Read returns zero. CMU Mode of Operation. 000 = Referenceless Mode. 001 = Synchronous Reference Clock Mode (This is logically the same as setting the ltr bit (register135[1])). 010 = Asynchronous Reference Clock Mode. 110 = Looptime Mode with Clean Reference Clock. (Recommended CMU bandwidth = 1.37 kHz.) Note: An automatic recalibration is executed after a change in timing mode. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 79 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 135. TxConfig Bit D7 D6 D5 Name D3 D2 D1 CDRLTDATA uselolMode lolMode ltr R/W N ot fo R r N ec o ew m m D e es nd ig e ns d Type D4 D0 R Reset settings = 1001 0100 Bit Name 7:5 Reserved 4 CDRLTDATA 3 uselolMode Loss of Lock Mode Overwrite. 0 = Auto select LOL mode is based upon the tx CMU mode. The selected LOL mode can be read from the LOL mode bit 2. 1 = LOL is based on lolMode bit2. 2 lolMode Loss of Lock Mode (This bit is only used if bit3 = 1). 0 = LOL bases on frequency difference between the reference clock and received data. 1 = LOL bases on SQM. 1 ltr 0 Reserved 80 Function Do not change; must only write 100 to these bits. CDR Lock Acquisition Options when Lock to Reference is Enabled. 0 = CDR phase locks to reference clock. 1 = CDR continues to attempt to lock to data. Lock to Reference. 0 = Normal operation. 1 = CMU is locked to reference clock. Read returns zero. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 136. TxCalConfig Bit D7 D6 D5 D4 Name hardRecal R R R R R/W D2 D1 VCOCAL[1:0] R/W R/W D0 swReset R/W N ot fo R r N ec o ew m m D e es nd ig e ns d Type D3 Reset settings = 0000 0000 Bit Name Function 7:4 Reserved Read returns zero. 3 hardRecal Force Recalibrations. 0 = Normal operation 1 = Initiate all calibrations of internal circuits and do not reset all TX registers. Bit is cleared upon completion of calibrations. 2:1 VCOCAL[1:0] Transmit VCO Calibration Modes. 00 = (Default) Automatic detection of the reference clock is enabled. If the reference clock is present, it will be used to center the internal VCO pull range at the beginning of the lock acquisition process. Otherwise, the entire VCO frequency range will be swept. 01 = Enable referenceless operation. The entire VCO frequency range will be swept during the CDR lock acquisition process regardless of the presence of the reference clock. 10 = Enable reference operation. The internal VCO pull range will be centered with the reference clock frequency. 11 = Invalid mode. Note that transmit LOL will always be on. Note: VCOCAL[1:0] must be set to reference(10b) or auto mode (00b) when part is configured to be in Lineside loopback mode. Note: When Tx VCOCAL = x0b and a valid reference clock is present, registers 205 and 226 must not be written to. See section “6.4.1.1. Dynamic Register Control”. 0 swReset Software Reset. 0 = Normal operation. 1 = Reset all TX side registers. Bit is cleared upon completion of reset. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 81 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 137. TxAlarmStatus Bit D7 Name R D5 D4 D3 refLOS LOS LOL fifoErr R R R R D2 D1 tpErrAlarm tpSyncLos R D0 sqmAlarm R R N ot fo R r N ec o ew m m D e es nd ig e ns d Type D6 Reset settings = 0000 0000 Bit Name 7 Reserved 6 refLOS 5 LOS Loss of Signal Alarm. Loss of signal on the transmitter input. (TD) 4 LOL Loss of Lock Alarm. The transmitter PLL has lost lock with the transmitter input signal. (TD) 3 fifoErr 2 tpErrAlarm Test Pattern Generator/Checker Alarm. The transmitter test pattern checker has reached the predetermined error count set in Register 175. 1 tpSyncLos Test Pattern Checker Loss-of-Sync Alarm. The receiver test pattern checker has lost sync with the pattern. When the test pattern checker is disabled, this bit is automatically set to 0. When the test pattern checker is enabled, an “I” in this location means the test pattern checker has lost synchronization between the expected pattern and the received pattern. 0 sqmAlarm Signal Quality Monitor Alarm. The internal signal quality monitor value has met the predetermined threshold value. 82 Function Read returns zero. Reference Clock LOS Alarm. Loss of signal on the reference clock input, based on a coarse deviation in frequency. Transmitter FIFO Error Alarm. The transmitter FIFO has overflowed or underflowed. If FIFOAutoReset is active (Reg156[1] = 1), this bit is automatically cleared when a FIFO over/under flow has occurred. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 138. TxLosCtrl Bit D7 D6 D5 D4 Name R D2 D1 sqmLosEn dLosEn[1:0] R/W R/W D0 R N ot fo R r N ec o ew m m D e es nd ig e ns d Type D3 Reset settings = 0000 1110 Bit Name Function 7:4 Reserved Read returns zero. 3 sqmLosEn Signal Quality Monitor LOS Enable. 0 = Disabled. 1 = Signal Quality Monitor alarm causes an LOS alarm. 2:1 dLosEn[1:0] 0 Reserved Digital LOS Enable Mode. 00 = Disabled. 01 = Digital LOS alarm is based on the consecutive number of zeros programmed in Register 145. 10 = Digital LOS alarm is based on the consecutive number of either zeros or ones programmed in Register 145. 11 = Digital LOS alarm is based on the consecutive number of either zeros or ones programmed in Register 145. Read returns zero. Register 139. TxLosStatus Bit D7 D6 D5 Name Type R R R D4 D3 D2 sqmLOS dLOSlastTrigger dLOS R R R D1 D0 LOS R R Reset settings = 0000 0000 Bit Name 7:5 Reserved Read returns zero. 4 sqmLOS Signal Quality Monitor LOS. When the internal signal quality monitor (Reg153) is less than the threshold in registers 154 and 155, this bit will be high. If a LOL (Reg137[4]) is high, this bit is forced to a 0. 3 Function dLOSlastTrigger Digital Loss of Signal Last Trigger. Holds a zero or one depending on which bit caused the last digital LOS event. 2 dLOS 1 Reserved 0 LOS Digital Loss of Signal. Digital LOS event status bit. Read returns zero. Loss of Signal. LOS status bit. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 83 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 145. TxdLosAssertThresh Bit D7 D6 D5 D4 D3 TxdLosAssertThresh[7:0] Type R/W D1 D0 N ot fo R r N ec o ew m m D e es nd ig e ns d Name D2 Reset settings = 0000 0000 Bit 7:0 Name Function TxdLosAssertThresh Transmitter Digital Loss of Signal Assert Threshold. The number of consecutive identical digits before digital LOS is asserted. Assert threshold in bits = (TxdLosAssertThresh x 5 + 2) x 1024. See Figure 10 on page 20. Register 146. TxdLosClearThresh Bit D7 D6 D5 D4 D3 Name TxdLosClearThresh[7:0] Type R/W D2 D1 D0 Reset settings = 0110 0000 Bit 7:0 84 Name Function TxdLosClearThresh[7:0] Transmitter Digital Loss of Signal Clear Threshold. Clear threshold that releases a digital LOS event. The number of consecutive 1024 bit fields with at least one transition that are required to clear dLos is calculated as RxdLos clearthresh x 16 + 1. See Figure 11 on page 21. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 152. TxphaseAdjust Bit D7 D6 D5 D4 Name D2 D1 D0 TxphaseAdjust[6:0] R R/W N ot fo R r N ec o ew m m D e es nd ig e ns d Type D3 Reset settings = 0000 0000 Bit Name 7 Reserved 6:0 Function Read returns zero. TxphaseAdjust[6:0] Transmitter Phase Adjust. Programmable range will cover at least –12 to 12 ps. The transfer function from Register # to actual ps of phase shift is highly variable. Value is signed, in 2s complement format: 100 0001 < –12 ps 011 1111 > 12 ps Register 153. TxSqmValue Bit D7 D6 D5 Name D4 D3 D2 D1 D0 TxSqmValue[5:0] Type R R/W Reset settings = 0000 0000 Bit Name 7:6 Reserved 5:0 Function Read returns zero. TxSqmValue[5:0] Transmitter Signal Quality Monitor Value. Measured value of the magnitude of the transmitter's received signal horizontal eye opening. 00 0000 = minimum 11 1111 = maximum Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 85 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 154. TxSqmConfig Bit D7 D6 D5 D4 TxSqmThresh[5:0] Type R/W D2 D1 D0 R/W R/W D1 D0 N ot fo R r N ec o ew m m D e es nd ig e ns d Name D3 Reset settings = 0000 0101 Bit 7:2 Name Function TxSqmThresh[5:0] Transmitter Signal Quality Monitor Threshold. Threshold used to assert SQM LOS alarm. 00 0000 = 0 (decimal) 11 1111 = 63 (decimal) Note: Default = 1 (decimal) 1 Reserved Do not change; must only write a 0 to this bit. 0 Reserved Do not change; must only write a 1 to this bit. Register 155. TxSqmDeassertThresh Bit D7 D6 D5 D4 D3 D2 Name TxSqmDeassertThresh[5:0] Type R/W Reset settings = 0000 1000 Bit Name 7:6 Reserved 5:0 Function Read returns zero. TxSqmDeassertThresh[5:0] Transmitter Signal Quality Monitor Deassert Threshold. Value where the SQM alarm is removed. 00 0000 = 0 (decimal) 11 1111 = 63 (decimal) Note: Default = 8 (decimal) 86 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 156. TxdPathConfig Bit D7 Name D5 dinvert clkOnLOS R/W R/W R D4 D3 D2 SquelchOnTxLOL SquelchOnTxLOS Squelch R/W R/W D1 D0 FIFOAutoReset FIFOReset R/W R/W R/W N ot fo R r N ec o ew m m D e es nd ig e ns d Type D6 Reset settings = 0000 0010 Bit Name 7 Reserved 6 dinvert 5 clkOnLOS Function Read returns zero. Data Invert. 0 = Normal operation. 1 = TXDOUT+ and TXDOUT– outputs (pins 30, 29) are inverted. Clock Output on Transmitter Loss of Signal. 0 = Normal operation. 1 = 622 MHz clock output on TXDOUT+ and TXDOUT– on transmitter LOS condition. 4 SquelchOnTxLOL Data Squelch on Transmit Loss of Lock. 0 = Normal operation. 1 = squelch TXDOUT output (pins 30, 29) on transmitter Loss of Lock condition. 3 SquelchOnTxLOS Data Squelch on Transmit Loss of Signal. 0 = Normal operation. 1 = squelch TXDOUT output (pins 30, 29) on transmitter Loss of Signal condition. 2 Squelch 1 FIFOAutoReset 0 FIFOReset Data Squelch. 0 = Normal operation. 1 = squelch TXDOUT output (pins 30, 29). FIFO Auto Reset. 0 = No reset of transmit FIFO on FIFO error. 1 = automatically reset transmit FIFO on FIFO underflow or overflow. FIFO pointer is reset to center value and FIFO is cleared. FIFO Reset. 0 = Normal operation. 1 = reset transmit FIFO. FIFO pointer is reset to center value and FIFO is cleared. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 87 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 157. TxtpSel D7 D6 D5 D4 D3 D2 D1 Name tpChkInvert tpChkSel[2:0] tpGenInvert tpGenSel[2:0] Type R/W R/W R/W R/W D0 N ot fo R r N ec o ew m m D e es nd ig e ns d Bit Reset settings = 0000 0000 Bit Name 7 tpChkInvert 6:4 tpChkSel[2:0] 3 tpGenInvert 2:0 tpGenSel[2:0] Function Test Pattern Checker Data Invert. 0 = normal operation. 1 = invert data applied to test pattern checker. Test Pattern Checker Mode Select. 000 = pattern checker disabled. 001 = check for PRBS7 pattern. 010 = check for PRBS31 pattern. 011 = check for 64 bit user defined pattern. Test Pattern Generator Data Invert. 0 = normal operation. 1 = invert generated pattern. Test Pattern Generator Mode Select. 000 = pattern generator disabled. 001 = generate PRBS7 pattern. 010 = generate PRBS31 pattern. 011 = generate 64 bit user defined pattern. Notes: 1. Users cannot switch from generating PRBS31 to PRBS7 directly. tpGenSel should be set to 000 (pattern generator disabled) before switching to PRBS7. Note that this only applies to switching from PRBS31 to PRBS7. 2. The PRBS31pattern is inverted as per Section 5.8 of O.150. 88 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 158. TxtpChkConfig Bit D7 D6 D5 D4 D3 Name D1 D0 tpSyncMask tpTimeBase[1:0] R/W R/W R N ot fo R r N ec o ew m m D e es nd ig e ns d Type D2 Reset settings = 0000 0010 Bit Name 7:3 Reserved 2 tpSyncMask 1:0 Function Read returns zero. Test Pattern Checker Sync Mask. 0 = Report loss of sync, followed by reset. 1 = After synchronization has been achieved a loss of sync will not be reported and the pattern checker will not be reset. tpTimeBase[1:0] Test Pattern Checker Timebase. The time or number of bits over which the pattern will be checked. 00 = continuous (infinite). 01 = (220 – 1024) bits 10 = (230 – 1024) bits 11 = (240 – 1024) bits Register 159. TxtpArbGenPtn Bit D7 D6 D5 D4 D3 Name TxtpArbGenPtn[7:0] Type R/W D2 D1 D0 Reset settings = 1010 1010 Bit 7:0 Name Function TxtpArbGenPtn[7:0] Transmitter Test Pattern Generator User Defined Pattern. Note: Bit 0 in Register 159 is the LSB of the 64-bit user-defined pattern, and Bit 7 in Register 166 is the MSB. The transmit sequence is from LSB to MSB. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 89 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 160. TxtpArbGenPtn Bit D15 D14 D13 D12 D11 TxtpArbGenPtn[15:8] Type R/W D9 D8 N ot fo R r N ec o ew m m D e es nd ig e ns d Name D10 Reset settings = 1010 1010 Bit 7:0 Name Function TxtpArbGenPtn[15:8] Transmitter Test Pattern Generator User Defined Pattern. Note: Bit 0 in Register 159 is the LSB of the 64-bit user-defined pattern, and Bit 7 in Register 166 is the MSB. The transmit sequence is from LSB to MSB. Register 161. TxtpArbGenPtn Bit D23 D22 D21 D20 D19 Name TxtpArbGenPtn[23:16] Type R/W D18 D17 D16 Reset settings = 1010 1010 Bit 7:0 Name Function TxtpArbGenPtn[23:16] Transmitter Test Pattern Generator User Defined Pattern. Note: Bit 0 in Register 159 is the LSB of the 64-bit user-defined pattern, and Bit 7 in Register 166 is the MSB. The transmit sequence is from LSB to MSB. Register 162. TxtpArbGenPtn Bit D31 D30 D29 D28 D27 Name TxtpArbGenPtn[31:24] Type R/W D26 D25 D24 Reset settings = 1010 1010 Bit 7:0 Name Function TxtpArbGenPtn[31:24] Transmitter Test Pattern Generator User Defined Pattern. Note: Bit 0 in Register 159 is the LSB of the 64-bit user-defined pattern, and Bit 7 in Register 166 is the MSB. The transmit sequence is from LSB to MSB. 90 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 163. TxtpArbGenPtn Bit D39 D38 D37 D36 D35 TxtpArbGenPtn[39:32] Type R/W D33 D32 N ot fo R r N ec o ew m m D e es nd ig e ns d Name D34 Reset settings = 1010 1010 Bit 7:0 Name Function TxtpArbGenPtn[39:32] Transmitter Test Pattern Generator User Defined Pattern. Note: Bit 0 in Register 159 is the LSB of the 64-bit user-defined pattern, and Bit 7 in Register 166 is the MSB. The transmit sequence is from LSB to MSB. Register 164. TxtpArbGenPtn Bit D47 D46 D45 D44 D43 Name TxtpArbGenPtn[47:40] Type R/W D42 D41 D40 Reset settings = 1010 1010 Bit 7:0 Name Function TxtpArbGenPtn[47:40] Transmitter Test Pattern Generator User Defined Pattern. Note: Bit 0 in Register 159 is the LSB of the 64-bit user-defined pattern, and Bit 7 in Register 166 is the MSB. The transmit sequence is from LSB to MSB. Register 165. TxtpArbGenPtn Bit D55 D54 D53 D52 D51 Name TxtpArbGenPtn[55:48] Type R/W D50 D49 D48 Reset settings = 1010 1010 Bit 7:0 Name Function TxtpArbGenPtn[55:48] Transmitter Test Pattern Generator User Defined Pattern. Note: Bit 0 in Register 159 is the LSB of the 64-bit user-defined pattern, and Bit 7 in Register 166 is the MSB. The transmit sequence is from LSB to MSB. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 91 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 166. TxtpArbGenPtn Bit D63 D62 D61 D60 D59 TxtpArbGenPtn[63:56] Type R/W D57 D56 N ot fo R r N ec o ew m m D e es nd ig e ns d Name D58 Reset settings = 1010 1010 Bit 7:0 Name Function TxtpArbGenPtn[63:56] Transmitter Test Pattern Generator User Defined Pattern. Note: Bit 0 in Register 159 is the LSB of the 64-bit user-defined pattern, and Bit 7 in Register 166 is the MSB. The transmit sequence is from LSB to MSB. Register 167. TxtpArbChkPtn Bit D7 D6 D5 D4 D3 Name TxtpArbChkPtn[7:0] Type R/W D2 D1 D0 Reset settings = 1010 1010 Bit 7:0 Name Function TxtpArbChkPtn[7:0] Transmitter Test Pattern Checker User Defined Pattern. Note: Bit 0 in Register 167 is the LSB of the received 64-bit user-defined pattern, and Bit 7 in Register 174 is the MSB. The receive sequence is from LSB to MSB. Register 168. TxtpArbChkPtn Bit D15 D14 D13 D12 D11 Name TxtpArbChkPtn[15:8] Type R/W D10 D9 D8 Reset settings = 1010 1010 Bit 7:0 Name Function TxtpArbChkPtn[15:8] Transmitter Test Pattern Checker User Defined Pattern. Note: Bit 0 in Register 167 is the LSB of the received 64-bit user-defined pattern, and Bit 7 in Register 174 is the MSB. The receive sequence is from LSB to MSB. 92 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 169. TxtpArbChkPtn Bit D23 D22 D21 D20 D19 TxtpArbChkPtn[23:16] Type R/W D17 D16 N ot fo R r N ec o ew m m D e es nd ig e ns d Name D18 Reset settings = 1010 1010 Bit 7:0 Name Function TxtpArbChkPtn[23:16] Transmitter Test Pattern Checker User Defined Pattern. Note: Bit 0 in Register 167 is the LSB of the received 64-bit user-defined pattern, and Bit 7 in Register 174 is the MSB. The receive sequence is from LSB to MSB. Register 170. TxtpArbChkPtn Bit D31 D30 D29 D28 D27 Name TxtpArbChkPtn[31:24] Type R/W D26 D25 D24 Reset settings = 1010 1010 Bit 7:0 Name Function TxtpArbChkPtn[31:24] Transmitter Test Pattern Checker User Defined Pattern. Note: Bit 0 in Register 167 is the LSB of the received 64-bit user-defined pattern, and Bit 7 in Register 174 is the MSB. The receive sequence is from LSB to MSB. Register 171. TxtpArbChkPtn Bit D39 D38 D37 D36 D35 Name TxtpArbChkPtn[39:32] Type R/W D34 D33 D32 Reset settings = 1010 1010 Bit 7:0 Name Function TxtpArbChkPtn[39:32] Transmitter Test Pattern Checker User Defined Pattern. Note: Bit 0 in Register 167 is the LSB of the received 64-bit user-defined pattern, and Bit 7 in Register 174 is the MSB. The receive sequence is from LSB to MSB. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 93 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 172. TxtpArbChkPtn Bit D47 D46 D45 D44 D43 TxtpArbChkPtn[47:40] Type R/W D41 D40 N ot fo R r N ec o ew m m D e es nd ig e ns d Name D42 Reset settings = 1010 1010 Bit 7:0 Name Function TxtpArbChkPtn[47:40] Transmitter Test Pattern Checker User Defined Pattern. Note: Bit 0 in Register 167 is the LSB of the received 64-bit user-defined pattern, and Bit 7 in Register 174 is the MSB. The receive sequence is from LSB to MSB. Register 173. TxtpArbChkPtn Bit D55 D54 D53 D52 D51 Name TxtpArbChkPtn[55:48] Type R/W D50 D49 D48 Reset settings = 1010 1010 Bit 7:0 Name Function TxtpArbChkPtn[55:48] Transmitter Test Pattern Checker User Defined Pattern. Note: Bit 0 in Register 167 is the LSB of the received 64-bit user-defined pattern, and Bit 7 in Register 174 is the MSB. The receive sequence is from LSB to MSB. Register 174. TxtpArbChkPtn Bit D63 D62 D61 D60 D59 Name TxtpArbChkPtn[63:56] Type R/W D58 D57 D56 Reset settings = 1010 1010 Bit 7:0 Name Function TxtpArbChkPtn[63:56] Transmitter Test Pattern Checker User Defined Pattern. Note: Bit 0 in Register 167 is the LSB of the received 64-bit user-defined pattern, and Bit 7 in Register 174 is the MSB. The receive sequence is from LSB to MSB. 94 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 175. TxtpTargetErr Bit D7 D6 D5 D4 D3 TxtpTargetErr[7:0] Type R/W D1 D0 N ot fo R r N ec o ew m m D e es nd ig e ns d Name D2 Reset settings = 1111 1111 Bit Name 7:0 TxtpTargetErr[7:0] Function Transmitter Test Pattern Checker Target Error Count. If the value in the TxtpChkErrCnt register (register 181) exceeds this target error count, an interrupt will be generated. The value is represented as an 8-bit floating point number. Mantissa = bits[7:4] Exponent = bits[3:0] Base = 16 0000 0000 = 0 (decimal) 0101 0111 = (5/16) x 167 (decimal) 1111 1111 = (15/16) x 1615(decimal) This register value does not represent a target bit error rate (BER). Rather, it is a target bit error count for the period defined by tpTimeBase[1:0]. Register 176. TxtpChkErrCnt (LSB of a 40-bit Register) Bit D7 D6 D5 D4 D3 Name TxtpChkErrCnt[7:0] Type R D2 D1 D0 Reset settings = undefined Bit 7:0 Name Function TxtpChkErrCnt[7:0] Transmitter Test Pattern Checker Error Count. When using a defined timebase, this register holds the error count from the last completed timebase. In the continuous timebase setting, the register holds the current running error count. Reading the least significant byte LSB latches the upper bytes. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 95 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 177. TxtpChkErrCnt (40-bit Register) Bit D15 D14 D13 D12 D11 TxtpChkErrCnt[15:8] Type R D9 D8 N ot fo R r N ec o ew m m D e es nd ig e ns d Name D10 Reset settings = undefined Bit 7:0 Name Function TxtpChkErrCnt[15:8] Transmitter Test Pattern Checker Error Count. When using a defined timebase, this register holds the error count from the last completed timebase. In the continuous timebase setting, the register holds the current running error count. Reading the least significant byte latches the upper bytes. Register 178. TxtpChkErrCnt (40-bit Register) Bit D23 D22 D21 D20 D19 Name TxtpChkErrCnt[23:16] Type R D18 D17 D16 Reset settings = undefined Bit 7:0 Name Function TxtpChkErrCnt[23:16] Transmitter Test Pattern Checker Error Count. When using a defined timebase, this register holds the error count from the last completed timebase. In the continuous timebase setting, the register holds the current running error count. Reading the least significant byte latches the upper bytes. Register 179. TxtpChkErrCnt (40-bit Register) Bit D31 D30 D29 D28 D27 Name TxtpChkErrCnt[31:24] Type R D26 D25 D24 Reset settings = undefined Bit 7:0 96 Name Function TxtpChkErrCnt[31:24] Transmitter Test Pattern Checker Error Count. When using a defined timebase, this register holds the error count from the last completed timebase. In the continuous timebase setting, the register holds the current running error count. Reading the least significant byte latches the upper bytes. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 180. TxtpChkErrCnt (MSB of a 40-bit Register) Bit D39 D38 D37 D36 D35 TxtpChkErrCnt[39:32] Type R D33 D32 N ot fo R r N ec o ew m m D e es nd ig e ns d Name D34 Reset settings = undefined Bit 7:0 Name Function TxtpChkErrCnt[39:32] Transmitter Test Pattern Checker Error Count. When using a defined timebase, this register holds the error count from the last completed timebase. In the continuous timebase setting, the register holds the current running error count. Reading the least significant byte latches the upper bytes. Note: Combined registers 176 to 180, 0000000000 = 0 (decimal) FFFFFFFFFF = 240 – 1 (decimal) Register 181. TxtpChkErr Bit D7 D6 D5 D4 D3 Name TxtpChkErr[7:0] Type R D2 D1 D0 Reset settings = undefined Bit 7:0 Name Function TxtpChkErr[7:0] Transmitter Test Pattern Checker Error. Measured error count in 8-bit floating point notation. The content of this register is an alternative format to the TxtpChkErrCnt. Mantissa = bits [7:4] Exponent = bits [3:0] Error count = (Mantissa/16) x 16Exponent 0000 0000 = 0 (decimal) 0101 0111 = (5/16) x 167 (decimal) 1111 1111 = (15/16) x 1615(decimal) Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 97 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 184. OutputLevel Bit D7 D6 D5 D4 D3 D2 D1 HsPowerCtl[1:0] Reserved outLevel[2:0] Type R/W R/W R/W N ot fo R r N ec o ew m m D e es nd ig e ns d Name D0 Reset settings = 1111 0101 Bit Name 7:6 Reserved Do not change; must only write 11 to these bits. 5:3 Reserved These bits are not user defined, and writes to these bits are ignored. 2:0 outLevel[2:0] 98 Function Output Level. TXDOUT output drive level. 000 = 100 mVppd. 001 = 200 mVppd. 010 = 300 mVppd. 011 = 400 mVppd. 100 = 500 mVppd. 101 = 600 mVppd. 110 = 700 mVppd. 111 = 800 mVppd. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Register 205. TxPDGainAcq Bit D7 D6 D5 D4 D3 D2 TxPDGainAcq[2:0] Reserved Type R/W R/W D0 N ot fo R r N ec o ew m m D e es nd ig e ns d Name D1 Reset settings = 1000 1101 Bit Name Function 7:5 TxPDGainAcq[2:0] TX phase detector gain during acquisition. Note that these bits require a one time write of 000b after a power-up or a software reset. 4:0 Reserved Reserved; must only write 01101b to these bits. Register 226. TxLoopFAcq Bit D7 D6 D5 D4 D3 Name TxLoopFAcqCtl TxLoopFAcq[6:0] Type R/W R/W D2 D1 D0 Reset settings = 0001 1110 Bit Name 7 TxLoopFAcqCtl 6:0 TxLoopFAcq[6:0] Function TX Acquistion Loop Filter Override. 1 = Use value written in Bit [6:0]. Set to 1 only when TX LOL is asserted. 0 = Use internally generated value. Set to 0 when TX LOL is deasserted. TX Loop Filter Setting for Acquisition. TX Loop filter override setting to be used during acquisiton. Set to 001 1000b when TX LOL is asserted and to 000 0000 when TX LOL is deasserted. Note that any read back may not return the last written value. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 99 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 SS 29 SD 30 GND TXDO UT– 31 V DD GND 32 TXDO UT+ V DD 14. Pin Descriptions: Si5040 28 27 26 25 GND 1 24 RX_LOL 2 23 GND RX_LOS 3 22 TD+ VDDIO 4 21 TD– GND 5 20 GND RXDIN– 6 19 RD+ RXDIN+ 7 18 RD– GND 8 17 GND GND PAD N ot fo R r N ec o ew m m D e es nd ig e ns d GND PAD SCK GND PAD 12 13 14 15 16 REFCLK+ REFCLK- VDD INTERRUPT NC 11 NC 10 V DD 9 SPSEL GND PAD Figure 24. Si5040 Pin Configuration (Transparent Top View) Table 13. Si5040 Pin Descriptions Pin Name Type* Level Description 16 INTERRUPT DO LVTTL or Open Drain Interrupt (Active Low). The interrupt output pin is provided to indicate potential fault conditions or changes in status. Interrupt sources are maskable by setting the Interrupt Mask register, and interrupt status is available from the Interrupt Status register. The interrupt function can be disabled in the Interrupt Enable bit. The interrupt pin can be configured via the Interrupt Output register as either an open drain output (default) or LVTTL output. 19,18 RD+ RD– AO 13,14 REFCLK+ REFCLK– AI 7, 6 RXDIN+ RXDIN– AI Differential CML Receiver Data Output. High-speed XFI-compliant receiver data output recovered from the RXDIN input. PECL Reference Clock Input. A reference clock at this input is applied to the transmit CMU and to the receiver and transmitter CDRs. The use of a reference clock is optional. If the jitter performance of the external reference clock is acceptable, the Si5040 can be operated in CMU mode. In this mode, the CMU derives the line-rate clock by multiplying the clock frequency applied to the REFCLK inputs. If the REFCLK input is synchronous, the CMU multiplies the frequency by 64. The resulting line-rate is frequency-locked to the serial data. A FIFO in the data path accommodates any jitter differences between the serial data and the CMU line-rate clock. Differential CML Receiver Data Input. Data signal RD is recovered from the high-speed differential signal present on these pins. Data over the 9.8304 Gbps to 11.3 Gbps range is recovered. *Note: TYPE: P = Power; AI = Analog Input; AO = Analog Output; DI = Digital Input; DO = Digital Output; DIO = Digital Input/Output. 100 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Table 13. Si5040 Pin Descriptions (Continued) Name Type* Level Description 2 RX_LOL DO LVTTL Receiver Loss of Lock (Active High). This output is asserted when the receiver path is in the lossof-lock state. If enabled in the receiver Interrupt Mask register, this event may cause an interrupt. This pin is reflected as bit 4 in Register 9. The latched version of this pin is in Register 5, bit 4. In the absence of an external reference, the lock detect circuitry uses a data quality measure to determine when frequency lock has been lost with the incoming data stream. This pin may also be programmed as a 622 MHz clock output that is synchronous to the data applied at the transmitter data (TD) input. N ot fo R r N ec o ew m m D e es nd ig e ns d Pin 3 RX_LOS DO LVTTL Receiver Loss of Signal (Active High). The RX_LOS output is asserted when a loss-of-signal condition occurs for Analog LOS, Digital Count LOS, or Signal Quality Monitor LOS. 22,21 TD+ TD– AI Differential CML Transmitter Data Input. High-speed XFI-compliant transmitter data input. 30,29 TXDOUT+ TXDOUT– AO Differential CML Transmitter Data Output. Data present at the TD input is retimed and output on the TXDOUT pins. Transmit range of operation is 9.8304 Gbps to 11.3 Gbps. Serial Port 24 SCK DI LVTTL Serial Clock. Clock input for SPI-like and I2C interface. 25 SD DIO LVTTL or Open Drain 9 SPSEL DI LVTTL Serial Data. Serial bidirectional data interface pin for the SPI-like or I2C serial interface. This pin may be programmed as LVTTL or open drain (by default) in Register 2. When in LVTTL mode, the pin is initially in a high-impedance state. SPI-like or I2C Bus Select. In a logic low state, this input selects I2C mode of operation. In a logic high state, SPI-like mode of operation is selected. This input has a weak internal pullup. 26 SS DI LVTTL Chip Select. Chip select pin for SPI-like interface, active low. This input has a weak internal pullup. Note that this pin defines the I2C when the serial interface is in I2C mode. See "10.1. I2C Interface" on page 35 for details. *Note: TYPE: P = Power; AI = Analog Input; AO = Analog Output; DI = Digital Input; DO = Digital Output; DIO = Digital Input/Output. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 101 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Table 13. Si5040 Pin Descriptions (Continued) Pin Name Type* Level Description Power and Ground GND P GND Supply Ground. Connect to system GND. Ensure a very low impedance path for optimal performance. Paddle GND P GND Paddle Ground. Must connect to system GND. Ensure a very low impedance path for optimal performance. 12, 15, 27,32 VDD P 1.8 VDC Supply Voltage. Nominally 1.8 V. Upon power up,if VDD and VDDIO are not tied to the same supply voltage, the VDD voltage must achieve 1.5 V before VDDIO is applied and reaches .25 V. Failure to do so may cause the SD line to glitch low. 4 VDDIO P 3.3 VDC or 1.8 VDC LVTTL I/O Supply Voltage. Connect to either 1.8 or 3.3 V. When connected to 3.3 V, LVTTL compatible voltage swings are supported on the LVTTL inputs and LVTTL outputs of the device. N ot fo R r N ec o ew m m D e es nd ig e ns d 1, 5, 8, 17, 20, 23, 28, 31 NC Pins 11 10 NC. Do not connect to these pins. *Note: TYPE: P = Power; AI = Analog Input; AO = Analog Output; DI = Digital Input; DO = Digital Output; DIO = Digital Input/Output. 102 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 15. Ordering Guide Part Number* Package Lead-Free Temperature Si5040-D-GM 32-lead LGA Yes –40 to 95 °C N ot fo R r N ec o ew m m D e es nd ig e ns d *Note: Add an “R” at the end of the device number to denote the tape and reel option; 2500 quantity per reel. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 103 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 16. Package Outline: Si5040 N ot fo R r N ec o ew m m D e es nd ig e ns d Figure 25 illustrates the package details for the Si5040. Table 14 lists the values for the dimensions shown in the illustration. Figure 25. 32-Pin Land Grid Array Package (LGA) Table 14. Package Diagram Dimensions Dimension Min Nom Max A 0.75 0.85 0.95 b 0.27 0.30 0.33 c 1.00 1.10 1.20 D 5.00 BSC. e 0.50 BSC. E 5.00 BSC. f 0.735 BSC. g 0.735 BSC. h 2.185 BSC. j 2.185 BSC. aaa 0.10 bbb 0.10 ccc 0.10 ddd 0.10 eee 0.10 Notes: 1. All dimensions shown are in millimeters (mm) unless otherwise noted. 2. Dimensioning and Tolerancing per ANSI Y14.5M-1994. 3. Recommended card reflow profile is per the JEDEC/IPC J-STD-020 specification for Small Body Components. 104 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 17. Recommended VDD Power Supply Filtering Because of the internal bypass capacitance and voltage regulators, the external supply bypass requirements for the Si5040 are minimal. N ot fo R r N ec o ew m m D e es nd ig e ns d 1.8 V 12 .1 µF VDD Si5040 VDD 32 .01 µF .01 µF VDD 15 Note: 1. Place a .01 µF cap very close to each VDD pin (12, 15, 27, 32) and place a single 0.1 µF cap close to the Si5040. 2. No power sequencing is required. .01 µF VDD 27 .01 µF Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 105 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 DOCUMENT CHANGE LIST Revision 0.5 to Revision 0.8 68, bit3:0) in Table 3  Removed both Stressed Eye Jitter Tolerance and Sinusoidal Jitter Tolerance from Table 3.  Revision 0.8 to Revision 0.85    Corrected "OCIP2" typo in TXDOUT jitter test conditions in Table 5. Clarified jitter transfer peaking test condition in Table 5. Removed Note 2 from Table 5. Changed definition of bits 7:6 in Register 56 to Reserved. Changed definition of bits 7:6 in Register 184 to Reserved. Updated mechanical ground pad dimension in Table 14. Updated package drawing in Figure 25. Updated Table 14, “Package Diagram Dimensions,” on page 104. N ot fo R r N ec o ew m m D e es nd ig e ns d  Updated final specification numbers for TBD items. Updated register name in Register 16. Changed aLosThresh[1:0] to aLosThresh[9:8] in Register 13. Jitter Tolerance measurement frequency changed from 400 MHz to 80 MHz. Corrected typos in the jitter transfer bandwidth specification in Tables 4 and 5. Corrected typos in Table 7, “CMU Timing Modes,” on page 12. Updated crystal recommendation list. Removed I2C fall time spec in Table 8. Updated Constant Duty Cycle Control range to show adjustment range of 26% to 74% in Registers 21 and 22. Updated definition of Proportional Slice Threshold to show Threshold = 50% + sliceLvl/65536 x 100 in Registers 21and 22/ Changed definition of Register 139, bit 4, from R/W to R. Clarified operation of fifoErr bit in the Register 4, bit 3. Updated definition of Reserved bits in Registers 56 and 184, bits 5:3. Reduced the input reference clock frequencies in Table 5 from 712.5 and 178.125 MHz to 709.38 and 177.34 MHz, respectively. Modified Detailed Block Diagram to show Slice_ADJ controlling the Programmable Equalizer block. Clarified definition of lolMode in Register 7 and 135, bit 2. Clarified description of Register 2, bit 4, as “SD pin drive configuration”. Changed Reserved bit (Register 2, bit 7) to support configuration of RX_LOS pin as open drain output. The default configuration register bit settings changed to the following: Reg6[7:4] = 4h, Reg134[7:4] = 4h, Reg138[3:1] = 111b, Reg145[7:0] = 00h Reg154[7:2] = 1, Reg155[5:0] = 8, Reg184[7:6] = 11b, Reg56[7:6] = 11b, Reg85[7:5] = 111b. Revision ID, Register 1 bits 7:4, changed from 2 to 3 decimal to reflect Rev D. Updated Theta JA value in Table 11. Deleted Note 4 from Table 7. Updated "Acquisition Time" test condition (Register                           Revision 0.85 to Revision 0.86               Updated title on page 1. Updated block diagram. Changed pins 10 and 11 to NC. Updated Typical Application Schematic (Section 3). Clarified operation of each slice mode in section "5.5 Receiver Slice Control". Updated Section "5.8. Receiver Loss of Lock (LOL)." Added technical info on RX SQM and Frequency LOL; added info on dynamic register control and acquisition time enhancement. Added Section "5.11. Recommended Pre-Emphasis on the RD Signal." Updated Section 6.4. Transmitter Loss of Lock (LOL). Added technical info on TX SQM and Frequency LOL; added info on dynamic register control and acquisition time enhancement. Removed section "6.7.4. Low Bandwidth Jitter Attenuation Mode (Mode 3)" and support for mode 3. Updated section "7. Loopback Modes" with technical info on XFI and Lineside loopback modes. Updated Section "12. Programmable Power Down Options." Added register summary and definitions in Section 13 for Registers 77, 98, 106-107, 205, and 226. Removed Section “18. Recommended Crystal Resonators” on page 94. Max power/current now specified for Mode 0 instead of Mode 3. 106 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 Si5040 Revision 0.86 to Revision 1.2   N ot fo R r N ec o ew m m D e es nd ig e ns d  Removed sections 5.8.3 and 6.4.3 since fast acquisition is no longer supported. Clarified operation of Register 7[3:2] in register descriptions and "5.8.1. SQM LOL" on page 24. Updated part number in "15. Ordering Guide" on page 103. Added information on voltage application to VDD and VDDIO in pin descriptions. Removed reference to Mode 7 from Register 134 since Mode 7 does not exist. Changed all SCL references to SCK and all SDA reference to SD for consistency.    Revision 1.2 to Revision 1.3      Clarified RX LOL feature in sections “5.8.1.1. Dynamic Register Control” and “5.8.2. Frequency LOL” Added section “5.8.3. Acquisition Time Enhancement” Clarified TX LOL feature in sections “6.4.1.1. Dynamic Register Control” and “6.4.2. Frequency LOL” Added section “6.4.3. Acquisition Time Enhancement” Changed TX and RX path data rate minimum parameters from 9.9 to 9.8 Gbps to allow for 9.8304 Gbps CPRI data rate Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 107 Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 28, 2021 ClockBuilder Pro Customize Skyworks clock generators, jitter attenuators and network synchronizers with a single tool. With CBPro you can control evaluation boards, access documentation, request a custom part number, export for in-system programming and more! www.skyworksinc.com/CBPro Portfolio SW/HW Quality Support & Resources www.skyworksinc.com/ia/timing www.skyworksinc.com/CBPro www.skyworksinc.com/quality www.skyworksinc.com/support Copyright © 2021 Skyworks Solutions, Inc. All Rights Reserved. Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes. No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks’ Terms and Conditions of Sale. THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury, death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any damages resulting from such improper use or sale. Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of Skyworks’ published specifications or parameters. Skyworks, the Skyworks symbol, Sky5®, SkyOne®, SkyBlue™, Skyworks Green™, Clockbuilder®, DSPLL®, ISOmodem®, ProSLIC®, and SiPHY® are trademarks or registered trademarks of Skyworks Solutions, Inc. or its subsidiaries in the United States and other countries. Third-party brands and names are for identification purposes only and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are incorporated by reference. Skyworks Solutions, Inc. | Nasdaq: SWKS | sales@skyworksinc.com | www.skyworksinc.com USA: 781-376-3000 | Asia: 886-2-2735 0399 | Europe: 33 (0)1 43548540 |
SI5040-D-GM 价格&库存

很抱歉,暂时无法提供与“SI5040-D-GM”相匹配的价格&库存,您可以联系我们找货

免费人工找货