0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
AAT2601BIIH-T1

AAT2601BIIH-T1

  • 厂商:

    SKYWORKS(思佳讯)

  • 封装:

    WFQFN36_EP

  • 描述:

    ICPMICTOTALPOWER36TQFN

  • 数据手册
  • 价格&库存
AAT2601BIIH-T1 数据手册
DATA SHEET AAT2601B Total Power Solution for Portable Applications General Description Features The AAT2601B is a member of Skyworks' Total Power Management IC (TPMICTM) product family. It contains a single-cell Lithium Ion/Polymer battery charger, a fully integrated step-down converter and 5 low dropout (LDO) regulators. The device also includes 2 load switches for dynamic power path/sleep mode operation, making it ideal for small handheld portable navigation devices. • Voltage Regulator VIN Range: 4.5V to 6V • Complete Power Integration ▪ Integrated Load Switches to Power Converters from AC Adapter or Battery Automatically • Low Standby Current ▪ 170μA (typ) w/ Buck, LDO1, and LDO2 Active, No Load • One Step-Down Buck Converter ▪ 1.8V, 300mA Output ▪ 1.5MHz Switching Frequency ▪ Fast Turn-On Time (100μs typ) • Five LDOs Programmable with I2C ▪ LDO1: 3.3V, 300mA Programmable with I2C ▪ LDO2: 1.2V, 150mA ▪ LDO3: 1.2V, 150mA ▪ LDO4: 3.3V, 150mA Programmable with I2C ▪ LDO5: 3.3V, 150mA Programmable with I2C ▪ PSRR: 60dB@10kHz ▪ Noise: 50μVrms for LDO3, LDO4, and LDO5 • One Battery Charger ▪ Digitized Thermal Regulation ▪ Charge Current Programming up to 1.4A ▪ Charge Current Termination Programming ▪ Automatic Trickle Charge for Battery Preconditioning (2.8V Cutoff) • Adapter OK (ADPP) and Reset (RESET) Timer Outputs • Separate Enable Pins for Supply Outputs • Over-Current Protection • Over-Temperature Protection • 5x5mm TQFN55-36 Package The battery charger is a complete thermally regulated constant current/constant voltage linear charger. It includes an integrated pass device, reverse blocking protection, high accuracy current and voltage regulation, charge status, and charge termination. The charging current, charge termination current, and recharge voltage are programmable with an external resistor and/or by a standard I2C interface. The step-down DC/DC converter is integrated with internal compensation and operates at a switching frequency of 1.5MHz, thus minimizing the size of external components while keeping switching losses low and efficiency greater than 92%. The five LDOs offer 60dB power supply rejection ratio (PSRR) and low noise operation making them suitable for powering noise-sensitive loads. All six voltage regulators operate with low quiescent current. The total no load current when the step-down converter and 2 LDOs are enabled is only 170μA. The AAT2601B is available in a thermally enhanced low profile 5x5x0.75mm 36-pin TQFN package. Applications • • • • • Digital Cameras GPS and PND Handheld Instruments PDAs and Handheld Computers Portable Media Players Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 202181B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • March 19, 2013 1 DATA SHEET AAT2601B Total Power Solution for Portable Applications Typical Application To AVIN1, AVIN2, PVIN SYSOUT System Supply SYSOUT LDO 500mΩ 100mΩ BAT CHGIN 5V from AC Adapter or USB Port + 10μF To SYSOUT - 10μF 1 cell Li+ battery 100k ADPP Charger Control STAT ISET TS CT ENBAT Ref USE_USB To SYSOUT 100k To SYSOUT 100k 10kW NTC For BAT Temp sense 1.24k 0.1μF SDA SCL To SYSOUT PVIN EN_TEST μC UVLO EN_HOLD I 2C and Enable Control EN_KEY LX VIN 3.3μH 1.8V 300mA Step-down BUCK Ref ON_KEY 10μF 4.7μF OUTBUCK PGND Enable RESET To OUT1 100k EN2 EN3 EN4 VIN REF CNOISE EN5 AVIN2 AVIN1 VIN Ref To SYSOUT LDO1 LDO2 LDO3 Enable VIN Ref Enable VIN Ref LDO4 LDO5 Enable VIN Ref Enable Ref VIN Enable To SYSOUT AGND OUT5 3.3V 150mA OUT4 3.3V 150mA 4.7μF 2 OUT3 1.2V 150mA 4.7μF OUT2 1.2V 150mA 10μF OUT1 3.3V 300mA 10μF 22μF Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 202181B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • March 19, 2013 0.01μF DATA SHEET AAT2601B Total Power Solution for Portable Applications Pin Descriptions Pin # Symbol 1 EN_TEST 2 EN_HOLD 3 EN_KEY 4 5 6 7 8 9 10 11 12 13 14 15 16 17 ON_KEY EN2 EN3 EN4 EN5 OUT5 OUT4 AVIN2 OUT3 OUT2 AVIN1 OUT1 AGND CNOISE 18 RESET 19 ADPP 20 21 22 23 LX PGND PVIN OUTBUCK 24, 25 SYSOUT 26, 27 28 BAT CHGIN 29 USE_USB 30 ENBAT 31 TS 32 ISET 33 CT 34 STAT 35 36 SDA SCL EP EP Function Similar to EN_HOLD but intended for use with the automatic tester or as a hands free enable input pin indicating hands free phone operation with a headset. It is also internally pulled to GND when floating. Enable for the system. EN_HOLD must be held high by the processor to maintain core power. It is internally pulled to GND when floating. Enable for the system. An internal pull-up resistor keeps the pin pulled up to an internal supply to keep the system off when there is no CHGIN input. Connect a normally-open pushbutton switch from this pin to GND. There is an internal 300ms debounce delay circuit to filter noise. Buffered logic output of the EN_KEY pin with a logic signal from ground to OUT1. Enable for LDO2 (Internally pulled low when floating). Enable for LDO3 (Internally pulled low when floating). Enable for LDO4 (Internally pulled low when floating). Enable for LDO5 (Internally pulled low when floating). Output for LDO5 (when shut down, pulled down with 10k) Output for LDO4 (when shut down, pulled down with 10k) Analog voltage input. Must be tied to SYSOUT on the PCB. Output for LDO3. Output for LDO2. Analog voltage input. Must be tied to SYSOUT on the PCB. Output for LDO1. Signal ground. Noise Bypass pin for the internal reference voltage. Connect a 0.01μF capacitor to AGND. RESET is the open drain output of a 50ms reset timer. RESET is released after the 50ms timer times out. RESET is active low and is held low during shutdown. RESET should be tied to a 10K or larger pullup to OUTBUCK. Open Drain output. Will pull low when VCHGIN > 4.5V. When this happens, depending on the status of the USE_USB pin, the charge current will be reset to the default values (see Battery Charger and I2C Serial Interface and Programmability section) Step-down Buck converter switching node. Connect an inductor between this pin and the output. Power Ground for step-down Buck converter. Input power for step-down Buck converter. Must be tied to SYSOUT. Feedback input for the step-down Buck converter. System Power output. Connect to the input voltage pins PIN, AVIN1/2 for the step-down converter and LDOs and other external supply requirements. Connect to a Lithium Ion battery. Power input from either external adapter or USB port. When pulled high, fast charge current is set to 100mA regardless of the resistor value present on the ISET pin. Additionally, the CHGIN-SYSOUT LDO will be disabled and the BAT-SYSOUT load switch will be enabled. Active low enable for the battery charger (Internally pulled low when floating) Battery Temperature Sense pin with 75μA output current. Connect the battery’s NTC resistor to this pin and ground. Charge current programming input pin (Tie a 1.24k to GND for 800mA fast charge current). Can be used to monitor charge current. Charger Safety Timer Pin. A 0.1μF ceramic capacitor should be connected between this pin and GND. Connect directly to GND to disable the timer function. Battery charging status pin output. Connected internally between GND and OUT1. Used to monitor battery charge status. I2C serial data pin, open drain; requires a pullup resistor. I2C serial clock pin, open drain; requires a pullup resistor. The exposed thermal pad (EP) must be connected to board ground plane and pins 16 and 21. The ground plane should include a large exposed copper pad under the package for thermal dissipation (see package outline). Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 202181B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • March 19, 2013 3 DATA SHEET AAT2601B Total Power Solution for Portable Applications Pin Configuration SCL SDA STAT CT ISET TS ENBAT USE_USB CHGIN TQFN55-36 (Top View) 36 EN_TEST EN_HOLD EN_KEY ON_KEY EN2 EN3 EN4 EN5 OUT5 35 34 33 32 31 30 29 28 1 27 2 26 3 25 4 24 5 23 6 22 7 21 8 20 9 19 11 12 13 14 15 16 17 18 OUT4 AVIN2 OUT3 OUT2 AVIN1 OUT1 AGND CNOISE RESET 10 BAT BAT SYSOUT SYSOUT OUTBUCK PVIN PGND LX ADPP 4 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 202181B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • March 19, 2013 DATA SHEET AAT2601B Total Power Solution for Portable Applications Absolute Maximum Ratings1 TA = 25°C unless otherwise noted. Symbol VIN Power and logic pins TA TS TLEAD Description Input Voltage, CHGIN, BAT Maximum Rating Operating Junction Temperature Range Storage Temperature Range Maximum Soldering Temperature (at leads, 10 sec) Value Units -0.3 to 6.5 VIN + 0.3 -40 to 85 -65 to 150 300 V V °C °C C Value Units 25 4 C/W W Recommended Operating Conditions2 Symbol θJA PD Description Thermal Resistance Maximum Power Dissipation 1. Stresses above those listed in Absolute Maximum Ratings may cause permanent damage to the device. Functional operation at conditions other than the operating conditions specified is not implied. Only one Absolute Maximum Rating should be applied at any one time. 2. Thermal Resistance was measured with the AAT2601B device on the 4-layer FR4 evaluation board in a thermal oven. The amount of power dissipation which will cause the thermal shutdown to activate will depend on the ambient temperature and the PC board layout ability to dissipate the heat. See Figures 11-14. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 202181B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • March 19, 2013 5 DATA SHEET AAT2601B Total Power Solution for Portable Applications Electrical Characteristics1 VIN = 5V, VBAT = 3.6V, -40C ≤ TA ≤ +85C, unless noted otherwise. Typical values are TA = 25C. Symbol Description Power Supply VIN CHGIN Input Voltage IQ Battery Standby Current ISHDN Battery Shutdown Current Under-Voltage Lockout for CHGIN UVLO Battery Under-Voltage Lockout Leakage Current from BAT Pin IBAT Startup Timers RESET Reset Timer Charger Voltage Regulation VBAT_REG Output Charge Voltage Regulation VMIN Preconditioning Voltage Threshold VRCH Battery Recharge Voltage Threshold Conditions Min Typ 4.5 Buck, LDO1 + LDO2, no load EN_TEST, EN_HOLD, EN2, EN3, EN4, EN5 = GND, EN_KEY floating CHGIN rising CHGIN falling BAT rising BAT falling VBAT = 4V, VCHGIN = 0V Initiated when OUT1 = 90% of final value 0C ≤ TA ≤ +70C (No trickle charge option available) I2C Recharge Code = 00 (default) I2C Recharge Code = 01 I2C Recharge Code = 10 I2C Recharge Code = 11 Max Units 6 V μA 10.0 μA 4.5 V 5 V V V μA 170 4.25 4.15 2.6 2.35 2 35 ms 4.158 2.6 4.200 2.8 4.00 4.05 4.10 4.15 4.242 3.0 720 800 880 V V V V V V Charger Current Regulation ICH_CC KI_SET ICH_PRE Constant-Current Mode Charge Current Charge Current Set Factor: ICH_CC/IISET Preconditioning Charge Current RISET = 1.24k (for 0.8A), USE_USB = Low, I2C ISET code = 000, VBAT = 3.6V, VCHGIN = 5.0V USE_USB = High, I2C ISET Code = 000, VBAT = 3.6V Constant Current Mode, VBAT = 3.6V Charge Termination Threshold Current Charging Devices RDS(ON) Charging Transistor ON Resistance Logic Control / Protection VEN_HOLD, Input High Threshold VEN_KEY, Input Low Threshold VEN_TEST VADPP IADPP VSTAT ISTAT VOVP Output Low Voltage Output Pin Current Sink Capability Output High Voltage Output Pin Current Source Capability Over-Voltage Protection Threshold 85 100 115 800 mA/mA RISET = 1.24k, USE_USB = Low 12 % ICH_CC IC I2C I2C I2C I2C 50 5 10 15 20 mA 2 ICH_TERM mA ISET Code = 000, USE_USB = High Term Code = 00 (default) Term Code = 01 Term Code = 10 Term Code = 11 VIN = 5V 0.6 % ICH_CC 0.9 1.4 V Pin Sinks 4mA 0.4 V 0.4 8 VOUT1 1.5 V mA V mA V 4.3 1. Specification over the –40°C to +85°C operating temperature range is assured by design, characterization and correlation with statistical process controls. 6  Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 202181B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • March 19, 2013 DATA SHEET AAT2601B Total Power Solution for Portable Applications Electrical Characteristics1 VIN = 5V, VBAT = 3.6V, -40C ≤ TA ≤ +85C, unless noted otherwise. Typical values are TA = 25C. Symbol Description Logic Control / Protection (continued) VOCP Over Current Protection Threshold TC Constant Current Mode Time Out TK Trickle Charge Time Out TV Constant Voltage Mode Time Out ITS Current Source from TS Pin TS1 TS Hot Temperature Fault TS2 TS Cold Temperature Fault TLOOP_IN TLOOP_OUT TREG Load Switches / RDS(ON),BAT-SYSOUT RDS(ON),CHGIN-SYSOUT Thermal Loop Entering Threshold Thermal Loop Exiting Threshold Thermal Loop Regulation SYSOUT LDO On-Resistance of BAT-SYSOUT Load Switch On-Resistance of CHGIN-SYSOUT Load Switch Sysout LDO Input Voltage Range Sysout LDO Output Voltage Step-Down Buck VOUTBUCK ILIMOUTBUCK RDS(ON)L RDS(ON)H FOSC TS Start-Up Time LDO1 (3.3V) VOUT1 IOUT1 ILIM1 VDO1 VOUT1(VOUT1VIN1) VOUT1 PSRR TS Converter Output Voltage Accuracy P-Channel Current Limit High Side Switch On-Resistance Low Side Switch On-Resistance Oscillator Frequency Output Voltage Accuracy Output Current Output Current Limit Dropout Voltage Line Regulation Load Regulation Power Supply Rejection Ratio Start Up Time Conditions Min CCT = 100nF, VCHGIN = 5V Falling Threshold Hysteresis Rising Threshold Hysteresis 71 318 2.30 Typ 105 3 TC/8 3 75 331 25 2.39 25 115 85 100 Max 79 346 Units %VCS Hours Hours Hours μA mV 2.48 V mV °C °C °C VBAT = 3.6V 100 150 mΩ VCHGIN = 4.5V 0.5 0.75 Ω 3.4 3.9 4.2 V 1.71 1.80 0.8 0.8 0.8 1.5 1.89 V A Ω Ω MHz 4.5 ISYSOUT  900mA, VCHGIN = 4.5V ~ 6.0V IOUTBUCK = 0 ~ 300mA; VIN = 2.7V ~ 5.5V TA = 25°C From Enable to Regulation; COUTBUCK = 4.7μF, CNOISE = On AVIN = 3.7V to 4.2V, IOUT1 = 1mA ~ 300mA IOUT1 = 300mA IOUT1 = 100mA IOUT1 = 0.5mA ~ 150mA IOUT1 = 10mA, COUT1=22μF, 100Hz ~ 10KHz From Enable to Regulation; C OUT1 = 22μF, CNOISE = On V 100 -3 300 μs +3 1000 160 0.07 40 60 320 175 % mA mA mV %/V mV dB μs 1. Specification over the –40°C to +85°C operating temperature range is assured by design, characterization and correlation with statistical process controls. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 202181B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • March 19, 2013 7 DATA SHEET AAT2601B Total Power Solution for Portable Applications Electrical Characteristics1 VIN = 5V, VBAT = 3.6V, -40C ≤ TA ≤ +85C, unless noted otherwise. Typical values are TA = 25C. Symbol Description LDO2, LDO3 VOUT2 IOUT2 ILIM2 VDO2 VOUT2/ (VOUT2VIN2) VOUT2 PSRR Ts Ts Min AVIN = 2.7V to 4.2V, IOUTX = 1mA ~ 150mA -3 150 Typ Max Units +3 (1.2V) Output Voltage Accuracy Output Current Output Current Limit Dropout Voltage IOUT2 = 150mA 1000 150 % mA mA mV Line Regulation IOUT2 = 100mA, 3.3V VUVLO Expired Yes Shut Down Yes Fault Conditions Monitoring OV, OT, VTS1 < VTS < V TS2 Charge Timer Control T < Timeout No Preconditioning Test VBAT < VMIN Yes Preconditioning (Trickle Charge) Thermal Loop Thermal Loop Current Current ReductionininADP Reduction C.C. ModeMode Charging Yes No No Recharge Test VBAT < VRCH Yes Current Phase Test VBAT < VBAT_REG Yes Constant Current Charge Mode Device Thermal Loop Monitor TJ > 115°C No No Voltage Phase Test ICH > ICH_TERM Yes Constant Voltage Charge Mode No Charge Completed Figure 4: System Operation Flow Chart for the Battery Charger. 24 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 202181B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • March 19, 2013 DATA SHEET AAT2601B Total Power Solution for Portable Applications Power Saving Mode After the charge cycle is complete, the battery charger turns off the series pass device and automatically goes into a power saving sleep mode. During this time, the series pass device will block current in both directions to prevent the battery from discharging through the battery charger. The battery charger will remain in sleep mode even if the charger source is disconnected. It will come out of sleep mode if either the battery terminal voltage drops below the VRCH threshold, the charger EN pin is recycled, or the charging source is reconnected. In all cases, the battery charger will monitor all parameters and resume charging in the most appropriate mode. Temperature Sense (TS) The TS pin is available to monitor the battery temperature. Connect a 10k NTC resistor from the TS pin to ground. The TS pin outputs a 75μA constant current into the resistor and monitors the voltage to ensure that the battery temperature does not fall outside the limits depending on the temperature coefficient of the resistor used. When the voltage goes above 2.39V or goes below 0.331V, the charging current will be suspended. in the internal timing control circuit. The constant current provided to charge the timing capacitor is very small, and this pin is susceptible to noise and changes in capacitance value. Therefore, the timing capacitor should be physically located on the printed circuit board layout as close as possible to the CT pin. Since the accuracy of the internal timer is dominated by the capacitance value, a 10% tolerance or better ceramic capacitor is recommended. Ceramic capacitor materials, such as X7R and X5R types, are a good choice for this application. Programming Charge Current (ISET) The default constant current mode charge level is user programmed with a set resistor placed between the ISET pin and ground. The accuracy of the constant charge current, as well as the preconditioning trickle charge current, is dominated by the tolerance of the set resistor. For this reason, a 1% tolerance metal film resistor is recommended for the set resistor function. The constant charge current levels from 100mA to 1A may be set by selecting the appropriate resistor value from Table 1 and Figure 5. The ISET pin current to charging current ratio is 1 to 800. It is regulated to 1.25V during constant current mode unless changed using I2C commands. It can be used as a charging current monitor, based on the equation: Charge Safety Timer (CT) While monitoring the charge cycle, the AAT2601B utilizes a charge safety timer to help identify damaged cells and to ensure that the cell is charged safely. Operation is as follows: upon initiating a charging cycle, the AAT2601B charges the cell at 12% of the programmed maximum charge until VBAT >2.8V. If the cell voltage fails to reach the preconditioning threshold of 2.8V (typ) before the safety timer expires, the cell is assumed to be damaged and the charge cycle terminates. If the cell voltage exceeds 2.8V prior to the expiration of the timer, the charge cycle proceeds into fast charge. There are three timeout periods: 1 hour for Trickle Charge mode, 3 hours for Constant Current mode, and 3 hours for Constant Voltage mode. The CT pin is driven by a constant current source and will provide a linear response to increases in the timing capacitor value. Thus, if the timing capacitor were to be doubled from the nominal 0.1μF value, the time-out periods would be doubled. If the programmable watchdog timer function is not needed, it can be disabled by terminating the CT pin to ground. The CT pin should not be left floating or unterminated, as this will cause errors ICH = 800 ⋅ ⎛ VISET⎞ ⎝ RISET⎠ During preconditioning charge, the ISET pin is regulated to 12% of the fast charge current ISET voltage level (Figure 5), but the equation stays the same. During constant voltage charge mode, the ISET pin voltage will slew down and be directly proportional to the battery current at all times. Constant Charging Current ICH_CC (mA) Set Resistor Value (k) 100 200 300 400 500 600 700 800 900 1000 10 4.99 3.32 2.49 2 1.65 1.43 1.24 1.1 1 Table 1: Constant Current Charge vs. ISET Resistor Value. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 202181B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • March 19, 2013 25 DATA SHEET AAT2601B Total Power Solution for Portable Applications Constant Current Mode Charge Current vs. ISET Resistor ISET Voltage vs. Battery Voltage (CHGIN = 5.0V, RISET = 1.24kΩ Ω) (VIN = 5V; VBAT = 3.6V) 1.4 1400 1.2 1 1000 VISET (V) ICH_CC (mA) 1200 800 600 0.8 0.6 400 0.4 200 0.2 0 0.1 1 10 100 ISET Resistor (kΩ Ω) 0 2.5 2.9 3.3 3.7 4.1 4.5 Battery Voltage (V) Figure 5: Constant Current Mode Charge ICH_CC Setting vs. ISET Resistor and ISET Voltage vs. Battery Voltage. Reverse Battery Leakage CHGIN Bypass Capacitor Selection The AAT2601B includes internal circuitry that eliminates the need for series blocking diodes, reducing solution size and cost as well as dropout voltage relative to conventional battery chargers. When the input supply is removed or when CHGIN goes below the AAT2601B’s under voltage-lockout (UVLO) voltage, or when CHGIN drops below VBAT, the AAT2601B automatically reconfigures its power switches to minimize current drain from the battery. CHGIN is the power input for the AAT2601B battery charger. The battery charger is automatically enabled whenever a valid voltage is present on CHGIN. In most applications, CHGIN is connected to either a wall adapter or USB port. Under normal operation, the input of the charger will often be “hot-plugged” directly to a powered USB or wall adapter cable, and supply voltage ringing and overshoot may appear at the CHGIN pin. A high quality capacitor connected from CHGIN to GND, placed as close as possible to the IC, is sufficient to absorb the energy. Wall-adapter powered applications provide flexibility in input capacitor selection, but the USB specification presents limitations to input capacitance selection. In order to meet both the USB 2.0 and USB OTG (On The Go) specifications while avoiding USB supply under-voltage conditions resulting from the current limit slew rate (100mA/μs) limitations of the USB bus, the CHGIN bypass capacitance value must be between 1μF and 4.7μF. Ceramic capacitors are often preferred for bypassing due to their small size and good surge current ratings, but care must be taken in applications that can encounter hot plug conditions as their very low ESR, in combination with the inductance of the cable, can create a high-Q filter that induces excessive ringing at the CHGIN pin. This ringing can couple to the output and be mistaken as loop instability, or the ringing may be large enough to damage the input itself. Although the CHGIN pin is designed for maximum robustness and an absolute Adapter Power Indicator (ADPP) This is an open drain output which will pull low when VCHGIN > 4.5V. When this happens, depending on the status of the USE_USB pin, the charge current will be reset to the default ISET values or I2C programmed values. Charge Status Output (STAT) The AAT2601B provides battery charging status via a status pin. This pin is a buffered output with a supply level up to the LDO1 output. The status pin can indicate the following conditions: Event Description STAT No battery charging activity Battery charging Charging completed Low (to GND) High (to VOUT1) Low (to GND) Table 2: Charge Status Output (STAT). 26 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 202181B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • March 19, 2013 DATA SHEET AAT2601B Total Power Solution for Portable Applications maximum voltage rating of +6.5V for transients, attention must be given to bypass techniques to ensure safe operation. As a result, design of the CHGIN bypass must take care to “de-Q” the filter. This can be accomplished by connecting a 1 resistor in series with a ceramic capacitor (as shown in Figure 6A), or by bypassing with a tantalum or electrolytic capacitor to utilize its higher ESR to dampen the ringing (as shown in Figure 6B). For additional protection, Zener diodes with 6V clamp voltages may also be used. In any case, it is always critical to evaluate voltage transients at the CHGIN pin with an oscilloscope to ensure safe operation. Thermal Considerations The actual maximum charging current is a function of charge adapter input voltage, the state of charge of the battery at the moment of charge, the system supply current from SYSOUT, and the ambient temperature and the thermal impedance of the package and printed circuit board. The maximum programmable current may not be achievable under all operating parameters. One issue to consider is the amount of current being sourced to the SYSOUT pin from the CHGIN LDO while the battery is being charged. The AAT2601B is offered in a TQFN55-36 package which can provide up to 4W of power dissipation when it is properly bonded to a printed circuit board and has a maximum thermal resistance of 25°C/W. Many considerations should be taken into account when designing the printed circuit board layout, as well as the placement of the charger IC package in proximity to other heat generating devices in a given application design. The ambient temperature around the charger IC will also have an effect on the thermal limits of a battery charging application. The maximum limits that can be expected for a given ambient condition can be estimated by the following discussion. First, the maximum power dissipation for a given situation should be calculated: PD(MAX) = (TJ(MAX) - TA) θJA Where: PD(MAX) = Maximum Power Dissipation (W) θJA = Package Thermal Resistance (°C/W) TJ(MAX) = Maximum Device Junction Temperature (°C) [150°C] TA = Ambient Temperature (°C) CHGIN To USB Port or Wall Adapter To USB Port or Wall Adapter 1Ω CHGIN 4.7μF ESR > 1Ω 1μF Ceramic (XR5/XR7) (A) (B) Figure 6: Hot Plug Requirements. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 202181B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • March 19, 2013 27 DATA SHEET AAT2601B Total Power Solution for Portable Applications Next, the power dissipation for the charger can be calculated by the following equation: PD = (VCHGIN - VBAT) · ICH_CC + (VCHGIN · IOP) + (VCHGIN - VSYSOUT) · ISYSOUT + (VSYSOUT - VOUT1) · IOUT1 + (VSYSOUT - VOUT2) · IOUT2 + (VSYSOUT - VOUT3) · IOUT3 + (VSYSOUT - VOUT4) · IOUT4 + (VSYSOUT - VOUT5) · IOUT5 VOUTBUCK RDS(ON)H · [VSYSOUT - VOUTBUCK]⎞ ⎛ + IOUTBUCK2 · RDS(ON)L · V + ⎝ ⎠ VSYSOUT SYSOUT Where: PD = Total Power Dissipation by the Device VCHGIN = CHGIN Input Voltage VBAT = Battery Voltage at the BAT Pin ICH_CC = Constant Charge Current Programmed for the Application IOP = Quiescent Current Consumed by the IC for Normal Operation [0.5mA] VSYSOUT and ISYSOUT = Output voltage and load current from the SYSOUT pin for the system LDOs and stepdown converter [3.9V out for SYSOUT] RDS(ON)H and RDS(ON)L = On-resistance of step-down high and low side MOSFETs [0.8 each] VOUTX and IOUTX = Output voltage and load currents for the LDOs and step-down converter [3V out for each LDO] By substitution, we can derive the maximum charge current before reaching the thermal limit condition (TREG = 100°C, Thermal Loop Regulation). The maximum charge current is the key factor when designing battery charger applications. ICH_CC(MAX) = ⎛(TREG - TA) ⎞ - (VCHGIN · IOP) - (VCHGIN - VSYSOUT) · ISYSOUT) ⎝ ⎠ θJA - [(VSYSOUT - VOUT1) · IOUT1] - (VSYSOUT - VOUT2) · IOUT2 - [(VSYSOUT - VOUT3) · IOUT3] - (VSYSOUT - VOUT4) · IOUT4 - (VSYSOUT - VOUT5) · IOUT5 VOUTBUCK RDS(ON)H · (VSYSOUT - VOUTBUCK)⎞ ⎛ - IOUTBUCK2 · RDS(ON)L · V + ⎠ VSYSOUT ⎝ SYSOUT VCHGIN - VBAT 28 In general, the worst condition is when there is the greatest voltage drop across the charger, when battery voltage is charged up to just past the preconditioning voltage threshold and the LDOs and step-down converter are sourcing full output current. Thermal Overload Protection The AAT2601B integrates thermal overload protection circuitry to prevent damage resulting from excessive thermal stress that may be encountered under fault conditions, for example. This circuitry disables all regulators if the AAT2601B die temperature exceeds 140°C, and prevents the regulators from being enable until the die temperature drops by 15°C (typ). Synchronous Step-Down Converter (Buck) The AAT2601B contains a high performance 300mA, 1.5MHz synchronous step-down converter. The stepdown converter operates to ensure high efficiency performance over all load conditions. It requires only three external power components (CIN, COUT, and L). A high DC gain error amplifier with internal compensation controls the output. It provides excellent transient response and load/line regulation. Transient response time is typically less than 20μs. The converter has soft start control to limit inrush current and transitions to 100% duty cycle at drop out. The step-down converter input pin PVIN should be connected to the SYSOUT LDO output pin. The output voltage is internally fixed at 1.8V. Power devices are sized for 300mA current capability while maintaining over 90% efficiency at full load. Input/Output Capacitor and Inductor Apart from the input capacitor that is shared with the LDO inputs, only a small L-C filter is required at the output side for the step-down converter to operate properly. Typically, a 3.3μH inductor such as the Sumida CDRH2D11NP3R3NC and a 4.7μF ceramic output capacitor are recommended for low output voltage ripple and small component size. Ceramic capacitors with X5R or X7R dielectrics are highly recommended because of their low ESR and small temperature coefficients. A 10μF ceramic input capacitor is sufficient for most applications. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 202181B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • March 19, 2013 DATA SHEET AAT2601B Total Power Solution for Portable Applications Control Loop Linear LDO Regulators (OUT1-5) The converter is a peak current mode step-down converter. The inner, wide bandwidth loop controls the inductor peak current. The inductor current is sensed through the P-channel MOSFET (high side) which is also used for short circuit and overload protection. A fixed slope compensation signal is added to the sensed current to maintain stability for duty cycles greater than 50%. The peak current mode loop appears as a voltage programmed current source in parallel with the output capacitor. The advanced circuit design of the linear regulators has been specifically optimized for very fast start-up and shutdown timing. These proprietary LDOs are tailored for superior transient response characteristics. These traits are particularly important for applications which require fast power supply timing. The output of the voltage error amplifier programs the current mode loop for the necessary peak inductor current to force a constant output voltage for all load and line conditions. The voltage feedback resistive divider is internal and the error amplifier reference voltage is 0.45V. The voltage loop has a high DC gain making for excellent DC load and line regulation. The internal voltage loop compensation is located at the output of the transconductance voltage error amplifier. Soft Start Soft start slowly increases the internal reference voltage when the input voltage or enable input is initially applied. It limits the current surge seen at the input and eliminates output voltage overshoot. Current Limit and Over-Temperature Protection For overload conditions the peak input current is limited. As load impedance decreases and the output voltage falls closer to zero, more power is dissipated internally, raising the device temperature. Thermal protection completely disables switching when internal dissipation becomes excessive, protecting the device from damage. The junction over-temperature threshold is 140°C with 15°C of hysteresis. The high-speed turn-on capability is enabled through the implementation of a fast start control circuit, which accelerates the power up behavior of fundamental control and feedback circuits within the LDO regulator. For LDO4 and LDO5, fast turn-off time response is achieved by an active output pull down circuit, which is enabled when the LDO regulator is placed in the shutdown mode. This active fast shutdown circuit has no adverse effect on normal device operation. Input/Output Capacitors The LDO regulator output has been specifically optimized to function with low cost, low ESR ceramic capacitors. However, the design will allow for operation over a wide range of capacitor types. The input capacitor is shared with all LDO inputs and the step-down converter. A 10μF is sufficient. A 4.7μF ceramic output capacitor is recommended for LDO2-5 and a 22μF output capacitor for LDO1. Current Limit and Over-Temperature Protection The regulator comes with complete short circuit and thermal protection. The combination of these two internal protection circuits gives a comprehensive safety system to guard against extreme adverse operating conditions. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 202181B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • March 19, 2013 29 DATA SHEET AAT2601B Total Power Solution for Portable Applications I2C Serial Interface and Programmability The timing diagram in Figure 7 depicts the transmission protocol. START and STOP Conditions Serial Interface Many of the features of the AAT2601B can be controlled via the I2C serial interface. The I2C serial interface is a widely used interface where it requires a master to initiate all the communications with the slave devices. The I2C protocol consists of 2 active wire SDA (serial data line) and SCL (serial clock line). Both wires are open drain and require an external pull up resistor to VCC (SYSOUT may be used as VCC). The SDA pin serves I/O function, and the SCL pin controls and references the I2C bus. I2C protocol is a bidirectional bus which allows both read and write actions to take place, but the AAT2601B supports the write protocol only. Since the protocol has a dedicated bit for Read or Write access (R/W), when communicating with AAT2601B, this bit must be set to “0”. ACK from slave START MSB Chip Address 1 0 LSB W ACK MSB START and STOP conditions are always generated by the master. Prior to initiating a START condition, both the SDA and SCL pin are idle mode (idle mode is when there is no activity on the bus and SDA and SCL are pulled to VCC via external resistor). As depicted in Figure 7, a START condition is defined to be when the master pulls the SDA line low and after a short period pulls the SCL line low. A START condition acts as a signal to all IC’s that something is about to be transmitted on the BUS. A STOP condition, also shown in Figure 7, is when the master releases the bus and SCL changes from low to high followed by SDA low to high transition. The master does not issue an ACKNOWLEGE and releases the SCL and SDA pins. ACK from slave Register Address LSB ACK MSB ACK from slave Data LSB ACK STOP SCL SDA 0 1 1 0 0 0 including R/W bit, Chip Address = 0x98 Figure 7: I2C Timing Diagram. 30 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 202181B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • March 19, 2013 DATA SHEET AAT2601B Total Power Solution for Portable Applications Transferring Data Acknowledge Bit Every byte on the bus must be 8 bits long. A byte is always sent with a most significant bit first (see Figure 8). The acknowledge bit is the ninth bit of data. It is used to send back a confirmation to the master that the data has been received properly. For acknowledge to take place, the MASTER must first release the SDA line, then the SLAVE will pull the data line low as shown in Figure 7. R/W LSB MSB Serial Programming Code Figure 8: Bit Order. The address is embedded in the first seven bits of the byte. The eighth bit is reserved for the direction of the information flow for the next byte of information. For the AAT2601B, this bit must be set to “0”. The full 8-bit address including the R/W bit is 0x98 (hex) or 10011000 in binary. After sending the chip address, the master should send an 8-bit data stream to select which register to program and then the codes that the user wishes to enter. Register 0x00: Timer RCHG1 RCHG0 CHG2 CHG1 CHG0 Term1 Term0 Not used Not used Not used Not used SYS LDO11 LDO10 LDO50 LDO41 LDO40 LDO31 LDO30 LDO21 LDO20 Register 0x01: Not used Register 0x02: LDO51 Figure 9: Serial Programming Register Codes. USE_USB Pin CHG2 CHG1 CHG0 1 0 0 0 0 0 0 0 X X X X X X X 0 0 0 1 1 1 1 0 1 1 0 0 1 1 1 0 1 0 1 0 1 Constant Current Charge ICH_CC 100mA (fixed internally) 800mA (set by ISET resistor) 640mA 480mA 320mA 960mA 1120mA 1280mA 1440mA Constant Current Charge as % of ISET Current (default) 100% (default) 80% 60% 40% 120% 140% 160% 180% Table 3: CHG Bit Setting for the Constant Current Charge Level (assuming ISET resistor is set to default 800mA charge current). Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 202181B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • March 19, 2013 31 DATA SHEET AAT2601B Total Power Solution for Portable Applications Notes concerning the operation of the CHG2, CHG1 and CHG0 bits or ISET code: • Once the part is turned on using the EN_KEY pin (and there is a BAT and/or CHGIN supply), and data is sent through I2C, the I2C codes in the registers will always be preserved until the part is shut down using the EN_HOLD (going low) or if the BAT and CHGIN supply are removed. • If the part is turned on by connecting supply CHGIN (and not through EN_KEY), then when the CHGIN is removed, the part will shut down and all I2C registers will be cleared. If USE_USB = L: • The charge current is set by the ISET code in Register 0x00, bits 2,3,4. (code 000 will equal 100%) • If the part has been turned on by EN_KEY and CHGIN is disconnected then reconnected, it will still contain the code it had before (if it was 60% then it will remain 60%). • If the part has NOT been turned on by EN_KEY and CHGIN is disconnected then reconnected, it will be reset to 100% (since the whole part was shutdown). If USE_USB = H: • ISET Code 000 in Register 0x00, bits 2,3,4 = 100mA. The other codes stay the same as if USE_USB=H. • If the part has been turned on by EN_KEY and CHGIN is disconnected then reconnected, the ISET code will be forced to 000 and the current will be set to 100mA. • The next time any I2C register is programmed (even if it is not for the ISET code), the ISET code will revert back to what it was before. For example, if the ISET code is set to 010 and USE_USB=H and the part was turned on with EN_KEY, then when CHGIN is disconnected then reconnected, the charger will be set to 100mA. Then if any other command is sent, the ISET code will remain 010. Term1 Term0 Termination Current (as % of Constant Current Charge) 0 0 1 1 0 1 0 1 5% (default) 10% 15% 20% Table 4: Term Bit Setting for the Termination Current Level. RCHG1 RCHG0 Recharge Threshold 0 0 1 1 0 1 0 1 4.00V (default) 4.05V 4.10V 4.15V Table 5: RCHG Bit Setting for the Battery Charger Recharge Voltage Level. 32 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 202181B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • March 19, 2013 DATA SHEET AAT2601B Total Power Solution for Portable Applications Timer Charger Watchdog Timer 0 1 ON (default) OFF (and reset to zero) Table 6: Timer Bit Setting for the Charger Watchdog Timer. LDO11 LDO10 LDO1 Output Voltage 0 0 1 1 0 1 0 1 3.30V (default) 2.90V 2.85V 2.80V LDO41 LDO40 LDO4 Output Voltage 0 0 1 1 0 1 0 1 3.30V (default) 2.90V 2.85V 2.80V LDO51 LDO50 LDO5 Output Voltage 0 0 1 1 0 1 0 1 3.30V (default) 2.90V 2.85V 2.80V Table 7: LDO Bit Setting for LDO Output Voltage Level. SYS Bit 0 1 Layout Guidance Figure 10 is the schematic for the evaluation board. The evaluation board has extra components for easy evaluation; the actual BOM need for a system is shown in Table 9. When laying out the PC board, the following layout guideline should be followed to ensure proper operation of the AAT2601B: 1. 2. 3. 4. 5. SYSOUT Power Source If USE_USB = H, SYSOUT powered from BAT If USE_USB = L, SYSOUT powered from CHGIN SYSOUT always powered from BAT Table 8: SYS Bit Setting for SYSOUT Power Path. 6. 7. The exposed pad EP must be reliably soldered to PGND/AGND and multilayer GND. The exposed thermal pad should be connected to board ground plane and pins 2 and 16. The ground plane should include a large exposed copper pad under the package with VIAs to all board layers for thermal dissipation. The power traces, including GND traces, the LX traces and the VIN trace should be kept short, direct and wide to allow large current flow. The L1 connection to the LX pins should be as short as possible. Use several via pads when routing between layers. The input capacitors (C1 and C2) should be connected as close as possible to CHGIN (Pin 28) and PGND (Pin 2) to get good power filtering. Keep the switching node LX away from the sensitive OUTBUCK feedback node. The feedback trace for the OUTBUCK pin should be separate from any power trace and connected as closely as possible to the load point. Sensing along a high current load trace will degrade DC load regulation. The output capacitor C4 and L1 should be connected as close as possible and there should not be any signal lines under the inductor. The resistance of the trace from the load return to the PGND (Pin 2) should be kept to a minimum. This will help to minimize any error in DC regulation due to differences in the potential of the internal signal ground and the power ground. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 202181B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • March 19, 2013 33 DATA SHEET AAT2601B Total Power Solution for Portable Applications Quantity Value Designator Footprint Description 5 2 4 3 1 1 9 8 1 10μF 22μF 4.7μF 0.1μF 0.01μF 3.3μH 100K 10K 1.24K C1, C2, C3, C14, C15 C9 C4, C5, C6, C7, C8 C10, C11, C12 C13 L1 R5, R8, R20, R21, R22, R23, R25, R26, R27 R17, R19, R24, R29, R31, R32, R33, R37 R18 0603 0805 0603 0402 0402 CDRH2D 0402 0402 0402 Capacitor, Ceramic, X5R, 6.3V, ±20% Capacitor, Ceramic, 20%, 6.3V, X5R Capacitor, Ceramic, 20%, 6.3V, X5R Capacitor, Ceramic, 16V, 10%, X5R Capacitor, Ceramic, 16V, 10%, X7R Inductor, Sumida CDRH2D11NP-3R3NC Resistor, 5% Resistor, 5% Resistor, 1% Table 9: Minimum AAT2601B Bill of Materials. 34 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 202181B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • March 19, 2013 DATA SHEET AAT2601B Total Power Solution for Portable Applications D1 R30 1K J1 STA T R32 BA T_I D 10K R1 0 USE_USB V DIG PON_N TP11 Sysout 1 3 5 7 9 11 13 15 17 19 21 23 25 LED GREEN 1 2 4 6 8 10 12 14 16 18 20 22 24 26 3 EXT PWR VANA A COK_N VTCXO J12 I NT/EXT PWR 2 J10 R31 RESET_N 1 2 3 4 10K R33 TX _EN PW R_HOLD 10K SDA SCL GND DA TA HEA DER VCORE V BATT TP1 VB ATT Header 13X2H J11 TP2 CHGIN CHG_EN J3 V BATT U1 3 2 CHGIN 28 1 C1 10μF V B US/V CHG R2 0 30 R3 0 29 R4 0 35 36 R6 0 3 2 1 VBATT R7 DNP VD IG R5 100K R8 J2 VTX SDA SCL TCXO_EN VRX A NA_EN 100K V BUS VBA TT V CHG 1 3 5 7 9 11 13 15 17 19 21 23 25 2 4 6 8 10 12 14 16 18 20 22 24 26 R9 0 R10 0 R12 0 R14 0 5 6 7 8 CHGIN BAT BAT 32 B AT_I D SYSOUT SYSOUT A VIN1 A VIN2 PVI N USE_USB SDA SCL EN_KEY EN_HOLD EN_TEST AAT2601B OUT1 OUT2 OUT3 OUT4 OUT5 LX OUTBUCK 31 CT ISET ADPP ON-KEY RESET STAT TS CNOISE R28 PW R_ON RX_EN HF_PW R 4.75K C10 0.1μF Header 13X2H Q1 CMPT3904 C11 0.1μF R17 10K TP10 Sysout 25 24 14 11 22 C12 0.1μF R18 1.24K AGND PGND EP V DIG R19 10K VD IG R20 100K 15 13 12 10 9 20 23 J13 SW 1 PW R_ON RX _EN PW R_ON TX _EN 1 2 3 RX _EN BAT V DIG R24 10K R25 100K J17 HF_PW R 1 2 3 HF_PW R R26 100K USE_USB A NA_EN TCX O_EN R27 100K J19 PWR_HOLD VD IG J9 OUT1 10μF OUT1 OUT2 OUT3 OUT4 OUT5 buckout L1 3.3μH LX 19 4 18 34 17 R11 0 ACOK _N R13 0 PON_N R15 0 RESET_N R16 0 C4 4.7μF C5 4.7μF C6 4.7μF C7 4.7μF C8 4.7μF C9 22μF STAT R29 10K 16 21 37 A COK_N TP3 R37 10K RESET_N TP5 V DIG VCORE STA T_N TP6 1 2 3 ANA _EN CHGIN J18 1 PWR_HOLD 2 3 VANA J8 OUT2 J16 1 2 3 TX_EN CHGIN V TCX O J7 OUT3 R23 100K J15 TCX O_EN VTX J6 OUT4 V DIG R22 100K J14 1 2 3 VRX J5 OUT5 C2 10μF 10μF (TBD) C13 0.01μF VDI G R21 100K J4 BUCK C15 PON_N TP4 BAT C3 10μF Sysout R34 0 R35 0 R36 0 TP9 33 VCORE BA T C14 ENBAT EN2 EN3 EN4 EN5 27 26 1 2 3 CHG_EN USE_USB TP7 GND TP8 GND TP12 GND J20 1 2 3 CHG_EN Figure 10: AAT2601B Evaluation Kit Schematic. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 202181B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • March 19, 2013 35 DATA SHEET AAT2601B Total Power Solution for Portable Applications Figure 11: AAT2601B Evaluation Kit Top Layer. Figure 12: AAT2601B Evaluation Kit Mid1 Layer. 36 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 202181B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • March 19, 2013 DATA SHEET AAT2601B Total Power Solution for Portable Applications Figure 13: AAT2601B Evaluation Kit Mid2 Layer. Figure 14: AAT2601B Evaluation Kit Bottom Layer. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 202181B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • March 19, 2013 37 DATA SHEET AAT2601B Total Power Solution for Portable Applications Ordering Information Package Part Marking1 Part Number (Tape and Reel)2 TQFN55-36 9CXYY AAT2601BIIH-T1 Skyworks Green™ products are compliant with all applicable legislation and are halogen-free. For additional information, refer to Skyworks Definition of Green™, document number SQ04-0074. Packaging Information TQFN55-363 R = 0.1 3.600 ± 0.050 5.000 ± 0.050 Index Area (D/2 x E/2) C = 0.3 5.000 ± 0.050 Detail "A" 3.600 ± 0.050 Bottom View Top View 0.750 ± 0.050 0.450 ± 0.050 0.200 ± 0.050 0.203 REF + 0.050 0.000 - 0.000 Side View 0.40 BSC Detail "A" All dimensions in millimeters. 1. XYY = assembly and date code. 2. Sample stock is generally held on part numbers listed in BOLD. 3. The leadless package family, which includes QFN, TQFN, DFN, TDFN and STDFN, has exposed copper (unplated) at the end of the lead terminals due to the manufacturing process. A solder fillet at the exposed copper edge cannot be guaranteed and is not required to ensure a proper bottom solder connection. 38 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 202181B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • March 19, 2013 DATA SHEET AAT2601B Total Power Solution for Portable Applications Copyright © 2012, 2013 Skyworks Solutions, Inc. All Rights Reserved. Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes. No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions of Sale. THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury, death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any damages resulting from such improper use or sale. Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters. Skyworks, the Skyworks symbol, and “Breakthrough Simplicity” are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands and names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are incorporated by reference. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 202181B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • March 19, 2013 39
AAT2601BIIH-T1 价格&库存

很抱歉,暂时无法提供与“AAT2601BIIH-T1”相匹配的价格&库存,您可以联系我们找货

免费人工找货