    SP-GB-YX-TDA - 60 Km Gigabit Ethernet SFP Transceiver - Source Photonics, Inc.

  • 数据手册
  • 价格&库存
SP-GB-YX-TDA 数据手册
60 Km Gigabit Ethernet SFP Transceiver SP-GB-YX Features • Data rate 1.062 to 1.25 Gb/s • Single 3.3 V supply • 60 km reach • 22 dB min link budget • 1550 nm DFB laser • SFP MSA SFF-8074i compatible • Digital Diagnostic SFF-8472 compliant • Bellcore GR-468 compliant • RoHS-5 compliance (lead exemption) • Color coded bail latch tube: Green General Operating Parameter Supply Voltage Total Current (-CDA) Total Current, Each Power Supply pin, -40ºC to -5ºC (-TDA) Total Current, Each Power Supply pin, -5ºC to -85ºC (-TDA) Power Supply Rejectiona Operating Temperature (-CXX) Operating Temperature (-TXX) Storage Temperature Data Rate GbE Data Rate FC a) 20Hz to 155MHz b) deviations from the MSA Transmitter Specifications (Optical) Parameter Optical Power Average Launch Power Of Off Tx Extinction Ratio (Dynamic) Eye Mask Total Jitter Optical Rise Timeb Optical Fall Timeb Mean Wavelength Spectral Width (20dB) Side Mode Suppression Ratio Optical Path Penalty at 60 Kmc Relative Intensity Noise Reflection Toleranced TJ tr tf λ Δλ SMSR dp RIN rp 1500 30 1550 1 Symbol POP POff Symbol Vcc Icc Icc Icc PSR Top Top Tst DR DR Min. 3.135 100 -5 -40 -40 - Typical 3.3 1250 1062.5 Max. 3.465 300 500 300 70 85 85 - Unit V mA mA mA mVp-p ºC ºC ºC Mbps Mbps Min -2 9 Typical +0.5 - Max +3 -30 802.3 ah compliant 200 260 260 1580 1 2 -120 -24 Unit dBm dBm dB ps ps ps nm nm dB dB dB/Hz dB ER c) 20%-80% values d) Measured at BER of 10-12, PRBS of 27-1, at eye center e) 1dB degradation of receiver sensitivity LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 LUMNDS1559-Jul2406 Rev. A.1 1 60 Km Gigabit Ethernet SFP Transceiver SP-GB-YX Transmitter Specifications (Electical) Parameter Input Differential Impedence PECL Single Ended Data Input Swing TxFault_Fault TxFault_Normal TxDisable_Disable TxDisable_Enable Symbol Rin Vin,p-p Vfault Vnormal Vd Ven Min 80 250 2 Vee 2 Vee Typical 100 Max 120 1200 Vcc Vee+0.5 Vcc Vee+0.8 Unit Ω mV V V V V Receiver Specifications Parameter Receive Power Lowe Receive Power High Damage Threshold For Receiver Wavelength Maximum Reflectance Of Receiver LOS Assert LOS De-assert LOS Hysteresis f) at 10-7BER, PRBS 27-1 Symbol Rsens,low Rsens,high Pin,damage λ RX_r Min -3 1200 -38 0.5 Typical -26 0 Max -24 6 1625 -12 -24 Unit dBm dBm dBm nm dB dBm dBm dB Electrical Output Parameter PECL Single Ended Data Output Swing Data Output Rise Time Data Output Fall Time Timing and Electrical Parameter Tx Disable Negate Time Tx Disable Assert Time Time To Initialize, Including Reset Of Tx Fault Tx Fault Assert Time Tx Disable To Reset LOS Assert Time LOS De-assert Time Serial ID Clock Rate RX_LOS Voltage (High) RX_LOS Voltage (Low) MOD_DEF (0:2)-High MOD_DEF (0:2)-Low LOS Output Voltage-Fault LOS Output Voltage-Normal VH VL VLOS fault VLOSnormal Symbol t_on t_off t_init t_fault t_reset t_loss_on t_loss_off f_serial_clock Min 10 2 2 2 Vee 2 Vee Typical Max 1 10 300 100 100 100 100 Vcc 0.8 Vcc Vee+0.5 Vcc Vee+0.5 Unit ms µs ms µs µs µs µs KHz V V V V V V Symbol Vout, p-p tr tf Min 185 Typical Max 800 260 260 Unit mV ps ps LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 2 LUMNDS1559-Jul2406 Rev. A.1 60 Km Gigabit Ethernet SFP Transceiver SP-GB-YX Diagnostics Parameter Temperature (-CDA) Temperature (-TDA) Voltage Bias Current TX Power RX Power Range -5 to 70 -40 to 85 0 to Vcc 0 to 120 -2 to +3 -24 to -3 Accuracy ±3 ±3 ± 0.1 ±5 ±3 dB ±3 dB Unit ºC ºC V mA dBm dBm Calibration Internal Internal Internal External External External Formula Tc(C)=Tad(16 bit signed twos complement)/256 Tc(C)=Tad(16 bit signed twos complement)/256 V(Volts)=Vad(16 bit unsigned integer)*0.1 I(mA)=Islope*Iad(16 bit unsigned integer)+Ioffset TX_PWR(µW)=TX_PWRslope*TX_PWRad(16 bit unsigned integer +TX_PWRoffset RX_PWR(µW)=A0+A1*x+A2*x^2+A3*x^3+A4*x^4 EEPROM Serial ID Name of Field Description of Field Address 20 21 22 23 24 Vendor Name SFP Vendor Name(ASCII) 25 26 27 28 29 30 37 Vendor OUI IEEE Vendor OUI Code For LuminentOIC Inc. 38 39 40 41 42 Vendor PN Part Number in ASCII, e.g. SP-GB-YX-CDA 43 44 45 46 47 48 Hex 4C 55 4D 49 4E 45 4E 54 4F 49 43 00 06 B5 53 50 47 42 59 58 43 44 41 S P G B Y X C D A ASCII L U M I N E N T O I C LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 3 LUMNDS1559-Jul2406 Rev. A.1 60 Km Gigabit Ethernet SFP Transceiver SP-GB-YX Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Function VeeT TX_FAULT TX_DISABLE MOD_DEF2 MOD_DEF1 MOD_DEF0 NC LOS Notes TX GND Open Collector Internally Pulled High Serial Data Input Serial Clock Input Internally Grounded Not Connected Open Collector RX Ground RX Ground RX Ground RX Data Negative RX Data Positive RX GND RX Power Supply TX Power Supply TX GND TX Data Positive TX Data Negative TX GND VeeR VeeR VeeR RXDRXD+ VeeR VccR VccT VeeT TXD+ TXDVeeT LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 4 LUMNDS1559-Jul2406 Rev. A.1 60 Km Gigabit Ethernet SFP Transceiver SP-GB-YX Outline Drawing Units in mm(inch) LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 5 LUMNDS1559-Jul2406 Rev. A.1 60 Km Gigabit Ethernet SFP Transceiver SP-GB-YX Suggested Transceiver Interface 1�H Vcc 10�F 0.1�F 1�H .01�F VCCT Protocol IC R1 TX_DISABLE 10K� TX_DISABLE LuminentOIC SFP TX_FAULT TX_FAULT Laser Driver .01�F SerDes TD + 100� TD VEET .01�F VCCR 10�F 0.1�F RD + Receiver Amplifier .01�F 100� RD - RX_LOS Vcc RX_LOS R 1 .01�F VEER EEPROM R1 R1 R1 MOD_DEF 2 MOD_DEF 1 R1=4.7K to 10K� MOD_DEF 0 LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 6 LUMNDS1559-Jul2406 Rev. A.1 60 Km Gigabit Ethernet SFP Transceiver SP-GB-YX Ordering Information Available Options: SP-GB-YX-CDA SP-GB-YX-CNA SP-GB-YX-TDA SP-GB-YX-TNA Part numbering Definition: SP - GB - YX - Temperature Diagnostic Revision • SP = Small Form Pluggable GB = 1.25 Gbps YX = Extended Reach 60 km • Operating Temperature C = Commercial (-5 to 70ºC) T = Industrial (-40 to 85ºC) • D = Digital Diagnostic (SFF-8472) N = No Digital Diagnostic • Design Revision Warnings: Handling Precautions: This device is susceptible to damage as a result of electrostatic discharge (ESD). A static free environment is highly recommended. Follow guidelines according to proper ESD procedures. Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect radiation. Legal Notes: IMPORTANT NOTICE! All information contained in this document is subject to change without notice, at LuminentOIC’s sole and absolute discretion. LuminentOIC warrants performance of its products to current specifications only in accordance with the company’s standard one-year warranty; however, specifications designated as “preliminary” are given to describe components only, and LuminentOIC expressly disclaims any and all warranties for said products, including express, implied, and statutory warranties, warranties of merchantability, fitness for a particular purpose, and non-infringement of proprietary rights. Please refer to the company’s Terms and Conditions of Sale for further warranty information. LuminentOIC assumes no liability for applications assistance, customer product design, software performance, or infringement of patents, services, or intellectual property described herein. No license, either express or implied, is granted under any patent right, copyright, or intellectual property right, and LuminentOIC makes no representations or warranties that the product(s) described herein are free from patent, copyright, or intellectual property rights. Products described in this document are NOT intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. LuminentOIC customers using or selling products for use in such applications do so at their own risk and agree to fully defend and indemnify LuminentOIC for any damages resulting from such use or sale. THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROVIDED ON AN “AS IS” BASIS. Customer agrees that LuminentOIC is not liable for any actual, consequential, exemplary, or other damages arising directly or indirectly from any use of the information contained in this document. Customer must contact LuminentOIC to obtain the latest version of this publication to verify, before placing any order, that the information contained herein is current. © LuminentOIC, Inc. 2003 All rights reserved LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 7 LUMNDS1559-Jul2406 Rev. A.1
SP-GB-YX-TDA 价格&库存

很抱歉,暂时无法提供与“SP-GB-YX-TDA”相匹配的价格&库存,您可以联系我们找货

免费人工找货