M41T00SM6E

M41T00SM6E

  • 厂商:

    STMICROELECTRONICS(意法半导体)

  • 封装:

    SOICN8_150MIL

  • 描述:

    IC RTC CLK/CALENDAR I2C 8-SOIC

  • 数据手册
  • 价格&库存
M41T00SM6E 数据手册
M41T00S Serial real-time clock Datasheet - production data Description The M41T00S is a low-power serial real-time clock (RTC) with a built-in 32.768 kHz oscillator (external crystal controlled). Eight bytes of the SRAM are used for the clock/calendar function and are configured in binary coded decimal (BCD) format. Addresses and data are transferred serially via a two line, bidirectional I²C interface. 8 1 SO8, 8-pin SOIC The built-in address register is incremented automatically after each WRITE or READ data byte. Features • 2.0 to 5.5 V clock operating voltage • Counters for seconds, minutes, hours, day, date, month, year, and century • Software clock calibration • Automatic switchover and deselect circuitry (fixed reference) • VCC = 2.7 to 5.5 V 2.5 V ≤ VPFD ≤ 2.7 V • Serial interface supports I²C bus (400 kHz protocol) • Low operating current of 300 mA The M41T00S has a built-in power sense circuit which detects power failures and automatically switches to the battery supply when a power failure occurs. The energy needed to sustain the clock operations can be supplied by a small lithium button supply when a power failure occurs. The eight clock address locations contain the century, year, month, date, day, hour, minute, and second in 24-hour BCD format. Corrections for 28, 29 (leap year - valid until year 2100), 30 and 31 day months are made automatically. The M41T00S is supplied in an 8-pin SOIC. • Oscillator stop detection • Battery or SuperCapTM backup • Operating temperature of - 40 to 85 °C • Ultra-low battery supply current of 0.6 mA October 2021 This is information on a product in full production. DocID10772 Rev 6 1/28 www.st.com 28 Contents M41T00S Contents 1 Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 2 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 2.1 3 2-wire bus characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 2.1.1 Bus not busy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 2.1.2 Start data transfer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 2.1.3 Stop data transfer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 2.1.4 Data valid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 2.1.5 Acknowledge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 2.2 READ mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 2.3 WRITE mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 2.4 Data retention mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 Clock operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 3.1 Clock registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 3.2 Calibrating the clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 3.2.1 Century bit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 3.2.2 Oscillator fail detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 3.2.3 Output driver pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 3.2.4 Preferred initial power-on default . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 4 Maximum ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 5 DC and AC parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 6 Package mechanical information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 7 Part numbering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 8 Revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 2/28 DocID10772 Rev 6 M41T00S List of figures List of figures Figure 1. Figure 2. Figure 3. Figure 4. Figure 5. Figure 6. Figure 7. Figure 8. Figure 9. Figure 10. Figure 11. Figure 12. Figure 13. Figure 14. Figure 15. Figure 16. Figure 17. Logic diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 8-pin SOIC connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Serial bus data transfer sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Acknowledgement sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Slave address location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 READ mode sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Alternative READ mode sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 WRITE mode sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Crystal accuracy across temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Clock calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 AC measurement I/O waveform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Power down/up mode AC waveforms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Bus timing requirements sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 SO8 – 8-lead plastic small package outline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Carrier tape for SO8 (150 mils body width) package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Reel schematic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 DocID10772 Rev 6 3/28 List of tables M41T00S List of tables Table 1. Table 2. Table 3. Table 4. Table 5. Table 6. Table 7. Table 8. Table 9. Table 10. Table 11. Table 12. Table 13. Table 14. Table 15. Table 16. 4/28 Signal names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 TIMEKEEPER® register map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Preferred default values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Absolute maximum ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Operating and AC measurement conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Capacitance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 DC characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Crystal electrical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Power down/up AC characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Power down/up trip points DC characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 AC characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 SO8 – 8-lead plastic small outline (150 mils body width), package mechanical data. . . . . 23 Carrier tape dimensions for SO8 (150 mils body width) package. . . . . . . . . . . . . . . . . . . . 24 Reel dimensions for 12 mm carrier tape - SO8 package (150 mils body width) . . . . . . . . . 25 Ordering information scheme . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Document revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 DocID10772 Rev 6 M41T00S 1 Diagram Diagram Figure 1. Logic diagram VCC VBAT XI XO M41T00S FT/OUT SCL SDA VSS AI09165 Table 1. Signal names XI Oscillator input XO Oscillator output FT/OUT Frequency test / output driver (open drain) SDA Serial data input/output SCL Serial clock input VBAT Battery supply voltage VCC Supply voltage VSS Ground Figure 2. 8-pin SOIC connections XI XO VBAT VSS 1 8 7 2 3 M41T00S 6 4 5 VCC FT/OUT(1) SCL SDA AI09166 1. Open drain output DocID10772 Rev 6 5/28 Diagram M41T00S Figure 3. Block diagram REAL TIME CLOCK CALENDAR 32KHz OSCILLATOR CRYSTAL OSCILLATOR FAIL CIRCUIT RTC & CALIBRATION FREQUENCY TEST SDA I2C INTERFACE SCL OUTPUT DRIVER WRITE PROTECT VCC FT FT/OUT(1) OUT INTERNAL POWER VBAT VSO COMPARE VPFD AI09168 1. Open drain output 6/28 DocID10772 Rev 6 M41T00S 2 Operation Operation The M41T00S clock operates as a slave device on the serial bus. Access is obtained by implementing a start condition followed by the correct slave address (D0h). The 8 bytes contained in the device can then be accessed sequentially in the following order: 1. Seconds register 2. Minutes register 3. Century/hours register 4. Day register 5. Date register 6. Month register 7. Year register 8. Calibration register The M41T00S clock continually monitors VCC for an out-of-tolerance condition. Should VCC fall below VPFD, the device terminates an access in progress and resets the device address counter. Inputs to the device will not be recognized at this time to prevent erroneous data from being written to the device from a an out-of-tolerance system. Once VCC falls below the switchover voltage (VSO), the device automatically switches over to the battery and powers down into an ultra-low current mode of operation to preserve battery life. Upon power-up, the device switches from battery to VCC at VSO. When VCC rises above VPFD, it will recognize the inputs. For more information on battery storage life refer to application note AN1012. 2.1 2-wire bus characteristics The bus is intended for communication between different ICs. It consists of two lines: a bidirectional data signal (SDA) and a clock signal (SCL). Both the SDA and SCL lines must be connected to a positive supply voltage via a pull-up resistor. The following protocol has been defined: • Data transfer may be initiated only when the bus is not busy. • During data transfer, the data line must remain stable whenever the clock line is high. • Changes in the data line, while the clock line is high, will be interpreted as control signals. Accordingly, the following bus conditions have been defined: DocID10772 Rev 6 7/28 Operation 2.1.1 M41T00S Bus not busy Both data and clock lines remain high. 2.1.2 Start data transfer A change in the state of the data line, from high to low, while the clock is high, defines the START condition. 2.1.3 Stop data transfer A change in the state of the data line, from low to high, while the clock is high, defines the STOP condition. 2.1.4 Data valid The state of the data line represents valid data when after a start condition, the data line is stable for the duration of the high period of the clock signal. The data on the line may be changed during the low period of the clock signal. There is one clock pulse per bit of data. Each data transfer is initiated with a start condition and terminated with a stop condition. The number of data bytes transferred between the start and stop conditions is not limited. The information is transmitted byte-wide and each receiver acknowledges with a ninth bit. By definition a device that gives out a message is called “transmitter,” the receiving device that gets the message is called “receiver.” The device that controls the message is called “master.” The devices that are controlled by the master are called “slaves.” 2.1.5 Acknowledge Each byte of eight bits is followed by one acknowledge bit. this acknowledge bit is a low level put on the bus by the receiver whereas the master generates an extra acknowledge related clock pulse. A slave receiver which is addressed is obliged to generate an acknowledge after the reception of each byte that has been clocked out of the slave transmitter. The device that acknowledges has to pull down the SDA line during the acknowledge clock pulse in such a way that the SDA line is a stable low during the high period of the acknowledge related clock pulse. Of course, setup and hold times must be taken into account. A master receiver must signal an end of data to the slave transmitter by not generating an acknowledge on the last byte that has been clocked out of the slave. In this case the transmitter must leave the data line high to enable the master to generate the STOP condition. 8/28 DocID10772 Rev 6 M41T00S Operation Figure 4. Serial bus data transfer sequence DATA LINE STABLE DATA VALID CLOCK DATA START CONDITION CHANGE OF DATA ALLOWED STOP CONDITION AI00587 Figure 5. Acknowledgement sequence CLOCK PULSE FOR ACKNOWLEDGEMENT START SCL FROM MASTER DATA OUTPUT BY TRANSMITTER 1 2 MSB 8 9 LSB DATA OUTPUT BY RECEIVER AI00601 2.2 READ mode In this mode the master reads the M41T00S slave after setting the slave address (see Figure 7 on page 10). Following the WRITE mode control bit (R/W=0) and the acknowledge bit, the word address 'An' is written to the on-chip address pointer. Next the START condition and slave address are repeated followed by the READ mode control bit (R/W=1). At this point the master transmitter becomes the master receiver. The data byte which was addressed will be transmitted and the master receiver will send an acknowledge bit to the slave transmitter. The address pointer is only incremented on reception of an acknowledge clock. The M41T00S slave transmitter will now place the data byte at address An+1 on the bus, the master receiver reads and acknowledges the new byte and the address pointer is incremented to “An+2.” This cycle of reading consecutive addresses will continue until the master receiver sends a STOP condition to the slave transmitter. The system-to-user transfer of clock data will be halted whenever the address being read is a clock address (00h to 06h). The update will resume due to a stop condition or when the pointer increments to any non-clock address (07h). Note: This is true both in READ mode and WRITE mode. DocID10772 Rev 6 9/28 Operation M41T00S An alternate READ mode may also be implemented whereby the master reads the M41T00S slave without first writing to the (volatile) address pointer. The first address that is read is the last one stored in the pointer (see Figure 8 on page 10). Figure 6. Slave address location R/W START A 1 LSB MSB SLAVE ADDRESS 1 0 1 0 0 0 AI00602 SLAVE ADDRESS DATA n+1 ACK DATA n ACK S ACK BUS ACTIVITY: R/W START WORD ADDRESS (An) ACK S R/W SDA LINE ACK BUS ACTIVITY: MASTER START Figure 7. READ mode sequence STOP SLAVE ADDRESS DATA n+X P NO ACK AI00899 STOP R/W SLAVE ADDRESS 10/28 DATA n+X P NO ACK BUS ACTIVITY: DATA n+1 ACK DATA n ACK S ACK SDA LINE ACK BUS ACTIVITY: MASTER START Figure 8. Alternative READ mode sequence AI00895 DocID10772 Rev 6 M41T00S 2.3 Operation WRITE mode In this mode the master transmitter transmits to the M41T00S slave receiver. Bus protocol is shown in Figure 9. Following the START condition and slave address, a logic '0' (R/W=0) is placed on the bus and indicates to the addressed device that word address “An” will follow and is to be written to the on-chip address pointer. The data word to be written to the memory is strobed in next and the internal address pointer is incremented to the next address location on the reception of an acknowledge clock. The M41T00S slave receiver will send an acknowledge clock to the master transmitter after it has received the slave address see Figure 6 on page 10 and again after it has received the word address and each data byte. Data retention mode With valid VCC applied, the M41T00S can be accessed as described above with READ or WRITE cycles. Should the supply voltage decay, the power input will be switched from the VCC pin to the battery when VCC falls below the battery backup switchover voltage (VSO). At this time the clock registers will be maintained by the attached battery supply. On power-up, when VCC returns to a nominal value, write protection continues for tREC. For a further, more detailed review of lifetime calculations, please see Application Note AN1012. SLAVE ADDRESS DATA n+X P ACK DATA n+1 ACK BUS ACTIVITY: DATA n ACK WORD ADDRESS (An) ACK S R/W SDA LINE ACK BUS ACTIVITY: MASTER STOP Figure 9. WRITE mode sequence START 2.4 AI00591 DocID10772 Rev 6 11/28 Clock operation 3 M41T00S Clock operation The 8-byte register map (see Table 2) is used to both set the clock and to read the date and time from the clock, in a binary coded decimal format. Seconds, minutes, and hours are contained within the first three registers. Bits D6 and D7 of clock register 02h (century/hours register) contain the CENTURY ENABLE bit (CEB) and the CENTURY bit (CB). Setting CEB to a '1' will cause CB to toggle, either from '0' to '1' or from '1' to '0' at the turn of the century (depending upon its initial state). If CEB is set to a '0,' CB will not toggle. Bits D0 through D2 of Register 03h contain the Day (day of week). Registers 04h, 05h, and 06h contain the date (day of month), month and years. The eighth clock register is the calibration register (this is described in the clock calibration section). Bit D7 of register 00h contains the STOP bit (ST). Setting this bit to a '1' will cause the oscillator to stop. If the device is expected to spend a significant amount of time on the shelf, the oscillator may be stopped to reduce current drain. When reset to a '0' the oscillator restarts within one second. The seven clock registers may be read one byte at a time, or in a sequential block. The calibration register (address location 07h) may be accessed independently. Provision has been made to assure that a clock update does not occur while any of the seven clock addresses are being read. If a clock address is being read, an update of the clock registers will be halted. This will prevent a transition of data during the READ. 3.1 Clock registers The M41T00S offers 8 internal registers which contain clock and calibration data. These registers are memory locations which contain external (user accessible) and internal copies of the data (usually referred to as BiPORT™ TIMEKEEPER cells). The external copies are independent of internal functions except that they are updated periodically by the simultaneous transfer of the incremented internal copy. The internal divider (or clock) chain will be reset upon the completion of a WRITE to any clock address. The system-to-user transfer of clock data will be halted whenever the address being read is a clock address (00h to 06h). The update will resume either due to a stop condition or when the pointer increments to any non-clock address (07h). Clock registers store data in BCD. The calibration register stores data in binary format. 12/28 DocID10772 Rev 6 M41T00S Clock operation Table 2. TIMEKEEPER® register map Addr Function/range BCD format D7 D6 D5 D4 D3 D2 D1 D0 00h ST 10 seconds Seconds Seconds 00-59 01h OF 10 minutes Minutes Minutes 00-59 02h CEB CB Hours (24-hour format) Century/hours 0-1/00-23 03h 0 0 Day 01-7 04h 0 0 Date: day of month Date 01-31 05h 0 0 Month Month 01-12 Year Year 00-99 06h 07h 10 hours 0 0 0 10 date 0 10M 10 years OUT FT S Day of week Calibration Calibration Keys: 0 = must be set to '0' CB = century bit CEB = century enable bit FT = frequency test bit OF = oscillator fail bit OUT = output level S = sign bit ST = stop bit 3.2 Calibrating the clock The M41T00S is driven by a quartz-controlled oscillator with a nominal frequency of 32,768 Hz. The devices are tested not exceed ±35 ppm (parts per million) oscillator frequency error at 25oC, which equates to about ±1.53 minutes per month (see Figure 10 on page 15). When the calibration circuit is properly employed, accuracy improves to better than ±2 ppm at 25°C. The oscillation rate of crystals changes with temperature. The M41T00S design employs periodic counter correction. The calibration circuit adds or subtracts counts from the oscillator divider circuit at the divide by 256 stage, as shown in Figure 11 on page 15. The number of times pulses which are blanked (subtracted, negative calibration) or split (added, positive calibration) depends upon the value loaded into the five calibration bits found in the calibration register. Adding counts speeds the clock up, subtracting counts slows the clock down. The calibration bits occupy the five lower order bits (D4-D0) in the calibration register 07h. These bits can be set to represent any value between 0 and 31 in binary form. Bit D5 is a Sign bit; '1' indicates positive calibration, '0' indicates negative calibration. Calibration occurs within a 64 minute cycle. The first 62 minutes in the cycle may, once per minute, have one second either shortened by 128 or lengthened by 256 oscillator cycles. If a binary '1' is loaded into the register, only the first 2 minutes in the 64 minute cycle will be modified; if a binary 6 is loaded, the first 12 will be affected, and so on. DocID10772 Rev 6 13/28 Clock operation M41T00S Therefore, each calibration step has the effect of adding 512 or subtracting 256 oscillator cycles for every 125,829,120 actual oscillator cycles, that is +4.068 or –2.034 ppm of adjustment per calibration step in the calibration register (see Figure 11 on page 15). Assuming that the oscillator is running at exactly 32,768 Hz, each of the 31 increments in the calibration byte would represent +10.7 or –5.35 seconds per month which corresponds to a total range of +5.5 or –2.75 minutes per month. Two methods are available for ascertaining how much calibration a given M41T00S may require. The first involves setting the clock, letting it run for a month and comparing it to a known accurate reference and recording deviation over a fixed period of time. Calibration values, including the number of seconds lost or gained in a given period, can be found in application note AN934, “TIMEKEEPER® calibration.” This allows the designer to give the end user the ability to calibrate the clock as the environment requires, even if the final product is packaged in a non-user serviceable enclosure. The designer could provide a simple utility that accesses the calibration byte. The second approach is better suited to a manufacturing environment, and involves the use of the FT/OUT pin. The pin will toggle at 512 Hz, when the Stop bit (ST, D7 of 00h) is '0,' and the Frequency Test bit (FT, D6 of 07h) is '1.' Any deviation from 512 Hz indicates the degree and direction of oscillator frequency shift at the test temperature. For example, a reading of 512.010124 Hz would indicate a +20 ppm oscillator frequency error, requiring a –10 (XX001010) to be loaded into the calibration byte for correction. Note that setting or changing the calibration byte does not affect the frequency test output frequency. The FT/OUT pin is an open drain output which requires a pull-up resistor to VCC for proper operation. A 500-10k resistor is recommended in order to control the rise time. The FT bit is cleared on power-down. Note: 14/28 The Frequency test is not available in battery mode. DocID10772 Rev 6 M41T00S Clock operation Figure 10. Crystal accuracy across temperature Frequency (ppm) 20 0 –20 –40 –60 ∆F = K x (T – T )2 O F –80 2 2 K = –0.036 ppm/°C ± 0.006 ppm/°C –100 TO = 25°C ± 5°C –120 –140 –160 –40 –30 –20 –10 0 10 20 30 40 50 60 70 80 Temperature °C AI07888 Figure 11. Clock calibration NORMAL POSITIVE CALIBRATION NEGATIVE CALIBRATION AI00594B 3.2.1 Century bit Bits D7 and D6 of clock register 02h contain the CENTURY ENABLE bit (CEB) and the CENTURY bit (CB). Setting CEB to a '1' will cause CB to toggle, either from a '0' to '1' or from '1' to '0' at the turn of the century (depending upon its initial state). If CEB is set to a '0,' CB will not toggle. 3.2.2 Oscillator fail detection If the Oscillator Fail bit (OF) is internally set to '1,' this indicates that the oscillator has either stopped, or was stopped for some period of time and can be used to judge the validity of the clock and date data. DocID10772 Rev 6 15/28 Clock operation M41T00S In the event the OF bit is found to be set to '1' at any time other than the initial power-up, the STOP bit (ST) should be written to a '1,' then immediately reset to '0.' This will restart the oscillator. The following conditions can cause the OF bit to be set: • The first time power is applied (defaults to a '1' on power-up). • The voltage present on VCC is insufficient to support oscillation. • The ST bit is set to '1.' • External interference of the crystal. The OF bit will remain set to '1' until written to logic '0.' The oscillator must start and have run for at least 4 seconds before attempting to reset the OF Bit to '0.' 3.2.3 Output driver pin When the FT bit is not set, the FT/OUT pin becomes an output driver that reflects the contents of D7 of the calibration register. In other words, when D7 (OUT bit) and D6 (FT bit) of address location 07h are a '0,' then the FT/OUT pin will be driven low. Table 3. FT/OUT pin status Power mode (FT) D6 of 07h (OUT bit) D7 of 07h Status 0 0 Low 0 1 High 1 1 or 0 Frequency Test N.A. N.A. High VCC Mode Battery Mode Note: The FT/OUT pin is an open drain which requires an external pull-up resistor. 3.2.4 Preferred initial power-on default Upon initial application of power to the device, the ST and FT bits are set to a '0' state, and the OF and OUT bits will be set to a '1.' All other register bits will initially power-on in a random state (see Table 4). Table 4. Preferred default values Condition Initial power-up(1) Subsequent power-up (with battery backup)(2) 1. State of other control bits undefined. 2. UC = Unchanged 16/28 DocID10772 Rev 6 ST Out FT OF 0 1 0 1 UC UC 0 UC M41T00S 4 Maximum ratings Maximum ratings Stressing the device above the rating listed in the absolute maximum ratings table may cause permanent damage to the device. These are stress ratings only and operation of the device at these or any other conditions above those indicated in the operating sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. Table 5. Absolute maximum ratings Sym Parameter TSTG Storage temperature (VCC off, oscillator off) VCC Supply voltage TSLD(1) Lead solder temperature for 10 seconds Value Unit –55 to 125 °C –0.3 to 7 V 260 °C –0.3 to VCC+0.3 V VIO Input or output voltages IO Output current 20 mA PD Power dissipation 1 W 1. Reflow at peak temperature of 260 °C (total thermal budget not to exceed 245 °C for greater than 30 seconds). Caution: Negative undershoots below -0.3 volts are not allowed on any pin while in the battery backup mode DocID10772 Rev 6 17/28 DC and AC parameters 5 M41T00S DC and AC parameters This section summarizes the operating and measurement conditions, as well as the DC and AC characteristics of the device. The parameters in the following DC and AC Characteristic tables are derived from tests performed under the Measurement Conditions listed in the relevant tables. Designers should check that the operating conditions in their projects match the measurement conditions when using the quoted parameters. Table 6. Operating and AC measurement conditions Parameter Note: M41T00S Supply voltage (VCC) 2.7 to 5.5 V Ambient operating temperature (TA) –40 to 85 °C Load capacitance (CL) 100 pF Input rise and fall times ≤ 50 ns Input pulse voltages 0.2VCC to 0.8VCC Input and output timing ref. voltages 0.3VCC to 0.7VCC Output Hi-Z is defined as the point where data is no longer driven. Figure 12. AC measurement I/O waveform 0.8VCC 0.7VCC 0.3VCC 0.2VCC AI02568 Table 7. Capacitance Parameter(1)(2) Symbol CIN COUT tLP (3) Min Max Unit Input capacitance - 7 pF Output capacitance - 10 pF Low-pass filter input time constant (SDA and SCL) - 50 ns 1. Effective capacitance measured with power supply at 5V; sampled only, not 100% tested. 2. At 25 °C, f = 1 MHz 3. Outputs deselected. 18/28 DocID10772 Rev 6 M41T00S DC and AC parameters Table 8. DC characteristics Sym Test condition(1) Parameter ILI Input leakage current ILO Output leakage current ICC1 Supply current Min Typ Max Unit 0 V ≤ VIN ≤ VCC ±1 µA 0 V ≤ VOUT ≤ VCC ±1 µA Switch freq = 400 kHz 300 µA SCL = 0 Hz All Inputs ≥ VCC – 0.2 V ≤ VSS + 0.2 V 70 µA ICC2 Supply current (standby) VIL Input low voltage –0.3 0.3VCC V VIH Input high voltage 0.7VCC VCC + 0.3 V IOL = 3.0 mA 0.4 V IOL = 10 mA 0.4 V FT/OUT 5.5 V Output low voltage VOL Output low voltage (open drain)(2) Pull-up supply voltage (open drain) VBAT (3) IBAT Backup supply voltage Battery supply current 2.0 TA = 25 °C, VCC = 0 V Oscillator ON, VBAT = 3 V 3.5 0.6 (4) V 1 µA Max Unit kHz 60(3) kΩ 1. Valid for ambient operating temperature: TA = –40 to 85 °C; VCC = 2.7 to 5.5 V (except where noted). 2. For FT/OUT pin (open drain). 3. STMicroelectronics recommends the RAYOVAC BR1225 or BR1632 (or equivalent) as the battery supply. 4. For rechargeable backup, VBAT (max) may be considered to be VCC. Table 9. Crystal electrical characteristics fO Parameter(1)(2) Resonant frequency RS Series resistance CL Load capacitance Sym Min Typ 32.768 12.5 pF 1. Externally supplied if using the SO8 package. STMicroelectronics recommends the KDS DT-38: 1TA/1TC252E127, Tuning Fork Type (thru-hole) or the DMX-26S: 1TJS125FH2A212, (SMD) quartz crystal for industrial temperature operations. KDS can be contacted at kouhou@kdsj.co.jp or http://www.kdsj.co.jp for further information on this crystal type. 2. Load capacitors are integrated within the M41T00S. Circuit board layout considerations for the 32.768 kHz crystal of minimum trace lengths and isolation from RF generating signals should be taken into account. 3. For applications requiring backup supply operation below 2.5 V, RS (max) should be considered 40 kΩ. DocID10772 Rev 6 19/28 DC and AC parameters M41T00S Figure 13. Power down/up mode AC waveforms VCC VSO tPD trec SDA SCL DON'T CARE AI00596 Table 10. Power down/up AC characteristics Symbol tPD trec Parameter(1)(2) SCL and SDA at VIH before power-down Min 0 SCL and SDA at VIH after power-up Typ Max Unit nS 10 µS 1. VCC fall time should not exceed 5 mV/µs. 2. Valid for ambient operating temperature: TA = –40 to 85 °C; VCC = 2.7 to 5.5 V (except where noted). Table 11. Power down/up trip points DC characteristics Parameter(1)(2) Sym VPFD VSO Power-fail deselect Min Typ Max Unit 2.5 2.6 2.7 V Hysteresis Battery backup switchover voltage (VCC < VBAT; VCC < VPFD) 25 mV VBAT < VPFD VBAT V VBAT > VPFD VPFD V 40 mV Hysteresis 1. All voltages referenced to VSS. 2. Valid for ambient operating temperature: TA = –40 to 85 °C; VCC = 2.7 to 5.5 V (except where noted). Figure 14. Bus timing requirements sequence SDA tBUF tHD:STA tHD:STA tR tF SCL tHIGH P S tLOW tSU:DAT tHD:DAT tSU:STA SR tSU:STO P AI00589 20/28 DocID10772 Rev 6 M41T00S DC and AC parameters Table 12. AC characteristics Parameter(1) Sym Min 0 Typ Max Units 400 kHz fSCL SCL clock frequency tLOW Clock low period 1.3 µs tHIGH Clock high period 600 ns tR SDA and SCL rise time 300 ns tF SDA and SCL fall time 300 ns tHD:STA START condition hold time (after this period the first clock pulse is generated) 600 ns tSU:STA START condition setup time (only relevant for a repeated start condition) 600 ns Data setup time 100 ns tHD:DAT Data hold time 0 µs tSU:STO STOP condition setup time 600 ns Time the bus must be free before a new transmission can start 1.3 µs tSU:DAT tBUF (2) 1. Valid for ambient operating temperature: TA = –40 to 85 °C; VCC = 2.7 to 5.5 V (except where noted). 2. Transmitter must internally provide a hold time to bridge the undefined region (300 ns max) of the falling edge of SCL. DocID10772 Rev 6 21/28 Package mechanical information 6 M41T00S Package mechanical information In order to meet environmental requirements, ST offers these devices in different grades of ECOPACK packages, depending on their level of environmental compliance. ECOPACK specifications, grade definitions and product status are available at: www.st.com. ECOPACK is an ST trademark. 22/28 DocID10772 Rev 6 M41T00S Package mechanical information Figure 15. SO8 – 8-lead plastic small package outline h x 45˚ A2 A c ccc b e 0.25 mm GAUGE PLANE D k 8 E1 E 1 L A1 L1 SO-A Note: Drawing is not to scale. Table 13. SO8 – 8-lead plastic small outline (150 mils body width), package mechanical data mm inches Symb Typ Min A Max Typ Min 1.75 Max 0.069 A1 0.10 0.25 0.004 0.010 A2 1.25 B 0.28 0.48 0.011 0.019 C 0.17 0.23 0.007 0.009 0.049 D 4.90 4.80 5.00 0.189 0.197 E 6.00 5.80 6.20 0.228 0.244 E1 3.90 3.80 4.00 0.150 0.157 e 1.27 0.050 h 0.25 0.50 0.010 0.020 L 0.40 1.27 0.016 0.050 0° 8° L1 1.04 0.041 k 0° N 8 ccc 8° 8 0.10 DocID10772 Rev 6 0.004 23/28 Package mechanical information M41T00S Figure 16. Carrier tape for SO8 (150 mils body width) package P0 E P2 D T A0 F TOP COVER TAPE W B0 P1 CENTER LINES OF CAVITY K0 USER DIRECTION OF FEED AM03073v1 Table 14. Carrier tape dimensions for SO8 (150 mils body width) package Package W D SO8 12.00 ±0.30 1.50 +0.10/ –0.00 24/28 E P0 P2 F 1.75 4.00 2.00 5.50 ±0.10 ±0.10 ±0.10 ±0.05 A0 B0 K0 P1 T 6.50 ±0.10 5.30 ±0.10 2.20 ±0.10 8.00 ±0.10 0.30 ±0.05 DocID10772 Rev 6 Unit Bulk Qty mm 2500 M41T00S Package mechanical information Figure 17. Reel schematic T 40mm min. Access hole At slot location B D C N A G measured Tape slot In core for Full radius Tape start 2.5mm min.width At hub AM04928v1 Table 15. Reel dimensions for 12 mm carrier tape - SO8 package (150 mils body width) A B (max) (min) 330 mm (13-inch) 1.5 mm Note: C 13 mm ± 0.2 mm D N (min) (min) 20.2 mm 60 mm G 12.4 mm + 2/–0 mm T (max) 18.4 mm The dimensions given in Table 15 incorporate tolerances that cover all variations on critical parameters. DocID10772 Rev 6 25/28 Part numbering 7 M41T00S Part numbering Table 16. Ordering information scheme Example: M41T 00S M 6 F Device type M41T Supply voltage and write protect voltage 00S = VCC = 2.7 to 5.5 V Package M = SO8 Temperature range 6 = –40 °C to 85 °C Shipping method E = ECOPACK® package, tubes(1) F = ECOPACK® package, tape & reel 1. Not recommended for new design. Contact local ST sales office for availability. For other options, or for more information on any aspect of this device, please contact the ST sales office nearest you. 26/28 DocID10772 Rev 6 M41T00S 8 Revision history Revision history Table 17. Document revision history Date Revision Changes 10-Feb- 2004 0.1 First draft 20-Feb-2004 0.2 Update characteristics (Table 9, 10, 5, 7, 15) 14-Apr-2004 1.0 Product promoted; reformatted; update characteristics, including Lead-free package information (Figure 4, 10; Table 4, 11, 15) 05-May-2004 1.1 Update DC characteristics (Table 7) 16-Jun-2004 1.2 Added package shipping (Table 15) 13-Sep-2004 2.0 Update maximum ratings (Table 4) 26-Nov-2004 3.0 Promote document; update characteristics; remove references to SOX18 package (cover page, Figure 4; Table 16) 14-May-2008 4 Reformatted document; updated Section 6, Figure 1, 15, Table 1, 4, 12, 15 17-Oct-2011 5 Updated title, Features, ECOPACK® text in Section 6: Package mechanical information; added Figure 16, 17, Table 13, 14; added footnote 1 to Table 15: Ordering information scheme; minor textual updates 06-Oct-2021 6 Updated Section 2 Added note in Section 3.2 and new Table 3 DocID10772 Rev 6 27/28 M41T00S IMPORTANT NOTICE – PLEASE READ CAREFULLY STMicroelectronics NV and its subsidiaries (“ST”) reserve the right to make changes, corrections, enhancements, modifications, and improvements to ST products and/or to this document at any time without notice. Purchasers should obtain the latest relevant information on ST products before placing orders. ST products are sold pursuant to ST’s terms and conditions of sale in place at the time of order acknowledgement. Purchasers are solely responsible for the choice, selection, and use of ST products and ST assumes no liability for application assistance or the design of Purchasers’ products. No license, express or implied, to any intellectual property right is granted by ST herein. Resale of ST products with provisions different from the information set forth herein shall void any warranty granted by ST for such product. ST and the ST logo are trademarks of ST. For additional information about ST trademarks, please refer to www.st.com/trademarks. All other product or service names are the property of their respective owners. Information in this document supersedes and replaces information previously supplied in any prior versions of this document. © 2021 STMicroelectronics – All rights reserved 28/28 DocID10772 Rev 6
M41T00SM6E 价格&库存

很抱歉,暂时无法提供与“M41T00SM6E”相匹配的价格&库存,您可以联系我们找货

免费人工找货