0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
B32305B6772A200

B32305B6772A200

  • 厂商:

    TDK(东电化)

  • 封装:

    Radial

  • 描述:

    薄膜电容 径向

  • 数据手册
  • 价格&库存
B32305B6772A200 数据手册
Film Capacitors – Power Factor Correction DeltaCap MKD HD capacitor Series/Type: Ordering code: B32305-B6772-A200 B32305B Date: Version: 2012-01-06 4 Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the table and then change the color to "white". This ensures that the table disappears (invisible) for the customer PDF. Don't change formatting when entering or pasting text in the table and don't add any cell or line in and to it! Identification/Classification 1 (header 1 + top left bar): Film Capacitors – Power Factor Correction Identification/Classification 2 (header 2 + bottom left header bar): DeltaCap MKD HD capacitor Ordering code: (top right header bar) B32305B6772A200 Series/Type: (top right header bar) B32305B Preliminary data (optional): (if necessary) Department: NG FK PC PM PFC Date: 2012-01-06 Version: 4  EPCOS AG 2012. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. Film Capacitors – Power Factor Correction DeltaCap MKD HD capacitor B32305B6772A200 B32305B Construction      Dielectric: Polypropylene film Resin filling: Non-PCB, biodegradable soft resin Stacked winding Extruded round aluminium can with stud B32305 provided with integrated discharge resistors Features  Three-phase  Provided with discharge resistors  Double safety system: overpressure disconnector, self healing technology  Naturally air cooled (or forced air cooling)  Indoor mounting Typical applications  For Power Factor Correction Terminals  Screw terminals Mounting  Threaded stud at bottom of can (max. torque for M12 = 10 Nm) NG FK PC PM PFC Please read Cautions and warnings and Important notes at the end of this document. 2012-01-06 Page 2 of 9 Film Capacitors – Power Factor Correction DeltaCap MKD HD capacitor B32305B6772A200 B32305B Technical data and specifications Characteristics Rated capacitance CR 3x200uF Tolerance -5% / +5% Connection D (Delta) Rated voltage VR (RMS) 470V Rated voltage VN 640V Rated frequency fR 50Hz Output 77.2Kvar Rated current IR 69.6A Maximum ratings Vmax 517V up to 8 h daily 541V up to 30 min daily 564V up to 5 min daily 611V up to 1min daily 960V up tp 100 ms daily Imax 80A IS Up to 200 • IR (A) Power dissipation (without discharge resistors) ≤ 0.2 W/kvar (dielectric) and ≤ 0.45 W / kvar (total) Rth 2.34°C/W Test data VTT 970V AC/2s VTC 3600V AC/2s *tan δ (50 Hz) ≤2 x 10 -4 * Without discharge resistor Climatic category –40/D Tmin –40 ºC Tmax +55 ºC Tmax Hotspot +85 °C Storage temperature -40°C … +85°C Humidity Av. rel. < 95% Maximum altitude 4000 m Mean life expectancy tLD Up to 100 000 hours at temperature class -40/D NG FK PC PM PFC Please read Cautions and warnings and Important notes at the end of this document. 2012-01-06 Page 3 of 9 Film Capacitors – Power Factor Correction DeltaCap MKD HD capacitor B32305B6772A200 B32305B Up to 135 000 hours at temperature class -40/C Max. 5000 switchings per year acc. to IEC 60831 Design data Dimensions (d × h) 136x230mm Weight approx 3.6kg Impregnation Non PCB, resin filling: soft polyurethane resin Fixing Threaded bolt M12 Max. torque (Al can stud) 10 Nm Mounting position Any mounting position possible. See “Maintenance and Installation Manual” for further details. Terminals Protection degree IP20 Max. torque 1.5 Nm Terminal cross section 25 mm2 Maximum terminal current 80 A (screw terminals) Creepage distance (min) 12.7 mm Clearance (min) 9.6 mm Safety Mechanical safety Overpressure disconnector Max. short circuit current (AFC: 10 kA according UL 810 standard) Discharge resistor time ≤ 60 s to 75 V or less Reference standards IEC 60831–1/2, UL 810-5th edition Label design NG FK PC PM PFC Please read Cautions and warnings and Important notes at the end of this document. 2012-01-06 Page 4 of 9 Film Capacitors – Power Factor Correction DeltaCap MKD HD capacitor B32305B6772A200 B32305B Dimensional drawings Series B32305 Specification table Type 50 Hz Output kvar 60 Hz IR A Output kvar IR A CR d×h Weight µF mm kg 136x230 3.6 Rated voltage 640 V AC, 50/60 Hz, delta connection MKD640-D-77.2 77.2 69.6 92.7 83.5 3x200 NG FK PC PM PFC Please read Cautions and warnings and Important notes at the end of this document. Ordering code Packing unit pcs B32305-B6772-A200 4 2012-01-06 Page 5 of 9 Film Capacitors – Power Factor Correction DeltaCap MKD HD capacitor B32305B6772A200 B32305B Cautions and warnings  In case of dents of more than 1 mm depth or any other mechanical damage, capacitors must not be used at all.  This applies also in cases of oil leakages.  To ensure the full functionality of the overpressure disconnector, elastic elements must not be hindered and a minimum space of 12 mm has to be kept above each capacitor.  Do not handle the capacitor before it is discharged.  Resonance cases must be avoided by appropriate application design in any case.  Handle capacitors carefully, because they may still be charged even after disconnection due to faulty discharging devices.  Protect the capacitor properly against over current and short circuit.  Failure to follow cautions may result, worst case, in premature failures, bursting and fire. Discharging Capacitors must be discharged to a maximum of 10% of rated voltage before they are switched in again. This prevents an electric impulse discharge in the application, influences the capacitor’s service life and protects against electric shock. The capacitor must be discharged to 75 V or less within 3 minutes. There must be not any switch, fuse or any other disconnecting device in the circuit between the power capacitor and the discharging device. DeltaCap capacitors are delivered with discharge resistor included; alternatively discharge reactors are available from EPCOS. Discharge and short circuit capacitor before handling! Service life expectancy Electrical components do not have an unlimited service life expectancy; this applies to self-healing capacitors too. The maximum service life expectancy may vary depending on the application the capacitor is used in. Safety Electrical or mechanical misapplication of capacitors may be hazardous. Personal injury or property damage may result from bursting of the capacitor or from expulsion of oil or melted material due to mechanical disruption of the capacitor.  Ensure good, effective grounding for capacitor enclosures.  Provide means of disconnecting and insulating a faulty component/bank.  The terminals of capacitors, connected bus bars and cables as well as other devices may also be energized.  Follow good engineering practice. Thermal load/over-temperature After installation of the capacitor it is necessary to verify that maximum hot-spot temperature is not exceeded at extreme service conditions. NG FK PC PM PFC Please read Cautions and warnings and Important notes at the end of this document. 2012-01-06 Page 6 of 9 Film Capacitors – Power Factor Correction DeltaCap MKD HD capacitor B32305B6772A200 B32305B Overpressure disconnector To ensure full functionality of an overpressure disconnector, the following must be observed: 1. The elastic elements must not be hindered, i.e.  Connecting lines must be flexible leads (cables).  There must be sufficient space (min. 12 mm) for expansion above the connections. This will enable a longitudinal extension of the can to secure the overpressure disconnector work.  Folding beads must not be retained by clamps. 2. The maximum allowed fault current of 10000 A in accordance with UL 810 standard must be assured by the application. 3. Stress parameters of the capacitor must be within the IEC60831 specification. Overcurrent and short circuit protection  Use HRC fuses or MCCBs for short circuit protection. Short circuit protection and connecting cables should be selected so that 1.5 times the rated capacitor current can be permanently handled.  HRC fuses do not protect a capacitor against overload – they are only for short circuit protection.  The HRC fuse rating should be 1.6 to 1.8 times rated capacitor current.  Do not use HRC fuses to switch capacitors (risk of arcing).  Use thermal magnetic over current relays for overload protection. Resonance cases Resonance cases must be avoided by appropriate application design in any case. Maximum total RMS capacitor current (incl. fundamental harmonic current) specified in technical data must not be exceeded. Re-switching vs. phase-opposition In case of voltage interruption, a sufficient discharge time has to be ensured to avoid phaseopposition and resulting high inrush currents. Vibration resistance The resistance to vibration of capacitors corresponds to IEC 68, part 2–6. Max. test conditions: Test duration 6 h* Frequency range 1 10 ... 55 Hz* Displacement amplitude 0.75 mm* *corresponding to max. 98.1 m/s or 10 g NG FK PC PM PFC Please read Cautions and warnings and Important notes at the end of this document. 2012-01-06 Page 7 of 9 Film Capacitors – Power Factor Correction DeltaCap MKD HD capacitor B32305B6772A200 B32305B These figures apply to the capacitor alone. Because the fixing and the terminals may influence the vibration properties, it is necessary to check stability when a capacitor is built in and exposed to vibration. Irrespective of this, you are advised not to locate capacitors where vibration amplitude reaches the maximum in strongly vibrating equipment. Mechanical protection The capacitor has to be installed in a way that mechanical damages and dents in the aluminum can are avoided. Grounding The threaded bottom stud of the capacitor has to be used for grounding. In case grounding is done via metal chassis that the capacitor is mounted to, the layer of varnish beneath the washer and nut should be removed. The maximum tightening torque is 10 Nm. Maintenance  Check tightness of the connections/terminals periodically.  Take current reading twice a year and compare with nominal current. Use a harmonic analyser or true effective RMS-meter.  In case of current above the nominal current check your application for modifications.  If a significant increase in the amount of non-linear loads has been detected, then a consultant has to be called in for a harmonic study.  In case of the presence of harmonics installation of a de-tuned capacitor bank (reactors) must be considered.  Check the discharge resistors/reactors and in case of doubt, check their function: (1) Power the capacitor up and down. (2) After ≤ 60 seconds the voltage between the terminals must decline to less than 75 V.  Check the temperature of capacitors directly after operation for a longer period, but make sure that the capacitors have been switched off. In case of excessive temperature of individual capacitors, it is recommended to replace these capacitors, as this should be an indication for loss factor increase, which is a sign for reaching end of life. Storage and operating conditions Do not use or store capacitors in corrosive atmosphere, especially where chloride gas, sulfide gas, acid, alkali, salt or the like are present. In dusty environments regular maintenance and cleaning especially of the terminals is required to avoid conductive path between phases and/or phases and ground. Note For detailed information about PFC capacitors and cautions, refer to the latest version of EPCOS PFC Product Profile. NG FK PC PM PFC Please read Cautions and warnings and Important notes at the end of this document. 2012-01-06 Page 8 of 9 Important notes The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of an electronic component could endanger human life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of an electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as hazardous). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. The aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products. 6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the “General Terms of Delivery for Products and Services in the Electrical Industry” published by the German Electrical and Electronics Industry Association (ZVEI). 7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSMP, CSSP, CTVS, DeltaCap, DigiSiMic, DSSP, MiniBlue, MiniCell, MKD, MKK, MLSC, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SiMic, SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks. Page 9 of 9
B32305B6772A200 价格&库存

很抱歉,暂时无法提供与“B32305B6772A200”相匹配的价格&库存,您可以联系我们找货

免费人工找货