0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
S24A12-22

S24A12-22

  • 厂商:

    TELEDYNE

  • 封装:

  • 描述:

    S24A12-22 - Single Output to 125A 660 Vac AC/DC Control - Teledyne Technologies Incorporated

  • 数据手册
  • 价格&库存
S24A12-22 数据手册
Series S Single Output to 125A 660 Vac AC/DC Control Part Numbers Package & Line Chip Type Voltage1 S 24 Switch Type2 R D A R D A Output Feature3 Current 12 -22 25 40 25 -22 50 75 95 125 50 75 95 125 S 48 S 60 D Part Number Example: S48A25-22 NOTES 1) Line Voltage (nominal): 24 = 240 Vac; 48 = 480 Vac; 60 = 600 Vac 2) Switch Type: R = Random turn-on; D = Zero-cross turn-on; A = AC control, Zero-cross turn-on 3) Feature: -22 = 24 Vac control. Available on A type 240 Vac, 25 and 40A models and A type 480 Vac, 25, 50, 125A models FEATURES/BENEFITS • Industry standard package • Internal snubber (except S60 models) • Designed for all types of loads • AC or DC control available • Excellent thermal performance • Tight zero-cross window for low EMI • High immunity to surges DESCRIPTION The Series S single-phase relays are designed for all types of loads. The design incorporates an SCR or triac output. The relays utilize optical isolation to protect the control from load transients. All contain an internal snubber for output protection. High-current models are excellent for motor and phase angle control. APPLICATIONS • Heating control • Motor control • Uninterruptible power supplies • Light dimmers • Industrial and process control • On/Off controls of AC equipment APPROVALS S24 and S48 models are UL recognized. UL File Number: E128555. MECHANICAL SPECIFICATION 1.06 (27) (±.02) (±0.5) .9 (22.8) .77 (19.6) Ø.19 (Ø4.7) 1.1 (28) M4 2.29 (58.2) 1.7 (43.2) .26 (7.5) 4- 3+ .2 (5.1) M3 1.02 (25.8) 1 (25.4) 1.75 (44.5) 1.87 (47.6) 1~ 2~ TOLERANCES: ±.01 (0.3) WEIGHT: 3.18 oz. (90g) TYPICAL APPLICATION Line Voltage Figure 1 — S relays, 12–95 A; dimensions in inches (mm) 125A model uses larger M5 output screw terminals Line Protection Control 4– 1 + 3+ 2 * 1-2 can be changed * SSR must be mounted on a heat sink Figure 2 — S relays © 2003 TELEDYNE RELAYS (800) 284-7007 • www.teledynerelays.com LOAD S1 S\032003\Q1 Series S INPUT (CONTROL) SPECIFICATION Input Type Control Range D S48 S60 SxxA Sxxxxx-22 R D D A A 4 4 5 7 90 17 30 30 30 30 240 80 Vdc Vdc Vdc Vdc Vac/Vdc Vac/Vdc Input Current (mA) CONTROL CHARACTERISTICS Units Vdc 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 0 Min 3 Max 30 S24 R 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 Control Voltage (V) Input Current Range S S Sxxxxx-22 R/D A A 3 3 5.6 30 8 26 mA mA mA Input Current (mA) 6 8 Figure 3b — S24D/R relays Must Turn-Off Voltage S S24 S48 Sxxxxx-22 Input Resistance (Typical) S S Sxxxxx-22 Reverse Voltage Protection S S R/D A 30 V NA R/D A 1000 30,000 3000 Ohms Ohms R/D A A 1 15 1 3 Vdc Vac Vac Vac 4 2 0 0 20 40 60 80 100 120 140 160 180 200 220 240 Control Voltage (V) Figure 3c — S24A and S48A relays 30 Input Current (mA) Ohms 25 20 15 10 5 0 CONTROL CHARACTERISTICS 28 26 24 22 20 18 16 14 12 10 8 6 4 2 0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 0 10 20 30 40 50 60 70 80 Control Voltage (V) Figure 3d — Sxxxxx-22 relays Input Current (mA) Control Voltage (V) Figure 3a — S48R, S48D and S60D relays S2 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2003 TELEDYNE RELAYS S\032003\Q1 Series S OUTPUT (LOAD) SPECIFICATION Input Type Operating Range S24 S48 S60 Peak Voltage S24 S48 S60 Load Current Range (Resistive) 12A output current 25A output current 40A output current 50A output current 75A output current 95A output current 125A output current Inductive Load Current 12A output current 25A output current 40A output current 50A output current 75A output current 95A output current 125A output current Capacitive Load Current S60D50 S60D75 S60D90 S60D125 13 24 36 48 Arms Arms Arms Arms Turn-Off Time (60 Hz) S S Maximum Surge Current Rating (Non-Repetitive) 12A output current S24, 25A output current S24R25 S48, 25A output current 40A output current 50A output current 75A output current 95A output current © 2003 TELEDYNE RELAYS OUTPUT (LOAD) SPECIFICATION (Continued) Units Vrms Vrms Vrms On-State Voltage Drop 12A output current 1.3 1.2 1.4 1.4 1.35 1.3 1.3 1.15 1.3 1.1 V V V V V V V V V V (Continued) 125A output current 2000 A Input Type Min Max Units Maximum Surge Current Rating (Non-Repetitive) Min 12 24 24 Max 280 520 660 600 1200 1600 Vpeak Vpeak Vpeak 25A output current 40A output current 50A output current 75A output current S60D75 .005 .005 .005 .005 .005 .005 .005 12 25 40 50 75 95 125 Arms Arms Arms Arms Arms Arms Arms 95A output current S60D90 125A output current S60D125 Zero-Cross Window (Typical) S S R D/A NA ±12 Vac 2.5 5 9 12 16 20 30 Arms Arms Arms Arms Arms Arms Arms Off-State Leakage Current (60Hz) S24 S48 S48 S60 D/A R A 3 3 2.5 1 mA mA mA mA Turn-On Time (60 Hz) S S S R D A 0.1 8.3 24.9 ms ms ms R/D A 8.3 24.9 ms ms 120 240 250 230 350 550 1000 1500 A A A A A A A A Off-State dv/dt All relays Maximum di/dt (Non-Repetitive) All relays 50 A/µs 500 V/µs (800) 284-7007 • www.teledynerelays.com S3 S\032003\Q1 Series S OUTPUT (LOAD) SPECIFICATION (Continued) Input Type Operating Frequency All relays I2t for match fusing (
S24A12-22 价格&库存

很抱歉,暂时无法提供与“S24A12-22”相匹配的价格&库存,您可以联系我们找货

免费人工找货