0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
T3PS062001P

T3PS062001P

  • 厂商:

    TELEDYNE

  • 封装:

  • 描述:

    6VDC 输出 工作台(AC 至 DC) 电源 LCD 0 ~ 200A 输出 1200W 特性 LAN,可编程,开关,USB 接口

  • 数据手册
  • 价格&库存
T3PS062001P 数据手册
T3PS40381P, T3PS60251P, T3PS062001P Data Sheet Programmable Switching DC Power Supply Power With Confidence Voltage: Up to 60 Volts Current: Up to 200 Amps Power: Up to 360 Watts Tools for Improved Debugging ● Dual measurement display. Clear visibility of your power settings ● Switched mode high efficieny Power Supply Design. Small footprint whilst maintaining high power density. ● Constant Voltage and Constant Current Operation Wider application coverage for a more complete solution. ● Remote sensing to compensate for voltage drop in load leads. Ensure that the full voltage gets to your DUT. Sense compensates for wiring losses. Supports various interfaces like USB, LAN, RS-232, RS-485 Support for the maximum control flexibility. ● ● Provides more flexible system integration 1U Height and 19” Rack Mount Size Key Specifications Model Voltage Rating Current Rating Power T3PS062001P 6V 200A 1200W T3PS40381P 40V 38A 1520W T3PS60251P 60V 25A 1500W PRODUCT OVERVIEW Teledyne Test Tools new T3PS series is a single power output DC programmable power supply, which outputs 1200W to 1520W. This rack mount power supply is suitable for electric components manufacturers to verify withstanding current tests of 100A and above. Such tests incude micro-resistor, relay, shunt resistors etc. The standard 1U form factor of the power supply not only satisfy the extensive voltage demands but also provides system integrators the flexiblity of system integration. The T3PS series allows settings for CC priority or CV priority. Under CC or CV mode, users can adjust slew rate for output voltage or current based upon test requirements. There are two kinds of slew rate settings: high speed priority and slew rate priority. High speed priority sets slew rate at the maximum speed to reach CC or CV mode. Slew rate priority allows users to set slew rate for CC or CV mode in order to control rise or fall slew rate. Slew rate priority mode is ideal for motor tests because it can protect DUT from being damaged by inrush current occurred at turn-on. Comparing with other 1U power supplies available in the market, T3PS series supports a most complete array of interfaces, including USB, LAN, RS-232, RS-485, analog control interface, isolated analog interface (voltage control), and isolated analog interface (current control). Via the multi-drop mode, T3PS series will not need any switch/hub for remote control and slave unit augmentation when using LAN or USB. This feature can help users save costs on equipment. The T3PS series is ideal for the primary input of DC/DC converter and servo motor production application. T3PS series is often integrated into component test systems such as aging test equipment for capacitors, aging test equipment for diode, semiconductor production equipment, automotive electronics, and ECU for V8 engine or V12 engine, etc. The T3PS series provides users with flexible settings of High/Low Level or Trigger input/Trigger output with pulse width of 1 ~ 60ms. Trigger input controls T3PS series to output or upload preset voltage, current and memory parameters. While outputting or uploading preset voltage, current and memory parameters, T3PS series can produce corresponding Trigger output signals. PANEL INTRODUCTION 1 2 3 4 11 5 12 10 6 7 8 1. AC Power Switch (AC Power On/Off) 2. USB A Port 3. Voltage Knob 4. Display Area 5. Current Knob 6. Remote Sense 7. Analog Control Interface 8. RS 485/RS 232 9. LAN Port 10. USB Port 9 11. DC Output Terminal 12. AC Input Features • C.V/C.C Priority Mode • Adjustable Voltage/Current Rise and Fall Time • Three sets of Preset Function • Bleeder Control Function • Internal Resistance Function • Panel Lock Function • Protection: OVP, OCP, OHP, UVL, AC Fail, FAN Fail • Standard: USB, LAN, RS-232, RS-485, Analog Control Applications • The primary input of DC/DC converter • Servomotor Manufacturing Equipment • Aging test equipment for Capacitor • Aging test equipment for Diodes • Power supply for communications Equipment • Automotive 12/48V Systems • Military and Avation SPECIFICATIONS MODEL T3PS06001P T3PS40381P T3PS60251P RatedOutput Voltage(*1) 6V 40V 60V RatedOutput Current (*2) 200A 38A 25A Rated Output Power 1200W 1520W 1500W CVp-p(10 ~ 20MHz) p-p (*6) 60mV 60mV 60mV CVrms(5Hz~ 1MHz) r.m.s(*7) 8mV 8mV 8mV CCrms(5Hz~ 1MHz) r.m.s(*12) 400mV 95mV 75mV Voltage(*4) 2.6mV 6mV 8mV Current(*11) 45mA 12.6mA 10mA Voltage(*3) 2.6mV 6mV 8mV Current(*3) 22mA 5.8mA 4.5mA OUTPUT RATINGS RIPPLE AND NOISE(*5) LOAD REGULATION LINE REGULATION ANALOGPROGRAMMING AND MONITORING External Voltage Control Output Voltage Accuracyand linearity:±0.5% of rated output voltage External Voltage Control Output Current Accuracyand linearity:±1% of rated output current External Resistor Control Output Voltage Accuracyand linearity:±1% of rated output voltage External Resistor Control Output Current Accuracyand linearity:±1.5% of rated output current Output VoltageMonitor Accuracy: ±1% Output CurrentMonitor Accuracy: ±1% Shutdown Control Turns the output off with a LOW(0V to 0.5V) or short-circuit Possible logic selections: Turn the output on using a LOW (0V to 0.5V) or short-circuit, turn the output off using a HIGH (4.5V to 5V) or open-circuit; Turn the output on using a HIGH (4.5V to 5V) or open-circuit, turn the output off using a LOW (0V to 0.5V) or short-circuit Clearalarms with a LOW(0V to 0.5V) or short-circuit Output On/Off Control Alarm Clear Control CV/CC/ALM/PWRON/OUT ON Indicator Trigger Out Trigger In FRONT PANEL Display, 4 digits, Indications Buttons Photocoupler open collector output; Maximum voltage 30V,maximum sink current 8mA Maximum low level output = 0.8V Minimum high level output = 2V Maximum source current = 8mA Maximum low level input voltage = 0.8V Minimum high level input votage= 2V Maximum sink current = 8mA Voltage Accuracy 0.1%+ Current Accuracy 0.2%+ 12mV GREENLED's: CV, CC,V, A, VSR,ISR, DLY, RMT, LAN, M1, M2, M3, RUN, Output ON; REDLED's: ALM, ERR Lock/Local(Unlock), PROT(ALM_CLR),Function(M1), Test(M2), Set(M3), Shift, Output Knobs Voltage, Current USBPort Type A USB connector TRANSIENT RESPONSETIME (*10) Transient ResponseTime 1.5mv 1ms 1ms OUTPUT RESPONSETIME RiseTime(*8) FallTime(*9) Rated load 80ms 80ms 80ms No Load 80ms 80ms 80ms Rated load 10ms 80ms 80ms No Load 500ms 1100ms 1100ms TEMPERATURECOEFFICIENCE Voltage & Current 100ppm/°C after a 30 minute warm-up REMOTE SENSECOMPENSATION VOLTAGE(SINGLE WIRE) Voltage 1V 2V 3V SPECIFICATIONS MODEL T3PS06001P T3PS40381P T3PS60251P PROGRAMMING AND MEASUREMENTS(RS-232/485, USB, LAN) Output Voltage ProgrammingAccuracy 0.05%+ 3mV 20mV 30mV Output Current Programming Accuracy 0.2%+ 200mA 38mA 25mA Output Voltage ProgrammingResolution 0.2mV 1.3mV 2mV Output Current ProgrammingResolution 6mA 1.2mA 0.8mA Output Voltage Measurement Accuracy 0.1%+ 6mV 40mV 60mV Output Current Measurement Accuracy 0.2%+ 400mA 76mA 50mA Output VoltageMeasurement Resolution 0.2mV 1.3mV 2mV Output Current MeasurementResolution 6mA 1.2mA 0.8mA PROTECTIONFUNCTION Over Voltage Protection(OVP) Setting Range 0.6~6.6V 4~44V 5~66V Setting Accuracy 60mV 400mV 600mV Over Current Protection(OCP) Setting Range 5~220A 3.8~41.8A 2.5~27.5A Setting Accuracy 4000mA 760mA 500mA Under Voltage Limit(UVL) Setting Range 0~6.3V 0~42V 0~63V Over TemperatureProtection(OHP) operation Turn the output off. Incorrect SensingConnectionProtection(SENSE) operation Turn the output off. Low ACInput Protection (AC-FAIL) operation Turn the output off. Shutdown (SD) operation Turn the output off. PowerLimit (POWER LIMIT) operation Over power limit Value (Fixed) Approx. 105%of rated output power INTERFACE CAPABILITIES USB TypeA:Host, TypeB:Slave, Speed: 1.1/2.0, USB Class: CDC(Communications Device Class) LAN MAC Address, DNS IP Address, User Password, GatewayIP Address, InstrumentIP Address, Subnet Mask Complies with the EIA232D/ EIA485 Specifications RS=232/RS-485 ENVIRONMENTALCONDITIONS Operating Temperature 0°C ~ 50°C(*14) Storage Temperature -25°C ~ 70°C Operating Humidity 20% ~ 85% RH; No condensation StorageHumidity 90% RH or less; No condensation Altitude Maximum 2000m INPUT CHARACTERISTICS Nominal Input Rating 100Vacto 240Vac,50Hz to 60Hz, single phase Input Voltage Range 85Vac ~ 265Vac Input FrequencyRange 47Hz ~ 63Hz Maximum Input Current 100Vac/200Vac(A) 21/11 Inrush Current Less than 50A Maximum Input Power 2000VA Power Factor 100Vac/200Vac 0.99/0.98 Hold-up Time 20ms or greater Efficiency(*13) 100Vac/200Vac(%) 77/79 84/87 84/87 DIMENSIONS & WEIGHT 423(W) × 43.6(H) × 447.2(D)mm, Approx. 8.7kg Note: *1. Minimum voltage is guaranteed to maximum 0.2% of the rated output voltage. *8. From 10%~90% of rated output voltage, with rated resistive load. *2. Minimum current is guaranteed to maximum 0.4% of the rated output current. *9. From 90%~10% of rated output voltage, with rated resistive load. *3. At 85~132Vac or 170~265Vac, constant load. *10. Time for output voltage to recover within 0.5% of its rated output for a load change from 10~90% of its rated output current. Voltage set point from 10%~100% of rated output. *4. From No-load to Full-load, constant input voltage. Measured at the sensing point in Remote Sense. *11. For load voltage change, equal to the unit voltage rating, constant input voltage. *5. Measure with JEITA RC-9131B (1:1) probe. *12. For 6V model the ripple is measured at 2~6V output voltage and full output current. For other models, the ripple is measured at 10~100% output voltage and full output current. *6. Measurement frequency bandwidth is 10Hz~20MHz. *13. At rated output power. *7. Measurement frequency bandwidth is 5Hz~1MHz. *14 If the front panel filter kit is installld, the temperature is guaranteed to 40°C. ORDERING INFORMATION ORDERING INFORMATION T3PS062001P 1200W Programmable Switching DC Power Supply T3PS40381P 1520W Programmable Switching DC Power Supply T3PS60251P 1500W Programmable Switching DC Power Supply STANDARD ACCESSORIES Qty. Output terminal cover 1 Analog connector plug kit 1 Output terminal M8 bolt set (6V~60V model) 1 Input terminal cover 1 1U Handle(RoHS) 2 1U Bracket(LEFT, RoHS) 1 1U Bracket (RIGHT,RoHS) 1 ABOUT TELEDYNE TEST TOOLS Company Profile Teledyne LeCroy is a leading provider of oscilloscopes, protocol analyzers and related test and measurement solutions that enable companies across a wide range of industries to design and test electronic devices of all types. Since our founding in 1964, we have focused on creating products that improve productivity by helping engineers resolve design issues faster and more effectively. Oscilloscopes are tools used by designers and engineers to measure and analyze complex electronic signals in order to develop high-performance systems and to validate electronic designs in order to improve time to market. The Teledyne Test Tools brand extends the Teledyne LeCroy product portfolio with a comprehensive range of test equipment solutions. This new range of products delivers a broad range of quality test solutions that enable engineers to rapidly validate product and design and reduce time-tomarket. Designers, engineers and educators rely on Teledyne Test Tools solutions to meet their most challenging needs for testing, education and electronics validation. Location and Facilities Headquartered in Chestnut Ridge, New York, Teledyne Test Tools and Teledyne LeCroy has sales, service and development subsidiaries in the US and throughout Europe and Asia. Teledyne Test Tools and Teledyne LeCroy products are employed across a wide variety of industries, including semiconductor, computer, consumer electronics, education, military/aerospace, automotive/industrial, and telecommunications. Teledyne LeCroy (US Headquarters) 700 Chestnut Ridge Road Chestnut Ridge, NY. USA 10977-6499 Phone: 800-553-2769 or 845-425-2000 Fax Sales: 845-578-5985 Phone Support: 1-800-553-2769 Email Sales: contact.corp@teledynelecroy.com Email Support: support@teledynelecroy.com Web Site: http://teledynelecroy.com/ Teledyne LeCroy (European Headquarters) Teledyne LeCroy GmbH Im Breitspiel 11c D-69126 Heidelberg, Germany Distributed by: Phone: Fax: Phone Service: Phone Support: Email Sales: Email Service: Email Support: Web Site: +49 6221 82700 +49 6221 834655 +49 6221 8270 85 +49 6221 8270 28 contact.gmbh@teledynelecroy.com service.gmbh@teledynelecroy.com tlc.t3.appsupport.eu@teledyne.com http://teledynelecroy.com/germany teledynelecroy.com © 2018 Teledyne Test Tools is a brand and trademark of Teledyne LeCroy Inc. All rights reserved. Specifications,prices,availability and delivery subject to change without notice. Product brand or brand names are trademarks or requested trademarks of their respective holders. T3 stands for Teledyne Test Tools. 21Sep2021
T3PS062001P 价格&库存

很抱歉,暂时无法提供与“T3PS062001P”相匹配的价格&库存,您可以联系我们找货

免费人工找货