0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
AC01000001800JA100

AC01000001800JA100

  • 厂商:

    TFUNK(威世)

  • 封装:

    -

  • 描述:

    插件电阻 - 180Ω ±5% 1W +100~+180ppm/℃

  • 数据手册
  • 价格&库存
AC01000001800JA100 数据手册
AC, AC-AT www.vishay.com Vishay Draloric Cemented Leaded Wirewound Resistors FEATURES • AEC-Q200 qualified AC-AT series • High power dissipation in small design • Non-flammable UL 94 V-0 coating conforming to • Excellent pulse load capability • Non-inductive (NI) version available • WSZ-form lead bending available for SMD mounting • Material categorization: for definitions of compliance please see www.vishay.com/doc?99912 LINKS TO ADDITIONAL RESOURCES 3D 3D APPLICATIONS 3D Models The AC series is the perfect choice for general purpose power applications. The AEC-Q200 qualified AC-AT series is best suited for automotive applications. The robust silicone cement coating can handle challenging ambient and operating conditions. Typical applications include but are not limited to energy meters, power supplies and automotive electronics. For a given application, requirements of ohmic value, rated power, peak voltage, pulse shape, pulse duration, lead bending, and environmental conditions may be submitted to recommend the most suitable product. Various lead forms are available such as RT (radial taped), WSZ (Z-form), DK (double kink), EK (single kink) with defined mounting pitch. • Automotive electronics • Industrial electronics • Power supplies • White goods • Pre-charging / discharging applications STANDARD ELECTRICAL SPECIFICATIONS TYPE RATED RATED DISSIPATION DISSIPATION P40 P70 LIMITING VOLTAGE Umax. RESISTANCE RANGE (1) TCR = -10 ppm/K to -80 ppm/K RESISTANCE RANGE (1) TCR = +100 ppm/K to +180 ppm/K RESISTANCE RANGE (1) TCR = ± 100 ppm/K 0.10 Ω to 33 Ω 36 Ω to 2.4 kΩ - ±5% - ±5% RESISTANCE TOLERANCE AC01 1W 0.9 W P x R AC01-AT 1W 0.9 W P x R 0.39 Ω to 33 Ω 36 Ω to 2.4 kΩ AC03 3W 2.5 W P x R 0.10 Ω to 390 Ω 430 Ω to 3.3 kΩ 3.6 kΩ to 5.1 kΩ ±5% AC03-AT 3W 2.5 W P x R 0.27 Ω to 390 Ω 430 Ω to 3.3 kΩ - ±5% AC04 4W 3.5 W P x R 0.10 Ω to 620 Ω 680 Ω to 6.8 kΩ - ±5% AC04-AT 4W 3.5 W P x R 0.22 Ω to 620 Ω 680 Ω to 6.8 kΩ - ±5% AC05 5W 4.7 W P x R 0.10 Ω to 910 Ω 1.0 kΩ to 10 kΩ - ±5% AC05-AT 5W 4.7 W P x R 0.62 Ω to 910 Ω 1.0 kΩ to 10 kΩ - ±5% AC07 7W 5.8 W P x R 0.10 Ω to 820 Ω 910 Ω to 15 kΩ - ±5% AC07-AT 7W 5.8 W P x R 1.0 Ω to 820 Ω 910 Ω to 15 kΩ - ±5% AC10 10 W 8.4 W P x R 0.22 Ω to 560 Ω 620 Ω to 27 kΩ - ±5% AC10-AT 10 W 8.4 W P x R 2.0 Ω to 560 Ω 620 Ω to 27 kΩ - ±5% Notes • The operating temperature range for these resistors is from -55 °C up to 250 °C (1) Resistance value to be selected from E24 series Revision: 07-Dec-2020 Document Number: 28730 1 For technical questions, contact: ww1resistors@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 AC, AC-AT www.vishay.com Vishay Draloric PART NUMBER AND PRODUCT DESCRIPTION Part Number: AC03000001509JAC00 AC03AT0001509JAC00 A C 0 3 0 0 0 0 0 1 5 0 9 J A C 0 0 A C 0 3 A T 0 0 0 1 5 0 9 J A C 0 0 TCR / MATERIAL VARIANT (1) MODEL AC01000 = AC01 AC03000 = AC03 AC04000 = AC04 AC05000 = AC05 AC07000 = AC07 AC10000 = AC10 AC01AT0 = AC01-AT AC03AT0 = AC03-AT AC04AT0 = AC04-AT AC05AT0 = AC05-AT AC07AT0 = AC07-AT AC10AT0 = AC10-AT 0 = neutral 1 = RT 2 = SWI 3 = DK SP 20 mm 4 = DK LP 33 mm 5 = DK LP 17.8 mm 6 = NI Non inductive 7 = DK LP 25.4 mm 8 = DK SP 25.4 mm 9 = AC03/AC03AT-WSZ A = EK 22.5 mm B = EK 17.8 mm C = EK 25.4 mm D = Cu wire 0.8 mm E = EK 33 mm G = DK SP 33 mm H = EK 20 mm I = DK SP 17.8 mm K = AC05/AC05AT-WSZ 0 = standard VALUE 3 digit value 1 digit multiplier MULTIPLIER 7 = *10-3 8 = *10-2 9 = *10-1 0 = *100 1 = *101 2 = *102 TOLERANCE CODE PACKAGING CODE J = ± 5.0 % (see Packaging table) SPECIAL 00 = standard 2 digit code = customized version (2) Product Description: AC03 15R 5 % AC AC03AT 15R 5 % AC AC03 15R 5% AC AC03-AT 15R 5% AC TYPE RESISTANCE TOLERANCE PACKAGING R10 = 0.1 Ω 75R = 75 Ω 27K = 27 kΩ 5% AC01 AC03 AC04 AC05 AC07 AC10 AC01-AT AC03-AT AC04-AT AC05-AT AC07-AT AC10-AT AC A1 AB AE LB LC LK BM Notes • AC-AT: it is currently available only for standard axial taped parts and for AC03AT-WSZ, AC05AT-WSZ. Contact us for the availability of AC-AT in other lead termination bending forms (1) RT = radial taped lead bending (refer page 11) SWI = special winding EK = single kink lead bending (refer page 10) DK LP = double kink large pitch lead bending (refer page 10) DK SP = double kink small pitch lead bending (refer page 10) WSZ = “Z” form leads (refer page 11) (2) For special windings or the non-inductive versions, please contact: ww1resistors@vishay.com Revision: 07-Dec-2020 Document Number: 28730 2 For technical questions, contact: ww1resistors@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 AC, AC-AT www.vishay.com Vishay Draloric PACKAGING TYPE / SIZE CODE DESCRIPTION QUANTITY PACKAGING STYLE WIDTH PITCH DIMENSIONS AC01 AC01-AT A1 A1 1000 Taped acc. to IEC 60286-1 fan-folded in a box 63 mm 10 mm 260 mm x 85 mm x 70 mm AC01 DK/EK LC LC 500 Bulk packaging - - 260 mm x 80 mm x 55 mm AC01 RT AE AE 2500 Taped acc. to IEC 60286-2 fan-folded in a box - 12.7 mm 200 mm x 46 mm x 334 mm AC03 AC03-AT AC AC 500 Taped acc. to IEC 60286-1 fan-folded in a box 63 mm 10 mm 260 mm x 85 mm x 58 mm AC03 DK/EK LC LC 500 Bulk packaging - - 224 mm x 82 mm x 54 mm AC03 RT AQ AQ 1800 Taped acc. to IEC 60286-2 fan-folded in a box - 12.7 mm 200 mm x 46 mm x 334 mm AC03 WSZ AC03-AT WSZ BM BM 1250 Blister taped acc. to IEC 60286-3 on reel - 8 mm 350 mm x 350 mm x 55 mm AC04 (1) AC04-AT (1) AC AC 500 Taped acc. to IEC 60286-1 fan-folded in a box 63 mm 10 mm 260 mm x 85 mm x 70 mm 260 mm x 85 mm x 58 mm AC04 DK/EK LC LC 500 Bulk packaging - - 224 mm x 82 mm x 54 mm AC05 AC05-AT AC AC 500 Taped acc. to IEC 60286-1 fan-folded in a box 63 mm 10 mm 270 mm x 86 mm x 118 mm AC05 DK/EK LC LC 500 Bulk packaging - - 224 mm x 82 mm x 54 mm AC05 WSZ AC05-AT WSZ BW BW 350 Blister taped acc. to IEC 60286-3 on reel - 16 mm 350 mm x 335 mm x 60 mm AC07 AC07-AT AC AC 500 Taped acc. to IEC 60286-1 fan-folded in a box 73 mm 10 mm 265 mm x 90 mm x 118 mm AC07 DK/EK LB LB 250 Bulk packaging - - 224 mm x 82 mm x 54 mm AC10 AC10-AT AB AB 250 Taped acc. to IEC 60286-1 fan-folded in a box 88 mm 10 mm 265 mm x 105 mm x 105 mm Note (1) Manufacturing at different production locations may involve use of differently sized box Revision: 07-Dec-2020 Document Number: 28730 3 For technical questions, contact: ww1resistors@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 AC, AC-AT www.vishay.com Vishay Draloric DESCRIPTION ASSEMBLY Wirewound resistors are best suited for use in high power, high current applications. The silicone cement lacquer coating enables AC series to withstand challenging operating and environmental conditions. The coating is resistant to cleaning solvents specified in IEC 60115-1 (1). Production is strictly controlled and follows an extensive set of instructions established for reproducibility. The resistors are axial leaded for soldering. The terminals of the resistors are completely lead (Pb)-free, the special tin plating provides compatibility with lead (Pb)-free and lead-containing soldering processes. The winding is done with a specific material on a specially developed fine ceramic body (Al2O3). The ceramic meets the highest requirements against mechanical resistance, thermal shocks, dielectric strength, and insulation resistance at high temperatures. With different diameters and turn spacings of resistive wire, a large ohmic value range can be covered. The resistors are marked with resistance, rated dissipation (P40) and tolerance. Product quality is verified by testing procedures, performed on all individual resistors. Resistance is measured on the lead wires at a distance of 6 mm from the resistor body. If a greater length of lead wire is used in the application, the user may need to consider the additional wire resistance, particularly with low resistance products. MATERIALS Vishay acknowledges the following systems for the regulation of hazardous substances: • IEC 62474, Material Declaration for Products of and for the Electrotechnical Industry, with the list of declarable substances given therein (2) • The Global Automotive Declarable Substance List (GADSL) (3) • The REACH regulation (1907/2006/EC) and the related list of substances with very high concern (SVHC) (4) for its supply chain The products do not contain any of the banned substances as per IEC 62474, GADSL, or the SVHC list, see www.vishay.com/how/leadfree. Hence the products fully comply with the following directives: • 2000/53/EC End-of-Life Vehicle Directive (ELV) and Annex II (ELV II) • 2011/65/EU Restriction of the Use of Hazardous Substances Directive (RoHS) with amendment 2015/863/EU • 2012/19/EU Waste Electrical and Electronic Equipment Directive (WEEE) Vishay pursues the elimination of conflict minerals from its supply chain, see the Conflict Minerals Policy at www.vishay.com/doc?49037 Special lead forms may be available on request, please inquire at ww1resistors@vishay.com. As these components are high power dissipation resistors, customers are advised to use a high melting point solder. APPLICATION INFORMATION The power dissipation of the resistor generates a temperature rise with respect to the ambient. The permissible dissipation is derated for temperatures above 40 °C, as shown in the derating diagram, in order to avoid overheating of the resistor. The heat dissipated from the resistor may affect adjacent components, hence proper clearance will be required in order to avoid overheating. The resistive wire is encapsulated by a protective lacquer coating. All materials used are non-flammable and inorganic. These resistors do not feature a limited lifetime when operated within the permissible limits. However, resistance value drift increasing over operating time may result in exceeding a limit acceptable to the specific application, thereby establishing a functional lifetime. APPROVALS AC-AT series is AEC-Q200 qualified, specifically for the use in automotive applications. It is currently available only for standard axial taped parts and for AC03AT-WSZ, AC05AT-WSZ. Contact us for the availability of AC-AT in other lead termination bending forms. RELATED PRODUCTS UL approved, special cement coated fusible resistor is also available. For details please see the datasheet: “AC01-CS, AC03-CS, AC05-CS - Axial Cemented Fusible Wirewound Safety Resistors” www.vishay.com/doc?28909 For high surge wirewound products, silicone cement coated Z300-Cxx series is available, see the datasheet: “Z300-Cxx - High Surge Axial Cemented Wirewound Resistors” www.vishay.com/doc?21027 For precision applications, cement coated PAC series is available, see the datasheet: “PAC Series - Cemented Wirewound Precision Resistors” www.vishay.com/doc?28731 Notes (1) Other cleaning solvents with aggressive chemicals should be evaluated in actual cleaning process for their suitability (2) The IEC 62474 list of declarable substances is maintained in a dedicated database, which is available at http://std.iec.ch/iec62474 (3) The Global Automotive Declarable Substance List (GADSL) is maintained by the American Chemistry Council and available at www.gadsl.org (4) The SVHC list is maintained by the European Chemical Agency (ECHA) and available at http://echa.europa.eu/candidate-list-table Revision: 07-Dec-2020 Document Number: 28730 4 For technical questions, contact: ww1resistors@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 AC, AC-AT www.vishay.com Vishay Draloric PULSE DIAGRAMS (ti = pulse duration; tp = repetition time) 1000 10 000 tp/ti = 1000 1R0 R10 10R 100R 2K0 tp/ti = 200 100 10 Pˆ max. (W) ˆ P max. (W) 10 000 tp/ti = 50 tp/ti = 1000 1000 R10 1R0 10R 110R 4K7 tp/ti = 200 tp/ti = 50 100 tp/ti = 10 tp/ti = 10 10 tp/ti = 2 tp/ti = 2 1 10-6 10-5 10-4 10-3 10-2 10-1 1 10-6 1 10-5 10-4 10-3 10-2 ti (s) AC03 and AC03-AT Pulse on a regular basis; max. permissible ˆ max.) as a function of pulse duration (t ) peak pulse power ( P i 10 000 tp/ti = 1000 ˆ P max. (W) Pˆ max. (W) 1000 R10 1R0 10R 100R 6K8 tp/ti = 200 tp/ti = 50 1000 100 tp/ti = 10 1 10-6 tp/ti = 2 10-5 10 10-4 10-3 10-2 10-1 tp/ti = 1000 tp/ti = 200 1R1 R10 11R 100R 8K2 tp/ti = 50 100 10 1 10-6 1 tp/ti = 10 tp/ti = 2 10-5 10-4 10-3 10-2 10-1 ti (s) 10 AC05 and AC05-AT Pulse on a regular basis; max. permissible ˆ max.) as a function of pulse duration (t ) peak pulse power ( P i 10 000 tp/ti = 1000 tp/ti = 200 Pˆ max. (W) Pˆ max. (W) 10 000 1R1 R10 11R 100R 15K 1000 tp/ti = 50 tp/ti = 1000 R68 2R2 33R 240R 15K tp/ti = 200 1000 100 tp/ti = 10 tp/ti = 50 tp/ti = 10 tp/ti = 2 tp/ti = 2 10 1 10-6 1 ti (s) AC04 and AC04-AT Pulse on a regular basis; max. permissible ˆ max.) as a function of pulse duration (t ) peak pulse power ( P i 100 1 ti (s) AC01 and AC01-AT Pulse on a regular basis; max. permissible ˆ max.) as a function of pulse duration (t ) peak pulse power ( P i 10 000 10-1 10 10-5 10-4 10-3 10-2 10-1 1 10 ti (s) AC07 and AC07-AT Pulse on a regular basis; max. permissible ˆ max.) as a function of pulse duration (t ) peak pulse power ( P i Revision: 07-Dec-2020 1 10-6 10-5 10-4 10-3 10-2 10-1 1 10 ti (s) AC10 and AC10-AT Pulse on a regular basis; max. permissible ˆ max.) as a function of pulse duration (t ) peak pulse power ( P i Document Number: 28730 5 For technical questions, contact: ww1resistors@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 AC, AC-AT www.vishay.com Vishay Draloric PULSE DIAGRAMS Pulse energy in joules or wattseconds is calculated with the help of the R-value to be used in the application. Choose the R value on X axis and look for the corresponding E (Ws/Ω) value on Y axis. Multiplying both the R (Ω) to corresponding E (Ws/Ω), will be resultant total pulse Energy (Ws or J) for adiabatic conditions. 1000 Pulse Energy (Ws/Ω) Pulse Energy (Ws/Ω) 100 10 1 0.1 0.01 100 10 1 0.1 0.01 0.001 0.001 0.0001 0.0001 0.00001 0.1 1 10 100 1000 0.1 10 000 1 10 100 1000 R (Ω) AC01 and AC01-AT Pulse capability; E (Ws) as a function of R (Ω) AC03 and AC03-AT Pulse capability; E (Ws) as a function of R (Ω) 1000 Pulse Energy (Ws/Ω) Pulse Energy (Ws/Ω) 1000 100 10 1 0.1 100 10 1 0.1 0.01 0.01 0.001 0.001 0.0001 0.0001 0.1 1 10 100 1000 10 000 0.1 1 10 100 R (Ω) AC04 and AC04-AT Pulse capability; E (Ws) as a function of R (Ω) 1000 10 000 R (Ω) AC05 and AC05-AT Pulse capability; E (Ws) as a function of R (Ω) 1000 Pulse Energy (Ws/Ω) 1000 Pulse Energy (Ws/Ω) 10 000 R (Ω) 100 10 1 0.1 100 10 1 0.1 0.01 0.01 0.001 0.001 0.0001 0.0001 0.1 1 10 100 1000 10 000 R (Ω) AC07 and AC07-AT Pulse capability; E (Ws) as a function of R (Ω) Revision: 07-Dec-2020 0.1 1 10 100 1000 10 000 100 000 R (Ω) AC10 and AC10-AT Pulse capability; E (Ws) as a function of R (Ω) Document Number: 28730 6 For technical questions, contact: ww1resistors@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 AC, AC-AT www.vishay.com Vishay Draloric 1500 Vˆ max. (V) Vˆ max. (V) 2000 1500 1000 1000 500 500 0 10-6 10-5 10-4 10-3 10-2 10-1 0 10-6 1 10-5 10-4 10-3 10-2 10-1 AC01 and AC01-AT Pulse on a regular basis; max. permissible peak pulse voltage ( Vˆ max.) as a function of pulse duration (ti) AC03 and AC03-AT Pulse on a regular basis; max. permissible peak pulse voltage ( Vˆ max.) as a function of pulse duration (ti) 2500 Vˆ max. (V) Vˆ max. (V) 2500 2000 2000 1500 1500 1000 1000 500 500 0 10-6 10-5 10-4 10-3 10-2 10-1 0 10-6 1 10-5 10-4 10-3 10-2 10-1 ti (s) AC05 and AC05-AT Pulse on a regular basis; max. permissible peak pulse voltage ( Vˆ max.) as a function of pulse duration (ti) 5000 Vˆ max. (V) 5000 Vˆ max. (V) 1 ti (s) AC04 and AC04-AT Pulse on a regular basis; max. permissible peak pulse voltage ( Vˆ max.) as a function of pulse duration (ti) 4000 4000 3000 3000 2000 2000 1000 1000 0 10-6 1 ti (s) ti (s) 10-5 10-4 10-3 10-2 10-1 1 ti (s) AC07 and AC07-AT Pulse on a regular basis; max. permissible peak pulse voltage ( Vˆ max.) as a function of pulse duration (ti) Revision: 07-Dec-2020 0 10-6 10-5 10-4 10-3 10-2 10-1 1 ti (s) AC10 and AC10-AT Pulse on a regular basis; max. permissible peak pulse voltage ( Vˆ max.) as a function of pulse duration (ti) Document Number: 28730 7 For technical questions, contact: ww1resistors@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 AC, AC-AT www.vishay.com Vishay Draloric Rated Power in % FUNCTIONAL PERFORMANCE 120 100 80 60 40 20 0 -55 0 50 40 100 Derating Temperature Rise in K 150 200 250 300 350 Ambient Temperature in °C 350 AC10, AC10-AT 300 250 AC07, AC07-AT 200 AC05, AC05-AT 150 AC04, AC04-AT 100 AC03, AC03-AT 50 AC01, AC01-AT 0 0 5 Temperature Rise Revision: 07-Dec-2020 10 15 Power in W Document Number: 28730 8 For technical questions, contact: ww1resistors@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 AC, AC-AT www.vishay.com Vishay Draloric TEST PROCEDURES AND REQUIREMENTS All tests are carried out in accordance with the following specifications: • Temperature: 15 °C to 35 °C • IEC 60115-1, generic specification (includes tests) • Relative humidity: 45 % to 75 % The test and requirements table contains only the most important tests. For the full test schedule refer to the documents above. • Air pressure: 86 kPa to 106 kPa (860 mbar to 1060 mbar) The tests are carried out in accordance with IEC 60068-2-xx test method and under standard atmospheric conditions in accordance with IEC 60068-1, 4.3. Climatic category -55 / 200 / 56 (rated temperature range: lower category temperature, upper category temperature; damp heat, steady state, test duration: 56 days) is valid. Unless otherwise specified the following values apply: For performing some of the tests, the components are mounted on a test board in accordance with IEC 60115-1, 4.31. In test procedures and requirements table, only the tests and requirements are listed with reference to the relevant clauses of IEC 60115-1 and IEC 60068-2-xx test methods. A short description of the test procedure is also given. TEST PROCEDURES AND REQUIREMENTS IEC 60068-2 TEST METHOD TEST PROCEDURE REQUIREMENTS PERMISSIBLE CHANGE (ΔRMAX.) 4.13 - Short time overload Room temperature; 10x rated power P40; 5s ± (2 % R + 0.1 Ω) 4.16 21 (Ua1) 21 (Ub) 21 (Uc) Robustness of terminations Tensile, bending and torsion No damage ± (0.5 % R + 0.05 Ω) 4.18 20 (Tb) Resistance to soldering heat Unmounted components (260 ± 5) °C; (10 ± 1) s ± (0.5 % R + 0.05 Ω) 4.19 - Rapid change of temperature 30 min at -55 °C and 30 min at +200 °C; 5 cycles ± (1.5 % R + 0.05 Ω) IEC 60115-1 CLAUSE 4.23 Climatic sequence: 4.23.2 2 (Ba) Dry heat 16 h; 200 °C 4.23.3 30 (Db) Damp heat (accelerated) 1st cycle 24 h; 55 °C; 90 % to 100 % RH 4.23.4 1 (Aa) Cold 2 h; -55 °C 4.23.5 13 (M) Low air pressure 2 h; 8.5 kPa; 15 °C to 35 °C 4.23.6 30 (Db) Damp heat remaining cyclic 5 days; 55 °C; 95 % to 100 % RH; 5 cycles 4.24 78 (Cab) Damp heat, (steady state) 56 days; (40 ± 2) °C; (93 ± 5) % RH ± (5 % R + 0.1 Ω) 4.25.2 - Endurance (at room temperature) 1000 h; loaded with 116 % of P70 1.5 h ON and 0.5 h OFF ± (5 % R + 0.1 Ω) 4.25.3 - Endurance at upper category temperature 200 °C; 30 % of P70; 1000 h ± (5 % R + 0.1 Ω) 4.35 - Flammability IEC 60695-11-5 needle flame test; 10 s No burning after 30 s 4.37 67 C(y) Damp heat, steady state, accelerated (85 ± 2) °C; RH (85 ± 3) %; 1000 h; 10 % of operation power (P70) U ≤ 0.3 x Umax. ± (5 % R + 0.1 Ω) 4.38 - Electrostatic discharge test 2 discharges, 8 kV (1 positive, 1 negative) ± (5 % R + 0.1 Ω) Revision: 07-Dec-2020 ± (1 % R + 0.05 Ω) Document Number: 28730 9 For technical questions, contact: ww1resistors@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 AC, AC-AT www.vishay.com Vishay Draloric DIMENSION AND MASS L d x B D DIMENSIONS in millimeters TYPE AC01, AC01-AT AC03, AC03-AT AC04, AC04-AT AC05, AC05-AT AC07, AC07-AT AC10, AC10-AT Lmax. 11.0 13.0 16.5 18.0 26.0 44.0 d (1) Dmax. 4.3 4.8 5.5 7.5 7.5 8.0 xmax. 2 2 3 3 3 3 0.8 ± 0.03 B 63 ± 1 63 ± 1 63 ± 1 63 ± 1 73 ± 1 88 ± 1 MASS PER UNIT (g) 0.52 0.75 1.10 1.90 2.60 4.50 LEAD TERMINATION BENDING FORMS L P1 P1 L L ØD Ød h Ød h P2 P ØB P2 ØB LEAD BENDING STYLE = EK (Single Kink) Ød h ØB LEAD BENDING STYLE = DK SP (Double Kink Small Pitch) SMAX. LEAD BENDING STYLE = DK LP (Double Kink Large Pitch) DIMENSIONS - Single and double kink lead type outline TYPE Ø Dmax. (mm) Lmax. (mm) AC01 4.3 11.0 AC03 4.8 13.0 AC04 5.5 16.5 AC05 7.5 18.0 AC07 7.5 26.0 KINK TYPE EK DK SP DK LP EK EK DK SP DK SP DK LP DK LP EK DK SP DK SP DK LP EK EK DK SP EK DK SP DK LP TERMINATION WIRE DIAMETER (1) Ø d (mm) 0.8 ± 0.03 0.8 ± 0.03 0.8 ± 0.03 0.8 ± 0.03 0.8 ± 0.03 0.8 ± 0.03 0.8 ± 0.03 0.8 ± 0.03 0.8 ± 0.03 0.8 ± 0.03 0.8 ± 0.03 0.8 ± 0.03 0.8 ± 0.03 0.8 ± 0.03 0.8 ± 0.03 0.8 ± 0.03 0.8 ± 0.03 0.8 ± 0.03 0.8 ± 0.03 h ± 1 P ± 0.5 (mm) (mm) 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 17.8 20.0 25.4 25.4 22.5 25.4 33.0 - P1 ± 0.5 (mm) 19.8 17.8 22.0 27.4 17.8 25.4 22.0 27.4 25.4 22.0 35.0 33.0 P2 ± 3 Smax. (mm) (mm) 17.8 17.8 20.0 25.4 17.8 25.4 20.0 25.4 25.4 20.0 33.0 33.0 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Ø B ± 0.1 (mm) MASS (g) 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 0.52 0.52 0.52 0.75 0.75 0.75 0.75 0.75 0.75 1.10 1.10 1.10 1.10 1.90 1.90 1.90 2.60 2.60 2.60 PART NUMBER VARIANT B I 5 H C 3 8 5 7 C 3 8 7 A C 3 E G 4 Note (1) Terminal wire material is FeCu with Sn coating Revision: 07-Dec-2020 Document Number: 28730 10 For technical questions, contact: ww1resistors@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 AC, AC-AT www.vishay.com Vishay Draloric Z-FORM LEADS FOR SMD MOUNTING in millimeters A B Recommended solder pad dimensions ØD l LEAD BENDING STYLE = WSZ (Z-form) n H a b m L F Ød Ø d (1) Ø Dmax. A B F H L a b l m AC03, AC03-AT 0.8 ± 0.03 4.8 17 ± 0.3 11 - 12 4.8 ± 0.3 3.6 ± 0.2 5.0 ± 0.5 4 8 12.2 25 2 AC05, AC05-AT 0.8 ± 0.03 7.5 23.5 ± 0.5 18 max. 7.7 ± 0.5 5.73 ± 0.5 7.9 ± 0.7 4 10 18.7 25 2 TYPE WSZ n Notes (1) Terminal wire material is FeCu with Sn coating • Given solder pad dimension is a suggestion only, used for testing purposes at practicable conditions. Customer has to reconsider temperature restrictions due to solder type, PCB-material, etc. according to individual application AC01 WITH RADIAL TAPING LEAD BENDING STYLE = RT (Radial Taped) DIMENSIONS in millimeters P H1 Pitch of components P 12.7 ± 1.0 Lead spacing F 5.0 + 0.6, - 0.1 Width of carrier tape W 18.0 ± 0.5 Height for cutting (max.) L1 11 Height for insertion (max.) H1 32 F L1 W AC03 WITH RADIAL TAPING LEAD BENDING STYLE = RT (Radial Taped) DIMENSIONS in millimeters P H1 L1 Pitch of components P 12.7 ± 1.0 Lead spacing F 5.0 + 0.4, - 0.2 Width of carrier tape W 18.0 ± 0.5 Height for cutting (max.) L1 11 Height for insertion (max.) H1 32 F W Revision: 07-Dec-2020 Document Number: 28730 11 For technical questions, contact: ww1resistors@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 Legal Disclaimer Notice www.vishay.com Vishay Disclaimer ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability. Statements regarding the suitability of products for certain types of applications are based on Vishay's knowledge of typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer's responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and / or specifications may vary in different applications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer's technical experts. Product specifications do not expand or otherwise modify Vishay's terms and conditions of purchase, including but not limited to the warranty expressed therein. Hyperlinks included in this datasheet may direct users to third-party websites. These links are provided as a convenience and for informational purposes only. Inclusion of these hyperlinks does not constitute an endorsement or an approval by Vishay of any of the products, services or opinions of the corporation, organization or individual associated with the third-party website. Vishay disclaims any and all liability and bears no responsibility for the accuracy, legality or content of the third-party website or for that of subsequent links. Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Vishay product could result in personal injury or death. Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners. © 2022 VISHAY INTERTECHNOLOGY, INC. ALL RIGHTS RESERVED Revision: 01-Jan-2022 1 Document Number: 91000
AC01000001800JA100 价格&库存

很抱歉,暂时无法提供与“AC01000001800JA100”相匹配的价格&库存,您可以联系我们找货

免费人工找货