0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
TOP100-15

TOP100-15

  • 厂商:

    TRUMPOWER

  • 封装:

  • 描述:

    TOP100-15 - 60-96 WATT AC/DC SWITCHING POWER SUPPLIES - Tumbler Technologies + TRUMPower

  • 数据手册
  • 价格&库存
TOP100-15 数据手册
T 100W Single Output Switching Power AC/DC P L N - 1 0 0 series TOP100 Series 60-96 WATTSupply SWITCHING POWER SUPPLIES Universal AC input / Full range Protections: Short circuit / Overload / Over voltage / Over temperature Built-in active PFC function IP64 design for indoor or outdoor installations UL1310 Class 2 power unit Cooling by free air convection 100% full load burn-in test High reliability Suitable for LED lighting and moving sign applications 2 years warranty Features : SPECIFICATION MODEL P/N DC VOLTAGE F 110 M M EQUIVALENT SELV LPS ( for 48V only) ( except for 48V ) IP64 PLN-100-36 TOP100-36 36V 18 ~ 36V 2.65A 0 ~ 2.65A 95.4W 150mVp-p PLN-100-48 TOP100-48 48V 24 ~ 48V 2A 0 ~ 2A 96W 200mVp-p OUTPUT PLN-100-12 PLN-100-15 PLN-100-20 PLN-100-24 TOP100-12 TOP100-15 TOP100-20 TOP100-24 12V 15V 20V 24V CONSTANT CURRENT REGION Note.7 6 ~ 12V 7.5 ~ 15V 10 ~ 20V 12 ~ 24V RATED CURRENT 5A 4.8A 4A Note.6 5A 0 ~ 5A 0 ~ 4.8A 0 ~ 4A CURRENT RANGE Note.6 0 ~ 5A 75W 96W 96W RATED POWER Note.6 60W 150mVp-p 150mVp-p 150mVp-p RIPPLE & NOISE (max.) Note.2 150mVp-p 0% ~ -15%. Can be adjusted by internal potential meter SVR1 VOLTAGE ADJ. RANGE 3% ~ -25%. Can be adjusted by internal potential meter SVR2 CURRENT ADJ. RANGE VOLTAGE TOLERANCE Note.3 3.0% 3.0% 3.0% 3.0% 1.0% LINE REGULATION 2.0% LOAD REGULATION 1200ms, 80ms/230VAC 1200ms, 80ms/115VAC at full load SETUP, RISE TIME 60ms/230VAC 30ms/115VAC at full load HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE POWER FACTOR (Typ.) Note.5 90 ~ 264VAC PLN-100-27 TOP100-27 27V 13.5 ~ 27V 3.55A 0 ~ 3.55A 95.85W 150mVp-p 3.0% 2.0% 2.0% 127 ~ 370VDC PF>0.95/115VAC at full load 85% 87% 87% 87% 0.45A/230VAC 87% 20V ~ 48V:1.1A/115VAC 87% 0.55A/230VAC 15V:0.9A/115VAC 47 ~ 63Hz PF>0.95/230VAC 83% INPUT EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVER CURRENT Note.4 12V:0.8A/115VAC 0.4A/230VAC COLD START 40A/230VAC 0.5mA / 240VAC 95 ~ 100% PROTECTION OVER VOLTAGE OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & EMC WITHSTAND VOLTAGE ISOLATION RESISTANCE Protection type : Constant current limiting, recovers automatically after fault condition is removed 13 ~ 16V 16.5 ~ 20V 22 ~ 27V 27 ~ 34V 29 ~ 36V 39 ~ 48V Protection type : Shut down and latch off o/p voltage, re-power on to recover 90 10 (RTH2) (Refer to output load derating curve) , 10 ~ 95% RH (0 ~ 50 ) Protection type : Shut down o/p voltage, re-power on to recover -30 ~ +50 -40 ~ +80 0.03%/ 20 ~ 90% RH non-condensing 52 ~ 64V 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL1310 Class 2, UL879 ( listed in UL Sign Components Manual (SAM) ), TUV EN60950-1, EN61347-1, EN61347-2-13 CAN/CSA C22.2 No. 223-M91(except for 48V), IP64 approved I/P-O/P:4.25KVDC I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH EMI CONDUCTION & RADIATION Compliance to EN55015, EN55022 (CISPR22) Class B HARMONIC CURRENT Compliance to EN61000-3-2 Class C (>50% load) ; EN61000-3-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61547, EN55024, light industry level, criteria A EMS IMMUNITY MTBF 303.1Khrs min. MIL-HDBK-217F (25 ) DIMENSION PACKING 200*70.5*35mm (L*W*H) 0.52Kg; 20pcs/11.4Kg/0.76CUFT OTHERS NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Please refer to OLP characteristics. 5. Derating may be needed under low input voltage. Please check the derating curve for more details. 6. This is the maximum possible output current and power. Over load protection may be activated slightly below this level to comply with the requirement of UL1310 class 2. 7. Constant current operation region is within 50% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design. File Name:PLN-100-SPEC 2008-08-18 T 100W Single Output 60-96 WATT Supply ser TOP100 Series Switching Power AC/DC SWITCHING POWER SUPPLIES i e s PLN-100 Case No.955A Mechanical Specification 200 6.26 Unit:mm 22.84 2-R2.5 AC/L(Brown) AC/N(Blue) FG (Greed/Yellow) 70.5 310 10 DC OUT 310 10 +V(Red) -V(Black) AC IN 18AWG 2C 6.26 22.84 18AWG 3C Output voltage and current adjustment : remove the upper case and adjust through SVR1 & SVR2 shown in the diagram. SVR1 SVR2 SVR1 Output voltage adjustment SVR2 Output current adjustment Block Diagram POWER SWITCHING RECTIFIERS & FILTER O.L.P. FG PFC CONTROL DETECTION CIRCUIT O.V.P. Fosc : 100KHz I/P EMI FILTER & RECTIFIERS PFC CIRCUIT 35 +V -V O.L.P. PWM & PFC CONTROL Derating Curve Static Characteristics Ta=25 100 100 90 80 80 70 60 LOAD (%) LOAD (%) -15 -5 0 15 30 40 50 (HORIZONTAL) 40 60 50 40 20 -30 90 100 125 135 145 155 165 175 180 200 230 264 AMBIENT TEMPERATURE ( ) INPUT VOLTAGE (V) 60Hz File Name:PLN-100-SPEC 2008-08-18
TOP100-15 价格&库存

很抱歉,暂时无法提供与“TOP100-15”相匹配的价格&库存,您可以联系我们找货

免费人工找货