0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
BCM380P475T800A31

BCM380P475T800A31

  • 厂商:

    VICOR

  • 封装:

    -

  • 描述:

    DC/DC CONVERTER 47.5V 800W

  • 数据手册
  • 价格&库存
BCM380P475T800A31 数据手册
BCM® Bus Converter BCM380y475x800A31 ® S US C C NRTL US Fixed Ratio DC-DC Converter Features Product Ratings • Up to 800 W continuous output power • 1250 W/in3 power density VIN = 380 V (260 – 410 V) POUT = up to 800 W VOUT = 47.5 V (32.5 – 51.3 V) (NO LOAD) K = 1/8 • 97.7% peak efficiency • 4242 Vdc isolation • Parallel operation for multi-kW arrays • OV, OC, UV, short circuit and thermal protection • 6123 through-hole ChiP package n 2.494” x 0.898” x 0.286” Product Description The VI Chip® Bus Converter (BCM) is a high efficiency Sine Amplitude Converter (SAC), operating from a 260 to 410 VDC primary bus to deliver an isolated ratiometric output from 32.5 to 51.3 VDC. (63.34 mm x 22.80 mm x 7.26 mm) • PMBusTM management interface* The BCM380y475x800A31 offers low noise, fast transient response, and industry leading efficiency and power density. In addition, it provides an AC impedance beyond the bandwidth of most downstream regulators, allowing input capacitance normally located at the input of a POL regulator to be located at the input of the BCM module. With a K factor of 1/8, that capacitance value can be reduced by a factor of 64x, resulting in savings of board area, material and total system cost. Typical Applications • 380 DC Power Distribution • High End Computing Systems • Automated Test Equipment • Industrial Systems The BCM380y475x800A31, combined with the D44TL1A0 Digital Supervisor and I13TL1A0 Digital Isolator, provide a secondary referenced PMBus™ compatible telemetry and control interface. This interface provides access to the BCM’s internal controller configuration, fault monitoring, and other telemetry functions. • High Density Power Supplies • Communications Systems • Transportation Leveraging the thermal and density benefits of Vicor’s ChiP packaging technology, the BCM module offers flexible thermal management options with very low top and bottom side thermal impedances. Thermally-adept ChiP-based power components, enable customers to achieve low cost power system solutions with previously unattainable system size, weight and efficiency attributes, quickly and predictably. *When used with D44TL1A0 and I13TL1A0 chipset BCM® Bus Converter Rev 1.3 vicorpower.com Page 1 of 23 05/2015 800 927.9474 BCM380y475x800A31 Typical Application PRM BCM SER-OUT ENABLE enable/disable switch SER-OUT VAUX SER-IN enable/disable switch SHARE/ CONTROL NODE SGND R SER-IN R R TRIM_PRM +OUT VC PC IFB R I_PRM_DAMP FUSE OUT TM VTM Start Up Pulse VC AL_PRM V Adaptive Loop Temperature Feedback VT AL EN VTM REF/ REF_EN TRIM C O_PRM_DAMP O_VTM_CER LOAD PRM_SGND +IN +OUT –IN –OUT L V C IN PRIMARY +OUT –IN –OUT +IN L I_PRM_FLT R I_BCM_ELEC SOURCE_RTN +IN O_PRM_FLT I_PRM_CER SGND C O_PRM_CER –IN –OUT PRIMARY SECONDARY LOAD_RTN ISOLATION BOUNDRY ISOLATION BOUNDRY Digital Supervisor Digital Isolator NC SECONDARY PRI_OUT_A SEC_IN_A PRI_OUT_B SEC_IN_B TX PRI_IN_C SEC_OUT_C RX PRI_COM SEC_COM PRM_SGND Host µC t VDDB SER-IN + V – VDD EXT SER-OUT SGND PMBus SGND PMBus SGND SGND SGND BCM380y475x800A31 + PRM + VTM, Adaptive Loop Configuration V BCM SER-OUT REF 3312 IN VAUX ENABLE enable/disable switch SER-IN enable/disable switch SER-IN AL VT SHARE/ CONTROL NODE VC Voltage Sense and Error Amplifier (Differential) VTM SGND TM +OUT Voltage Reference with Soft Start PRM_SGND R OUT GND REF/ REF_EN TRIM EN SGND SGND IFB VTM Start up Pulse V+ V– VC PC VOUT I_PRM_DAMP +IN –IN R SGND C O_PRM_DAMP FUSE V IN +IN +OUT –IN –OUT +IN L C I_BCM_ELEC I_PRM_FLT C +IN +OUT External Current Sense I_PRM_ELEC L O_PRM_FLT C O_PRM_CER –IN –OUT –IN SGND –OUT PRIMARY SOURCE_RTN PRIMARY SECONDARY ISOLATION BOUNDRY PRI_OUT_A Digital Supervisor PRM_SGND Host μC SEC_IN_A VDDB SEC_IN_B TX VDD PRI_IN_C SEC_OUT_C RX PRI_COM SEC_COM t SER-IN + PRI_OUT_B SECONDARY ISOLATION BOUNDRY Digital Isolator NC Voltage Sense SER-OUT REF SGND PRM – V EXT SER-OUT SGND SGND PMBus PMBus SGND SGND SGND BCM380y475x800A31 + PRM + VTM, Remote Sense Configuration BCM® Bus Converter Rev 1.3 vicorpower.com Page 2 of 23 05/2015 800 927.9474 O_VTM_CER LOAD BCM380y475x800A31 Pin Configuration TOP VIEW 1 2 +IN A A’ +OUT SER-OUT B B’ -OUT EN C SER-IN D -IN E C’ +OUT D’ -OUT 6123 ChiP Package Pin Descriptions Pin Number Signal Name Type Function A1 +IN INPUT POWER B1 SER-OUT OUTPUT C1 EN INPUT Enables and disables power supply; Primary side referenced signals D1 SER-IN INPUT UART receive pin; Primary side referenced signals E1 -IN INPUT POWER RETURN Negative input power terminal A’2, C’2 +OUT OUTPUT POWER Positive output power terminal B’2, D’2 -OUT OUTPUT POWER RETURN Negative output power terminal Positive input power terminal UART transmit pin; Primary side referenced signals BCM® Bus Converter Rev 1.3 vicorpower.com Page 3 of 23 05/2015 800 927.9474 BCM380y475x800A31 Part Ordering Information Device Input Voltage Range Package Type Output Voltage x 10 Temperature Grade Output Power Revision Package Size Version BCM 380 y 475 x 800 A 3 1 BCM = BCM 380 = 260 to 410 V P = ChiP Through Hole 475 = 47.5 V T = -40 to 125°C M = -55 to 125°C 800 = 800 W A 3 = 6123 1 All products shipped in JEDEC standard high profile (0.400” thick) trays (JEDEC Publication 95, Design Guide 4.10). Standard Models Part Number VIN Package Type VOUT Temperature Power Package Size BCM380P475T800A31 260 to 410 V ChiP Through Hole 47.5 V 32.5 to 51.3 V -40°C to 125°C 800 W 6123 BCM380P475M800A31 260 to 410 V ChiP Through Hole 47.5 V 32.5 to 51.3 V -55°C to 125°C 800 W 6123 Absolute Maximum Ratings The absolute maximum ratings below are stress ratings only. Operation at or beyond these maximum ratings can cause permanent damage to the device. Parameter Comments +IN to –IN Min Max Unit -1 480 V 1000 V/ms 4242 V VIN slew rate (operational) Isolation voltage, input to output Dielectric test applied to 100% production units +OUT to –OUT -1 60 V SER-OUT to –IN -0.3 4.6 V EN to –IN -0.3 5.5 V SER-IN to –IN -0.3 4.6 V BCM® Bus Converter Rev 1.3 vicorpower.com Page 4 of 23 05/2015 800 927.9474 BCM380y475x800A31 Electrical Specifications Specifications apply over all line and load conditions, unless otherwise noted; Boldface specifications apply over the temperature range of -40°C ≤ TINTERNAL ≤ 125°C (T-Grade); All other specifications are at TINTERNAL = 25ºC unless otherwise noted. Attribute Symbol Conditions / Notes Min Typ Max Unit 260 410 V 260 410 V 120 V Powertrain Input voltage range, continuous Input voltage range, transient VIN_DC VIN_TRANS Full current or power supported, 50 ms max, 10% duty cycle max VIN µController Active Quiescent current VµC_ACTIVE VIN voltage where µC is initialized, (ie VAUX = Low, powertrain inactive) Disabled, EN Low, VIN = 380 V IQ 2 TINTERNAL ≤ 100ºC VIN = 380 V, TINTERNAL = 25ºC No load power dissipation Inrush current peak VIN = 380 V PNL IINR_P 8.9 5 Transformation ratio Output power (continuous) Output power (pulsed) Output current (continuous) Output current (pulsed) Efficiency (ambient) Efficiency (hot) Efficiency (over load range) Output resistance Switching frequency IIN_DC K VIN = 260 V to 410 V, TINTERNAL = 25ºC 15 VIN = 260 V to 410 V 20 VIN = 410 V, COUT = 100 µF, RLOAD = 25% of full load current 6 At POUT = 800 W, TINTERNAL ≤ 100ºC Input inductance (parasitic) Output inductance (parasitic) 2.25 10 ms pulse, 25% Duty cycle, PTOTAL = 50% rated POUT_DC IOUT_DC 800 W 1000 W 16.9 A 21 A 96.5 VIN = 260 V to 410 V, IOUT = 16.9 A 95.3 VIN = 380 V, IOUT = 8.45 A 96.5 97.5 hHOT h20% VIN = 380 V, IOUT = 16.9 A, TINTERNAL = 100°C 96.3 97.1 3 A < IOUT < 16.9 A, TINTERNAL ≤ 100ºC 92 ROUT_COLD VIN = 380 V, IOUT = 16.9 A, TINTERNAL = -40°C 10 ROUT_AMB VIN = 380 V, IOUT = 16.9 A 12 35 58 ROUT_HOT VIN = 380 V, IOUT = 16.9 A, TINTERNAL = 100°C 24 43 60 1.12 1.18 1.24 hAMB FSW Frequency of the Output Voltage Ripple = 2x FSW VOUT_PP LIN_PAR LOUT_PAR Input Series inductance (internal) LIN_INT Effective Input capacitance (internal) CIN_INT A V/V 10 ms pulse, 25% Duty cycle, ITOTAL = 50% rated IOUT_DC VIN = 380 V, IOUT = 16.9 A COUT = 0 F, IOUT = 16.9 A, VIN = 380 V, Output voltage ripple A 1/8 POUT_DC IOUT_PULSE W 12 K = VOUT / VIN, at no load POUT_PULSE 12 16 TINTERNAL ≤ 100ºC DC input current mA 4 97.4 % % % 19 33 mΩ MHz 250 20 MHz BW mV TINTERNAL ≤ 100ºC Frequency 2.5 MHz (double switching frequency), Simulated lead model Frequency 2.5 MHz (double switching frequency), Simulated lead model Reduces the need for input decoupling inductance in BCM arrays Effective value at 380 VIN BCM® Bus Converter Rev 1.3 vicorpower.com Page 5 of 23 05/2015 800 927.9474 350 6.7 nH 1.3 nH 0.56 µH 0.25 µF BCM380y475x800A31 Electrical Specifications (Cont.) Specifications apply over all line and load conditions, unless otherwise noted; Boldface specifications apply over the temperature range of -40°C ≤ TINTERNAL ≤ 125°C (T-Grade); All other specifications are at TINTERNAL = 25ºC unless otherwise noted. Attribute Symbol Effective Output capacitance (internal) COUT_INT Effective Output capacitance (external) COUT_EXT Array Maximum external output capacitance COUT_AEXT Auto Restart Time Input overvoltage lockout threshold tAUTO_RESTART Conditions / Notes Powertrain (Cont.) Effective value at 47.5 VOUT Excessive capacitance may drive module into SC protection Min Typ Max 12.8 µF 0 100 µF 292.5 357.5 ms V COUT_AEXT Max = N * 0.5*COUT_EXT Max Powertrain Protection Startup into a persistent fault condition. Non-Latching fault detection given VIN > VIN_UVLO+, Module will ignore attempts to re-enable during time off VIN_OVLO+ 430 440 450 Input overvoltage recovery threshold VIN_OVLO- 420 430 440 Input overvoltage lockout hysteresis VIN_OVLO_HYST Overvoltage lockout response time tOVLO Soft-Start time tSOFT-START Output overcurrent trip threshold IOCP Overcurrent Response Time Constant tOCP Short circuit protection trip threshold ISCP Short circuit protection response time tSCP Overtemperature shutdown threshold tOTP Unit From powertrain active Fast Current limit protection disabled during Soft-Start 18 Effective internal RC filter V 10 µs 1 ms 23.7 40 3.6 A ms 30 A 1 Temperature sensor located inside controller IC V 10 µs ºC 125 Powertrain Supervisory Limits Input overvoltage lockout threshold VIN_OVLO+ 420 Input overvoltage recovery threshold VIN_OVLO- 405 Input overvoltage lockout hysteresis VIN_OVLO_HYST Overvoltage lockout response time Input undervoltage lockout threshold 434.5 450 424 440 10.5 tOVLO 100 µs 200 226 250 Input undervoltage recovery threshold VIN_UVLO+ 225 244 259 Input undervoltage lockout hysteresis VIN_UVLO_HYST Undervoltage lockout response time tUVLO Undervoltage startup delay tUVLO+_DELAY Output Overcurrent Trip Threshold IOCP Overcurrent Response Time Constant tOCP Overtemperature shutdown threshold tOTP Temperature sensor located inside controller IC Undertemperature shutdown threshold tUTP Temperature sensor located inside controller IC Startup into a persistent fault condition. Non-Latching fault detection given VIN > VIN_UVLO+ Undertemperature restart time 20 tUTP_RESTART Rev 1.3 vicorpower.com Page 6 of 23 05/2015 800 927.9474 V V 15 V 100 µs 20 ms 22 24 3.6 BCM® Bus Converter V V VIN_UVLO- From VIN = VIN_UVLO+ to powertrain active, EN floating, (i.e One time Startup delay from application of VIN to VOUT) V A ms 125 ºC -45 3 ºC s BCM380y475x800A31 1000 Output Power (W) 800 600 400 200 0 35 45 55 65 75 85 95 105 115 125 Case Temperature (°C) One side cooling One side cooling and leads Double Sided cooling and leads Figure 1 — Specified thermal operating area 22 1200 20 1000 Output Current (A) Output Power (W) 1100 900 800 700 600 500 18 16 14 12 400 10 260 300 260 275 290 305 320 335 350 365 380 395 410 275 290 320 IOUT_DC POUT_PULSE Figure 2 — Specified electrical operating area using rated ROUT_HOT Output Capacitance (% Rated COUT MAX) 335 350 365 Input Voltage (V) Input Voltage (V) POUT_DC 305 110 100 90 80 70 60 50 40 30 20 10 0 0 10 20 30 40 50 60 70 80 90 Load Current (% IOUT_AVG) Figure 3 — Specified Primary start-up into load current and external capacitance BCM® Bus Converter Rev 1.3 vicorpower.com Page 7 of 23 05/2015 800 927.9474 100 110 IOUT_PULSE 380 395 410 BCM380y475x800A31 Reported Characteristics Specifications apply over all line, load conditions, unless otherwise noted; Boldface specifications apply over the temperature range of -40°C ≤ TINTERNAL ≤ 125°C (T-Grade); All other specifications are at TINTERNAL = 25ºC unless otherwise noted. Monitored Telemetry • The BCM communication version is not intended to be used without a Digital Supervisor. ACCURACY (RATED RANGE) FUNCTIONAL REPORTING RANGE UPDATE PMBusTM READ COMMAND Input voltage (88h) READ_VIN ± 5%(LL - HL) 130 V to 450 V 100 µs VACTUAL = VREPORTED x 10-1 Input current (89h) READ_IIN ± 20%(10 - 20% of FL) ± 5%(20 - 133% of FL) - 0.42 A to 2.9 A 100 µs IACTUAL = IREPORTED x 10-3 Output voltage[1] (8Bh) READ_VOUT ± 5%(LL - HL) 16.25 V to 56.25 V 100 µs VACTUAL = VREPORTED x 10-1 Output current (8Ch) READ_IOUT ± 20%(10 - 20% of FL) ± 5%(20 - 133% of FL) - 3.5 A to 22.5 A 100 µs IACTUALL = IREPORTED x 10-2 Output resistance (D4h) READ_ROUT ± 5%(50 - 100% of FL) at NL ± 10%(50 - 100% of FL)(LL - HL) 2 mΩ to 50 mΩ 100 ms RACTUAL = RREPORTED x 10-5 (8Dh) READ_TEMPERATURE_1 ± 7°C(Full Range) - 55ºC to 130ºC 100 ms TACTUAL = TREPORTED ATTRIBUTE Temperature[2] [1] [2] DIGITAL SUPERVISOR RATE REPORTED UNITS Default READ Output Voltage returned when unit is disabled = -300 V. Default READ Temperature returned when unit is disabled = -273°C. Variable Parameter • Factory setting of all below Thresholds and Warning limits are 100% of listed protection values. • Variables can be written only when module is disabled either EN pulled low or VIN < VIN_UVLO-. • Module must remain in a disabled mode for 3 ms after any changes to the below variables allowing ample time to commit changes to EEPROM. ATTRIBUTE DIGITAL SUPERVISOR PMBusTM COMMAND [3] Input / Output Overvoltage Protection Limit (55h) VIN_OV_FAULT_LIMIT Input / Output Overvoltage Warning Limit (57h) VIN_OV_WARN_LIMIT Input / Output Undervoltage Protection Limit (D7h) DISABLE_FAULTS CONDITIONS / NOTES ACCURACY (RATED RANGE) FUNCTIONAL REPORTING RANGE DEFAULT ± 5%(LL - HL) 130 V to 435 V 100% ± 5%(LL - HL) 130 V to 435 V 100% ± 5%(LL - HL) 130 V or 260 V 100% VIN_OVLO- is automatically 3% lower than this set point Can only be disabled to a preset default value VALUE Input Overcurrent Protection Limit (5Bh) IIN_OC_FAULT_LIMIT ± 20%(10 - 20% of FL) ± 5%(20 - 133% of FL) 0.21 to 0.42 A 0.42 to 2.810 A 100% Input Overcurrent Warning Limit (5Dh) IIN_OC_WARN_LIMIT ± 20%(10 - 20% of FL) ± 5%(20 - 133% of FL) 0.21 to 0.42 A 0.42 to 2.810 A 100% Overtemperature Protection Limit (4Fh) OT_FAULT_LIMIT ± 7°C(Full Range) 0 to 125°C 100% Overtemperature Warning Limit (51h) OT_WARN_LIMIT ± 7°C(Full Range) 0 to 125°C 100% ± 50 µs 0 to 100 ms 0 ms Turn on Delay [3] (60h) TON_DELAY Additional time delay to the Undervoltage Startup Delay Refer to Digital Supervisor datasheet for complete list of supported commands. BCM® Bus Converter Rev 1.3 vicorpower.com Page 8 of 23 05/2015 800 927.9474 BCM380y475x800A31 Signal Characteristics Specifications apply over all line, load conditions, unless otherwise noted; Boldface specifications apply over the temperature range of -40°C ≤ TINTERNAL ≤ 125°C (T-Grade); All other specifications are at TINTERNAL = 25ºC unless otherwise noted. UART SER-IN / SER-OUT Pins • Universal Asynchronous Receiver/Transmitter (UART) pins. • The BCM communication version is not intended to be used without a Digital Supervisor. • Isolated I2C communication and telemetry is available when using Vicor Digital Isolator and Vicor Digital Supervisor. Please see specific product data sheet for more details. • UART SER-IN pin is internally pulled high using a 1.5 kΩ to 3.3 V. SIGNAL TYPE STATE GENERAL I/O ATTRIBUTE SYMBOL Baud Rate CONDITIONS / NOTES BRUART MIN Rate TYP MAX 750 UNIT Kbit/s SER-IN Pin VSER-IN_IH 2.3 V SER-IN Input Voltage Range VSER-IN_IL DIGITAL 1 V SER-IN rise time tSER-IN_RISE 10% to 90% 400 ns SER-IN fall time tSER-IN_FALL 10% to 90% 25 ns SER-IN RPULLUP RSER-IN_PLP Pull up to 3.3 V 1.5 kΩ SER-IN External Capacitance CSER-IN_EXT INPUT Regular Operation pF SER-OUT Pin VSER-OUT_OH 0 mA ≥ IOH ≥ -4 mA VSER-OUT_OL 0 mA ≤ IOL ≤ 4 mA SER-OUT rise time tSER-OUT_RISE 10% to 90% 55 ns SER-OUT fall time tSER-OUT_FALL 10% to 90% 45 ns SER-OUT Output Voltage Range DIGITAL OUTPUT 400 SER-OUT source current ISER-OUT SER-OUT output impedance ZSER-OUT 2.8 V 0.5 VSER-OUT = 2.8 V 6 120 V mA Ω Enable / Disable Control • The EN pin is a standard analog I/O configured as an input to an internal µC. • It is internally pulled high to 3.3 V. • When held low the BCM internal bias will be disabled and the powertrain will be inactive. • In an array of BCMs, EN pins should be interconnected to synchronize startup and permit startup into full load conditions. • Enable / disable command will have no effect if the EN pin is disabled. SIGNAL TYPE STATE ATTRIBUTE SYMBOL CONDITIONS / NOTES Startup EN to Powertrain active time tEN_START VIN > VIN_UVLO+, EN held low both conditions satisfied for t > tUVLO+_DELAY EN Voltage Threshold VENABLE EN Resistance (Internal) REN_INT ANALOG INPUT Regular Operation EN Disable Threshold MIN TYP MAX 250 µs 2.3 Internal pull up resistor VEN_DISABLE_TH BCM® Bus Converter Rev 1.3 vicorpower.com Page 9 of 23 05/2015 800 927.9474 UNIT V 1.5 kΩ 1 V OUTPUT BIDIR INPUT VOUT EN +IN VμC STARTUP VIN_UVLO- VIN_OVLO- OVER VOLTAGE VIN_OVLO+ VNOM tUVLO+_DELAY VIN_UVLO+ p l -u O N Pu l E RN AL AG TU R N N T L O E E NVO AG INT E R IZ TUR LT IN L E O IA V EROV IT U T UT & S I N TP UT P P U c I N EN µ O IN BCM® Bus Converter Rev 1.3 vicorpower.com Page 10 of 23 05/2015 800 927.9474 tAUTO-RESTART ENABLE CONTROL OVER CURRENT tWAIT ≥ tENABLE_OFF tSCP SHUTDOWN F OF NT NH E R W G EV TU LO HI E IT T D ED G R U E A A L L LL RC LT ST U CI PU RE T VO E LE P R L T T O AB AB PU PU SH IN IN E N EN BCM380y475x800A31 BCM Module Timing diagram BCM380y475x800A31 High Level Functional State Diagram Conditions that cause state transitions are shown along arrows. Sub-sequence activities listed inside the state bubbles. Application of VIN VμC < VIN < VIN_UVLO+ STARTUP SEQUENCE VIN > VIN_UVLO+ STANDBY SEQUENCE EN High EN High Powertrain Stopped Powertrain Stopped ENABLE falling edge, or OTP detected tUVLO+_DELAY expired ONE TIME DELAY INITIAL STARTUP Input OVLO or UVLO, Output OCP, or UTP detected Fault Autorecovery ENABLE falling edge, or OTP detected FAULT SEQUENCE Input OVLO or UVLO, Output OCP, or UTP detected EN High Powertrain Stopped SUSTAINED OPERATION EN High Powertrain Active Short Circuit detected BCM® Bus Converter Rev 1.3 vicorpower.com Page 11 of 23 05/2015 800 927.9474 BCM380y475x800A31 Application Characteristics 15 14 13 12 11 10 9 8 7 6 5 4 3 98.0 Full Load Efficiency (%) 97.5 97.0 96.5 96.0 260 275 290 305 320 335 350 365 380 395 -40 410 -20 0 Input Voltage (V) - 40°C 25°C VIN: 90°C 45 96 40 94 35 92 30 90 25 PD 20 86 15 84 10 82 5 80 0 0.0 1.7 3.4 5.1 6.8 8.5 Power Dissipation (W) Efficiency (%) 98 88 35 92 30 90 35 92 30 90 25 PD 20 86 15 84 10 82 5 80 0 6.8 8.5 15 84 10 82 5 0 1.7 3.4 260 V 10.1 11.8 13.5 15.2 16.9 380 V 5.1 6.8 8.5 260 V 10.1 11.8 13.5 15.2 16.9 380 V 410 V Figure 7 — Efficiency and power dissipation at TCASE = 25°C 50 40 30 20 10 0 -40 -20 Load Current (A) VIN : 20 86 0.0 Power Dissipation (W) Efficiency (%) 40 94 5.1 25 PD 88 Load Current (A) 96 3.4 410 V 40 VIN : 45 1.7 380 V 94 410 V 98 0.0 260 V 80 Figure 6 — Efficiency and power dissipation at TCASE = -40°C 88 100 45 10.1 11.8 13.5 15.2 16.9 380 V 80 96 ROUT (mΩ) 260 V 60 98 Load Current (A) VIN : 40 Figure 5 — Full load efficiency vs. temperature; VIN Figure 4 — No load power dissipation vs. VIN Efficiency (%) TTOP SURFACE CASE: 20 Case Temperature (ºC) 0 20 40 60 Case Temperature (°C) 410 V Figure 8 — Efficiency and power dissipation at TCASE = 90°C IOUT: 16.9 A Figure 9 — ROUT vs. temperature; Nominal VIN BCM® Bus Converter Rev 1.3 vicorpower.com Page 12 of 23 05/2015 800 927.9474 80 100 Power Dissipation (W) Power Dissipation (W) Product is mounted and temperature controlled via top side cold plate, unless otherwise noted. See associated figures for general trend data. BCM380y475x800A31 Voltage Ripple (mVPK-PK) 350 300 250 200 150 100 50 0 0.0 1.7 3.4 5.1 6.8 8.5 10.1 11.8 13.5 15.2 16.9 Load Current (A) VIN: 380 V Figure 10 — VRIPPLE vs. IOUT ; No external COUT. Board mounted module, scope setting : 20 MHz analog BW Figure 11 — Full load ripple, 270 µF CIN; No external COUT. Board mounted module, scope setting : 20 MHz analog BW Figure 12 — 0 A– 16.9 A transient response: CIN = 270 µF, no external COUT Figure 13 — 16.9 A – 0 A transient response: CIN = 270 µF, no external COUT Figure 14 — Start up from application of VIN = 380 V, 50% IOUT, 100% COUT Figure 15 — Start up from application of EN with pre-applied VIN = 380 V, 50% IOUT, 100% COUT BCM® Bus Converter Rev 1.3 vicorpower.com Page 13 of 23 05/2015 800 927.9474 BCM380y475x800A31 General Characteristics Specifications apply over all line, load conditions, unless otherwise noted; Boldface specifications apply over the temperature range of -40°C ≤ TINTERNAL ≤ 125°C (T-Grade); All other specifications are at TINTERNAL = 25ºC unless otherwise noted. Attribute Symbol Conditions / Notes Min Typ Max Unit Mechanical Length L 62.96 / [2.479] 63.34 / [2.494] 63.72 / [2.509] mm / [in] Width W 22.67 / [0.893] 22.80 / [0.898] 22.93 / [0.903] mm / [in] Height H 7.21 / [0.284] 7.26 / [0.286] 7.31 / [0.288] mm / [in] Volume Vol 10.48 / [0.640] cm3/ [in3] Weight W 41 / [1.45] g / [oz] Without heatsink Lead finish Nickel 0.51 2.03 Palladium 0.02 0.15 Gold 0.003 0.051 BCM380P475T800A31 (T-Grade) -40 125 °C BCM380P475M800A31 (M-Grade) Estimated thermal resistance to maximum temperature internal component from isothermal top -55 125 °C µm Thermal Operating temperature Thermal resistance top side Thermal resistance leads Thermal resistance bottom side TINTERNAL fINT-TOP fINT-LEADS fINT-BOTTOM 1.64 °C/W Estimated thermal resistance to maximum temperature internal component from isothermal leads 8.51 °C/W Estimated thermal resistance to maximum temperature internal component from isothermal bottom 2.55 °C/W 34 Ws /°C Thermal capacity Assembly Storage Temperature TST ESDHBM ESD Withstand ESDCDM BCM380P475T800A31 (T-Grade) -55 125 °C BCM380P475M800A31 (M-Grade) -65 125 °C Human Body Model, "ESDA / JEDEC JDS-001-2012" Class I-C (1kV to < 2 kV) Charge Device Model, "JESD 22-C101-E" Class II (200V to < 500V) BCM® Bus Converter Rev 1.3 vicorpower.com Page 14 of 23 05/2015 800 927.9474 BCM380y475x800A31 General Characteristics (Cont.) Specifications apply over all line, load conditions, unless otherwise noted; Boldface specifications apply over the temperature range of -40°C ≤ TINTERNAL ≤ 125°C (T-Grade); All other specifications are at TINTERNAL = 25ºC unless otherwise noted. Attribute Symbol Conditions / Notes Min Typ Max Unit 135 °C Soldering [1] Peak temperature Top case Safety Isolation voltage VHIPOT IN to OUT 4,242 IN to CASE 2,121 OUT to CASE 2,121 Isolation capacitance CIN_OUT Unpowered unit 620 Isolation resistance RIN_OUT At 500 Vdc MIL-HDBK-217Plus Parts Count 25°C Ground Benign, Stationary, Indoors / Computer 10 MTBF Telcordia Issue 2 - Method I Case III; 25°C Ground Benign, Controlled Agency approvals / standards [1] VDC 780 BCM® Bus Converter Rev 1.3 vicorpower.com Page 15 of 23 05/2015 800 927.9474 pF MΩ 2.18 MHrs 7.85 MHrs cTUVus cURus CE Marked for Low Voltage Directive and RoHS Recast Directive, as applicable Product is not intended for reflow solder attach. 940 SER-IN -VIN EN 1.5 kΩ BCM® Bus Converter Rev 1.3 vicorpower.com Page 16 of 23 05/2015 800 927.9474 -Vcc Startup / Re-start Delay Over-Temp Under-Temp Cntrl Output Overcurrent SEPIC EN Over Voltage UnderVoltage SER-IN EN SER-OUT Current Flow detection + Forward IIN sense 1.5 kΩ SER-OUT 3.3v Linear Regulator Digital Controller SEPIC Modulator Differential Current Sensing Fast Current Limit Slow Current Limit Soft-Start Temperature Sensor +Vcc Startup Circuit ( +VIN /4 ) - X On/Off +VIN /4 Analog Controller +VIN Primary and Secondary Gate Drive Transformer C10 C09 C08 Cr C07 IIN Lr +VIN /4 C06 C05 C04 C03 C02 C01 Primary Stage L01 Q08 Q07 Q06 Q05 Q04 Q03 Q02 Q01 Q10 Q09 Secondary Stage Q12 Q11 Full-Bridge Synchronous Rectification COUT -VOUT +VOUT BCM380y475x800A31 BCM Module Block Diagram BCM380y475x800A31 System Diagram -OUT BCM SER-OUT -IN BCM SEC-IN-B TX D 1 ’ SEC-OUT-C RXD1 PRI-OUT-B PRI-IN-C PRI-COM SEC-COM RXD4 VDDB RXD3 VDD RXD2 NC D44TL1A0 RXD1 VDD TXD4 NC NC TXD3 SSTOP SDA 5V EXT NC SEC-IN-A PRI-OUT-A SDA NC SER-IN SCL BCM EN NC Digital Isolator SGND SCL 3 kΩ 3 kΩ VDD CP D Q SGND VCC D Flip-flop FDG6318P R2 10 kΩ NC SADDR NC NC TXD2 TXD1 74LVC1G74DC 10 kΩ EN Control 3.3V, at least 20mA when using 4xDISO Ref to Digital Isolator datasheet for more details SD RD Q SDA SCL Host μc PMBus R1 SGND The BCM380y475x800A31 bus converter provides accurate telemetry monitoring and reporting, threshold and warning limits adjustment, in addition to corresponding status flags. The BCM internal µC is referenced to primary ground. The Digital Isolator allows UART communication interface with the host Digital Supervisor at typical speed of 750 KHz across the isolation barrier. One of the advantages of the Digital Isolator is its low power consumption. Each transmission channel is able to draw its internal bias circuitry directly from the input signal being transmitted to the output with minimal to no signal distortion. The Digital Supervisor provides the host system µC with access to an array of up to 4 BCMs. This array is constantly polled for status by the Digital Supervisor. Direct communication to individual BCM is enabled by a page command. For example, the page (0x00) prior to a telemetry inquiry points to the Digital Supervisor data and pages (0x01 – 0x04) prior to a telemetry inquiry points to the array of BCMs connected data. The Digital Supervisor constantly polls the BCM data through the UART interface. The Digital Supervisor enables the PMBusTM compatible host interface with an operating bus speed of up to 400 kHz. The Digital Supervisor follows the PMBus command structure and specification. Please refer to the Digital Supervisor data sheet for more details. BCM® Bus Converter Rev 1.3 vicorpower.com Page 17 of 23 05/2015 800 927.9474 BCM380y475x800A31 Sine Amplitude Converter™ Point of Load Conversion ROUT 1.76 nH + RCIN 31.8 mΩ CIN VIN V IN – mΩ R35 OUT IOUT IOUT LIN_LEADS = 6.7 nH RCIN CIN 0.25 µF + + IIQQ 23.4 mA – RRC COUT OUT 138 mΩ V•I 1/8 • IOUT LOUT_LEADS = 1.3 nH + 1020 µΩ 1/8 • VIN COUT COUT 12.8 µF VOUT VOUT – K LIN_INT = 0.56 µH – Figure 16 — BCM module AC model The Sine Amplitude Converter (SAC™) uses a high frequency resonant tank to move energy from input to output. (The resonant tank is formed by Cr and leakage inductance Lr in the power transformer windings as shown in the BCM module Block Diagram). The resonant LC tank, operated at high frequency, is amplitude modulated as a function of input voltage and output current. A small amount of capacitance embedded in the input and output stages of the module is sufficient for full functionality and is key to achieving high power density. The BCM380y475x800A31 SAC can be simplified into the preceeding model. The use of DC voltage transformation provides additional interesting attributes. Assuming that ROUT = 0 Ω and IQ = 0 A, Eq. (3) now becomes Eq. (1) and is essentially load independent, resistor R is now placed in series with VIN. RRIN VIN Vin + – SAC™ SAC 1/8 KK==1/32 V OUT Vout At no load: VOUT = VIN • K (1) K represents the “turns ratio” of the SAC. Rearranging Eq (1): K= Figure 17 — K = 1/8 Sine Amplitude Converter with series input resistor The relationship between VIN and VOUT becomes: VOUT VIN (2) VOUT = (VIN – IIN • RIN) • K Substituting the simplified version of Eq. (4) (IQ is assumed = 0 A) into Eq. (5) yields: In the presence of load, VOUT is represented by: VOUT = VIN • K – IOUT • ROUT (3) VOUT = VIN • K – IOUT • RIN • K2 and IOUT is represented by: IOUT = (5) IIN – IQ K (4) ROUT represents the impedance of the SAC, and is a function of the RDSON of the input and output MOSFETs and the winding resistance of the power transformer. IQ represents the quiescent current of the SAC control, gate drive circuitry, and core losses. BCM® Bus Converter Rev 1.3 vicorpower.com Page 18 of 23 05/2015 800 927.9474 (6) BCM380y475x800A31 This is similar in form to Eq. (3), where ROUT is used to represent the characteristic impedance of the SAC™. However, in this case a real R on the input side of the SAC is effectively scaled by K2 with respect to the output. Assuming that R = 1 Ω, the effective R as seen from the secondary side is 15.6 mΩ, with K = 1/8 . A similar exercise should be performed with the addition of a capacitor or shunt impedance at the input to the SAC. A switch in series with VIN is added to the circuit. This is depicted in Figure 18. A solution for keeping the impedance of the SAC low involves switching at a high frequency. This enables small magnetic components because magnetizing currents remain low. Small magnetics mean small path lengths for turns. Use of low loss core material at high frequencies also reduces core losses. SS VVin IN + – Low impedance is a key requirement for powering a high-current, lowvoltage load efficiently. A switching regulation stage should have minimal impedance while simultaneously providing appropriate filtering for any switched current. The use of a SAC between the regulation stage and the point of load provides a dual benefit of scaling down series impedance leading back to the source and scaling up shunt capacitance or energy storage as a function of its K factor squared. However, the benefits are not useful if the series impedance of the SAC is too high. The impedance of the SAC must be low, i.e. well beyond the crossover frequency of the system. C C SAC™ SAC K = 1/8 K = 1/32 VVout OUT The two main terms of power loss in the BCM module are: n No load power dissipation (PNL): defined as the power used to power up the module with an enabled powertrain at no load. n Resistive loss (ROUT): refers to the power loss across the BCM® module modeled as pure resistive impedance. Figure 18 — Sine Amplitude Converter with input capacitor PDISSIPATED = PNL + PROUT A change in VIN with the switch closed would result in a change in capacitor current according to the following equation: IC(t) = C dVIN dt Therefore, (7) Assume that with the capacitor charged to VIN, the switch is opened and the capacitor is discharged through the idealized SAC. In this case, IC= IOUT • K (10) (8) POUT = PIN – PDISSIPATED = PIN – PNL – PROUT The above relations can be combined to calculate the overall module efficiency: h = POUT = PIN – PNL – PROUT PIN PIN substituting Eq. (1) and (8) into Eq. (7) reveals: IOUT C • dVOUT = K2 dt (9) The equation in terms of the output has yielded a K2 scaling factor for C, specified in the denominator of the equation. A K factor less than unity results in an effectively larger capacitance on the output when expressed in terms of the input. With a K = 1/8 as shown in Figure 18, C=1 μF would appear as C = 64 μF when viewed from the output. (11) = VIN • IIN – PNL – (IOUT)2 • ROUT VIN • IIN = 1– ( ) PNL + (IOUT)2 • ROUT VIN • IIN BCM® Bus Converter Rev 1.3 vicorpower.com Page 19 of 23 05/2015 800 927.9474 (12) BCM380y475x800A31 Input and Output Filter Design Thermal Considerations A major advantage of SAC™ systems versus conventional PWM converters is that the transformer based SAC does not require external filtering to function properly. The resonant LC tank, operated at extreme high frequency, is amplitude modulated as a function of input voltage and output current and efficiently transfers charge through the isolation transformer. A small amount of capacitance embedded in the input and output stages of the module is sufficient for full functionality and is key to achieving power density. The ChiP package provides a high degree of flexibility in that it presents three pathways to remove heat from internal power dissipating components. Heat may be removed from the top surface, the bottom surface and the leads. The extent to which these three surfaces are cooled is a key component for determining the maximum power that is available from a ChiP, as can be seen from Figure 1. This paradigm shift requires system design to carefully evaluate external filters in order to: n Guarantee low source impedance: To take full advantage of the BCM module’s dynamic response, the impedance presented to its input terminals must be low from DC to approximately 5 MHz. The connection of the bus converter module to its power source should be implemented with minimal distribution inductance. If the interconnect inductance exceeds 100 nH, the input should be bypassed with a RC damper to retain low source impedance and stable operation. With an interconnect inductance of 200 nH, the RC damper may be as high as 1 μF in series with 0.3 Ω. A single electrolytic or equivalent low-Q capacitor may be used in place of the series RC bypass. Since the ChiP has a maximum internal temperature rating, it is necessary to estimate this internal temperature based on a real thermal solution. Given that there are three pathways to remove heat from the ChiP, it is helpful to simplify the thermal solution into a roughly equivalent circuit where power dissipation is modeled as a current source, isothermal surface temperatures are represented as voltage sources and the thermal resistances are represented as resistors. Figure 19 shows the “thermal circuit” for a VI Chip® BCM module 6123 in an application where the top, bottom, and leads are cooled. In this case, the BCM power dissipation is PDTOTAL and the three surface temperatures are represented as TCASE_TOP, TCASE_BOTTOM, and TLEADS. This thermal system can now be very easily analyzed using a SPICE simulator with simple resistors, voltage sources, and a current source. The results of the simulation would provide an estimate of heat flow through the various pathways as well as internal temperature. Thermal Resistance Top n Further reduce input and/or output voltage ripple without sacrificing dynamic response: Given the wide bandwidth of the module, the source response is generally the limiting factor in the overall system response. Anomalies in the response of the source will appear at the output of the module multiplied by its K factor. n Protect the module from overvoltage transients imposed by the system that would exceed maximum ratings and induce stresses: The module input/output voltage ranges shall not be exceeded. An internal overvoltage lockout function prevents operation outside of the normal operating input range. Even when disabled, the powertrain is exposed to the applied voltage and power MOSFETs must withstand it. Total load capacitance at the output of the BCM module shall not exceed the specified maximum. Owing to the wide bandwidth and low output impedance of the module, low-frequency bypass capacitance and significant energy storage may be more densely and efficiently provided by adding capacitance at the input of the module. At frequencies
BCM380P475T800A31 价格&库存

很抱歉,暂时无法提供与“BCM380P475T800A31”相匹配的价格&库存,您可以联系我们找货

免费人工找货