12 1-800-735-6200
VI-J00 MiniMod
DC-DC Converters 25 to 100 Watts
Features
s s s s s s s s s s Up to 50W/Cubic Inch UL, CSA, TÜV, VDE, BABT CE Marked Up to 90% Efficiency Size: 2.28" x 2.4" x 0.5" (57,9 x 61,0 x 12,7) Remote Sense and Current Limit Logic Disable Wide Range Output Adjust ZCS Power Architecture Low Noise FM Control Nominal
0= 1= W= 2= 3= N= 4= T= 5= 6= 7=
Rev 3 1 of 2
Converter Selection Chart
VI-J
Input Voltage Range Brownout / Transient*
22V 36V n/a 60V 72V n/a 110V n/a 215V 425V n/a 12V 10 - 20V(5) n/a 24V 21 - 32V(2) 18V 24V 18 - 36V(2) n/a 36V 21 - 56V(6) 18V 48V 42 - 60V(3) 36V 48V 36 - 76V(2) n/a 72V 55 - 100V(2) 45V 110V 66 - 160V(2) n/a 150V 100 - 200V(2) 85V 300V 200 - 400V(3) 170V 150/300V 100 - 375V(6) 90V
Output Voltage
Z= 2V Y = 3.3V 0= 5V X = 5.2V W = 5.5V V = 5.8V T = 6.5V R = 7.5V M = 10V 1 = 12V P = 13.8V 2 N 3 L J K 4 H F D B = 15V = 18.5V = 24V = 28V = 36V = 40V = 48V = 52V = 72V = 85V = 95V
Product Highlights
The VI-J00 MiniMod family establishes a new standard in component-level DC-DC converters. This “junior” size complement to the higher power VI-200 family offers up to 100W of isolated and regulated power in a board mounted package. At one-half the size and twice the power density of previous 100W modules, and with a maximum operating temperature rating of 100˚C, the MiniMod opens new horizons for board-mounted (distributed) power architectures. Utilizing Vicor’s “zero-currentswitching” forward converter technology, proven by an installed base of over 8 million units, the MiniMod family combines state of the art power density with the efficiency, low noise and reliability required by next generation power systems.
Product Grade/ Operating Temp.
E= C= I= M= -10°C -25°C -40°C -55°C to to to to +100°C +100°C +100°C +100°C
Product Grade/ Storage Temp.
E C I M = = = = -20°C -40°C -55°C -65°C to +105°C to +105°C to +105°C to +105°C
Output Power/Current
VOUT ≥ 5V Z = 25W Y = 50W X = 75W W = 100W Z Y X W VOUT < 5V = 5A = 10A = 15A = 20A
Max. Output For 5V Outputs > 5V Outputs < 5V Outputs (1) 50W 50W 10A (2) 75W 100W 20A (3) 100W 100W 20A
*Brownout 75% of rated load; transient voltage for 1 second.
Max. Output For 5V Outputs > 5V Outputs < 5V Outputs (4) 75W 75W 15A (5) 50W 75W 15A (6) 50W 75W 10A
Mechanical Drawing
.49 (12,4)
.30±.015 (7,6)±(0,38)
.65 (16,5)
2.28 (57,9) 1.30 (33,0)
.080 Dia (2) places Solder plate over copper alloy
Pin # 1 4 3 2.10 (53,4) 2 9 8 2 3 1.40 1.00 (35,6) .70 (25,4) .40 (17,8) (10,2) .35± .015 (8,9)±(0,38) 4 5 6 7 8 9 .15 (3,8) FULL R .15 (3,8) .040 (1,0) Dia (7) places Solder plate over copper alloy Product ID this surface .22 (5,6) Min. .30 (7,6) Min.
Function +In Gate In Gate Out -In +Out +Sense Trim –Sense –Out
VI-J00
7 6 5
Packaging Options
SlimMods™, high power density, flangeless packages and FinMods™, featuring integral finned heatsinks. SlimMod: Option suffix: - S Example: VI - JXX - XX - S FinMod: Option suffix: - F1 and - F2 Examples: VI - JXX - XX -F1, 0.75" height VI - JXX - XX -F2, 1.00" height
.12 (3,0)
1
2.40 (61,0) 1.75 (44,4) Max.
1.90 (48,3)
.50 (12,7)
+.030 (0,76) -.000 (0)
.01 Aluminum Base
For the latest Vicor Product Information: www.vicorpower.com
12 1-800-735-6200
Converter Specifications
(typical at TBP = 25°C, nominal line and 75% load, unless otherwise specified)
VI-J00 E-Grade PARAMETER
s Input Characteristics Inrush charge Input reflected ripple current – pp Input ripple rejection
Rev 3 2 of 2
VI-J00 C-, I-, M-Grade MIN. TYP. MAX. UNITS TEST CONDITIONS
MIN.
TYP.
MAX.
60x10 -6 10% 25+20Log
60x10 -6 10%
100x10-6
Coulombs IIN dB dB
Nominal line Nominal line, full load 120 Hz, nominal line 2400 Hz, nominal line
()
Vin Vout 2
30+20Log Vin Vout 20+20Log Vin Vout 1.35
() ()
2 1.0% 0.2% 0.5% 0.02
No load power dissipation s Output Characteristics Setpoint accuracy Load/line regulation Load/line regulation Output temperature drift Long term drift Output ripple - pp: 2V, 3.3V 5V 10-48V Trim range1 Total remote sense compensation Current limit Short circuit current s Control Pin Characteristics Gate out impedance Gate in impedance Gate in high threshold Gate in low threshold Gate in low current s Dielectric Withstand Characteristics Input to output Output to baseplate Input to baseplate s Thermal Characteristics Efficiency Baseplate to sink s Mechanical Specifications Weight
110V,
1.35
Watts
1.0%
2.0% 0.5% 1.0%
0.5% 0.05% 0.2% 0.01 0.02 100 2% 0.75%
VNOM VNOM VNOM %/°C %/1K hours mV
LL to HL, 10% to Full Load LL to HL, No Load to 10% Over rated temperature
0.02 0.02 200 5% 3% 50% 0.5 105% 105% 110% 135% 140% 50% 0.5 105% 105%
150 3% 1.5% 110% 125% 130%
20 MHz bandwidth 20 MHz bandwidth 20 MHz bandwidth 0.25V max. neg. leg Automatic restart
VNOM Volts INOM INOM
50 10 3 6 0.65 6 0.65
50 10 3 6 6
Ohms Ohms Volts Volts mA
Use open collector
3,000 500 1,500
3,000 500 1,500
VRMS VRMS VRMS
Baseplate earthed
78-88% 0.4
80-90% 0.4
°C/Watt
With Vicor P/N 04308
3.0 (85)
3.0 (85)
Ounces (Grams)
12V and 15V outputs, standard trim range ±10%. Consult factory for wider trim range.
For product compliance with agency standards please refer to pages 67 - 69.
For the latest Vicor Product Information: www.vicorpower.com
73