0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
VEH40US15

VEH40US15

  • 厂商:

    XPPOWER

  • 封装:

    -

  • 描述:

    AC/DC DESKTOP ADAPTER 15V 40W

  • 数据手册
  • 价格&库存
VEH40US15 数据手册
ACDC 20/40 Watts VEH Series xppower.com • Energy Efficiency Level V • CEC 2008 and EISA 2007 Compliant • Optional Inlet Connectors • Class II Versions • +60 °C Operating Temperature • Compact Dimensions • Low Cost B R A N D Specification Input • 90-264 VAC • 47-63 Hz • 0.5 A max VEH20 1.0 A max VEH40 Inrush Current • 45 A/90 A for 115 VAC/230 VAC, cold start at 25 °C Earth Leakage Current • 0.75 mA at 240 VAC/50 Hz Power Factor • EN61000-3-2, Class A Input Protection • Internal fuse fitted in line VEH20: T1 A, 250 V VEH40: T3.15 A, 250 V No Load Input Power • 250 kHrs to MIL-HDBK-217F at 25 °C,GB Environmental Operating Temperature • 0 °C to +60 °C, derate from 100% power at +40 °C to 50% power at +60 °C Storage Temperature • -40 °C to +85 °C Cooling • Convection-cooled Operating Humidity • 5-95% RH, non-condensing Operating Altitude • 2000 m Shock • 10 g, 10 ms on 3 axes EMC & Safety Emissions Harmonic Current Voltage Flicker ESD Immunity Radiated Immunity EFT/Burst Surge • • • • • • • Conducted Immunity Magnetic Field Dips & Interruptions • • • Safety Approvals • EN55022 level B conducted & radiated EN61000-3-2 class A EN61000-3-3 EN61000-4-2 level 3 Perf criteria A EN61000-4-3 3 V/m Perf criteria A EN61000-4-4 level 2 Perf criteria A EN61000-4-5 installation class 3 Perf criteria A EN61000-4-6 level 2 Perf criteria A EN61000-4-8 1 A/m Perf criteria A EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms Perf Criteria A, B, B EN60950-1, UL/cUL60950-1, Approved as Limited Power Source Max Output Power 15 20 20 20 20 20 25 40 40 40 40 40 Output Voltage(1) W W W W W W W W W W W W 5.0 12.0 15.0 18.0 24.0 48.0 5.0 12.0 15.0 18.0 24.0 48.0 Output Current VDC VDC VDC VDC VDC VDC VDC VDC VDC VDC VDC VDC 3.00 1.67 1.33 1.11 0.83 0.42 5.00 3.33 2.67 2.22 1.67 0.83 A A A A A A A A A A A A Total Regulation(2) 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% Model Number VEH20US05(3,4) VEH20US12(3,4) VEH20US15(3,4) VEH20US18(3,4) VEH20US24(3,4) VEH20US48(3,4) VEH40US05 VEH40US12 VEH40US15 VEH40US18 VEH40US24 VEH40US48 Notes 1. 2. 3. 4. Other output voltages available, contact sales for details Total regulation includes line regulation and load regulation. Standard input connector is IEC320-C14 inlet. For optional IEC320-C6 inlet add suffix ‘C6’ to model number, e.g. VEH20US12C6. For optional class II version with IEC320-C8 inlet add suffix ’C2’ to model number e.g. VEH20US12C2 Mechanical Details VEH20 1.22 (31.0) 1.22 (31.0) 0.02 (0.5) 0.02 (0.5) 3.90 (99.0) For C8 and C6 inlet versions 4.11 (104.0) for C14 inlet versions 1.22 (31.0) 1.65 (42.0) 0.02 (0.5) AC INPUT IEC-320-C14 INLET AC INPUT IEC320-C8 INLET (Optional C2 Version) AC INPUT IEC320-C6 INLET (Optional C6 Version) VEH40 4.21 (107.0) 1.19 (30.1) 1.85 (47.0) 0.02 (0.5) AC INPUT IEC320-C14 INLET Notes 1. 2. 3. 4. 5. 6. 7. All dimensions are shown in inches (mm). Tolerance ±0.04 (±1.0) max. Weight: 0.37 lbs (170 g) for VEH20, 0.62 lbs (280 g) for VEH40 Output connector: is 0.22 (5.5) outer diameter barrel, 0.10 (2.5) inner diameter barrel with center positive (+) and outer shell negative (-). Length is 0.433 (11.0). Output cable length is 48” (1220mm) approx. For European mains lead order part: EU-MAINS-IEC, for IEC320-C14 inlet, EU-MAINS-C5 for IEC320-C6 inlet, EU-MAINS-8 for Class II For UK mains lead order part: UK-MAINS-IEC, for IEC320-C14 inlet, UK-MAINS-C5 for IEC320-C6 inlet, UK-MAINS-8 for Class II For US mains lead order part: US-MAINS-IEC, for IEC320-C14 inlet, US-MAINS-C5 for IEC320-C6 inlet, US-MAINS-8 for Class II 02-May-14 ACDC VEH20/40 Models and Ratings
VEH40US15 价格&库存

很抱歉,暂时无法提供与“VEH40US15”相匹配的价格&库存,您可以联系我们找货

免费人工找货