0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
XAN.M13.GLA.6G

XAN.M13.GLA.6G

  • 厂商:

    LEMO(雷莫)

  • 封装:

    -

  • 描述:

    CONN PLUG MALE 13P GOLD SLDR CUP

  • 数据手册
  • 价格&库存
XAN.M13.GLA.6G 数据手册
PLASTIC CONNECTORS ® ® Precision modular connectors to suit your application Since its creation in Switzerland in 1946 the LEMO Group has been recognized as a global leader of circular Push-Pull connectors and connector solutions. Today LEMO and its affiliated companies, REDEL and COELVER, are active in more than 80 countries with the help of over 40 subsidiaries and distributors. Over 5’000 REDEL connectors The modular design of the REDEL range provides over 5’000 connectors from ø 14 mm to ø 21 mm, capable of handling cable diameters up to 9.5 mm and up to 32 contacts. This vast portfolio enables you to select the ideal connector configuration to suit almost any specific requirement in most markets, including medical devices, test and measurement instruments, machinery, audio video broadcast, telecommunications and military. REDEL’s Push-Pull Self-Latching Connection System This self-latching system is renowned worldwide for its easy and quick mating and unmating features. It provides absolute security against vibration, shock or pull on the cable, and facilitates operation in a very limited space. Fv 7 N The REDEL self-latching system allows the connector to be mated by simply pushing the plug axially into the socket. Fv: average latching force (without contact) Fa 110 N Once firmly latched, connection cannot be broken by pulling on the cable or any other component part other than the outer release sleeve. Fa: average retention force (without contact) Fd 9 N When required, the connector is disengaged by a single axial pull on the outer release sleeve. This first disengages the latches and then withdraws the plug from the socket. Fd: average unmating force (without contact) UL Recognition ® REDEL connectors are recognized by the Underwriters Laboratories (UL). The approval of the complete system (REDEL connector, cable and your equipment) will be easier because REDEL connectors are approved. CE Marking CE marking means that the appliance or equipment bearing it complies with the protection requirements of one or several European safety directives. CE marking applies to complete products or equipment, but not to electromechanical components, such as connectors. RoHS REDEL connector specifications exceed the requirements of the RoHS directives (2002/95/EC) of the European Parliament and the latest amendments. This directive specifies the restrictions of the use of hazardous substances in electrical and electronic equipment marketed in Europe. LEMO guarantees that its connectors are free of mercury, cadmium, lead, hexavalent chromium and polybromide biphenyl (PBB), polybromide diphenyl ether (PBDE), or DecaBDE. Cover picture: PET-IRM scanner installed in Hôpitaux Universitaires de Genève (Switzerland). www.lemo.com Exploded view of the REDEL XP Straight plug backnut insulator + contacts cable collet shell Straight plug with bend relief bend relief backnut for a bend relief shell insulator + contacts cable collet Fixed socket collet nut notched nut insulator + contacts shell front nut Free socket backnut www.lemo.com cable collet insulator + contacts shell 1 XP Series The REDEL XP connectors are plastic Push-Pull connectors. These circular plastic connectors are especially adapted for applications such as medical electronics and test & measurement. The XP series offer additional features: the latch sleeve is recessed into the connector body ensuring greater shock resistance of the product. The complete connector can be assembled from spare parts (even the contact configuration) therefore offering good flexibility in stock keeping. The outer shell in Proprietary sulfone enables extensive sterilisation cycles of the product. A large choice of bend relief is available in different colour and size. REDEL XP series connectors are not compatible with the REDEL 1P or 2P series. Features & Benefits – Plastic shell made of Proprietary sulfone – Blind mating, scoop proof – Extended resistance to sterilisation – Enhanced ergonomics «hand grip» – Increased resistance to shock – New patented Push-Pull system – UL recognized (file E119802) Applications – Medical electronics – Test & measurement – Industrial electronics Standard models Straight plugs Fixed sockets XA● XL● XA● XK● Free sockets XR● XR● XK● 2 www.lemo.com Part numbering system X Plug X A N . M 1 3 . G L A . 6 G .M . . Variant Z = cable collet and nut for fitting a bend relief Collet nut colour table: (page 7) Model: (pages 4-5) G = grey A = blue J = yellow Keying: (page 6) Contact configuration (page 6) Collet: 3 = (cable ø 2.5 mm - 3.9 mm) 5 = (cable ø 4.0 mm - 5.2 mm) 6 = (cable ø 5.3 mm - 6.5 mm) 7 = (cable ø 6.6 mm - 7.5 mm) Number of contacts: (page 6) Outershell colour: G = grey N = black B = white Contact type: (page 7) Insulator: L = PEEK A = male to solder C = male to crimp Free socket N = black R = red V = green B = white X R N . M 1 3 . G L L . 6 G L = female to solder 1) M = female to crimp 1) Variant Z = cable collet and nut for fitting a bend relief Collet nut colour table: (page 7) Model: (pages 4-5) G = grey A = blue J = yellow Keying: (page 6) Contact configuration (page 6) Collet: 3 = (cable ø 2.5 mm - 3.9 mm) 5 = (cable ø 4.0 mm - 5.2 mm) 6 = (cable ø 5.3 mm - 6.5 mm) 7 = (cable ø 6.6 mm - 7.5 mm) Number of contacts: (page 6) Outershell colour: G = grey N = black B = white Contact type: (page 7) Insulator: L = PEEK A = male to solder 1) C = male to crimp 1) Fixed socket N = black R = red V = green B = white X K N . M 1 3 . G L L = female to solder M = female to crimp L G Front nut colour table: (page 7) Model: (pages 4-5) Keying: (page 6) Contact configuration (page 6) Number of contacts: (page 6) Outershell colour: G = grey N = black B = white G = grey A = blue J = yellow N = black R = red V = green B = white Contact type: (page 7) C = male to crimp 1) A = male to solder 1) D = male to print 1) L = female to solder M= female to crimp N = female to print V = female 90° for print Insulator: L = PEEK XAN.M13.GLA.6G Straight plug with cable collet and alignment key (N), multipole type with 13 male contacts to solder, grey Proprietary sulfone shell, PEEK insulator, collet for max cable ø 6.5 mm and grey collet nut. XRN.M13.GLL.6G Free socket with cable collet and alignment key (N), multipole type with 13 female contacts to solder, grey Proprietary sulfone shell, PEEK insulator, collet for max cable ø 6.5 mm and grey collet nut. XKN.M13.GLLG Fixed socket with two nuts and alignment key (N), multipole type with 13 female contacts to solder, grey Proprietary sulfone shell, PEEK insulator and grey plastic front nut. Note: 1) contacts delivered only with S or T keying (inverted contacts). www.lemo.com 3 Standard models (IP50) .M X Fixed socket . Straight plug 6 2 4 3 5 5 1 4 2 1 6 3 1 Outershell 1 Outershell 2 Insulator 2 latch sleeve 3 Female contact 3 Backnut 4 Notched nut 4 Insulator 5 Front nut 5 Contact 6 Collet nut 6 Cable collet Value Standards Average retention force when pulling on the cable 1N = 0.102 kg 110 IEC 60512-8 test 15f Cable retention force (depends on cable construction) 1N = 0.102 kg ~130 Characteristics XAN . Characteristics Endurance (latching) Working temperature range (Proprietary sulfone) Value Standards > 1000 cycles IEC 60512-5 test 9a -50/+170°C – IEC 60512-9 test 17c Straight plug, key (N) or keys (P, S and T), with cable collet Part Number XAN.M••.GLA.3G XAN.M••.GLA.5G XAN.M••.GLA.6G XAN.M••.GLA.7G Cable ø min max 2.5 4.0 5.3 6.6 3.9 5.2 6.5 7.5 Note: replace •.• by contact configuration (see page 6). ø 16.5 ~46 XAN Straight plug, key (N) or keys (P, S and T), with cable collet and nut for fitting a bend relief Part Number XAN.M••.GLA.3GZ XAN.M••.GLA.5GZ XAN.M••.GLA.6GZ XAN.M••.GLA.7GZ Cable ø min max 2.5 4.0 5.3 6.6 3.9 5.2 6.5 7.5 Note: replace •.• by contact configuration (see page 6). The bend relief must be ordered separately (see page 10). ø 16.5 ~48.0 XLN Fixed socket, key (N) or keys (P, S and T), nut fixing a Part Number 23.5 5.2 XLN.M••.GLLG Contact Solder Crimp a max (mm) a (mm) 2.2 0 ø 18.5 M14 x 1 Note: replace •.• by contact configuration (see page 6). S12.5 7.5 maxi Note: all dimensions are in millimeters. 4 www.lemo.com X XKN .M . . Fixed socket, key (N) or keys (P, S and T) with two nuts (back panel mounting) a Part Number 23.5 3 4 Contact Solder Crimp a max (mm) a (mm) XKN.M••.GLLG ø 18.5 M14 x 1 Fixed socket, key (N) or keys (P, S and T) with two nuts (back panel mounting) and with straight print contact a Part Number 23.5 3 4 Contact Solder Crimp a max (mm) a (mm) XKN.M••.GLNG 4.1 0 ø 18.5 M14 x 1 Note: replace •.• by contact configuration (see page 6). S12.5 XRN 0 8.5 maxi S12.5 XKN 2.2 Note: replace •.• by contact configuration (see page 6). 8.5 maxi Free socket, key (N) or keys (P, S and T), with cable collet Part Number XRN.M••.GLL.3G XRN.M••.GLL.5G XRN.M••.GLL.6G XRN.M••.GLL.7G Cable ø min max 2.5 4.0 5.3 6.6 3.9 5.2 6.5 7.5 Note: replace •.• by contact configuration (see page 6). ø 15.7 ~44.7 XRN Free socket, key (N) or keys (P, S and T), with cable collet and nut for fitting a bend relief Part Number XRN.M••.GLL.3GZ XRN.M••.GLL.5GZ XRN.M••.GLL.6GZ XRN.M••.GLL.7GZ Cable ø min max 2.5 4.0 5.3 6.6 3.9 5.2 6.5 7.5 Note: replace •.• by contact configuration (see page 6). The bend relief must be ordered separately (see page 10). ø 15.7 ~46.7 Note: all dimensions are in millimeters. www.lemo.com 5 Alignment key X .M . . . . Verify the third digit of the part number in order to select the right keying. The standard keying is «N» coded. 0 0 0 0 30° 60° 50° 90° N P S male female male female Keying (plug front view) Reference Contact type for plug Contact type for socket T female male female male Insert configuration Contact type Female solder contacts Air clearance min 2) (mm) Creepage distance min 3) (mm) Rated current (A) Test voltage (kV rms)1) Contact-contact Air clearance min 2) (mm) Creepage distance min 3) (mm) Rated current (A) Female crimp contacts Test voltage (kV rms)1) Contact-contact 3 Print (elbow) 4 Solder / Crimp / Print (straight) 1 M04 4 1.3 1.10 1.40 184) 20 22 • • 1.60 0.95 11.5 1.80 1.35 11.5 M06 6 0.9 0.80 1.10 20 22 24 • • 1.50 0.95 8.5 1.90 1.35 8.5 M08 8 0.9 0.80 1.10 20 22 24 • • 1.50 0.75 5.0 1.50 1.1 5.0 M10 10 0.7 0.80 0.80 22 4) 24 26 • • 1.16 0.70 4.2 1.53 1.1 4.2 M13 13 0.7 0.80 0.80 22 4) 24 26 • • 1.05 0.50 4.0 1.30 0.9 4.0 M16 16 0.5 0.45 0.45 28 30 32 • – 0.75 0.45 3.0 1.35 0.8 3.0 M18 18 0.5 0.45 0.45 28 30 32 • – 0.74 0.47 2.5 1.16 0.8 2.5 M22 22 0.5 0.45 0.45 28 30 32 • – 0.60 0.40 2.0 1.30 0.8 2.0 AWG max-min 6 Crimp bucket ø (mm) 4) 4 Solder bucket ø (mm) 4) 3 Crimp Contact ø A (mm) 6 Solder Number of contacts Multipole Male crimp contacts 1 .M Reference øA øA Male solder contacts X Note: 1) depending on specific application and related standard, more restrictive operating voltage may apply. We suggest operating voltage = 1/3 test voltage, see page 15. 2) shortest distance in air between two conductive parts. 3) shortest distance along the surface of the insulating material between two conductive parts. 4) for a given AWG, the diameter of some stranded conductor design is larger than the solder cup diameter (see page 14). 6 www.lemo.com Outer shell material Proprietary sulfone Ref. Material X Colour Temperature G N B Grey Black White -50° / +170°C .M . . .M . . Note: adapted for sterilisation satured steam (120°C or 134°C). Contact type X Select the type of contact: solder or crimp? When should I use crimp rather than solder contacts ? Plug Soldering • recommended for small volumes • requires little amount of tooling (soldering iron) • requires more time Socket Type solder crimp Male Female A C L1) M1) Type solder crimp print print 90° Male Female A1) D1) - L M N V Crimping • recommended for large volumes • no heat is required to make the connection • for contacts with high density • for use in high temperature environment (max. 170°C) • requires extra tooling (crimping tools) Note: 1) only for S or T keying. Colour coding Reference RAL code grey G 7001 blue A 5015 X yellow J 1016 Colours black N 9005 red R 3020 green V 6019 white B 9003 .M . . Note: the RAL colours are indicative and depend on raw material and production process. Colour may differ. Easy identification with the assistance of colour coding. Outershell is only available in grey, black or white. www.lemo.com 7 Accessories XAN / XLN Insulator and male or female crimp contacts Contact nb. of configuration contacts ø contact (mm) Kit contact part number Male male / black marking XAN / XLN M04 M06 M08 M10 M13 M16 M18 M22 female / black marking 4 6 8 10 13 16 18 22 1.3 0.9 0.9 0.7 0.7 0.5 0.5 0.5 XAN.M04.ZLC XAN.M06.ZLC XAN.M08.ZLC XAN.M10.ZLC XAN.M13.ZLC XAN.M16.ZLC XAN.M18.ZLC XAN.M22.ZLC Female XLN.M04.ZLM XLN.M06.ZLM XLN.M08.ZLM XLN.M10.ZLM XLN.M13.ZLM XLN.M16.ZLM XLN.M18.ZLM XLN.M22.ZLM Insulator with male or female solder contacts Contact nb. of configuration contacts ø contact (mm) Kit contact part number Male male / black marking XAl.100.lZZ Kit contact part number female / black marking M04 M06 M08 M10 M13 M16 M18 M22 4 6 8 10 13 16 18 22 1.3 0.9 0.9 0.7 0.7 0.5 0.5 0.5 XAN.M04.ZLA XAN.M06.ZLA XAN.M08.ZLA XAN.M10.ZLA XAN.M13.ZLA XAN.M16.ZLA XAN.M18.ZLA XAN.M22.ZLA Kit contact part number Female XLN.M04.ZLL XLN.M06.ZLL XLN.M08.ZLL XLN.M10.ZLL XLN.M13.ZLL XLN.M16.ZLL XLN.M18.ZLL XLN.M22.ZLL Plug outershell kit (no contacts) Part Number Colours ~36 XA•.100.GZZ XA•.100.BZZ XA•.100.NZZ grey white black Note: replace • by alignment key (N, P, S or T). XRl.200.ll Free socket outershell kit (no contacts) Part Number ~35 XR•.200.RG XR•.200.RB XR•.200.RN Colours grey white black Note: replace • by alignment key (N, P, S or T). XLl.200.lZZl Socket outershell kit (nut fixing), (no contacts) Part Number Colours ø 18.5 23.5 8 XL•.200.GZZG XL•.200.BZZB XL•.200.NZZN grey white black Note: replace • by alignment key (N, P, S or T). www.lemo.com XKl.200.lZZl Socket outershell kit (with two nuts), (no contacts) Part Number Colours 23.5 ø 18.5 XK•.200.GZZG XK•.200.BZZB XK•.200.NZZN XAN Note: replace • by alignment key (N, P, S or T). Collet Part Number 21.5 XAN.739.RG XAN.752.RG XAN.765.RG XAN.775.RG max ø 9.8 XAM.130.ll Cable ø (mm) min. max. 2.5 4.0 5.3 6.6 3.9 5.2 6.5 7.5 Nut for fitting a GMA.1B bend relief Part Number ø 10 ø 12.5 20.3 XLN grey white black XAM.130.RG XAM.130.RB XAM.130.RN Colours grey white black Note: only for XA•, XR• models. Notched nut Part Number 18.5 M14 x 1 4 XLN.240.RG Colours grey Note: all dimensions are in millimeters. XLN Collet nut M11 x 0.75 Part Number 4.5 XLN.230.RG Colours grey 12.5 XLN Plastic front nut for XLl models Part Number 18.5 M14 x 1 www.lemo.com 5.2 XLN.220.RG XLN.220.RB XLN.220.RR XLN.220.RN XLN.220.RJ XLN.220.RA XLN.220.RV Colours grey white red black yellow blue green 9 XKN Plastic front nut for XKl models Part Number 18.5 M14 x 1 GMA.1B XKN.220.RG XKN.220.RB XKN.220.RR XKN.220.RN XKN.220.RJ XKN.220.RA XKN.220.RV 4 Colours grey white red black yellow blue green Bend relief A bend relief absorbs the angular force that may be exerted on cables. These are designed for plugs and free sockets with cable collet and nut. The Colours of these bend reliefs are not identical to the RAL coulours of the socket’s front nut. øA L Part Number Dimensions (mm) Bend relief Cable ø A L max. min. GMA.1B.025.DG GMA.1B.030.DG GMA.1B.035.DG GMA.1B.040.DG GMA.1B.045.DG GMA.1B.054.DG GMA.1B.065.DG 2.5 3.0 3.5 4.0 4.5 5.4 6.5 30 30 30 30 30 30 30 2.9 3.4 3.9 4.4 4.9 6.0 7.0 2.5 3.0 3.5 4.0 4.5 5.4 6.5 GMA.1B.025.RG GMA.1B.030.RG GMA.1B.035.RG GMA.1B.040.RG GMA.1B.045.RG GMA.1B.051.RG GMA.1B.057.RG GMA.1B.063.RG 2.5 3.0 3.5 4.0 4.5 5.1 5.7 6.3 34 34 34 34 34 34 34 34 2.9 3.4 3.9 4.4 5.0 5.6 6.2 7.0 2.5 3.0 3.5 4.0 4.5 5.1 5.7 6.3 Temperature range Material Desmopan 786 Polyurethane elastomer Silicone elastomer VMQ in dry atmosphere in water steam -40°C, +80°C – -60°C, +200°C +140°C Reference Colours A B G J M N R S V blue white grey yellow brown black red orange green Note: the selection of pigments, which should remain stable at high temperature, is limited by the new regulations. For this reason, some colours will be a shade different from those used for Desmopan bend reliefs. The selected solutions represent the best possible compromise. Note: the last letter «G» of the part number indicates a grey colour, see the adjacent table and replace letter «G» by the letter of the colour required. All dimensions are in millimeters. 10 www.lemo.com Tooling XOP.019.HN Spanners with notch for securing the notched nut XOB.186.GN XOB.187.GN Spanners for nut XLN.220Rl Spanners for nut XKN.220Rl ø 20 76.7 30 28 Material: Black polyamide. For notched nut XLN.240.RG. Material: Black polyamide DPC.91.701.V XOE Crimping tool Positioners for crimp contacts male DCF female Automatic extraction tools for crimp contacts Configuration M04 M06/M08 M10/M13 M16/M18/M22 Contact ø (mm) Conductor AWG 1.3 0.9 0.7 0.5 18-20 20-22-24 22-24-26 28-30-32 Positioner part number Male contact Female contact XOE.130.VC XOE.090.VC XOE.070.VC XOE.050.VC XOE.130.VM XOE.090.VM XOE.070.VM XOE.050.VM Selector No Setting 6-5-5 6-5-5 6-5-5 4-3-3 Part number extractor Male contact DCF.93.131.4LT DCF.93.090.4LT DCF.93.070.4LT DCF.91.050.2LT1) Female contact DCF.93.131.4LT DCF.93.090.4LT DCF.93.070.4LT DCF.91.050.2LT1) Note: the variance in conductor stranding diameter for the minimum AWG is such that some can have a cross section which is not sufficient to guarantee crimping as per IEC 60352-2 standard. 1) With this extractor, the user must remove the insulator from the outer shell. All dimensions are in millimeters. www.lemo.com 11 Panel hole For XLl and XKl ø 14.0 + 0.1 0 12.6 ± 0.05 Note: Socket mounting nut torque = 1 Nm. All dimensions are in millimeters. 23.5 min. PCB drilling pattern + 0.1 0 + 0.1 0 1.5 0.65 1.5 M10 1.32 M08 M13 16 x ø 0.6 + 0.1 0 1.4 M16 1.4 18 x ø 0.6 1.6 1.7 0.65 M18 1.7 0.65 22 x ø 0.6 + 0.1 0 1.32 + 0.1 0 1.32 0.66 1.65 1.3 1.6 1.65 1.3 1.6 + 0.1 0 2.1 1.1 10 x ø 0.8 1.74 1.78 13 x ø 0.8 2.1 1.1 2.1 1.35 1.5 1.32 1.3 1.6 1.5 1.81 0.67 1.97 8 x ø 0.8 1.97 1.2 M06 0.87 2.1 2.65 1.2 0.66 + 0.1 0 1.6 6 x ø 0.8 M04 1.78 2.65 2.4 2.4 1.1 1.6 1.1 0.8 + 0.1 0 1.3 4 x ø 0.8 0.8 2.3 2.3 0.8 1.35 For straight contacts 1.81 0.67 M22 Note: all dimensions are in millimeters 12 www.lemo.com Assembly instructions Solder contacts / Crimp contacts ➀ ➁ ➂ ➄ ➅ ➆ 1. Slide the collet nut ➀ and then the collet ➁ onto the cable. L Configuration Dimensions (mm) Solder contacts Crimp contacts L T L T M04 M06, M08 M10, M13 11.5 13.0 13.0 3.5 3.0 3.0 15.0 15.0 15.0 3.5 3.5 3.5 M16 to M22 12.5 2.5 14.5 2.5 2. Strip the cable according to the lengths given in the table. Tin the conductors. T 3. Solder conductors into contacts, starting with the center contacts, making sure that neither solder nor flux gets onto the insulator or cable insulation. solder / crimp Fix the appropriate positioner in the crimping tool. Set selector to the number corresponding to the conductor AWG as indicated on the positioner label. Fit conductor into contact and make sure it is visible through the inspection hole in the crimp barrel. Slide conductor-contact combination into the open crimping tool; make sure that the contact is fully pushed into the positioner. Close the tool. Remove from crimping tool and check that conductor is secure in contact and shows in inspection hole. 4. Slide the collet ➁ forward and locate both tags ➂ in the slots ➄ on the insulator ➅. Push collet ➁ and insulator ➅ assembly into the shell ➆ whilst turning it to ensure that the tag ➂ locates in the inside slot of the shell. 5. Slide collet nut ➀ over collet ➁ and tighten the collet nut ➀ to the maximum torque of 0.3 Nm. – Socket mounting nut torque = 1 Nm. www.lemo.com 13 Technical tables Table of American Wire Gauge Construction AWG 0 1 2 4 6 8 8 10 10 10 12 12 12 1) 12 14 14 14 1) 14 16 1) 16 16 16 1) 16 18 1) 18 1) 18 18 18 18 20 1) 20 20 20 20 22 22 22 24 1) 24 24 24 26 26 26 28 1) 28 28 30 30 32 32 34 36 38 40 14 Table of wire gauges according to IEC-60228 standard ø wire max Wire section Strand nb AWG/ strand (mm) (in) (mm2) (sq in) 259 817 259 133 133 168 133 105 37 1 37 19 7 1 41 19 7 1 65 26 19 7 1 65 42 19 16 7 1 42 19 10 7 1 19 7 1 42 19 7 1 19 7 1 19 7 1 7 1 7 1 1 1 1 1 24 30 26 25 27 30 29 30 26 10 28 25 20 12 30 27 22 14 34 30 29 24 16 36 34 30 30 26 18 36 32 30 28 20 34 30 22 40 36 32 24 38 34 26 40 36 28 38 30 40 32 34 36 38 40 11.277 9.702 8.89 6.9596 5.5118 4.4450 4.3942 3.3020 2.9210 2.6162 2.3114 2.3622 2.5400 2.0828 2.0574 1.8542 2.0828 1.6510 1.5748 1.5748 1.4986 1.5494 1.3208 1.2700 1.2700 1.3208 1.2954 1.2700 1.0414 1.0160 1.0414 1.0160 0.9906 0.8382 0.8382 0.7874 0.6604 0.6604 0.6858 0.6350 0.5588 0.5588 0.5080 0.4318 0.4318 0.4064 0.3302 0.3302 0.2794 0.2794 0.2286 0.1693 0.127 0.1016 0.078 0.444 0.382 0.35 0.274 0.217 0.175 0.173 0.13 0.115 0.103 0.091 0.093 0.10 0.082 0.081 0.073 0.082 0.065 0.062 0.062 0.059 0.061 0.052 0.05 0.05 0.052 0.051 0.05 0.041 0.04 0.041 0.04 0.039 0.033 0.033 0.031 0.026 0.026 0.027 0.025 0.022 0.022 0.02 0.017 0.017 0.016 0.013 0.013 0.011 0.011 0.009 0.007 0.005 0.004 0.003 52.90 41.40 33.20 21.5925 13.5885 8.5127 8.6053 5.3204 4.7397 5.2614 2.9765 3.0847 3.6321 3.3081 2.0775 1.9413 2.2704 2.0820 1.3072 1.3174 1.2293 1.4330 1.3076 0.8234 0.8447 0.9627 0.8107 0.8967 0.8229 0.5320 0.6162 0.5067 0.5631 0.5189 0.3821 0.3547 0.3243 0.2045 0.2407 0.2270 0.2047 0.1540 0.1408 0.1281 0.0925 0.0887 0.0804 0.0568 0.0507 0.0341 0.0324 0.0201 0.0127 0.0081 0.0049 0.0820 0.0641 0.0514 0.0335 0.0211 0.0132 0.0133 0.0082 0.0073 0.0082 0.0046 0.0048 0.0056 0.0051 0.0032 0.0030 0.0035 0.0032 0.0020 0.0020 0.0019 0.0022 0.0020 0.0013 0.0013 0.0015 0.0013 0.0014 0.0013 8.2x10-4 0.0010 7.9x10-4 8.7x10-4 8.0x10-4 5.9x10-4 5.5x10-4 5.0x10-4 3.2x10-4 3.7x10-4 3.5x10-4 3.2x10-4 2.4x10-4 2.2x10-4 2.0x10-4 1.4x10-4 1.4x10-4 1.2x10-4 8.8x10-5 7.9x10-5 5.3x10-5 5.0x10-5 3.1x10-5 2.0x10-5 1.3x10-5 7.5x10-6 Conductor no x ø (mm) 196x0.40 7x2.14 125x0.40 7x1.72 1x4.50 80x0.40 7x1.38 1x3.60 84x0.30 7x1.50 1x2.76 56x0.30 7x0.86 1x2.25 50x0.25 7x0.68 1x1.78 30x0.25 7x0.52 1x1.4 32x0.20 7x0.43 1x1.15 42x0.15 28x0.20 1x1.0 28x0.15 16x0.20 1x0.80 7x0.25 1x0.60 14x0.15 7x0.20 18x0.10 14x0.10 21x0.07 14x0.10 Max ø (mm) Max ø (in) Section (mm2) Section (sq in) 7.50 6.10 6.00 4.90 4.50 4.70 3.95 3.60 3.70 3.15 2.76 2.80 2.58 2.25 2.15 2.04 1.78 1.60 1.56 1.40 1.35 1.29 1.15 1.20 1.15 1.00 0.95 0.90 0.80 0.75 0.60 0.75 0.65 0.50 0.40 0.40 0.40 0.295 0.240 0.236 0.192 0.177 0.155 0.155 0.141 0.145 0.124 0.108 0.110 0.098 0.082 0.084 0.080 0.070 0.062 0.061 0.055 0.053 0.050 0.045 0.047 0.045 0.039 0.037 0.035 0.031 0.029 0.023 0.029 0.023 0.019 0.015 0.015 0.015 25.00 25.00 16.00 16.00 16.00 10.00 10.00 10.00 6.00 6.00 6.00 4.00 4.00 4.00 2.50 2.50 2.50 1.50 1.50 1.50 1.00 1.00 1.00 0.75 0.75 0.75 0.50 0.50 0.50 0.34 0.28 0.25 0.22 0.14 0.11 0.09 0.09 0.0387 0.0387 0.0248 0.0248 0.0248 0.0155 0.0155 0.0155 0.0093 0.0093 0.0093 0.0062 0.0062 0.0062 0.0038 0.0038 0.0038 0.0023 0.0023 0.0023 0.0015 0.0015 0.0015 0.0011 0.0011 0.0011 7.7x10-4 7.7x10-4 7.7x10-4 5.2x10-4 4.3x10-4 3.8x10-4 3.4x10-4 2.1x10-4 1.7x10-4 1.3x10-4 1.3x10-4 Note: 1) not included in the standard www.lemo.com Product safety notice PLEASE READ AND FOLLOW ALL INSTUCTIONS CAREFULLY AND CONSULT ALL RELEVENT NATIONAL AND INTERNATIONAL SAFETY REGULATIONS FOR YOUR APPLICATION. IMPROPER HANDLING, CABLE ASSEMBLY, OR WRONG USE OF CONNECTORS CAN RESULT IN HAZARDOUS SITUATIONS. 1. SHOCK AND FIRE HAZARD Incorrect wiring, the use of damaged components, presence of foreign objects (such as metal debris), and / or residue (such as cleaning fluids), can result in short circuits, overheating, and / or risk of electric shock. Mated components should never be disconnected while live as this may result in an exposed electric arc and local overheating, resulting in possible damage to components. 2. HANDLING Connectors and their components should be visually inspected for damage prior to installation and assembly. Suspect components should be rejected or returned to the factory for verification. Connector assembly and installation should only be carried out by properly trained personnel. Proper tools must be used during installation and / or assembly in order to obtain safe and reliable performance. 3. USE Connectors with exposed contacts should never be live (or on the current supply side of a circuit). Under general conditions voltages above 30 VAC and 42 VDC are considered hazardous and proper measures should be taken to eliminate all risk of transmission of such voltages to any exposed metal part of the connector. 4. TEST AND OPERATING VOLTAGES The maximum admissible operating voltage depends upon the national or international standards in force for the application in question. Air and creepage distances impact the operating voltage; reference values are indicated in the catalog however these may be influenced by PC board design and / or wiring harnesses. The test voltage indicated in the catalog is 75% of the mean breakdown voltage; the test is applied at 500 V/s and the test duration is 1 minute. 5. CE MARKING CE marking means that the appliance or equipment bearing it complies with the protection requirements of one or several European safety directives. CE marking applies to complete products or equipment, but not to electromechanical components, such as connectors. 6. PRODUCT IMPROVEMENTS The LEMO Group reserves the right to modify and improve to our products or specifications without providing prior notification. www.lemo.com 15 Notes 16 www.lemo.com LEMO complete product range B S K E F 00 01 0A 3T 4A 4M 3K. 1D 93C Y 05 5G 2G 2C L H M R N 03 V W F P D K/S 01 DIN Unipole Multipole Coaxial 50 Ω Coaxial 75 Ω Multi Coaxial Mixed Coax + LV Triaxial 50 Ω Triaxial 75 Ω Mixed Triax + LV Quadrax High Voltage Multi High Voltage Mixed HV + LV Fibre Optic Multi Fibre Optic Mixed FO + LV Thermocouple Fluidic Multi Fluidic Mixed Fluidic + LV Most frequently used in darker colour B Series Keyed S Series K Series Keyed E Series F Series Keyed 00 Series 01 Series 0A Series 3T Series 4A Series 4M Series Keyed 3K.93C Series Keyed 1D Series Y Series 05 Series 5G Series Keyed 2G Series Keyed 2C Series L Series Keyed H Series M Series Keyed R Series Keyed N Series Keyed 03 Series Keyed V Series W Series Keyed Cable assembly K/S Series Keyed REDEL F Series P REDEL Series Keyed D REDEL Series 01 Series Keyed VAA Series SAA Series TAA Series No reproduction or use without express permission of editorial or pictorial content, in any manner. LEMO SA reserves the right to modify and improve specifications, at all times, without any notification. LEMO HEADQUARTERS SWITZERLAND LEMO SA Chemin des Champs-Courbes 28 - P.O. Box 194 - CH-1024 Ecublens Tel. (+41 21) 695 16 00 - Fax (+41 21) 695 16 02 - e-mail: info@lemo.com SUBSIDIARIES AUSTRIA LEMO Elektronik GesmbH Lemböckgasse 49/E6-3 1230 Wien Tel: (+43 1) 914 23 20 0 Fax:(+43 1) 914 23 20 11 sales@lemo.at NETHERLANDS / BELGIUM LEMO Connectors Benelux De Trompet 2108 1967 DC Heemskerk Tel. (+31) 251 25 78 20 Fax (+31) 251 25 78 21 info@lemo.nl CHINA LEMO Trading (Shanghai) Co., Ltd LEMO Electronics (Shanghai) Co., Ltd 5th Floor, Block 6, City of ELITE, 1000 Jinhai Road, Pudong Shanghai, China 201206 Tel: (+86 21) 5899 7721 Fax: (+86 21) 5899 7727 cn.sales@lemo.com NORWAY / ICELAND LEMO Norway A/S Stanseveien 6B 0975 Oslo Tel: (+47) 22 91 70 40 Fax: (+47) 22 91 70 41 info-no@lemo.com DENMARK LEMO Denmark A/S Gammel Mosevej 46 2820 Gentofte Tel: (+45) 45 20 44 00 Fax: (+45) 45 20 44 01 info-dk@lemo.com FRANCE LEMO France Sàrl 24/28 Avenue Graham Bell Bâtiment Balthus 4 Bussy Saint Georges 77607 Marne la Vallée Cedex 3 Tel: (+33 1) 60 94 60 94 Fax: (+33 1) 60 94 60 90 info-fr@lemo.com GERMANY LEMO Elektronik GmbH Hanns-Schwindt-Str. 6 81829 München Tel: (+49 89) 42 77 03 Fax: (+49 89) 420 21 92 info@lemo.de HONG KONG LEMO Hong Kong Ltd Unit 1207, 12/F, Corporation Square, 8 Lam Lok Street, Kowloon Bay, Kowloon - Hong Kong Tel: (+852) 2174 0468 Fax: (+852) 2174 0492 hk.sales@lemo.com HUNGARY REDEL Elektronika Kft Nagysándor József u. 6-12 1201 Budapest Tel: (+36 1) 421 47 10 Fax: (+36 1) 421 47 57 redelemo@lemo.hu ITALY LEMO Italia srl Viale Lunigiana 25 20125 Milano Tel: (+39 02) 66 71 10 46 Fax: (+39 02) 66 71 10 66 sales.it@lemo.com JAPAN LEMO Japan Ltd 4-10-3, Takaido Higashi, Suginami-ku, Tokyo, 168-0072 Tel: (+81 3) 53 44 39 33 Fax: (+81 3) 53 44 39 35 lemoinfo@lemo.co.jp LEMO SINGAPORE LEMO Asia Pte Ltd 4 Leng Kee Road, #06-09 SiS Building Singapore 159088 Tel: (+65) 6476 0672 Fax: (+65) 6474 0672 sg.sales@lemo.com SPAIN / PORTUGAL IBERLEMO S.A. Brasil, 45, 08402 Granollers Barcelona Tel: (+34 93) 860 44 20 Fax: (+34 93) 879 10 77 info-es@lemo.com Madrid Office Antonio López, 96, 28019 Madrid Tel: (+34 91) 469 99 19 Fax: (+34 91) 469 99 59 SWEDEN / FINLAND LEMO Nordic AB Mariehällsvägen 39A 168 65 Bromma Tel: (+46 8) 635 60 60 Fax: (+46 8) 635 60 61 info-se@lemo.com SWITZERLAND LEMO Verkauf AG Grundstrasse 22 B 6343 Rotkreuz Tel: (+41 41) 790 49 40 Fax: (+41 41) 790 49 43 ch.sales@lemo.com UNITED KINGDOM LEMO UK Ltd 12-20 North Street Worthing West Sussex, BN11 1DU Tel: (+44 1903) 23 45 43 Fax: (+44 1903) 20 62 31 lemouk@lemo.com USA LEMO USA Inc P.O. Box 2408 Rohnert Park, CA 94927-2408 Tel: (+1 707) 578 88 11 (+1 800) 444 53 66 Fax:(+1 707) 578 08 69 info@lemousa.com DISTRIBUTORS AUSTRALIA, BRAZIL, CANADA, CZECH REPUBLIC, GREECE, INDIA, ISRAEL, NEW ZEALAND, PAKISTAN, POLAND, RUSSIA, SOUTH AFRICA, SOUTH KOREA, TAIWAN, TURKEY, UKRAINE 18 www.lemo.com © CAT.XP.REN.P1010, updated October, 2011 LEMO
XAN.M13.GLA.6G 价格&库存

很抱歉,暂时无法提供与“XAN.M13.GLA.6G”相匹配的价格&库存,您可以联系我们找货

免费人工找货