0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
PDM2-S24-D12-D

PDM2-S24-D12-D

  • 厂商:

    CUIDEVICES

  • 封装:

    -

  • 描述:

    DC/DCCONVERTER+/-12V2W

  • 数据手册
  • 价格&库存
PDM2-S24-D12-D 数据手册
Additional Resources: Product Page | 3D Model | PCB Footprint date 10/11/2022 page 1 of 6 SERIES: PDM2-D │ DESCRIPTION: DC-DC CONVERTER FEATURES • • • • • • • • • 2 W isolated output smaller package single/dual unregulated output 1,500 Vdc isolation short circuit protection extended temperature range (-40~105°C) antistatic protection up to 8kV high efficiency at light load efficiency up to 85% MODEL input voltage output voltage output current output power ripple and noise2 efficiency typ (Vdc) range (Vdc) (Vdc) min (mA) max (mA) max (W) typ (mVp-p) typ (%) PDM2-S3-S5-D 3.3 2.97~3.63 5 40 400 2 75 78 PDM2-S5-S5-D 5 4.5~5.5 5 40 400 2 75 80 PDM2-S5-S12-D1 5 4.5~5.5 12 17 167 2 75 84 PDM2-S5-S15-D 5 4.5~5.5 15 13 133 2 75 84 PDM2-S5-D5-D1 5 4.5~5.5 ±5 ±20 ±200 2 75 80 PDM2-S5-D7-D 5 4.5~5.5 ±7 ±15 ±142 2 75 80 PDM2-S5-D9-D1 5 4.5~5.5 ±9 ±11 ±111 2 75 84 1 PDM2-S5-D12-D 5 4.5~5.5 ±12 ±8 ±83 2 75 84 PDM2-S5-D15-D1 5 4.5~5.5 ±15 ±7 ±67 2 75 84 PDM2-S12-S5-D 12 10.8~13.2 5 40 400 2 75 80 PDM2-S12-S12-D1 12 10.8~13.2 12 17 167 2 75 82 PDM2-S12-S24-D 12 10.8~13.2 24 8 83 2 75 84 PDM2-S12-D5-D1 12 10.8~13.2 ±5 ±20 ±200 2 75 80 PDM2-S12-D9-D 12 10.8~13.2 ±9 ±11 ±111 2 75 84 PDM2-S12-D12-D1 12 10.8~13.2 ±12 ±8 ±83 2 75 83 PDM2-S12-D15-D 12 10.8~13.2 ±15 ±7 ±67 2 75 84 1 PDM2-S24-S5-D 24 21.6~26.4 5 40 400 2 75 79 PDM2-S24-S9-D1 24 21.6~26.4 9 22 222 2 75 85 PDM2-S24-S12-D 24 21.6~26.4 12 17 167 2 75 83 PDM2-S24-D5-D1 24 21.6~26.4 ±5 ±20 ±200 2 75 79 1 PDM2-S24-D12-D 24 21.6~26.4 ±12 ±8 ±83 2 75 83 PDM2-S24-D15-D1 24 21.6~26.4 ±15 ±7 ±67 2 75 84 1 1 1 1 1 1 1 Notes: 1. UL approved 2. Ripple and noise are measured at 20 MHz BW by “parallel cable” method with 1 μF ceramic and 10 μF electrolytic capacitors on the output. cui.com Additional Resources: Product Page | 3D Model | PCB Footprint CUI Inc │ SERIES: PDM2-D │ DESCRIPTION: DC-DC CONVERTER date 10/11/2022 │ page 2 of 6 PART NUMBER KEY PDM2 - SXX - XXX -D Base Number Input Voltage Output S = single D = dual Packaging Style DIP Output Voltage INPUT parameter conditions/description min typ max units operating input voltage 3.3 Vdc input models 5 Vdc input models 12 Vdc input models 24 Vdc input models 2.97 4.5 10.8 21.6 3.3 5 12 24 3.63 5.5 13.2 26.4 Vdc Vdc Vdc Vdc surge voltage for maximum of 1 second 3.3 Vdc input models 5 Vdc input models 12 Vdc input models 24 Vdc input models -0.7 -0.7 -0.7 -0.7 5 9 18 30 Vdc Vdc Vdc Vdc filter capacitance filter max units ±1.2 % OUTPUT parameter conditions/description line regulation for Vin change of 1% min load regulation measured from 10%~100% load 5 Vdc output models 9 Vdc output models 12 Vdc output models 15 Vdc output models 24 Vdc output models voltage accuracy see tolerance envelope curve switching frequency 100% load, nominal input voltage temperature coefficient at 100% load typ 12 9 8 7 6 % % % % % 100 kHz ±0.03 %/°C max units 1 s max units PROTECTIONS parameter conditions/description min typ short circuit protection1 Notes: 1. The supply voltage must be discontinued at the end of the short circuit duration SAFETY AND COMPLIANCE parameter conditions/description isolation voltage input to output for 1 minute, 1 mA max. leakage current 1,500 Vdc isolation resistance input to output at 500 Vdc 1,000 MΩ safety approvals certified to 60950-1: UL conducted emissions CISPR22/EN55022, class B, external circuit required radiated emissions CISPR22/EN55022, class B, external circuit required ESD IEC/EN61000-4-2, class B, contact ± 8kV for single outputs IEC/EN61000-4-2, class B, contact ± 6kV for dual outputs MTBF as per MIL-HDBK-217F at 25°C 2 RoHS Notes: min 3,500,000 2011/65/EU 2. See specific models listed on page 1 cui.com typ hours Additional Resources: Product Page | 3D Model | PCB Footprint CUI Inc │ SERIES: PDM2-D │ DESCRIPTION: DC-DC CONVERTER date 10/11/2022 │ page 3 of 6 ENVIRONMENTAL parameter conditions/description min max units operating temperature see derating curve -40 105 °C -55 125 °C 95 % storage temperature storage humidity non-condensing temperature rise Ta=25°C, 100% load typ 25 °C SOLDERABILITY parameter conditions/description hand soldering wave soldering min typ max units 1.5 mm from case for 10 seconds 300 °C see wave soldering profile 260 °C max units MECHANICAL parameter conditions/description dimensions 20.32 x 10.16 x 8.2 (0.800 x 0.400 x 0.323 inch) min case material epoxy resin (UL94-V0) weight typ mm 2.8 g MECHANICAL DRAWING units: mm[inch] tolerance: ±0.25[±0.010] pin section tolerance: ±0.10[±0.004] PIN CONNECTIONS PIN Single Output Dual Output 1 GND GND 7 NC NC 8 0V 0V 9 +Vo +Vo 11 NO PIN -Vo 14 Vin Vin Front View Bottom View cui.com Top View PCB Layout Additional Resources: Product Page | 3D Model | PCB Footprint CUI Inc │ SERIES: PDM2-D │ DESCRIPTION: DC-DC CONVERTER date 10/11/2022 │ page 4 of 6 DERATING CURVES EMC RECOMMENDED CIRCUIT Figure 1 Table 1 Recommended external circuit components Vin (Vdc) C1, C2 CY LDM 3.3 4.7μF/50V -- 6.8μH 5 4.7μF/50V -- 6.8μH 12 4.7μF/50V -- 6.8μH 24 4.7μF/50V 1nF/2KV 6.8μH Note: cui.com 1. See Table 2 for Cout values Additional Resources: Product Page | 3D Model | PCB Footprint CUI Inc │ SERIES: PDM2-D │ DESCRIPTION: DC-DC CONVERTER date 10/11/2022 │ page 5 of 6 APPLICATION NOTES 1. Output load requirement To ensure this module can operate efficiently and reliably, the minimum output load may not be less than 10% of the full load during operation. If the actual output power is low, connect a resistor at the output end in parallel to increase the load. 2. Overload Protection Under normal operating conditions, the output circuit of this product has no protection against overload. The simplest method to add this is to add a circuit breaker to the circuit. 3. Recommended circuit If you want to further decrease the input/output ripple, you can increase the capacitance accordingly or choose capacitors with low ESR (see Figure 2 & Table 2). However, the capacitance of the output filter capacitor must be appropriate. If the capacitance is too high, a startup problem might arise. For every channel of the output, to ensure safe and reliable operation, the maximum capacitance must be less than the maximum capacitive load (see Table 3). Figure 2 Single output Dual output Table 2 Cout (µF) Dual Vo (Vdc) Cout (µF) Single Vout (Vdc) Max. Capacitive Load (μF) Dual Vout (Vdc) Max. Capacitive Load1 (μF) 5 10 ±5 4.7 5 220 5 100 9 4.7 ±9 2.2 9 220 7 100 2.2 12 2.2 ±12 1 12 220 9 100 1 15/24 1 ±15 0.47 15 220 12 100 220 15 100 Vin (Vdc) Cin (µF) Single Vo (Vdc) 3.3 4.7 5 4.7 12 24 Note: Note: Table 3 It’s not recommended to connect any external capacitors in applications with less than 0.5 watt output. 24 Note: 1. For each output. 1. Operation under minimum load will not damage the converter; however, they may not meet all specifications listed. 2. Max. capacitive load tested at input voltage range and full load. 3. All specifications measured at: Ta=25°C, humidity
PDM2-S24-D12-D 价格&库存

很抱歉,暂时无法提供与“PDM2-S24-D12-D”相匹配的价格&库存,您可以联系我们找货

免费人工找货