Ribbon Cable connector Compliant with MIL Standard HIF3B Series ■Features 1. Product Compliant with MIL Standard HIF3B series has been developed as a product compliant with MIL standard, and used for wide applications. 2. UL Approval Product HIF3B series connectors are UL approved. Nov.1.2022 Copyright 2022 HIROSE ELECTRIC CO., LTD. All Rights Reserved. 3. Mechanism to Prevent Mis-insertion This connector is equipped with the mechanism to prevent Misinsertion as follows. 1 The system provides the convex area to insert the guide-key on the pin header side, and to guide it in combination with the socket convex area (MIL standard). 2 The system embeds and guides the polarizing key in the socket holes. 4. Applicable Cable 28 AWG (IDC type) The applicable cable is UL2651 28 AWG flat cable (7cores./0.127mm, jacket dia. 0.9±0.1mm). ■Product Specifications Rating Current rating : Operating Temperature Range : Storage Temperature Range : IDC : 1A 28 AWG Crimp : 32, 36 AWG : 1A Other : 3A –55 to +85ç (Note 1) –10 to +60ç (Note 2) Voltage rating : Operating Moisture Range : Storage Humidity Range : 200V 40 to 80% 40 to 70% (Note 2) Item 1. Insulation Resistance Specification Condition 1000Mø min. 500V DC 2. Withstanding voltage No flashover or insulation breakdown. 650V AC/1 minute 3. Contact Resistance 15mø max. 0.1A 4. Vibration No electrical discontinuity of 1μs or more Frequency : 10 to 55 Hz, single amplitude of 0.75 mm, 2 hours in each of the 3 directions. 5. Humidity (Steady state) Insulation resistance : 1000Mø min. 6. Temperature Cycle 96 hours at temperature of 40ç and humidity of 90% to 95% (-55ç : 30 minutes ➝ 15 to 35ç : 5 minutes max. No damage, cracks, or parts looseness. 125ç : 30 minutes ➝ 15 to 35ç : 5 minutes max.) 5 cycles 7. Durability (Mating/un-mating) Contact resistance : 15mø max. 500 cycles Solder bath : 260ç for 10 seconds 8. Resistance to Soldering heat No deformation of components affecting performance. Manual soldering : 360ç for 5 seconds Note 1 : Includes temperature rise caused by current flow. Note 2 : The term "storage" refers to products stored for long period of time prior to mounting and use. Operating Temperature Range and Humidity range covers non conducting condition of installed connectors in storage, shipment or during transportation. Note 3 : Information contained in this catalog represents general requirements for this Series. Contact us for the drawings and specifications for a specific part number shown. Note 4 : Please note that there is a risk of deforming the lock when an excessive load is applied to the inside. ■Material / Finish Part Material Finish Remarks Insulator PBT Black UL94V-0 Socket Contact Beryllium copper Pin header contact Brass Connection area Gold plated Selective Gold plated ––––––– ––––––– B15 HIF3B Series●Ribbon Cable connector Compliant with MIL Standard ■Product Number Structure Refer to the chart below when determining the product specifications from the product number. Please select from the product numbers listed in this catalog when placing orders. ●Socket HIF 3B - * D - 2.54 R q w e r t y q Series Name : HIF w Series No. : 3B, 3BA, 3BB (50, 60, 64 contacts only) e Number of contacts : 6,10,14,16, 20, 26, 30, 34, 40, 50, 60, 64 Nov.1.2022 Copyright 2022 HIROSE ELECTRIC CO., LTD. All Rights Reserved. r Contact alignment : D : Double t Contact pitch : 2.54mm y Connection type R : ID type ●Pin Header HIF 3B - * P A - 2.54 DS q w e q Series Name : HIF w Series No. : r t y u : (14 contacts not included) 3BC : (10 contacts only) 3B 3BA, 3BB : (50, 60, 64 contacts only) 3BD : (10 contacts only) e Number of contacts : 6,10,14,16, 20, 26, 30, 34, 40, 50, 60, 64 r P : Pin header t A : Selective gold plated y Contact pitch : 2.54mm u Contact style B16 DS : Right angle type DSA : Straight type HIF3B Series●Ribbon Cable connector Compliant with MIL Standard Nov.1.2022 Copyright 2022 HIROSE ELECTRIC CO., LTD. All Rights Reserved. ■Socket (With guide to prevent mis-insertion) Body Protector Clamp Note1, Note2 : The number of polarizing keys and polarizing keyways changes according to products. Refer to the list as shown below. Note3 : The 50, 60 and 64 contact connector contain two types of polarizing guides. Use the products, referring to Notes 1 and 2. Note4 : The 6 contact has no polarizing mark. Unit : mm Part No. HRS No. No. of Contacts A B C D Polarizing Guide (Note 1) HIF3BA- 6D-2.54R(63) 610-0032-3 63 6 12.19 5.08 6.35 7.72 HIF3BA-10D-2.54R(63) 610-0021-7 63 10 17.27 10.16 11.43 12.8 ★ HIF3BA-14D-2.54R(63) 610-0022-0 63 14 22.35 15.24 16.51 17.88 ★ HIF3BA-16D-2.54R(63) 610-0023-2 63 16 24.89 17.78 19.05 20.42 ★ HIF3BA-20D-2.54R(63) 610-0024-5 63 20 29.97 22.86 24.13 25.5 ★ HIF3BA-26D-2.54R(63) 610-0025-8 63 26 37.59 30.48 31.75 33.12 ★ HIF3BA-30D-2.54R(63) 610-0026-0 63 30 42.67 35.56 36.83 38.2 ★ HIF3BA-34D-2.54R(63) 610-0027-3 63 34 47.75 40.64 41.91 43.28 ★ HIF3BA-40D-2.54R(63) 610-0028-6 63 40 55.37 48.26 49.53 50.9 ★ HIF3BA-50D-2.54R(63) 610-0029-9 63 50 68.07 60.96 62.23 63.6 One on right and left sides, resp. ★ HIF3BB-50D-2.54R(63) 610-0041-4 63 50 68.07 60.96 62.23 63.6 ★ HIF3BA-60D-2.54R(63) 610-0030-8 63 60 80.77 73.66 74.93 76.3 One on right and left sides, resp. ★ HIF3BB-60D-2.54R(63) 610-0042-7 63 60 80.77 73.66 74.93 76.3 ★ HIF3BA-64D-2.54R(63) 610-0031-0 63 64 85.85 78.74 80.01 81.38 One on right and left sides, resp. ★ HIF3BB-64D-2.54R(63) 610-0043-0 63 64 85.85 78.74 80.01 81.38 Polarizing Keyway (Note 2) RoHS None One on left side One at center YES One on right and left sides, resp. One at center One at center One at center The products marked with ★ comply with MIL standard. B17 HIF3B Series●Ribbon Cable connector Compliant with MIL Standard Nov.1.2022 Copyright 2022 HIROSE ELECTRIC CO., LTD. All Rights Reserved. ■Socket Body Protector Clamp Note1 : The number of polarizing keys and polarizing keyways changes according to products. For details, refer to the list as shown below. Note2 : The 6 contact has no polarizing mark. Unit : mm Part No. HRS No. No. of Contacts A B C D HIF3B- 6D-2.54R(63) 610-0012-6 63 6 12.19 5.08 6.35 7.72 ★ HIF3B-10D-2.54R(63) 610-0001-0 63 ★ HIF3B-14D-2.54R(63) 610-0002-2 63 10 17.27 10.16 11.43 12.80 14 22.35 15.24 16.51 17.88 ★ HIF3B-16D-2.54R(63) 610-0003-5 63 ★ HIF3B-20D-2.54R(63) 610-0004-8 63 16 24.89 17.78 19.05 20.42 20 29.97 22.86 24.13 25.50 ★ HIF3B-26D-2.54R(63) 610-0005-0 63 ★ HIF3B-30D-2.54R(63) 610-0006-3 63 26 37.59 30.48 31.75 33.12 30 42.67 35.56 36.83 38.2 ★ HIF3B-34D-2.54R(63) 610-0007-6 63 ★ HIF3B-40D-2.54R(63) 610-0008-9 63 34 47.75 40.64 41.91 43.28 40 55.37 48.26 49.53 50.90 ★ HIF3B-50D-2.54R(63) 610-0009-1 63 ★ HIF3B-60D-2.54R(63) 610-0010-0 63 50 68.07 60.96 62.23 63.6 60 80.77 73.66 74.93 76.3 ★ HIF3B-64D-2.54R(63) 610-0011-3 63 64 85.85 78.74 80.01 81.38 Polarizing Guide (Note 1) RoHS None One on left side YES One on right and left sides, resp. The products marked with ★ comply with MIL standard. B18 HIF3B Series●Ribbon Cable connector Compliant with MIL Standard Nov.1.2022 Copyright 2022 HIROSE ELECTRIC CO., LTD. All Rights Reserved. ■Four Wall Angle Through hole BPCB mounting pattern Note 1, Note 2 : The number of polarizing slot and key installed positions changes according to products. Refer to the list as shown below. Note 3 : The spacer moves to the right according to the number of contacts. Note 4 : The 10, 50, 60 and 64 contact connectors contain two types of polarizing slots. Use products, referring to (Note 1) (Note 2). ■n=number of contacts Unit : mm Part No. HRS No. No. of Contacts A B C ★ HIF3BA-10PA-2.54DS(63) 610-0091-2 63 10 32.0 17.5 10.16 HIF3BD-10PA-2.54DS(63) 610-0171-0 63 10 32.0 17.5 10.16 ★ HIF3BA-14PA-2.54DS(63) 610-0092-5 63 14 37.1 22.6 15.24 ★ HIF3BA-16PA-2.54DS(63) 610-0093-8 63 16 39.6 25.1 17.78 ★ HIF3BA-20PA-2.54DS(63) 610-0094-0 63 20 44.7 30.2 22.86 ★ HIF3BA-26PA-2.54DS(63) 610-0095-3 63 26 52.3 37.8 30.48 ★ HIF3BA-30PA-2.54DS(63) 610-0096-6 63 30 57.4 42.9 35.56 ★ HIF3BA-34PA-2.54DS(63) 610-0097-9 63 34 62.5 48.0 40.64 ★ HIF3BA-40PA-2.54DS(63) 610-0098-1 63 40 70.1 55.6 48.26 ★ HIF3BA-50PA-2.54DS(63) 610-0099-4 63 50 82.8 68.3 60.96 ★ HIF3BB-50PA-2.54DS(63) 610-0131-5 63 50 82.8 68.3 60.96 ★ HIF3BA-60PA-2.54DS(63) 610-0100-1 63 60 95.5 81.0 73.66 ★ HIF3BB-60PA-2.54DS(63) 610-0132-8 63 60 95.5 81.0 73.66 ★ HIF3BA-64PA-2.54DS(63) 610-0101-4 63 64 100.6 86.1 78.74 ★ HIF3BB-64PA-2.54DS(63) 610-0133-0 63 64 100.6 86.1 78.74 D 28.14 MAX51.1 28.14 MAX51.1 33.24 MAX56.2 35.74 MAX58.7 40.84 MAX63.8 48.44 MAX71.4 53.54 MAX76.5 58.64 MAX81.6 66.24 MAX89.2 78.94 MAX101.9 78.94 MAX101.9 91.64 MAX114.6 91.64 MAX114.6 96.74 MAX119.7 96.74 MAX119.7 E F 21.8 27.9 Polarizing Slot (Note 1) None Polarizing Key Install RoHS (Note 2) One on right side 21.8 27.9 None 26.9 33.0 One on right side 29.5 35.5 34.5 40.6 42.2 48.3 One at center 47.2 53.3 YES 52.3 58.4 59.9 66.0 72.6 78.7 One on right and left sides, resp. 72.6 78.7 One on right and left sides, resp. One at center 85.3 91.4 One on right and left sides, resp. 85.3 91.4 One at center 90.4 96.5 One on right and left sides, resp. 90.4 96.5 One at center The products marked with ★ comply with MIL standard. B19 HIF3B Series●Ribbon Cable connector Compliant with MIL Standard Nov.1.2022 Copyright 2022 HIROSE ELECTRIC CO., LTD. All Rights Reserved. ■Four-Wall Straight Through hole BPCB mounting pattern Note 1, Note 2 : The number of polarizing slot and key installed positions changes according to products. Refer to the list as shown below. Note 3 : The spacer moves to the right according to the number of contacts. Note 4 : The 10, 50, 60 and 64 contact connectors contain two types of polarizing slots. Use products, confirming (Note 1) (Note 2). Note 5 : The 6 contact has no polarity mark. ■n=number of contacts Unit : mm Part No. HRS No. No. of Contacts 562-0503-9 71 6 26.92 12.42 05.08 HIF3BA-10PA-2.54DSA(63) 610-0111-8 63 10 32.0 17.5 10.16 ★ HIF3BD-10PA-2.54DSA(63) 610-0181-3 63 ★ HIF3BA-14PA-2.54DSA(63) 610-0112-0 63 10 32.0 17.5 10.16 14 37.1 22.6 15.24 ★ HIF3BA-16PA-2.54DSA(63) 610-0113-3 63 ★ HIF3BA-20PA-2.54DSA(63) 610-0114-6 63 16 39.6 25.1 17.78 20 44.7 30.2 22.86 ★ HIF3BA-26PA-2.54DSA(63) 610-0115-9 63 ★ HIF3BA-30PA-2.54DSA(63) 610-0116-1 63 26 52.3 37.8 30.48 30 57.4 42.9 35.56 ★ HIF3BA-34PA-2.54DSA(63) 610-0117-4 63 ★ HIF3BA-40PA-2.54DSA(63) 610-0118-7 63 34 62.5 48.0 40.64 40 70.1 55.6 48.26 ★ HIF3BA-50PA-2.54DSA(63) 610-0119-0 63 ★ HIF3BB-50PA-2.54DSA(63) 610-0141-9 63 50 82.8 68.3 60.96 50 82.8 68.3 60.96 ★ HIF3BA-60PA-2.54DSA(63) 610-0120-9 63 ★ HIF3BB-60PA-2.54DSA(63) 610-0142-1 63 60 95.5 81.0 73.66 ★ HIF3-6PA-2.54DSA(71) ★ HIF3BA-64PA-2.54DSA(63) 610-0121-1 63 ★ HIF3BB-64PA-2.54DSA(63) 610-0143-4 63 A B C 60 95.5 81.0 73.66 64 100.6 86.1 78.74 64 100.6 86.1 78.74 D 23.06 MAX46.02 28.14 MAX51.1 28.14 MAX51.1 33.24 MAX56.2 35.74 MAX58.7 40.84 MAX63.8 48.44 MAX71.4 53.54 MAX76.5 58.64 MAX81.6 66.24 MAX89.2 78.94 MAX101.9 78.94 MAX101.9 91.64 MAX114.6 91.64 MAX114.6 96.74 MAX119.7 96.74 MAX119.7 E F Polarizing Slot (Note 1) Polarizing Key Install RoHS (Note 2) 16.7 22.82 One at center None 21.8 27.9 None One on right side 21.8 27.9 None 26.9 33.0 One on right side 29.5 35.5 34.5 40.6 42.2 48.3 One at center 47.2 53.3 YES 52.3 58.4 59.9 66.0 72.6 78.7 One on right and left sides, resp. 72.6 78.7 One on right and left sides, resp. One at center 85.3 91.4 One on right and left sides, resp. 85.3 91.4 One at center 90.4 96.5 One on right and left sides, resp. 90.4 96.5 One at center The products marked with ★ comply with MIL standard. B20 HIF3B Series●Ribbon Cable connector Compliant with MIL Standard Nov.1.2022 Copyright 2022 HIROSE ELECTRIC CO., LTD. All Rights Reserved. ■Three Wall Angle Type BPCB mounting pattern Note 1, Note 2 : The number of polarizing slot and key installed positions changes according to products. Refer to the list as shown below. Note 3 : The spacer moves according to the number of contacts. Note 4 : The 10 contact connector consists of two types. Use products, confirming (Note 1) (Note 2). ■n=number of contacts Unit : mm Part No. HRS No. No. of Contacts A B C ★ HIF3BD-10PA-2.54DS(63) 610-0051-8 63 10 32.0 17.5 10.16 HIF3BC-10PA-2.54DS(63) 610-0151-2 63 10 32.0 17.5 10.16 ★ HIF3BD-16PA-2.54DS(63) 610-0052-0 63 16 39.6 25.1 17.78 ★ HIF3BD-20PA-2.54DS(63) 610-0053-3 63 20 44.7 30.2 22.86 ★ HIF3BD-26PA-2.54DS(63) 610-0054-6 63 26 52.3 37.8 30.48 ★ HIF3BD-30PA-2.54DS(63) 610-0055-9 63 30 57.4 42.9 35.56 ★ HIF3BD-34PA-2.54DS(63) 610-0056-1 63 34 62.5 48.0 40.64 ★ HIF3BD-40PA-2.54DS(63) 610-0057-4 63 40 70.1 55.6 48.26 ★ HIF3BD-50PA-2.54DS(63) 610-0058-7 63 50 82.8 68.3 60.96 ★ HIF3BD-60PA-2.54DS(63) 610-0059-0 63 60 95.5 81.0 73.66 ★ HIF3BD-64PA-2.54DS(63) 610-0060-9 63 64 100.6 86.1 78.74 D 28.14 MAX51.1 28.14 MAX51.1 35.74 MAX58.7 40.84 MAX63.8 48.44 MAX71.4 53.54 MAX76.5 58.64 MAX81.6 66.24 MAX89.2 78.94 MAX101.9 91.64 MAX114.6 96.74 MAX119.7 E F 21.8 27.9 Polarizing Slot (Note 1) Polarizing Key Install (Note 2) None One on right side 21.8 27.9 RoHS None 29.5 35.5 34.5 40.6 42.2 48.3 One at center 47.2 53.3 52.3 58.4 One on right and left sides, resp. YES 59.9 66.0 72.6 78.7 85.3 91.4 One on right and left sides, resp. 90.4 96.5 The products marked with ★ comply with MIL standard. B21 HIF3B Series●Ribbon Cable connector Compliant with MIL Standard ■Four Wall Straight Through hole Nov.1.2022 Copyright 2022 HIROSE ELECTRIC CO., LTD. All Rights Reserved. [Flux Blister Prevention Type] BPCB mounting pattern Note1 : The number of polarizing slot and key installed positions changes according to products. Refer to the list as shown below. ■n=number of contacts Unit : mm Part No. HRS No. No. of Contacts A B C ★ HIF3CA-10PA-2.54DSA(63) 610-0701-1 63 10 32.0 17.5 10.16 HIF3CD-10PA-2.54DSA(63) 610-0722-1 63 10 32.0 17.5 10.16 ★ HIF3CA-16PA-2.54DSA(63) 610-0703-7 63 16 39.6 25.1 17.78 ★ HIF3CA-20PA-2.54DSA(63) 610-0704-0 63 20 44.7 30.2 22.86 ★ HIF3CA-26PA-2.54DSA(63) 610-0705-2 63 26 52.3 37.8 30.48 ★ HIF3CA-30PA-2.54DSA(63) 610-0706-5 63 30 57.4 42.9 35.56 ★ HIF3CA-34PA-2.54DSA(63) 610-0707-8 63 34 62.5 48.0 40.64 ★ HIF3CA-40PA-2.54DSA(63) 610-0708-0 63 40 70.1 55.6 48.26 ★ HIF3CA-50PA-2.54DSA(63) 610-0709-3 63 50 82.8 68.3 60.96 ★ HIF3CB-50PA-2.54DSA(63) 610-0721-9 63 50 82.8 68.3 60.96 ★ HIF3CB-60PA-2.54DSA(63) 610-0723-4 63 60 95.5 81.0 73.66 ★ HIF3CB-64PA-2.54DSA(63) 610-0724-7 63 64 100.6 86.1 78.74 D 28.14 MAX51.1 28.14 MAX51.1 35.74 MAX58.7 40.84 MAX63.8 48.44 MAX71.4 53.54 MAX76.5 58.64 MAX81.6 66.24 MAX89.2 78.94 MAX101.9 78.94 MAX101.9 91.64 MAX114.6 96.74 MAX119.7 E F 21.8 27.9 Polarizing Slot None 21.8 27.9 Polarizing Key Install RoHS One on right side None 29.5 35.5 34.5 40.6 42.2 48.3 One at center 47.2 53.3 YES 52.3 58.4 One on right and left sides, resp. 59.9 66.0 72.6 78.7 One on right and left sides, resp. 72.6 78.7 85.3 91.4 One at center 90.4 96.5 The products marked with ★ comply with MIL standard. B22 HIF3B Series●Ribbon Cable connector Compliant with MIL Standard BPolarizing Key Nov.1.2022 Copyright 2022 HIROSE ELECTRIC CO., LTD. All Rights Reserved. HIF3B-GK 562-0601-8 HIF3-GPIN(A) HIF3BA-GPIN Note1 : One unit of this product is a set of five pieces in conjunction with a runner. The unit for sale is defined one pack containing 20 pieces. Note2 : This product is applicable to HIF3A*D2.54R, HIF3C*D2.54C and HIF3BA-*D2.54C products. Part No. HRS No. Material Remarks Note1 : One unit of this product is a set of five pieces in conjunction with a runner. The unit for sale is defined one pack containing 20 pieces. Note2 : This product is applicable to the HIF3BA-*D2.54R product. RoHS HIF3-GPIN(A) 562-0126-6 Poly acetal (white) A set of 5 pieces YES Part No. HRS No. Material Remarks RoHS HIF3BA-GPIN 612-0500-2 Poly acetal (white) A set of 5 pieces YES B23 HIF3B Series●Ribbon Cable connector Compliant with MIL Standard BLock Lock G Lock F Part Number : HIF3BAG-**PA-2.54DSA(63) Part Number : HIF3BAG-**PA-2.54DSA(63) Nov.1.2022 Copyright 2022 HIROSE ELECTRIC CO., LTD. All Rights Reserved. ●Low profile type, and used for lock ejection. Connector height is reduced. Since no connector clamp is needed on the cable side, this is used without turning back on the cable side. Take care about this point. B24 27.3 ●F Type Lock Pin Header 21.5 ●Low Profile Lock Pin Header ●Locking range more reduced than conventional lock type. Even if connectors are aligned laterally, the mounting space is reduced. Note : The clamp must be replaced for HIF3A socket type 60 contacts only. Take care about this point. HIF3B Series●Ribbon Cable connector Compliant with MIL Standard Nov.1.2022 Copyright 2022 HIROSE ELECTRIC CO., LTD. All Rights Reserved. ■Socket for Crimping Unit : mm Part No. HRS No. No. of Contacts A B HIF3BA-10D-2.54C(63) 610-1041-0 63 10 17.25 10.16 HIF3BA-14D-2.54C(63) 610-1051-3 63 14 22.35 15.24 HIF3BA-16D-2.54C(63) 610-1042-2 63 16 24.8 17.78 HIF3BA-20D-2.54C(63) 610-1043-5 63 20 29.95 22.86 HIF3BA-26D-2.54C(63) 610-1044-8 63 26 37.55 30.48 HIF3BA-30D-2.54C(63) 610-1045-0 63 30 42.63 35.56 HIF3BA-34D-2.54C(63) 610-1046-3 63 34 47.75 40.64 HIF3BA-40D-2.54C(63) 610-1047-6 63 40 55.35 48.26 HIF3BA-50D-2.54C(63) 610-1048-9 63 610-1061-7 63 68.04 60.96 HIF3BB-50D-2.54C(63) 50 HIF3BA-60D-2.54C(63) 610-1049-1 63 HIF3BB-60D-2.54C(63) 610-1062-0 63 HIF3BA-64D-2.54C(63) 610-1064-5 63 HIF3BB-64D-2.54C(63) 610-1063-2 63 60 80.77 73.66 64 85.85 78.74 Polarizing Guide RoHS One at center YES One right and left side, resp. One at center One right and left side, resp. One at center One right and left side, resp. One at center Note : Some variations may differ from those in above figures. B25 HIF3B Series●Ribbon Cable connector Compliant with MIL Standard Nov.1.2022 Copyright 2022 HIROSE ELECTRIC CO., LTD. All Rights Reserved. ■Cover Case for Crimping socket Unit : mm Part No. HRS No. No. of Contacts A B C D E HIF3-20CV(72) 562-0201-0 72 20 24.5 18.0 12.0 30.5 29.95 HIF3-26CV(72) 562-0202-2 72 26 30.2 20.0 14.0 32.0 37.55 HIF3-30CV(72) 562-0203-5 72 30 32.2 22.0 16.0 33.0 42.63 HIF3-34CV(72) 562-0204-8 72 34 34.2 24.0 18.0 33.5 47.75 HIF3-40CV(72) 562-0205-0 72 40 36.2 26.0 20.0 35.5 55.35 HIF3-50CV(72) 562-0206-3 72 50 39.2 29.0 23.0 38.0 68.04 HIF3-60CV(72) 562-0207-6 72 60 42.2 32.0 26.0 40.5 80.77 Note 1 : The type F lock pin header cannot be used for a mating member. Note 2 : Note that the product cannot be used with AWG #20. Applicable jacket diameters are as described below. 20 contacts : 1.7mm diameter MAX 26 to 40 contacts : 1.6mm diameter MAX 50 to 60 contacts : 1.4mm diameter MAX B26 RoHS YES HIF3B Series●Ribbon Cable connector Compliant with MIL Standard Nov.1.2022 Copyright 2022 HIROSE ELECTRIC CO., LTD. All Rights Reserved. BContact (Crimping Contact for Socket) B27 HIF3B Series●Ribbon Cable connector Compliant with MIL Standard BTools ●Crimping Tool Nov.1.2022 Copyright 2022 HIROSE ELECTRIC CO., LTD. All Rights Reserved. Manual Crimping Tool Part No. HRS No. HIF3-T2226HC 550-0063-8 Part No. HRS No. CM-105C 901-0001-0 HIF3-T2226HC ●Automatic Crimping Tool (Type : CM-105C) ●Contact Extraction Tools Part No. HRS No. HIF1-PO 550-0049-7 How to use the extraction tool (1) How to extract contacts (2) How to adjust the lance (raise) As shown in Figure 1, where the extraction tool is inserted in the lance fixed slot on the insulated case, slightly pull the cable, and the contact can be removed. In order to re-insert the contact removed from the insulated case, raise the contact lance area using the tool A, and re-insert the contact, as shown in Figure 2. Figure 1 B28 HIF3B Series●Ribbon Cable connector Compliant with MIL Standard BSocket Side (Crimping) Assembling Procedures (1) As shown in Figure 1, peel the applicable cable (AWG#20 to #26) jacket, and connect it using crimping jig HIF3-TA2022HC, HIF3-TA2226HC, or HIF3-TA2426HC. In this case, insert the cable so as to hit the contact cable stripper position as shown Figure 2. (2) After connection as shown Figure 2, check the contact direction, and insert the contact as shown Figures 3 and 4. Slightly pull the cable, and check whether the contact lance position is firmly fixed to the insulation case, as shown in the area (A). Note1 : For handling procedures for special crimping tools, refer to the "Handling Instruction Manual". Nov.1.2022 Copyright 2022 HIROSE ELECTRIC CO., LTD. All Rights Reserved. Note2 : Wire strip length : Refer to crimp condition sheet. Wire strip length Figure 1 Figure 2 Figure 3 Figure 4 B29
HIF3BA-30D-2.54R(11)
物料型号: - 该系列连接器有多种型号,包括HIF3B、HIF3BA、HIF3BB等,具体型号取决于接触点的数量和类型。

器件简介: - HIF3B系列连接器是符合MIL标准的带状电缆连接器,具有UL认证,设计用于防止误插,并适用于多种应用场景。

引脚分配: - 引脚分配根据连接器的型号和规格有所不同,文档提供了详细的引脚分配图和表格。

参数特性: - 包括电流额定值、操作和存储温度范围、绝缘电阻、耐电压、接触电阻、振动、湿度、温度循环、耐久性以及对焊接热的抵抗性等。

功能详解: - 连接器具备防止误插的机制,包括引脚侧的凸出区域和插座的凸出区域配合使用,以及插座孔中的极化键嵌入和引导。

应用信息: - 适用电缆为UL2651 28 AWG平电缆,外径为0.9±0.1mm。

封装信息: - 提供了详细的尺寸图和封装规格,包括不同型号的连接器的尺寸和形状。

材料/表面处理: - 绝缘体材料为PBT,接触材料为铍铜,表面处理为黑色,连接区域为金镀层。

产品编号结构: - 详细说明了如何根据产品编号确定产品规格,并提供了不同型号的编号示例。

组装程序: - 文档提供了带状电缆连接器的组装程序,包括剥线、连接、检查接触方向和固定接触。