Technical Data Sheet for SP2402
Multi-Stage Thermoelectric Module
NOMINAL PERFORMANCE IN NITROGEN
Hot Side Temperature (°C)
Δ Tmax (°C):
Qmax (watts):
Imax (amps):
Vmax (vdc):
AC Resistance (ohms):
PRODUCT FEATURES
27
109
8.7
5.3
8.9
1.54
50
123
9.5
5.3
9.9
---
ORDERING OPTIONS
RoHS EU Compliant
Ceramic Material: Aluminum Oxide and Beryllium Oxide.
Pretinned metallized ceramic surface(s) with 117°C solder.
Elevated temperature burn-in with test data available.
-04AB: Special height and parallelism requirements and
lead orientation.
-07AB: Thermistor mounted on edge of cold side ceramic.
Model Number
SP2402-01AB
SP2402-02AB
SP2402-03AB
SP2402-04AB
SP2402-07AB
Description
Metallized, Top and Base
Hot Side Exterior is Metallized
No Metallization
Metallized, Top and Base
Metallized, Thermistor
OPERATION CAUTIONS
INSTALLATION
For maximum reliability, storage and operation below
85°C in a non-condensing environment is recommended.
To minimize thermal stress, use linear/proportional
temperature control or a similar method rather than an
ON/OFF method.
Recommended mounting methods: Bonding with thermal
epoxy or soldering with metallized ceramics. For additional
information, please refer to our TEM Installation Guide.
II-VI Marlow – Dallas, TX USA
214-340-4900
877-627-5691
marlow.sales@ii-vi.com
Marlow Industries Europe
GmbH - Germany
+49 (0) 6150 5439 - 403
info@marlow-europe.eu
II-VI Japan Inc.
81 43 297 2693 (tel)
center@ii-vi.co.jp
www.ii-vi.co.jp
MI Form 005-0685 Rev. 6
II-VI Singapore Pte., Ltd.
(65) 6481 8215 (tel)
info@ii-vi.com.sg
Marlow Industries China, II-VI
Technologies Beijing
86-10-643 98226
info@iivibj.com
DOC # 102-0230 REV L - PAGE 1 OF 2
www.marlow.com
TYPICAL PERFORMANCE CURVES
ENVIRONMENT: ONE ATMOSPHERE DRY NITROGEN
Hot Side Temperature 50°C
Hot Side Temperature 27°C
0.00
1.00
2.00
3.00
4.00
5.00
6.00
7.00
8.00
0.00
1.00
2.00
3.00
4.00
5.00
6.00
7.00
8.00
MECHANICAL CHARACTERISTICS
For performance information in a vacuum or with hot side temperatures other than 27°C or 50°C, contact one of our Applications Engineers at 877-627-5691.
Beryllium Oxide Handling
Precautions
Beryllium oxide can be toxic only when
dust, mist, or fumes containing particles
small enough to enter the lungs are
inhaled. For the user, precautions required
are to avoid grinding, machining or
pulverizing the material by mechanical,
thermal, or chemical processing.
marlow industries, inc.
R
All units are in inches. All units in [ ] are in millimeters.
For customer support or general questions please contact a local office or visit our website at www.marlow.com.
Marlow reserves the right to make product changes without notice.
MI Form 005-0685 Rev. 6
DOC # 102-0230 REV L - PAGE 2 OF 2
www.marlow.com
很抱歉,暂时无法提供与“SP2402-01AB”相匹配的价格&库存,您可以联系我们找货