0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
VQ622T/3

VQ622T/3

  • 厂商:

    SGXSENSORTECH

  • 封装:

    -

  • 描述:

    VQ22 PELLISTOR, VQ600 HEAD, 0.75

  • 数据手册
  • 价格&库存
VQ622T/3 数据手册
SGX Europe Sp. z o.o. Building 11 Ligocka St. 103, 40-568 Katowice, Poland T: +48 (0) 32 438 4778 E: sales.is@sgxsensortech.com www.sgxsensortech.com VQ600 Datasheet Pellistor Gas Sensor for Hazardous Areas (Fixed Systems) The VQ600 Series is designed to detect and monitor various gases in the range 0 to 100% LEL for combustible gases and 0 to 100% volume in thermal conductivity mode when using the SGX range of pellistor gas sensors. The VQ600 Series is designed for use as an integral part of a fixed gas detection system. The head comprises a stainless steel flameproof enclosure constructed with an integral stainless steel sinter which allows the safe entry of the atmosphere being tested. There are three types of mounting thread available to allow easy fixing to the junction box of the fixed system and the facility to attach accessories to the sensor via an external M46 thread. FEATURES   Although SGX generally recommends that pellistors should be run with a constant voltage supply to the bridge, it is possible to use a constant current supply provided that the voltage across the bridge in clean air remains within the recommended limits. Designed for fixed gas detection systems For detection of the following: o Combustible gases (Catalytic Sensors) o             Light gases (e.g. hydrogen and helium). (Thermal Conductivity Sensors) LEL and % Volume Monitoring Diffused gas sampling via sinter Three thread options available Operational in varying temperature, pressure humidity Fast response Rugged stainless steel construction No moving parts Resistance to corrosion Low maintenance Accessories available for field applications ATEX certified CSA certified (Canada and US) The head must be mounted so that the cable is protected. This is normally achieved by mounting it into a port in a suitable junction box. and It is essential that the head be efficiently earthed (grounded). This may be achieved by mounting it either into an earthed metal junction box, or into a non-metallic junction box fitted with an earth continuity plate used in accordance with the box manufacturer's instructions. There are no internal connections to the sensing head body. TECHNICAL SPECIFICATION Mechanical Dimensions Body material Weight See Outline on Page 4 Stainless Steel 435g Environmental OPERATION The pellistor used in the head should be operated in the manner recommended in the appropriate data sheet. In general it is recommended that the detector and compensator be run in a Wheatstone Bridge circuit so that a difference signal may be obtained. A suitable circuit is shown in Fig. 1. In use, the bridge supply voltage should not be allowed to vary by more than the specified +0.1 V, or the output in clean air may change in sympathy. Ambient temperature range for operation (ATEX): for operation (CSA): storage: Operational pressure range Humidity range for operation and storage Gases Detected -20°C to +60°C -20°C to +65°C -20°C to +60°C 700kPa to 1300kPa 0 to 100% RH (Non-condensing) Combustible, Light Gases Electrical DC supply to detectors Typical power See Configurations Table on Page 2 Refer to Pellistor Type Datasheet ___________________________________________________________________________________________ Whilst SGX has taken care to ensure the accuracy of the information contained herein it accepts no responsibility for the consequences of any use thereof and also reserves the right to change the specification of goods without notice. SGX accepts no liability beyond the set out in its standard conditions of sale in respect of infringement of third party patents arising from the use of SGX products in accordance with information contained herein. In case of modification of the product, SGX disclaims all liability. SGX Europe sp .z o.o. Poland REGON: 362332227 DS-0240, Issue 1, 16-May-2016, Page 1 SGX Europe Sp. Z o.o. Building 11 Ligocka St. 103, 40-568 Katowice, Poland T: +48 (0) 32 438 4778 E: sales.is@sgxsensortech.com www.sgxsensortech.com CONFIGURATIONS Base Sensor Type Pellistor Type Operating Voltage (V) (See Note 1) 601 Thread Code Type (See Note 3) Typical Current (mA) VQ1B 2.0 300 603 VQ3B 2.5 605M VQ5MB 2.0 606M VQ6MB 2.0 (See Table Below) Gas Types 1 2 3 Catalytic Yes Yes Yes 330 Catalytic Yes Yes Not Available (See Note 2) 175 Thermal Conductivity Yes Not Available (See Note 2) Not Available (See Note 2) Yes Not Available (See Note 2) 300 Thermal Conductivity Yes 621T VQ21TB 2.0 300 Catalytic Yes Yes Yes 621TS VQ21TSB 2.0 300 Catalytic Yes Not Available (See Note 2) Yes 622T VQ22TB 2.0 175 Catalytic Yes Yes Yes 623 VQ23TB 2.5 335 Catalytic Yes Not Available (See Note 2) Not Available (See Note 2) 625 VQ25B 2.0 300 Catalytic Yes Yes Yes All Flammable Gases All Flammable Gases Light Gases (e.g. H2, He2) Light Gases (e.g. H2, He2) All Flammable Gases All Flammable Gases All Flammable Gases All Flammable Gases Most Flammable Gases (Not including Methane) 631M 635M 641TS VQ31MB VQ35MB VQ41TSB 3.5 4.2 2.0 90 55 100 Thermal Conductivity Thermal Conductivity Catalytic Yes Yes Yes Yes Yes Not Available (See Note 2) Yes Light Gases Yes Light Gases Yes Most Flammable Gases (e.g. H2, He2) (e.g. H2, He2) (Not including Methane) Note 1: Refer to the datasheet for each Pellistor Type for more information. Note 2: If the desired Thread Type is listed as “Not Available” please contact SGX. Note 3: Thermal Conductivity sensors can be operated at voltages different to stated above depending upon target gas type. THREAD CODES The sensing head is supplied with one of three different mounting threads at the user's choice (see outline on Page 4). Thread code 1 2 3 Thread Metric 20 x 1.5 mm ANP (Taper) ½" - 14 NPT ANP (Taper) ¾" - 14 NPT Dimension X (mm) 16.00 19.85 20.16 Taper threads are manufactured in accordance with ANSI/ASME B1.20.1. OPERATING CIRCUIT R1 = R3 = 500 to 5000 , R2  R1/5 R2 provides zero adjustment and may be omitted if not required. © SGX Sensortech 2016 Document subject to disclaimer on page 1 DS-0240, Issue 1, 16-May-2016, Page 2 SGX Europe Sp. Z o.o. Building 11 Ligocka St. 103, 40-568 Katowice, Poland T: +48 (0) 32 438 4778 E: sales.is@sgxsensortech.com www.sgxsensortech.com CERTIFICATION ATEX CSA BAS 01ATEX2110X 2589678 Standards: EN 60079-0:2012 IEC 60079-1:2014 Ed.7 CSA C22.2 No.30 (M1986) CSA C22.2 No.142 (M1987) FM 3600 (Nov 1998) FM 3615 (Feb 2006) Product Marking: II 2G Ex db IIC T5 Gb Class I Groups B,C&D Certificate / File: Certified Manufacturing Locations: SGX Europe Sp. z o.o., Ligocka St. 103, 40-568 Katowice, Poland Certificate Address: SGX Europe Sp. z o.o., Ligocka St. 103, 40-568 Katowice, Poland INSTRUCTIONS SPECIFIC TO HAZARDOUS AREA INSTALLATIONS (Ref : EU ATEX Directive 2014/34/EU) 1. The head is classified as flameproof equipment and is marked: BAS01ATEX2110X II 2G Ex db IIC T5 Gb Tamb = -20°C to +60°C 2W/5V MAX The head should only be used within the limits imposed by this certification and by these conditions of use. 2. The head may be used in a hazardous area without further mechanical protection. However, the cable requires mechanical protection and must be terminated in a suitable enclosure. 3. The head must be efficiently earthed (grounded). This may be achieved by mounting it into an appropriate earthed metal junction box or into a non-metallic junction box fitted with an earth continuity plate used in accordance with the box manufacturer's instructions. There are no internal connections to the sensing head body. 4. In the event that the head becomes embedded in a junction box by over-tightening or corrosion, it may be released by the use of a spanner or wrench on the two flat surfaces on the sides of the body. 5. There are no user serviceable parts inside the body of the sensing head, and no attempt should be made to open the body for any purpose. The unit is non-repairable. 6. The head has not been assessed as a safety device (EHSR 1.5). 7. When installed in outdoor locations where rain or spray could interfere with the safe working of the head, or in indoor locations where water jets, sprays, or hoses are used routinely for cleaning purposes, the head should be fitted with the Weather Cap that is available as an accessory. 8. The end-user/installer should be aware that the certification of the head relies in its construction on the use of the following materials, which are suitable for most common applications: Enclosure ........... Stainless Steel Sinter.................. Stainless Steel Bushing .............. Epoxy resin In accordance with the Note in EN60079-0:2006 Clause 6.1, the end-user/installer shall inform the manufacturer of any adverse conditions that the head may encounter. This is to ensure that the head is not subject to conditions that may cause degradation of these materials. © SGX Sensortech 2016 Document subject to disclaimer on page 1 DS-0240, Issue 1, 16-May-2016, Page 3 SGX Europe Sp. Z o.o. Building 11 Ligocka St. 103, 40-568 Katowice, Poland T: +48 (0) 32 438 4778 E: sales.is@sgxsensortech.com www.sgxsensortech.com OUTLINE (All dimensions in millimetres; dimensions without limits are nominal) Terminal Connections Lead Colour Blue Red Yellow Element Detector Compensator Common ACCESSORIES (All dimensions in millimetres) Three accessories are available to complement the VQ600 Series gas detection head. Flow Cap DAS546633AA Weather Cap DAS546632AA The Flow Cap allows the VQ600 to be used in applications where it is to be aspirated permanently with a pumped or pressurised sample. The cap is made of 316 stainless steel and can be used in a variety of applications involving pumped sampling analysis or detection systems. The Weather Cap protects the VQ600 from water when used in external locations, where rain or spray could interfere with the safe working of the head, or in internal locations where water jets, sprays or hoses are used routinely for cleaning purposes, etc. The cap is made of 316 stainless steel and has been tested to IP64 for effectiveness, and also to ensure that it does not significantly affect the VQ600's performance. © SGX Sensortech 2016 Document subject to disclaimer on page 1 DS-0240, Issue 1, 16-May-2016, Page 4 SGX Europe Sp. Z o.o. Building 11 Ligocka St. 103, 40-568 Katowice, Poland Quick Calibration Hood DPP546618DA T: +48 (0) 32 438 4778 E: sales.is@sgxsensortech.com www.sgxsensortech.com ORDERING INFORMATION (VQ600) VQbase/n BASE SENSOR TYPE Refer to Configurations Table on Page 2 THREAD CODE Refer to Thread Codes Table on Page 2 Examples VQ621T/1 VQ600 series head fitted with VQ21TB pellistor and supplied with 20 x 1.5 mm metric thread cap. VQ603/2 VQ600 series head fitted with VQ3B pellistor and supplied with ½" - 14 NPT American National Pipe Taper thread. The Quick Calibration Hood is constructed from polypropylene, and provides a convenient means of supplying test gases to the VQ600 in the field, for calibration and checking purposes. The assembly push-fits into the central gas access recess of the head, and is designed to accommodate 6 mm ID or ¼" flexible tubing. © SGX Sensortech 2016 Document subject to disclaimer on page 1 DS-0240, Issue 1, 16-May-2016, Page 5
VQ622T/3 价格&库存

很抱歉,暂时无法提供与“VQ622T/3”相匹配的价格&库存,您可以联系我们找货

免费人工找货