3026
page 1 of 2
Particulate Filter 2091, P100
Issue Date 9/1/09
The 3M™ Particulate Filter 2091,
P100 has been developed with
your respiratory needs in mind.
The 2091 provides you
and your workers:
• Comfort. 3M’s Advanced
Electret Media (AEM) provides
a lightweight, easy breathing
combination not found in
fiberglass containing filters.1
• Versatile protection. The 2091
is well suited for a wide range of
oil and non-oil based particulate
contaminants and can be used as
a prefilter for certain chemical
exposures.
• Simplicity. The versatility of this
filter reduces your inventory and
training requirements.
• Compatibility. The 2091 can be
used with 3M’s wide variety of
half and full facepiece designs.2
• Exceptional filter efficiency.
Passing NIOSH’s P-series test
criteria, the 2091 P100 filter
provides a minimum 99.97%
filter efficiency.3
• Durability. The unique flexible
filter material resists abrasion
and wetting. Filters are flame
and water resistant.
• Economy. The 2091 is priced
competitively with other filters
in its class.
3M™ Particulate Filter 2091, P100
Suggested Applications:
• Welding
• Brazing
• Torch cutting
• Metal pouring
• Soldering
• OSHA substance
specific particle
exposures:
– Lead
–Asbestos
–Cadmium
–Arsenic
–4,4'
Methylenedianiline
(MDA)
• Pharmaceutical
manufacturing
References:
1. The 2091 filter contains no components made from fiberglass.
2. The 2091 filter can be used as a stand-alone filter with 3M™ 6000, 7500, 7800 and Ultimate FX FF-400
Series Facepieces or as a prefilter with 3M™ 5000 Series Respirators and 6000 Series Cartridges
(use with 502 adapter).
3. Tested against particles approximately 0.3 micron in size (mass median aerodynamic diameter) per 42 CFR 84.
WARNING
These filters help protect against certain particles.
Misuse may result in sickness or death. Before use,
the wearer must read and understand User Instructions
provided as a part of product packaging. Time use
limitations may apply. For proper use, see package
instructions, supervisor or call 3M OH&ESD Technical
Service in U.S.A., 1-800-243-4630. In Canada, call
1-800-267-4414.
Additional use instructions,
product limitations, approval
labels, and warnings are
included with each facepiece
and filter package.
3026
3M™ Particulate Filter 2091, P100
Use For:
• Solids such as those from
processing minerals, coal,
iron ore, cotton, flour, and
certain other substances.
• Liquid or oil based particles
from sprays that do not also
emit harmful vapors.
• Metal fumes produced from
welding, brazing, cutting and
other operations involving
heating of metals.
• Radioactive particulate materials
such as uranium and plutonium.
• Asbestos.
Do Not Use For:
• Gases and vapors, including those
present in paint spray operations,
unless combined with approved
chemical cartridges.
• Sandblasting.
• Oxygen deficient atmospheres.
• Aerosol concentrations
that exceed:
– 10 times the permissible
exposure limit (PEL) with
half facepiece, or
– 10 times the PEL with full
facepiece qualitatively fit
tested, or
– 50 times the PEL with full
facepiece quantitatively
fit tested, or
– applicable government
regulations, whichever
is lower.
Important
Before using these filters, you
must determine the following:
1. The type of contaminant(s)
for which the respirator is
being selected.
2. The concentration level
of contaminant(s).
3. Whether the respirator can be
properly fitted on the wearer’s
face. Do not use with beards,
other facial hair, or other
conditions that prevent a good
seal between the face and the
faceseal of the respirator.
4. Before use of these respirators,
a written respiratory protection
program must be implemented,
meeting all the requirements
of OSHA 29 CFR 1910.134,
including training, medical
evaluation and fit testing.
Time Use Limitation
If filter becomes damaged, soiled,
or breathing becomes difficult, leave
the contaminated area and dispose
of the filter. If used in environments
containing only oil aerosols, dispose
of filter after 40 hours of use or
30 days, whichever is first.
Occupational Health and Environmental Safety Division
3M Center, Building 235-2E-91
St. Paul, MN 55144-1000
page 2 of 2
Technologies
Advanced
Electret Media
Advanced
electrostatically
charged microfibers
make breathing easier
and cooler.
P-Series Filter
Featuring Advanced
Electret Media,
appropriate for
prolonged use
in both oil- and
non-oil-containing
environments.
Filters
Per Box
Filters
Per Case
2
100
For more information, please contact:
3M Occupational Health and
Environmental Safety Division
(OH&ESD)
In the U.S., contact:
Customer Service
1-800-328-1667
Technical Assistance
1-800-243-4630
Website
www.3M.com/OccSafety
For other 3M products
1-800-3M HELPS
In Canada, contact:
3M Canada Company, OH&ESD
P.O. Box 5757
London, Ontario N6A 4T1
Customer Care
1-800-364-3577
Technical Assistance (Canada only)
1-800-267-4414
Website
www.3M.ca/safety
Technical Assistance In Mexico
01-800-712-0646
5270-2255, 5270-2119 (Mexico City only)
Technical Assistance In Brazil
0800-132333