3M™ Specialty Terminals
71F-250-32-NBL, 72F-250-32-NBL
Female Disconnect, Nylon Fully Insulated
with Insulation Grip
Data Sheet
January 2017
Wire
Range
(AWG)
Mates with
Male Tab
Width
x Thickness
L
W
71F-250-32-NBL
22-18
0.250 x 0.032
0.87
72F-250-32-NBL
16-14
0.250 x 0.032
0.87
Product
Number
Agency Approvals
and Self
Certifications
Specifications
Maximum
Insulation
Diameter
D
Barrel
Length
Barrel
I.D.
0.37
0.23
0.25
0.080
0.145
0.37
0.23
0.25
0.080
0.145
UL Standard No. 310, 3M File No. E70512
CSA Standard No. 22.2,
3M File No. LR22190
Max. Voltage Rating:
600 V Building Wire
1000 V Signs, Fixtures (Luminaires)
Max. Operating Temp:
221°F (105°C)
Max. Current:
Same as Wire
Wire Size
See Table above
Barrel Seam:
Butted with Insulation Grip
Insulator Material:
Nylon
Terminal Material:
Brass
Insulation Grip Material:
Brass
Plating:
Tin
1 of 3
3Μ
3M™ Specialty Terminals 71F-250-32-NBL, 72F-250-32-NBL
Installation
Information
UL Listed and CSA Certified for use on stranded copper (AWG) wire only.
Strip away the end 3/8 inch of wire insulation.
Make the crimp in the proper station of a recommended 3M Scotchlok™ Crimp
Tool: TH-440, TH-450 (scissor style), or TR-482, TR-490 (ratchet style), hand
tools.
Barrel Crimp (Electrical)
Insulation Crimp (Mechanical)
Suitable for factory installation on steel or brass tabs, UL and CSA.
Suitable for field application on brass tabs, strain relief is required, UL only.
Engineering
Specification
Crimp-Type Female Disconnect shall, electrically and mechanically, connect
permanently to the prestripped end of a stranded copper wire: and have a tongue
portion which grip a Male Disconnect in a separable, reusable manner, forming a Quick
Connect Wiring Termination.
The connector line shall offer tongue variations (sized to grip male tabs 0.250˝ x 0.032˝
or 0.187˝ x 0.020˝ per ANSI/NEMA CD-2) and construction, non- insulated, nylon
insulated with insulation grip, nylon fully insulated, etc. The Female Disconnects shall
have regulatory agency coverage, UL Listing, CSA Certification. The tongue portion
shall be marked with the wire range and manufacturer’s symbol ( ).
Insulated connectors shall be UL Listed and CSA Certified for 600 V building wire:
1000 V signs or lighting fixtures (luminaires) and temperature rated 221˚F (105˚C)
maximum.
Female Disconnects shall be suitable for field or factory wiring, with a UL
Recognized strain relief required.