FP-301 Tubing
Flexible Polyolefin
Data Sheet
Product Description
Standard Colors
Typical Applications
3M™ FP-301 Tubing offers an outstanding
balance of electrical, physical and
chemical properties for a wide variety of
industrial and military applications. Rated
for 135°C continuous operation, all
FP-301 Tubing is split resistant,
mechanically tough, easily marked and
resists cold flow.
FP-301 Tubing is typically used as a
shrink-fit electrical insulation over cable
splices and terminations. It is also used for
lightweight wire harness covering, wire
marking, wire bundling, component
packaging and fire-resistant covering.
Shrink Ratio
FP-301 Tubing meets MIL-DTL-23053/5
Class 1 & 2 and AMS-3636, AMS-3637
requirements. It is ULRecognized and
CSACertified at 600 volts @ 125°C (UL
File Nos. E-39100 and E-69751; CSANo.
38227).
FP-301 polyolefin tubing has a 2:1 shrink
ratio. When freely recovered, the tubing
will shrink to 50% of its as-supplied
internal diameter. The recovered wall
thickness of the tubing is proportional to
the degree of recovery.
FP-301 Tubing is rated for continuous
operation from –55°C (–67°F) to 135°C
(275°F) and withstands elevated
temperatures to 300°C (572°F) for short
periods. Minimum shrink temperature for
all FP-301 Tubing is 100°C (212°F).
High expansion-ratio FP-301 Tubing
meeting MIL-DTL-23053/5 Class 1
requirements for overexpansion is
available subject to factory quotation.
FP-301, Class 1 (flame retardant)–black,
white, red, blue, green (1/16 "-1" green
only) and yellow. FP-301, Class 2 (nonflame retardant)–clear. Other colors
available subject to factory quotation.
Standard Packaging
Four-foot lengths, large spools
(21" diameter) and small spools
(8-1/2" diameter).
Ordering Information
Order FP-301 by product name, size
equivalent to expanded inside diameter,
package type and color. Always order the
largest size that will shrink snugly over the
item to be covered.
Example: FP-301, 1/4", 4 ft., white.
Typical Properties
Applicable Specification
MIL-DTL-23053/5, Class 1, 2; AMS-3636, AMS-3637;
UL File E-39100, E-69751; CSALR38227; ABS
Standard Sizes and Dimensions
Ordering
Size
3/64
1/16
3/32
1/8
3/16
1/4
3/8
1/2
3/4
1
1-1/2
2
3
4
Expanded ID
Minimum
Recoverd ID
Maximum
in.
(mm)
in.
.046
.063
.093
.125
.187
.250
.375
.500
.750
1.000
1.500
2.000
3.000
4.000
(1,17)
(1,60)
(2,36)
(3,18)
(4,75)
(6,35)
(9,53)
(12,70)
(19,05)
(25,40)
(38,10)
(50,80)
(76,20)
(101,60)
.023
.031
.046
.062
.093
.125
.187
.250
.375
.500
.750
1.000
1.500
2.000
(mm)
Recoverd Wall
Thickness
(Nominal)
in.
(mm)
(0,58)
(0,79)
(1,17)
(1,57)
(2,36)
(3,18)
(4,75)
(6,35)
(9,53)
(12,70)
(19,05)
(25,40)
(38,10)
(50,80)
.016
.017
.020
.020
.020
.025
.025
.025
.030
.035
.040
.045
.050
.055
(0,41)
(0,43)
(0,51)
(0,51)
(0,51)
(0,64)
(0,64)
(0,64)
(0,76)
(0,89)
(1,02)
(1,14)
(1,27)
(1,40)
Physical
Electrical
Tensile Strength
2400 PSI
Ultimate Elongation
400%
Longitudinal Change
±5%
Secant Modulus
(2%)
13,000 PSI
Specific Gravity
1.3(Black)
.93 (Clear)
Heat Aging
Elongation
(336 hrs. @ 175°C)
175%
Heat Shock
No dripping,
(4 hrs. @ 250°C)
cracking,
passes mandrel
wrap test
Low Temperature Flexibility
(4 hrs. @ –55°C) No cracking
Flammability
Self-extinguish
meets UL 224
All-Tubing
Flame Test
(Class 1 only)
Dielectric Strength
900 V/mil
Volume Resistivity 1015 ohm-cm
Chemical
Corrosive Effect Non-corrosive
Solvent Resistance
Tensile Strength
1000 PSI
Dielectric Strength
400 V/mil
Water Absorption
0.2%
Fungus Resistance Non-nutrient
Technical information provided consists of typical product data and
should not be used for specification purposes. Unless otherwise
noted, all tests are performed at room temperature.