8
TM
3M
7
6
5
4
3
2
1
NOTES
TWISTED PAIR FLAT CABLE, HF100 SERIES
.050" 28 AWG STRANDED, MASS TERMINABLE, HALOGEN FREE PO
TABLE 1
19.68
[500]
.71 SEE NOTE 5
1.97
[50]
D
.32
NO. OF
CONDUCTORS
10 (5 PAIR)
14 (7 PAIR)
16 (8 PAIR)
20 (10 PAIR)
24 (12 PAIR)
26 (13 PAIR)
30 (15 PAIR)
34 (17 PAIR)
40 (20 PAIR)
50 (25 PAIR)
60 (32 PAIR)
64 (32 PAIR)
3M PART
NUMBER
HF100/10TP
HF100/14TP
HF100/16TP
HF100/20TP
HF100/24TP
HF100/26TP
HF100/30TP
HF100/34TP
HF100/40TP
HF100/50TP
HF100/60TP
HF100/64TP
DIM. "A"
DIM. "B"
.50 [12.7]
.70 [17.8]
.80 [20.3]
1.00 [2.4]
1.20 [30.5]
1.30 [33.0]
1.50 [38.1]
1.70 [43.2]
2.00 [50.8]
2.50 [63.5]
3.00 [76.2]
3.20 [81.3]
.450+/-.010 [11.43]
.650+/-.010 [15.88]
.750+/-.010 [20.96]
.950+/-.010 [22.23]
1.150+/-.010 [24.77]
1.250+/-.010 [31.12]
1.450+/-.015 [36.80]
1.650+/-.015 [37.47]
1.950+/-.015 [42.55]
2.450+/-.015 [50.17]
2.950+/-.015 [62.87]
3.150+/-.015 [80.01]
* LOW SMOKE ZERO HALOGEN (LSZH)
INSULATION. ADVANTAGES OF LSZH
INSULATION ARE THE LOW SMOKE
(IEC 61034-2-2005) AND LOW
TOXICITY OF COMBUSTION GASES
(NF X 70-100-2-2006), REDUCING
THE RISK TO FIREFIGHTERS AND
REDUCING THE SOOT AND CORROSION
DAMAGE TO NEARBY EQUIPMENT.
* 28 AWG WIRE ON .050 INCH CENTERS
PERMITS MASS TERMINATION TO BROAD
LINE OF IDC CONNECTORS.
1. REGULATORY INFORMATION:
VISIT 3M.com/regs OR CONTACT
YOUR 3M REPRESENTATIVE TO FIND
THE RoHS COMPLIANCE STATUS OF
THE 3M PART YOU ARE INTERESTED
IN.
2 IN THE EVENT OF CONFLICT
BETWEEN THIS DATA AND THAT
CONTAINED IN THE PRODUCT
SPECIFICATION, THE PRODUCT
SPECIFICATION TAKES PRECEDENT.
4
BLUE EDGE CONDUCTOR DESIGNATES
WIRE ONE OF PAIR ONE.
5
STANDARD PRODUCT HAS A 2" FLAT
ON 19.7" REPEAT (50MM BOND ON
500MM REPEAT). FOR SPECIAL
REQUIREMENTS, PLEASE CONTACT
YOUR 3M SALES REPRESENTATIVE.
THE FLAT CAN BE SPECIFIED
ANYTHING OVER 1" {25MM}, THE
REPEAT CAN BE SPECIFIED FROM
6.5" TO 48" {16.5CM TO 1.2M].
D
DIM. "A"
PHYSICAL:
2
.100
REF.
INSULATION:
MATERIAL: HALOGEN FREE POLYOLEFIN (PO)
COLOR: BLUE / WHITE PAIRS
2.54
.07
C
REF.
C
MARKING:
STANDARD: NONE
CANADIAN OPTION: SEE "PRINTING ILLUSTRATION" VIEW
1.8
CONDUCTORS: 28 AWG, 7 X 36 AWG [7 X
.127] TINNED STRANDED COPPER
SECTION THRU TWIST
ELECTRICAL:
TYP.
1.27
28 AWG 7 X 36 (7 X .127) TINNED
STRANDED COPPER CONDUCTORS
CHARACTERISTIC IMPEDANCE:
CAPACITANCE:
INDUCTANCE:
PROPAGATION DELAY:
VELOCITY OF PROPAGATION:
BLUE
(SEE NOTE 4)
UNBALANCED
102
16.9 pF/ft [55.4 pF/m]
.18 H/ft [.59 H/m]
1.74 ns/ft [5.71 ns/m]
58%
BALANCED
119
14.6 pF/ft [47.9 pF/m]
.21 H/ft [.69 H/m]
1.73 ns/ft [5.68 ns/m]
59%
D
.050
DRAWING NUMBER
DARK GRAY
EU: 1 X 10
/10ft. [3m]
78-5100-2344-9
2
NOTE: UNBALANCED IS MEASURED BETWEEN GROUND-SIGNAL-GROUND CONDUCTORS.
BALANCED IS MEASURED BETWEEN CONDUCTORS WITHIN A PAIR.
PO CARRIER
B
DIM. "B"
PERTAINS TO BONDED
AREA ONLY
.043 .003
[1.09]
2
ENVIRONMENTAL:
B
TEMPERATURE RATING: -40 C TO +105 C (EIA-364-32G, METHOD A, TEST CONDITION 2)
-15 C TO +105 C (UL TEMPERATUE RATING)
FLAMMABILITY RATING: UL: HORIZONTAL
HALOGEN FREE IS DEFINED AS BOTH 1) NO HALOGN COMPOUNDS THAT ARE INTENTIONALLY ADDED TO THE
PRODUCT OR USED IN THE MANUFACTURING PROCESS FOR THE PRODUCT AND 2) ANY IMPURITIES PRESENT
ARE LESS THAN 900ppm BROMINE, LESS THAN 900ppm CHLORINE AND/OR LESS THAN 1500ppm TOTAL
BROMINE AND CHLORINE. THE LATTER ARE THE LEVELS SET FORTH IN CERTIAN INDUSTRY STANDARDS FOR
PRINTED CIRCUIT BOARDS, SUCH AS THE INTERNATIONAL ELECTROTECHNICAL COMMISSION (IEC) 61249-2-21
STANDARDS. THIS INFORMATION REPRESENTS 3M'S KNOWLEDGE AND BELIEF WHICH MAY BE BASED IN WHOLE
OR IN PART ON INFORMATION PROVIDED BY 3RD PARTY SUPPLIERS TO 3M.
ORDERING INFORMATION
HF100/XX TP XX
BLANK = STANDARD
SF = SPLICE FREE
NUMBER OF CONDUCTORS
(SEE TABLE)
NOTE:
AVAILABLE IN STANDARD LENGTHS OF 100 FT AND 300 FT PER ROLL,
PLEASE SPECIFY WHEN ORDERING.
D
INCH [MM]
TOLERANCE - UNLESS NOTED
.X .XX
.XXX
[INCH] .1 .01
.005
[] = DIM. FOR REFERENCE ONLY
CANADIAN OPTION
"PRINTING ILLUSTRATION"
R
3M ELECTRONICS MATERIALS SOLUTIONS DIVISION
INTERCONNECT SOLUTIONS
http://www.3Mconnectors.com
AWM 21008 105 C 150V HOR
DESIGN REFERENCE
NEXT ASSEMBLY
ACCESS
CODES
DIVISION
DO NOT
SCALE
DRAWING
INCHES
MAX SURFACE ROUGHNESS
ALL SURFACES
MARKED ONLY
7
6
5
4
3
ISSUE DATE AND DESCRIPTION
DATE
CASTIGLIONE
JUN 11,2018
CHKD
DATE
C
3M Center
St. Paul,
TOLERANCES
EXCEPT AS
NOTED
INTERPRET PER
ASME Y14.5 - 2009
UL FILE NO: E42769,
UL STYLE NO: 21008
ECO
DRFT
EMSD
SCALE
THIRD ANGLE PROJECTION
AWM 1A 105 C 150V FT2 EU
很抱歉,暂时无法提供与“HF100/40TP”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格 香港价格
- 100+51.52711100+6.42274
- 200+46.76647200+5.82934
- 300+44.21138300+5.51085
- 500+41.21706500+5.13762
- 700+39.37366700+4.90784
- 1000+37.525061000+4.67742