ROUND CONDUCTOR FLAT CABLE, HF365 SERIES
* LOW SMOKE ZERO HALOGEN (LSZH) INSULATION. ADVANTAGES
OF LSZH INSULATION ARE THE LOW SMOKE (IEC 61034-2-2005)
AND LOW TOXICITY OF COMBUSTION GASES (NF X 70-100-2-2006),
REDUCING THE RISK TO FIREFIGHTERS AND REDUCING THE SOOT
AND CORROSION DAMAGE TO NEARBY EQUIPMENT.
.050" 28 AWG STRANDED, HALOGEN FREE PO
* 28 AWG WIRE ON .050 INCH CENTERS PERMITS MASS TERMINATION
TO BROAD LINE OF IDC CONNECTORS.
2
IN THE EVENT OF CONFLICT
BETWEEN THIS DATA AND THAT
CONTAINED IN THE PRODUCT
SPECIFICATION, THE PRODUCT
SPECIFICATION TAKES PRECEDENT.
* ZIPPABLE FOR BRANCHING OR DISCRETE TERMINATION.
DIM. "A"
D
1. REGULATORY INFORMATION:
VISIT 3M.com/regs OR CONTACT
YOUR 3M REPRESENTATIVE TO FIND
THE RoHS COMPLIANCE STATUS OF
THE 3M PART YOU ARE INTERESTED
IN.
D
DIM. "B"
TABLE 1
1.27
DIM. "A"
DIM. "B"
04
06
08
09
10
11
12
14
15
16
18
20
24
25
26
30
34
36
37
40
44
50
60
64
HF365/04
HF365/06
HF365/08
HF365/09
HF365/10
HF365/11
HF365/12
HF365/14
HF365/15
HF365/16
HF365/18
HF365/20
HF365/24
HF365/25
HF365/26
HF365/30
HF365/34
HF365/36
HF365/37
HF365/40
HF365/44
HF365/50
HF365/60
HF365/64
.200+/-.010 [5.08]
.300+/-.010 [7.62]
.400+/-.010 [10.16]
.450+/-.010 [11.43]
.500+/-.010 [12.70]
.550+/-.010 [13.97]
.600+/-.010 [15.24]
.700+/-.010 [17.78]
.750+/-.010 [19.05]
.800+/-.015 [20.32]
.900+/-.015 [22.88]
1.000+/-.015 [25.40]
1.200+/-.015 [30.48]
1.250+/-.015 [31.75]
1.300+/-.015 [33.02]
1.500+/-.020 [38.10]
1.700+/-.020 [43.18]
1.800+/-.020 [45.72]
1.850+/-.020 [46.99]
2.000+/-.020 [50.80]
2.200+/-.020 [55.88]
2.500+/-.020 [63.50]
3.000+/-.020 [76.20]
3.200+/-.020 [81.28]
.150+/-.007 [3.81]
.250+/-.007 [6.35]
.350+/-.007 [8.89]
.400+/-.007 [10.16]
.450+/-.007 [11.43]
.500+/-.007 [12.70]
.550+/-.007 [13.97]
.650+/-.007 [16.51]
.700+/-.007 [17.78]
.750+/-.011 [19.05]
.850+/-.011 [21.59]
.950+/-.011 [24.13]
1.150+/-.011 [29.21]
1.200+/-.011 [30.48]
1.250+/-.011 [31.75]
1.450+/-.015 [36.83]
1.650+/-.015 [41.91]
1.750+/-.015 [44.45]
1.800+/-.015 [45.72]
1.950+/-.015 [49.53]
2.150+/-.015 [54.61]
2.450+/-.015 [62.23]
2.950+/-.015 [74.93]
3.150+/-.015 [80.01]
0.05
TYP.
.035
.003
0.89
28 AWG 7 X 36 (7 X
.127) TINNED
STRANDED COPPER CONDUCTORS
0.08
HALOGEN FREE PO
C
NOTE:
BLUE MARKING ON ONE EDGE OF CABLE DESIGNATES WIRE #1.
2
PHYSICAL:
JACKET MATERIAL: HALOGEN FREE POLYOLEFIN (PO)
COLOR: DARK GRAY
2
.127] TINNED STRANDED COPPER
ELECTRICAL:
VOLTAGE RATING: USA 300V
CANADIAN 150V
10
INSULATION RESISTANCE: >1 X 10
/10ft. [3m]
B
DRAWING NUMBER
MARKING:
STANDARD: NONE
CONDUCTORS: 28 AWG 7 X 36AWG [7 X
CHARACTERISTIC IMPEDANCE:
CAPACITANCE:
INDUCTANCE:
PROPAGATION DELAY:
VELOCITY OF PROPAGATION:
UNBALANCED
100
15.0 pF/ft [49.2 pF/m]
.15 H/ft [.49 H/m]
1.51 ns/ft [4.95 ns/m]
68%
EU: