3M™ Scotchlok™ Terminals
MNG18-250DFI, MNG14-250DFI
Female Disconnect, Nylon Fully Insulated
with Insulation Grip
Data Sheet
August 2014
Product
Number
Wire
Range
(AWG)
Mates with
Male Tab
Width (W´ )
x Thickness
L
W
MNG18-250DFI
22-18
0.250 x 0.032
0.87
MNG14-250DFI
16-14
0.250 x 0.032
0.87
Specifications
Maximum
Insulation
Diameter
D
Barrel
Length
Barrel
I.D.
0.37
0.23
0.25
0.080
0.145
0.37
0.23
0.25
0.080
0.145
UL Standard No. 310, 3M File No. E750512
CSA Standard No. 22.2,
3M File No. LR22190
Max. Voltage Rating:
600 V Building Wire
1000 V Signs, Fixtures (Luminaires)
Max. Operating Temp:
Max. Current:
Wire Size
Barrel Seam:
Insulator Material:
Terminal Material:
Insulator Grip Material:
Plating:
221°F (105°C)
Same as Wire
See Table above
Butted with Insulation Grip
Nylon
Brass
Brass
Tin
1 of 3
3
3M™ Scotchlok™ Terminals MNG18-250DFI, MNG14-250DFI
Installation
Information
UL Listed and CSA Certified for use on stranded copper (AWG) wire only.
Strip away the end 3/8 inch of wire insulation.
Make the crimp in the proper station of a recommended 3M™ Scotchlok™
Crimp Tool: TH-440, TH-450 (scissor style), or TR-482, TR-490 (ratchet style)
hand tools.
Barrel Crimp Electrical
Insulation Crimp (Mechanical)
Suitable for factory installation on steel or brass tabs, UL and CSA.
Suitable for field application on brass tabs, strain relief is required, UL only.
Engineering
Specification
Crimp-Type Female Disconnect shall, electrically and mechanically, connect
permanently to the prestripped end of a stranded copper wire: and have a tongue
portion with fingers which grip a Male Disconnect in a separable, reusable manner,
forming a Quick Connect Wiring Termination.
The connector line shall offer tongue variations (sized to grip male tabs 0.250˝ x
0.032˝ or 0.187˝ x 0.020˝ per ANSI/NEMA CD-2) and barrel variations in wire (AWG)
size (22-18, 16-14, 12-10) and construction (non-insulated, nylon-insulated with
insulation grip, and nylon fully insulated, etc.. The female disconnect shall have
regulatory agency coverage (UL Listed, CSA Certification). The tongue portion shall
be marked with the wire range and manufacturer’s symbol ().
The Nylon Fully Insulated 0.250˝ Female Disconnect with Insulation Grip and
interlocking barrel shall be tin plated 0.020˝ thick brass with a tongue for gripping a
0.250˝ x 0.032˝ Male Tab per ANSI/NEMA CD-2 and a 0.25˝ long barrel with a tin
plated brass funnel entry insulation grip, covered by a molded nylon sleeve, which
extends to cover the tongue, color coded and sized for a specified (AWG) wire range
(Red 22-18, Blue 16-14).
Insulated connectors shall be UL Listed and CSA Certified for 600 V building wire:
1000 V signs or lighting fixtures (luminaires) and temperature rated 221˚F (105˚C)
maximum.
Female Disconnects shall be suitable for field or factory wiring, with a UL
Recognized strain relief required.
2 of 3
3M™ Scotchlok™ Terminals MNG18-250DFI, MNG14-250DFI
Shelf Life &
Storage
Availability
3M™ Scotchlok™ Terminals MNG18-250DFI and MNG14-250DFI have a 5-year shelf life
from date of manufacture when stored in a humidity controlled storage (10°C/50°F to
27°C/80°F and
很抱歉,暂时无法提供与“MNG14-250DFIX”相匹配的价格&库存,您可以联系我们找货