4
3
2
1
NOTES
1. DIMENSIONS ARE IN MILLIMETERS.
3MTM TWIN AXIAL CABLE, SL8800 SERIES
2. PHYSICAL:
COLOR: SILVER
MARKING:
3M (part number) 30 AWG (signal
plating) [VW1] (lot code)
EXAMPLE:
3M SL8801/12-10DA5-00 30 AWG
SILVER TW602-1
D
15.60
EXAMPLE VW1:
3M SL8801/12-1FDG5-00 30 AWG
SILVER VW1 TW602-1
7.08
C
6.52
3. REGULATORY INFORMATION:
ROHS COMPLIANT. SEE THE
REGULATORY INFORMATION APPENDIX
(RIA) IN THE "ROHS COMPLIANCE"
SECTION OF WWW.3MCONNECTORS.COM
FOR COMPLIANCE INFORMATION
(RIA E1 & C1 APPLY)
4.95
C
2.58
+.25
1 1.00
-.00
C
THIS CABLE CONSTRUCTION HAS A THIN
ALUMINUM LAYER AT EACH EDGE. USER
SHOULD EVALUATE ITS USE IN THEIR
APPLICATION AND, IF NECESSARY,
INSULATING TAPE MAY BE APPLIED TO
COVER THE ALUMINUM LAYER, AS USER
DEEMS APPROPRIATE.
0.038
SIGNAL WIRES:
30 AWG SOLID (
0.254 [.0100])
SILVER OR TIN PLATED COPPER
0.787 [.0310]
POLYOLEFIN INSULATION
8 PLACES
0.56
3 PLACES
GROUND WIRES:
30 AWG SOLID (
0.254 [.0100])
TIN PLATED COPPER
2 PLACES
6.
C
DENOTES CRITICAL DIMENSION.
SIDEBAND WIRES:
30 AWG SOLID (
0.254 [.0100])
TIN PLATED COPPER
0.558 [.0220]
POLYOLEFIN INSULATION
4 PLACES
B
B
E
79896
AUG 07,2018
LDS MML
ADDED CRITICAL DIM
SYMBOLS
ADDED NOTE 6
REVISED TOLERANCE
1
A
SIGNAL WIRE
PLATING
SILVER
TIN
DESIGN REFERENCE
HORIZONTAL FLAME
VERSION
VW1 VERSION
SL8801/12-10DA5-00
SL8801/12-1FDG5-00
SL8801/12-11DA5-00
PRODUCT SPEC.
IMPEDANCE SPEC.
PS-0105
100
SL8801/12-1GDG5-00
NEXT ASSEMBLY
ACCESS
CODES
DIVISION
95
SCALE
15
1
5 OHMS
THIRD ANGLE PROJECTION
INTERPRET PER
ASME Y14.5 - 2009
MAX SURFACE ROUGHNESS
Visit http://www.3mconnectors.com
125
ALL SURFACES
MARKED ONLY
4
3
ECO
ISSUE DATE AND DESCRIPTION
DRFT
DATE
MWL
MAR 04,2011
CHKD
DATE
RE
MAR 04,2011
DIVISION CODE
PS-0163
5 OHMS
REV
C
3M Center
DO NOT
SCALE
DRAWING
2
E
5. FOIL AND INSULATOR STRIPPING
BLADE DESIGN DRAWINGS ARE
AVAILABLE UPON REQUEST.
TOOLING REFERENCE NUMBER: NU6D
Imaged: Central Standard Time 8/7/2018 -- UTC Offset (hrs) 6
0.79
4 PLACES
C
C
DRAWING NUMBER
2.81
C
78-5100-2412-4
4. THE OUTER SURFACE OF THE RIBBON
CABLE HAS A METALLIC APPEARANCE,
BUT IS NOT CONDUCTIVE. THERE IS
A TRANSLUCENT POLYESTER OUTER
LAYER OVER AN ALUMINUM SHIELDING
LAYER, WHICH GIVES THIS
APPEARANCE.
REVISION
UL FILE NUMBER: E42769
5.18
2 PLACES
0.874
D
St. Paul,
TOLERANCES
EXCEPT AS
NOTED
INCHES
.0
.00
.000
.0000
MILLIMETERS
0
.0
.00
0.10
.000
ANGLES
1
MN
55144
DRFT
MFG
DATE
APPVL
DATE
CHKD
3M COPYRIGHT 2018
This document and the information it contains are
3M property and may not be reproduced or further
distributed without 3M permission, or used or
disclosed other than for 3M authorized purposes.
All rights reserved.
TITLE
SL8801/12-1XDX5-00,
100 OHM, 30 AWG, 4PR,
4SBC
CAGE SIZE
NUMBER
MODEL
DRAWING NO.
REV.
78-5100-2412-4
DET.
LISTS
1
YES
NO
E
SHT 1 OF 2
A
4
3
2
1
D
D
Regulatory: For regulatory information about this product, visit 3M.com/regs
or contact your 3M representative.
Technical Information: The technical information, recommendations and other
statements contained in this document are based upon tests or experience that
3M believes are reliable, but the accuracy or completeness of such information
is not guaranteed.
E
C
78-5100-2412-4
DRAWING NUMBER
Warranty, Limited Remedy, and Disclaimer: Unless an additional warranty is
specifically stated on the applicable 3M product packaging or product literature,
3M warrants that each 3M product meets the applicable 3M product specification at
the time 3M ships the product. 3M MAKES NO OTHER WARRANTIES OR CONDITIONS,
EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OR
CONDITION OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR ANY IMPLIED
WARRANTY OR CONDITION ARISING OUT OF A COURSE OF DEALING, CUSTOM OR USAGE OR TRADE.
If the 3M product does not conform to this warranty, then the sole and exclusive
remedy is, at 3M's option, replacement of the 3M product or refund of the purchase
price.
Limitation of Liability: Except where prohibited by law, 3M will not be liable for
any loss or damage arising from the 3M product, whether direct, indirect, special,
incidental or consequential, regardless of the legal theory asserted, including
warranty, contract, negligence or strict liability.
B
B
3M Electronics Materials Solutions Division
6801 River Place Blvd.
Austin, TX 78726-9000
1-800-225-5373
www.3M.com/interconnect
E
79896
AUG 07,2018
LDS MML
ADDED CRITICAL DIM
SYMBOLS
ADDED NOTE 6
REVISED TOLERANCE
1
DESIGN REFERENCE
NEXT ASSEMBLY
ACCESS
CODES
DIVISION
REV
ECO
ISSUE DATE AND DESCRIPTION
DRFT
DATE
MWL
MAR 04,2011
CHKD
DATE
RE
MAR 04,2011
DIVISION CODE
C
3M Center
DO NOT
SCALE
DRAWING
A
SCALE
1
1
THIRD ANGLE PROJECTION
INTERPRET PER
ASME Y14.5 - 2009
MAX SURFACE ROUGHNESS
125
ALL SURFACES
MARKED ONLY
4
3
Imaged: Central Standard Time 8/7/2018 -- UTC Offset (hrs) 6
C
REVISION
Product Use: Many factors beyond 3M's control and uniquely within user's control
can affect the use and performance of a 3M product in a particular application.
Given the variety of factors that can affect the use and performance of a
3M product, user is solely responsible for evaluating the 3M product and
determining whether it is fit for a particular purpose and suitable for user's
method of application.
2
St. Paul,
TOLERANCES
EXCEPT AS
NOTED
INCHES
.0
.00
.000
.0000
MILLIMETERS
0
.0
.00
0.10
.000
ANGLES
1
MN
55144
DRFT
MFG
DATE
APPVL
DATE
CHKD
3M COPYRIGHT 2018
This document and the information it contains are
3M property and may not be reproduced or further
distributed without 3M permission, or used or
disclosed other than for 3M authorized purposes.
All rights reserved.
TITLE
SL8801/12-1XDX5-00,
100 OHM, 30 AWG, 4PR,
4SBC
CAGE SIZE
NUMBER
MODEL
DRAWING NO.
REV.
78-5100-2412-4
DET.
LISTS
1
YES
NO
E
SHT 2 OF 2
A