Specialty Terminals
W
SS-31-4 thru SS-33-14
Locking Fork, Non-Insulated, Butted Seam
C
E
Data Sheet
Product
Number
Wire
Range
(AWG)
Stud
Size
Max
Lock
Width
W
C
L
E
Thickness
Barrel
Length
Barrel
I.D.
SS-31-4
22-18
4
0.27
0.25
0.25
0.68
0.50
0.030
0.25
0.070
SS-31-6
22-18
6
0.27
0.25
0.25
0.68
0.50
0.030
0.25
0.070
SS-31-8
22-18
8
0.34
0.30
0.25
0.68
0.50
0.030
0.25
0.070
SS-31-10
22-18
10
0.35
0.32
0.25
0.68
0.50
0.030
0.25
0.070
SS-32-4
16-14
4
0.27
0.25
0.25
0.68
0.50
0.030
0.25
0.090
SS-32-6
16-14
6
0.27
0.25
0.25
0.68
0.50
0.030
0.25
0.090
SS-32-8
16-14
8
0.34
0.30
0.25
0.68
0.50
0.030
0.25
0.090
SS-32-10
16-14
10
0.35
0.32
0.25
0.68
0.50
0.030
0.25
0.090
SS-32-14
16-14
1/4
0.48
0.43
0.40
0.90
0.65
0.030
0.25
0.090
SS-33-6
12-10
6
0.30
0.28
0.28
0.73
0.53
0.040
0.25
0.135
SS-33-8
12-10
8
0.35
0.32
0.28
0.73
0.53
0.040
0.25
0.135
SS-33-10
12-10
10
0.36
0.32
0.28
0.73
0.53
0.040
0.25
0.135
SS-33-14
12-10
1/4
0.48
0.43
0.44
0.94
0.69
0.040
0.25
0.135
Installation Information
WARNING
LISTED 314R
UNDERWRITERS
LABORATORIES
STANDARD NO. UL 486A
3M FILE NO. E23438
CANADIAN STANDARDS
ASSOCIATION
STANDARD NO. C22.2
NO. 0. 65
3M FILE NO. LR22190
UL Listed and CSA Certified for use on stranded copper
(AWG) wire only.
Strip away the end 3/8 inch of wire insulation.
Specifications
Wire Size:
Barrel Seam:
Max. Current:
Terminal Material:
Plating:
Turn power off before installing or removing terminal. All electrical
work should be done according to appropriate electrical codes.
See Table Above
Butted
Same as Wire
ETP Copper
Tin
Make the crimp in the proper station of a recommended
3M crimp tool: TH-440, TH-450 (scissor style), or
TR-490 (ratchet style) hand tools.
Barrel Crimp (Required)
L
Engineering Specification
Crimp-type terminals shall, electrically and
mechanically, connect to a pre-stripped end of a
stranded copper wire and have a flat tongue portion
with a central opening for mounting around a screw or
stud.
The terminal line shall offer tongue variations in hole
(stud) size (6, 8 10, etc.) and configuration (ring, fork,
block fork, flanged block fork, locking fork, etc.): and
barrel variations in wire (AWG) size (22-18, 16-14,
12-10, etc.) and construction (non-insulated brazed
seam, vinyl insulated butted seam, nylon insulated with
insulation grip, etc.). The terminal line shall have
regulatory agency coverage (UL Listing, CSA
Certification). The terminal tongue shall be marked
with the wire range and manufacturer’s symbol ().
The non-insulated, butted seam locking fork terminal
shall be tin-plated, annealed copper, with the tongue
having a specified stud slot (size 4 thru 1/4 in.) and a
butted seam barrel with a beveled I.D. for ease of
stranded wire entry, sized for a specified (AWG) wire
range (22-18, 16-14, 12-10).
Non-insulated terminals shall be UL Listed and CSA
Certified.
3M is a trademark of 3M.
is a trademark of Underwriters Laboratories.
is a trademark of Canadian Standards Association.
IMPORTANT NOTICE
Before using this product, you must evaluate it and determine if it is suitable for your intended application. You assume all risks and liability
associated with such use.
Warranty; Limited Remedy; Limited Liability. This product will be free from defects in material and manufacture as of the date of purchase.
3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE. If this product is defective within the warranty period stated above, your exclusive remedy shall be,
at 3M’s option, to replace or repair the 3M product or refund the purchase price of the 3M product. Except where prohibited by law, 3M will
not be liable for any loss or damage arising from this 3M product, whether direct, indirect, special, incidental or consequential
regardless of the legal theory asserted.
Electrical Products Division
6801 River Place Blvd.
Austin, TX 78726-9000
http://www.3M.com/elpd
Litho in USA.
© 3M 2002 78-8126-0863-2-A