Splice Rejacketing
387
Splice Repair
390
3 M Safety Sock Grounding Kits,
Shielded and Jacketed URD Cable
391
Sealing and Grounding
393
3/C Cable Breakout Boots and
3/C Phase Rejacketing System
395
Insulating and Sealing Compounds
408
Mounting Brackets
410
3M Cold Shrink Corrosion Protection Kit
CPT Series
411
Preparation and Cleaning
413
3M Electrostatic Animal Guard
415
Overhead Conductor Animal Guard Cover
416
CABLE ACCESSORY PRODUCTS
Cable
Accessory
Products
™
™
™
Offers accessory products to assist with splice rejacketing,
cable jacket sealing, grounding and cable preparation.
Many of the products shown here are used with 3M splices
and terminations. Remember to reference those sections for
more product information.
Complete care
for any
kind of cable
FAX 800-245-0329
386
Splice Rejacketing
When jacketed concentric neutral cable (JCN) is spliced,
it is necessary to cover the junction between the cable jackets
with a water resistant rejacket. 3M offers three designs for
splice rejacketing: cold shrink one piece sleeve, cold shrink
stacked sleeve, and heat shrink adhesive-lined sleeves.
3M Cold Shrink Splice Jacket Kits
SJ-1A, SJ-2A, SJ-3A
™
Cold shrink jacket kits offer advanced, one-piece, watertight rejacketing for JCN cable splices. Designed as an
accessory kit to re-jacket over molded rubber splices,
the SJ Series is made from durable EPDM rubber.
3M Cold Shrink jacket kits SJ-1A, SJ-2A and SJ-3A offer
advanced, one-piece, water-tight rejacketing for JCN
shielded power cable splices. The SJ series accommodates
voltage classifications of 15 kV, 25 kV and 35 kV.
In addition to the open-ended, tubular rubber sleeve,
each kit includes Scotch Rubber Mastic Tape, which is
used to adjust cable O.D. and provide a sure, long-lasting
seal between the cable jacket and the cold shrink sleeve,
as well as sealing around the cable ground conductor.
®
This unique, cold shrink rejacketing kit eliminates the need
for dangerous torches or special tooling.
Each kit jackets one splice.
3M Cold Shrink SJ-SS Series Stacked
Sleeve Splice Jacket Kits SJ-1SS,
SJ-2SS, SJ-3SS
™
Cold Shrink Jacket Kits SJ-1SS, SJ-2SS and SJ-3SS are
two-piece, water tight rejacketing kits for JCN cables.
3M Heat Shrinkable Splice Jacket Kits HSJ Series
™
Designed to rejacket molded rubber splices, the SJ-SS
Series kits are made of EPDM rubber. This unique twopiece design allows the two tubes to “stack" on top of
each other during installation, requiring less space in the
manhole or ditch to make the splice. Each kit contains
one small cold shrink tube, one large cold shrink tube, one
profile bushing and one roll of Scotch Mastic Tape 2228.
SJ-1SSR and SJ-2SSR are specially sized for repair splices.
®
Each kit jackets one splice.
3M Cold Shrink Foldback
Splice Jacket Kits SJ-FB
™
3M Cold Shrink Foldback Splice Jacket Kits SJ-FB Series
are a series of folded back, tubular rubber sleeves that
combined with Scotch Rubber Mastic Tape 2228 provide
a sealed jacket over cable splices installed on jacketed
power cable. These kits are similar to the FB tubes in the
3M Cold Shrink QS III splice kits.
®
The Scotch Rubber Mastic Tape 2228 provides for an
assured sealing interface between the cable jacket and Cold
Shrink Foldback Jacket Tube. Mastic strips are also used
to seal around the optional, external ground conductor.
The jacketing tube is made from EPDM rubber that contains
no chlorides or sulfurs. The completed jacket tube will be
continuous from cable jacket to cable jacket, with no seams.
Four kit sizes cover an application range from 4 AWG,
15 kV to sizes larger than 4/0 AWG, 35 kV.
3M Heat Shrinkable Splice Jacket Kits
HSJ Series
™
3M Cold Shrink SJ-SS Series Stacked Sleeve Splice Jacket Kits SJ-1SS,
SJ-2SS, SJ-3SS
™
HSJ Series Heat Shrinkable Splice Jackets are adhesive
lined for water-tight rejacketing of JCN cable splices.
Each kit covers one splice.
387
PHONE 800-245-3573
• To jacket inline splices installed on JCN cable and
other jacketed power cables with continuous operating
temperature of up to 105º C and an emergency overload
temperature rating up to 140º C
• Physical protection and moisture sealing of inline
splices installed on shielded power cables having a solid
dielectric insulation
• For use in indoor or outdoor installations including direct
burial, aerial, and submersible applications
Jacketed Concentric Neutral Cable (JCN)
Specifications and Ordering Information for 3M Splice Jacket Kits
™
Splice Kit Product No.
Product
Number
UPC
(054007-)
Sleeve
Length
Expanded
Sleeve I.D.
Min. Cable
Jacket O.D.
Max. Cable
Max. Cable
Splice O.D. Jacket Opening
15 kV
25 kV
35 kV
Case
Qty.
3M Cold Shrink SJ Series Jacket Kits for 15 kV, 25 kV and 35 kV
SJ-1A
69742
28"
(711,2 mm)
2.7"
(68,5 mm)
0.95"
(24,1 mm)
2.4"
(61,0 mm)
20"
(508 mm)
5411
5411A
5411R*
5412
—
—
6
SJ-2A
69743
36"
(914,4 mm)
3.7"
(93,9 mm)
1.15"
(29,2 mm)
3.3"
(83,8 mm)
28"
(711 mm)
5403
5404
5405
5406
5420
5421
5422
5451
5451A
5452
5432
5461
6
SJ-3A
69744
38"
(965,2 mm)
4.3"
(109,2 mm)
1.55"
(39,4 mm)
4.0"
(101,6 mm)
30"
(762 mm)
5407
5408
5409
5423
5424
5425
5426
5433
6
CABLE ACCESSORY PRODUCTS • Splice Rejacketing
Applications:
3M Cold Shrink SJ-FB Series Jacket Kits for 15 kV, 25 kV and 35 kV
SJ-1FB
55302
—
—
0.95"
(24,1 mm)
2.00"
(50,8 mm)
25"
(63,5 mm)
5411
5411A
5412
—
—
6
SJ-2FB
55303
—
—
1.15"
(29,2 mm)
3.00"
(76,2 mm)
31"
(78,7 mm)
5403
5404
5405
5406
5420
5421
5422
5451
5451A
5452
5432
5461
6
SJ-3FB
55304
—
—
1.55"
(39,4 mm)
3.62"
(91,9 mm)
34"
(86,4 mm)
5407
5408
5409
5423
5424
5425
5426
5433
6
SJ-4FB
55305
—
—
1.75"
(44,5 mm)
4.10"
(104,1 mm)
32"
(81 mm)
—
—
—
6
5411
5411A
5412
—
—
6
Note: The above dimensions should be used to determine sizing for non-3M splices.
3M Cold Shrink SJ-SS Series Cold Shrink Stacked Sleeve Kits for 15 kV, 25 kV and 35 kV
SJ-1SS
50777
15"
(381,0 mm)
18"
(457,2 mm)
2.4"
(60,9 mm)
3.1"
(78,7 mm)
0.95"
(24,1 mm)
2.4"
(61,0 mm)
23"
(584 mm)
*3M 5411R QS-II requires an additional 8428-12 Cold Shrink tube to jacket the splice. The procedure for jacketing the 5411R QS-II is detailed in the SJ-1A kit
installation instructions.
FAX 800-245-0329
388
Specifications and Ordering Information for 3M Splice Jacket Kits
™
Splice Kit Product No.
Product
Number
UPC
(054007-)
Sleeve
Length
Expanded
Sleeve I.D.
Min. Cable
Jacket O.D.
Max. Cable
Max. Cable
Splice O.D. Jacket Opening
SJ-2SS
50778
19"
(482,6 mm)
24"
(609,6 mm)
3.1"
(78,7 mm)
3.7"
(93,9 mm)
1.15"
(29,2 mm)
3.3"
(83,8 mm)
SJ-3SS
50779
22"
(558,8 mm)
25"
(635,0 mm)
3.7"
(93,9 mm)
4.3"
(109,2 mm)
1.55"
(39,4 mm)
Case
Qty.
15 kV
25 kV
35 kV
31"
(787 mm)
5403
5404
5405
5406
5420
5421
5422
5451
5451A
5452
5432
5461
6
4.0"
(101,6 mm)
35"
(889 mm)
5407
5408
5409
5423
5424
5425
5426
5433
6
3M Cold Shrink Stacked Sleeve Repair Jacket Kits for 15 kV
SJ-1SSR
41956
—
—
0.95"
(25 mm)
1.95"
(49,5 mm)
29"
(737 mm)
5411R
—
—
6
SJ-2SSR
41957
—
—
1.15"
(29,2 mm)
3.00"
(76,2 mm)
37"
(940 mm)
5412R
5451R
—
—
6
3M HSJ Series Heat Shrinkable Splice Jackets for 15 kV, 25 kV and 35 kV
HSJ-1
09270
33"
(84 mm)
2.5"
(64 mm)
0.85"
(21,6 mm)
1.9"
(48,3 mm)
22"
(559 mm)
5411
5411A
5411R
5412
—
—
10
HSJ-2
09271
40"
(102 mm)
3.0"
(76 mm)
1.00"
(25,4 mm)
2.6"
(66,0 mm)
28"
(711 mm)
5403
5404
5405
5406
5412R
5420
5421
5422
5451
5451A
5451R
5452
5432
5461
10
HSJ-3
09272
40"
(102 mm)
4.3"
(109 mm)
1.50"
(38,1 mm)
3.4"
(86,4 mm)
28"
(711 mm)
5407
5408
5409
5423
5424
5425
25426
5433
5
*3M 5411R QS-II requires an additional 8428-12 Cold Shrink tube to jacket the splice. The procedure for jacketing the 5411R QS-II is detailed in the SJ-1A kit
installation instructions.
Kit Contents for 3M Splice Jacket Kits
Product Number
SJ-1A
SJ-2A
SJ-3A
Cable Type
SJ-1SS
SJ-2SS
SJ-3SS
HSJ-1
HSJ-2
HSJ-3
Jacketed Concentric Neutral Cable (JCN)
See page 385 for cable type illustration.
Each kit jackets one splice
Cold Shrink Jacketing
Cold Shrink Tube
1
1
1
2
2
2
—
—
—
Scotch Rubber Mastic
Tape 2228
1
1
1
1
1
1
—
—
—
Heat Shrink Tube
—
—
—
—
—
—
1
1
1
Profile Bushing
—
—
—
1
1
1
—
—
—
Instructions
1
1
1
1
1
1
1
1
1
®
389
Heat Shrink Jacketing
PHONE 800-245-3573
CABLE ACCESSORY PRODUCTS • Splice Repair
Splice Repair
3M HDCW Wraparound
Heat Shrink Cable Repair Sleeves
™
3M HDCW Heat Shrink Wraparound Cable Repair Sleeves
are designed to quickly repair damaged cable jacketing.
They may also be used to rejacket in-line splices. 3M
HDCW wrap sleeves can be used as insulation material
on cable and splices up to 1000 volts and as jacket repair
material on cable up to 35 kV. The design of the wrap
sleeve allows it to be installed in tight spaces with ordinary
heating equipment such as a torch.
The 3M HDCW cable repair is made from modified
cross-linked polyolefin, with a hot-melt adhesive liner
on the inner side of the sleeve. Upon heating, the sleeve
shrinks and the adhesive melts, creating a water-tight bond
between the sleeve and the cable. 3M HDCW Wraparound
Cable Repair Sleeves meet ANSI C119.1 requirements.
A corrosion proof metal channel is used to close the
sleeve during installation.
3M HDCW wrap sleeves are stocked in four lengths and
five diameters. Other cut lengths are available upon request.
Application Guide and Ordering Information for
3M HDCW Wraparound Heat Shrink Cable Repair Sleeves
Sleeve Dimensions
UPC
(051138-)
Length
in. (mm)
600/1000V
Conductor Size
(AWG or MCM)
Jacket Repair
Use Range
Max./Min.
in. (mm)
HDCW 35/10-250
HDCW 35/10-1200
48416
48436
9.8" (250 mm)
47.2" (1200 mm)
#8-2/0
#8-2/0
1.38-0.39" (35-10 mm)
1.38-0.39" (35-10 mm)
1.97" (50 mm)
1.97" (50 mm)
0.32" (8 mm)
0.32" (8 mm)
HDCW 55/15-500
HDCW 55/15-1200
48421
48437
19.7" (500 mm)
47.2" (1200 mm)
3/0-400
3/0-400
2.17-0.59" (55-15 mm)
2.17-0.59" (55-15 mm)
2.95" (75 mm)
2.95" (75 mm)
0.51" (13 mm)
0.51" (13 mm)
HDCW 80/25-750
HDCW 80/25-1200
48426
48438
29.5" (750 mm)
47.2" (1200 mm)
500-1000
500-1000
3.15-0.98" (80-25 mm)
3.15-0.98" (80-25 mm)
3.94" (100 mm)
3.94" (100 mm)
0.91" (23 mm)
0.91" (23 mm)
HDCW 110/30-1000
HDCW 110/30-1200
48431
48439
39.4" (1000 mm)
47.2" (1200 mm)
1000-2000
1000-2000
4.33-1.18" (110-30 mm)
4.33-1.18" (110-30 mm)
5.20" (132 mm)
5.20" (132 mm)
0.98" (25 mm)
0.98" (25 mm)
HDCW 140/40-1000
HDCW 140/40-1200
48435
48440
39.4" (1000 mm)
47.2" (1200 mm)
N/A
N/A
5.39-1.38" (137-35 mm)
5.39-1.38" (137-35 mm)
5.71" (145 mm)
5.71" (145 mm)
1.26" (32 mm)
1.26" (32 mm)
Part Number
Expanded
Diameter
in. (mm)
Reserved
Diameter
in. (mm)
FAX 800-245-0329
390
3M Safety Sock
Grounding Kits, Shielded
and Jacketed URD Cable
™
For use on tape or wire shield and jacketed concentric
neutral (JCN) cables. Provides continuity of the cable shield
system and a path to ground in the event of a dig-in.
Ordering Notes:
• Each kit contains shielding for one splice
• Use the shield diameter range as final ordering criteria
• A rejacketing sleeve, such as the 3M Ground Kits
SJ Series, must be applied over shielding
• Kit contents: copper screen sleeve, mastic seal strips,
constant-force springs, instructions
Specifications and Ordering Information for 3M Safety Sock Series Grounding Kits
™
UPC
(051141-)
Cable Size
Shield Diameter Range
Case Qty.
SS-A
40745
—
0.47-0.78"
(12-20 mm)
—
SS-1
15555
#2-3/0
0.78-1.47"
(20-37 mm)
1
SS-2
15561
#4/0-500 kcmil
1.0-2.20"
(25-56 mm)
1
SS-3
15557
500-1250 Kcmil
1.5-2.93"
(38-74 mm)
1
SS-4
40455
—
1.77-4.21"
(45-107 mm)
—
Product Number
These kits are available in Canada only.
391
PHONE 800-245-3573
™
™
Scotchcast Jacket Repair Kits M Series contain a reusable
wrap-around mold and accessory materials needed to make
10 permanent, flexible and moisture-resistant jacket repairs
or splices of portable cable. The kit contains a wrap around
mold that permits jacket repair without cutting through the
cable. When used with 3M Scotchcast Resin 2130, M series
kits provide durable, flexible jacket repair. Scotchcast kits
can be used with portable power cable or standard cable.
Note: Scotchcast flame-retardant compound 2130 needed
to jacket the repair or splice is not included and must
be ordered separately. U.S. Mine Safety and Health
Administration acceptance No. P-142-5 MSHA.
3M Scotchcast Jacket Repair Kits M Series
™
™
Specifications and Ordering Information for
3M Scotchcast Jacket Repair Kits M Series
Product Number
M-20
M-30
M-40
Cable Diameter Range
1.60-2.5"
(41-64 mm)
1.85-4.0"
(47-102 mm)
1.85-6.0"
(47-152 mm)
Maximum Repair Length
13-15"
(33-38 cm)
20"
(51 cm)
32"
(81 cm)
31392
31393
31394
1 kit
1 kit
1 kit
Ordering Information
UPC (054007-)
Case Qty.
It’s all
about
quality control
FAX 800-245-0329
CABLE ACCESSORY PRODUCTS • 3M™ Safety Sock Grounding Kits, Shielded and Jacketed URD Cable
3M Scotchcast Jacket
Repair Kits M Series
392
Sealing and Grounding
3M Cold Shrink Cable Accessory Sealing Kits 8450
Series are designed to seal the end of JCN cable. Use these
kits when installing elbows or other cable accessories that
do not include a jacket seal. 3M also offers three types of
sheath sealing or breakout kits; poured resin, cold shrink
and heat shrink, several heat shrink cable sealing end caps
and a variety of grounding hardware.
™
3M Cold Shrink Cable Accessory
Sealing Kits 8450 Series
™
The 3M Cold Shrink Cable Accessory Sealing Kits 8450
Series are designed to seal the jacket end of power cables
where elbows or other cable accessories are installed. Both
the sealing tube and mastic are compatible with commonly
used power cable jacketing and semiconductive materials.
Note: Elbow not included.
Jacketed Concentric Neutral Cable (JCN)
Specifications and Ordering Information for
3M Cold Shrink Cable Accessory Sealing Kits 8450 Series
Product Number
8452
Cable Type
8452L
8453
8454
Jacketed Concentric Neutral Cable (JCN)
See above for cable type illustration.
Cable Size/Volt Class:
Cable Size for 15 kV Class
2-4/0 AWG
(35-100 mm2)
2-4/0 AWG
(35-100 mm2)
2/0 AWG-1000 kcmil
(70-500 mm2)
750-1500 kcmil
(380-725 mm2)
Cable Size for 25 kV Class
2-2/0 AWG
(35-50 mm2)
2-2/0 AWG
(35-50 mm2)
1/0 AWG-750 kcmil
(60-380 mm2)
600-1250 kcmil
(325-625 mm2)
Cable Size for 35 kV Class
1/0 AWG
(60 mm2)
1/0 AWG
(60 mm2)
1/0 AWG-500 kcmil
(60-250 mm2)
350-1000 kcmil
(180-500 mm2)
Minimum Seal Diameter
0.95" (24 mm)
0.95" (24 mm)
1.28" (33 mm)
1.60" (41 mm)
Maximum Installed Diameter
1.94" (49 mm)
1.94" (49 mm)
2.67" (68 mm)
3.50" (89 mm)
1
1 (1/2" longer)
1
1
3 strips
3 strips
4 strips
6 strips
1
1
1
1
UPC (054007-)
08336
44312
09676
49938
Inner Unit Pack
1/bag
—
1/bag
—
Case Qty.
10 kits
10 kits
10 kits
10 kits
Kit Components:
Cold Shrink Sealing Tube
Mastic Sealing Strips
6" (152,4 mm)
Instructions
Ordering Information
393
PHONE 800-245-3573
™
Tape Shielded
3M Cold Shrink Shield Adapter Kits are designed for
grounding and sealing tape, wire and UniShield shielded
power cables when using cable accessories such as elbows,
modular splices and terminations.
Wire Shielded
These cold shrink kits require no heat, special tools or
special skills to install. The cold shrink kits come complete
with all necessary components (except the cable accessory)
and are installed in a few simple steps. We’ve even attached
a “bleeder wire” to the ground strap eliminating the need
for additional wire and connectors.
UniShield
®
Specifications and Ordering Information for
3M Cold Shrink Shield Adapter Kits 8459/8460 Series
Product Number
8459
Cable Type
8460
8461
8462
Tape Shielded, Wire Shielded, Unishield
See above for cable type illustration.
®
Jacket O.D. Range
Inches (mm)
0.59-1.05
(15,0-26,6)
0.83-1.64
(21,1-41,6)
1.27-2.17
(32,3-55,1)
1.70-2.60
(43,2-66,0)
Cable Size for 5/8 kV Class
8-1 kcmil
(10-38 mm2)
1/0 AWG-350 kcmil
(50-200 mm2)
500-1000 kcmil
(240-500 mm2)
—
Cable Size for 15 kV Class
—
2-250 kcmil
(35-150 mm2)
350-1000 kcmil
(185-500 mm2)
1250-1750 kcmil
(600-850 mm2)
Cable Size for 25 kV Class
—
2-250 kcmil
(35-150 mm2)
350-750 kcmil
(185-500 mm2)
1000-1500 kcmil
(600-725 mm2)
Cable Size for 35 kV Class
—
2-1/0 kcmil
(35-60 mm2)
2/0 AWG-350 kcmil
(70-200 mm2)
500-1000 kcmil
(240-500 mm2)
Cable Size/Volt Class:
CABLE ACCESSORY PRODUCTS • Sealing and Grounding
3M Cold Shrink Shield Adapter Kits
8459/8460 Series
Kit Components:
Cold Shrink Sealing Tube
1
1
1
1
Mastic Sealing Strips 6"
(152,4 mm)
3 strips
3 strips
3 strips
3 strips
Constant Force Spring
1
1
1
1
Preformed Ground Braid/
Bleeder Wire
1
1
1
1
1 strip
1 strip
1 strip
1 strip
1
1
1
1
UPC (054007-)
53236*
41458
41459
53131*
Inner Unit Pack
1/bag
1/bag
1/bag
1/bag
Case Qty.
3 kits
3 kits
3 kits
3 kits
Scotch 13
Semi-Conductive Tape
®
Instructions
Ordering Information
* UPC 051128-
FAX 800-245-0329
394
3/C Cable Breakout
Boots and 3/C Phase
Rejacketing System
3M Cold Shrink Silicone Rubber 3/C Cable Breakout
Boots 8560 Series and 3M Silicone Rubber RJS Series
3/C Phase Rejacketing Systems are designed to be used
in conjunction with 3M terminations, to seal the breakout
area and rejacket the phases on three conductor cable
without grounds.
™
3M Cold Shrink Silicone Rubber 3/C
Cable Breakout Boots 8560 Series
™
3M Silicone Cold Shrink Cable Breakout Boots 8561
through 8565 are a series of open-ended molded rubber
sealing assemblies that are factory expanded and mounted
on removable inner-supporting plastic cores. They are
supplied for field installation in a pre-stretched condition.
3M QT-III Silicone Rubber
™
Features and Benefits:
The supporting cores are removed after the seal has been
positioned for installation around the breakout area of a
three conductor cable. Core removal allows the silicone
rubber boot to shrink down to a predetermined diameter,
creating an environmental enclosure for individual cable
phase legs and the overall cable jacket.
• Versatile; installs quickly and accommodates
a wide range of cable sizes
3M Breakout Boots 8560 Series are designed to protect the
phase leg breakout of 3/C medium voltage power cable from
exposure to moisture, contamination, corrosion, ozone,
ultra-violet radiation, physical contact and other hazards
associated with 3/C termination operating environments.
3M Breakout Boots 8560 Series can be used in conjunction
with 3M Silicone Rubber Cold Shrink Rejacketing Sleeves
for 3/C shielded power cable terminating applications.
• No specific user skills or craftsmanship required
• Simple hand application; no need for special
installation tools
• No torches or heat required
• Excellent resistance to ozone and ultra-violet radiation
• High dry and wet insulation resistance
• Highly flexible; accommodates all power cable supplier
bend radius recommendations
• Seals tight; retains resiliency and pressure even after
prolonged years of aging and exposure
• Compatible with all 3M Cold Shrink Termination
Products and RJS Series Phase Rejacketing Sleeves
395
PHONE 800-245-3573
Features and Benefits:
™
3M RJS Series Rejacketing Sleeves are designed so that
3M Cold Shrink QT-III and Q-TIII Silicone Rubber
Terminations can be used on 3/C (three conductor) medium
voltage shielded power cables of tape shield, wire shield,
armored and non-armored configurations. RJS Rejacketing
Assemblies are a series of silicone rubber insulators
incorporating an inner-expandable polyester braid designed
to reduce sliding friction and deliver the insulator onto the
cable. Rejacketing sleeves are designed to protect the phase
legs (core) of 3/C shielded power cable from exposure to
moisture, corrosion, ozone, ultra-violet radiation, physical
contact and other hazards associated with termination
operating environments. Rejacketing sleeves are designed
to be used in conjunction with 3M Cold Shrink Breakout
Boots and Silicone Rubber Terminations.
• Versatile; installs quickly and accommodates
a wide range of cable sizes
• Simple hand application; no need for special
installation tools
• No torches or heat required
• No specific user skills or craftsmanship required
• Excellent resistance to ozone and ultra-violet radiation
• High dry and wet insulation resistance
• Excellent shelf life
• Easy-to-adjust sleeve length; adapts to variable
equipment connection and mounting requirements
• Compatible with 3M Cold Shrink PST Breakout Boots
and Termination Products
3M Cold Shrink Silicone Rubber 3/C Cable Breakout Boots 8560 Series
™
UPC
(054007-)
Cable Phase Shield
Diameter Range
mm (in.)
Cable Outer Jacket
Diameter Range
mm (in.)
Inner Unit Pack
Case Qty.
8561
43143
12.2-18.3 mm (0.48-0.72")
29.7-49.3 mm (1.17-1.94")
—
1/box
8562
43144
15.5-24.2 mm (0.61-0.95")
37.1-67.8 mm (1.46-2.67")
—
1/box
8563
43145
20.8-30.0 mm (0.82-1.18")
48.8-78.7 mm (1.92-3.10")
—
1/box
8564
43146
26.0-41.1 mm (1.02-1.63")
64.0-109.8 mm (2.52-4.32")
—
1/box
8565
43147
27.7-49.3 mm (1.09-1.94")
66.1-119.4 mm (2.60-4.70")
—
1/box
8566
57174*
29.8-47.9 mm (1.17-1.89")
80.7-140.2 mm (3.18-5.52")
—
1/box
Product
Number
* UPC prefix 051128-
3M 3/C Phase Rejacketing Sleeve Selection Guide—Based on Diameter Range
and Cable Conductor Size
™
Product
Number
UPC
(054007-)
Size
(feet)
Metallic Shield
Diameter Range
mm (in.)
3.3 kV
(mm)
IEC
3.3 kV
(mm)
JIS
5.0 kV
(AWG)
AEIC
6.6 kV
(mm)
IEC
6.6 kV
(mm)
JIS
8.0 kV
(AWG)
(AEIC
Inner
Unit Case
Pack Qty.
RJS-1-4FT
43098
4'
10.9-15.2 mm (0.43-0.60")
16-35
8-22
8-2
16-25
8-10
6-4
—
10
RJS-1-1FT
43099
10'
10.9-15.2 mm (0.43-0.60")
16-35
8-22
8-2
16-25
8-10
6-4
—
1
RJS-2-4FT
43100
4'
15.2-20.3 mm (0.60-0.80")
50-95
38-60
1-3/0
35-70
14-38
2-2/0
—
10
RJS-2-10FT
43101
10'
15.2-20.3 mm (0.60-0.80")
50-95
38-60
1-3/0
35-70
14-38
2-2/0
—
1
RJS-3-4FT
43102
4'
20.3-26.0 mm (0.80-1.02")
120-185
100-150
4/0-400
95-150
60-100
3/0-350
—
10
RJS-3-10FT
43103
10'
20.3-26.0 mm (0.80-1.02")
120-185
100-150
4/0-400
95-150
60-100
3/0-350
—
1
RJS-4-4FT
43104
4'
25.9-32.4 mm (1.02-1.28")
240-300
200-250
500-750
185-300
150-250
400-600
—
10
RJS-4-10-FT
43105
10'
25.9-32.4 mm (1.02-1.28")
240-300
200-250
500-750
185-300
150-250
400-600
—
1
RJS-5-4FT
43106
4'
32.5-41.1 mm (1.28-1.62")
—
300-325
800-1000
—
300-325
750-1000
—
10
RJS-5-10FT
43107
10'
32.5-41.1 mm (1.28-1.62")
—
300-325
800-1000
—
300-325
750-1000
—
1
FAX 800-245-0329
CABLE ACCESSORY PRODUCTS • 3/C Cable Breakout Boots and 3/C Phase Rejacketing System
3M 3/C Phase Rejacketing System
396
3M 3/C Phase Rejacketing Sleeve Selection Guide—Based on Diameter Range
and Cable Conductor Size
™
UPC
(054007-)
Size
(feet)
Metallic Shield
Diameter Range
mm (in.)
10 kV
(mm)
IEC
15 kV
(AWG)
AEIC
20 kV
(mm)
IEC
25 kV
(AWG)
AEIC
30 kV
(mm)
IEC
35 kV
(AWG)
AEIC
RJS-1-4FT
43098
4'
10.9-15.2 mm (0.43-0.60")
—
—
—
—
—
—
—
RJS-1-1FT
43099
10'
10.9-15.2 mm (0.43-0.60")
—
—
—
—
—
—
—
1
RJS-2-4FT
43100
4'
15.2-20.3 mm (0.60-0.80")
10-50
2-1
—
—
—
—
—
10
RJS-2-10FT
43101
10'
15.2-20.3 mm (0.60-0.80")
10-50
2-1
—
—
—
—
—
1
RJS-3-4FT
43102
4'
20.3-26.0 mm (0.80-1.02")
70-150
1/0-4/0
25-70
2-1/0
—
—
—
10
RJS-3-10FT
43103
10'
20.3-26.0 mm (0.80-1.02")
70-150
1/0-4/0
25-70
2-1/0
—
—
—
1
RJS-4-4FT
43104
4'
25.9-32.4 mm (1.02-1.28")
185-300
250-450
95-185
2/0-250
35-70
1/0-3/0
—
10
RJS-4-10FT
43105
10'
25.9-32.4 mm (1.02-1.28")
185-300
250-450
95-185
2/0-250
35-70
1/0-3/0
—
1
RJS-5-4FT
43106
4'
32.5-41.1 mm (1.28-1.62")
—
500-750
240-300
300-500
95-240
4/0-500
—
10
RJS-5-10FT
43107
10'
32.5-41.1 mm (1.28-1.62")
—
500-750
240-300
300-500
95-240
4/0-500
—
1
Product
Number
Inner
Unit Case
Pack Qty.
3M 3/C Phase Rejacketing Kits
RJK Kits for Converting 3/C Cable to Three 1/C Cables
™
Indoor/
Outdoor
Kits
Indoor Kits
Cable Metallic Shield
Diameter Range
RJK-1
RJS-2/3
0.60-0.80
1-3/0
2-2/0
1-2/0
RJK-2
RJS-3/3
0.80-1.02
4/0-400
3/0-30
1/0-4/0
RJK-3
RJS-4/3
1.02-1.28
500-750
400-600
250-450
2/0-250
RJK-4
RJS-5/3
1.28-1.62
800-1000
750-1000
500-750
300-500
5 kV
15 kV
25/28 kV
2-1/0
Kit Contents
Cold Slip
• 3M Cold Shrink breakout boot, 3M Cold Slip rejacketing
sleeves (3 four-foot lengths), provision to externally
ground at breakout boot
3M Cold slip re-jacketing sleeves incorporate an innerexpandable polyester braid designed to reduce sliding
friction and deliver the sleeve quickly onto the cable.
• 3M Cold Slip rejacketing sleeves (3 four-foot lengths)
Cold Shrink
3M Cold Shrink splicing products are designed using 3M’s
unique cold shrink delivery system. Products are supplied
pre-stretched on a removable core for efficiency and ease
of installation. All splices are pre-tested in the factory.
397
8 kV
PHONE 800-245-3573
10
™
3M offers three types of sheath sealing or breakout kits:
poured resin, cold shrink and heat shrink. 3M offers two
types of heat shrink cable sealing, caps and a variety
of grounding hardware.
3M Sheath Seal Kits 5831 and 5832
™
3M Sheath Seal Kits 5831 and 5832 are designed to seal
the sheath area for multiconductor cables with or without
ground wires. They will handle copper or aluminum
cables from #2 AWG through 500 kcmil (35-250 mm2).
For kit contents and sizing, see chart below. Each kit
makes one seal.
3M Sheath Seal Kits 5831 and 5832
™
3M Cold Shrink Sheath
Seal Kits 5841 and 5842
™
3M Cold Shrink Sheath Seal Kits 5841 and 5842 are
designed to seal the sheath area for three conductor
cables without ground wires. They will handle copper or
aluminum cable from #2 AWG through 500 kcmil (35250 mm2). No heat is required when using these kits. For
kit contents and sizing, see chart below. Each kit makes
one seal.
3M Cold Shrink Sheath Seal Kits 5841 and 5842
™
Specifications for 3M Sheath Seal Kits
Specifications
5831
5832
5841
5842
Conductor Size
2-3/0 AWG
(35-80 mm2)
4/0 AWG-500 kcmil
(120-250 mm2)
2-4/0 AWG
(35-100 mm2)
4/0 AWG-500 kcmil
(120-250 mm2)
2.6"
(66 mm)
3.75"
(95,2 mm)
—
—
Conductor Insulation O.D. Range
N/A
N/A
0.30-1.18"
(8-30 mm)
0.77-1.38"
(20-35 mm)
Cable Jacket Range
—
—
1.20-1.90"
(30-48 mm)
1.80-3.10"
(46-79 mm)
Molded Sheath Seal Body
—
—
1
1
Wraparound Mold Body
1
1
—
—
3M ScotchCast 2130
1
1
—
—
Abrasive Cloth
1
1
—
—
Scotch Vinyl Electrical Tape Super 33+
1
1
—
—
Scotch Linerless Rubber Splice Tape 130C
1
1
—
—
3M Scotchfil Electrical Insulation Putty
1
1
—
—
Instructions
1
1
1
1
Maximum Jacket or Armor O.D. Range
Kit Components:
™
™
®
®
™
CABLE ACCESSORY PRODUCTS • 3/C Cable Breakout Boots and 3/C Phase Rejacketing System
3M Sheath Seal Kits for
Multiconductor Cable
Note: Each kit makes one seal.
Ordering Information for 3M Sheath Seal Kits
Ordering Information
5831
5832
5841
5842
UPC (054007-)
12280
12281
12291
12292
1 kit
1 kit
1 kit
1 kit
Case Qty.
The final determining factor for the 5831 and 5832 is the conductor insulation O.D. and the cable jacket O.D.
The final determining factor for the 5841 and 5842 is the maximum jacket or armor diameter.
Note: Each kit makes one seal.
FAX 800-245-0329
398
3M Heat Shrinkable Cable
Breakout Boots
™
3M Heat Shrinkable HDBB Cable Breakout Boots are
designed for dependable insulating and sealing of cable
breakouts in multiconductor armored or sheathed cables
and conduit ends. 3M HDBB boots are made from flame
retardant, cross-linked polyolefin and meet the material
requirements of MIL-I-81765-1. The boots are designed
to provide excellent electrical and mechanical protection
and are supplied with an internal coating of adhesive for
reliable environmental sealing.
3M Heat Shrinkable Cable Breakout Boots
™
Specifications and Ordering Information for
3M Heat Shrinkable Cable Breakout Boots
™
Product Number
Cross Section
UPC (054007-)
Cable Entry End
(Max. to Min.)
Conductor Legs
(Max. to Min.)
Case
Qty.
HDBB-205-1-250
58793
0.80-0.37"
(20,32-9,40 mm)
0.33-0.11"
(8,38-2,79 mm)
1 each
HDBB-210-1-250
35992*
1.20-0.60"
(30,38-15,24 mm)
0.50-0.17"
(12,70-4,32 mm)
1 each
HDBB-220-1-250
46654**
1.90-0.90"
(48,26-22,86 mm)
0.75-0.30"
(19,05-7,62 mm)
1 each
HDBB-230-1-250
35993*
3.00-1.50"
(76,20-38,10 mm)
1.45-0.50"
(38,10-12,70 mm)
1 each
HDBB-310-1-250
35994*
0.90-0.36"
(2,86-9,14 mm)
0.33-0.12"
(8,38-3,05 mm)
1 each
HDBB-320-1-250
35995*
1.20-0.50"
(30,38-12,70 mm)
0.50-0.16"
(12,70-4,06 mm)
1 each
HDBB-321-1-250
35996*
1,50-0.69"
(38,10-17,53 mm)
0.65-0.18"
(16,51-4,57 mm)
1 each
HDBB-325-1-250
35997*
1.70-0.90"
(43,18-22,86 mm)
0.82-0.30"
(20,83-7,62 mm)
1 each
HDBB-335-1-250
03409*
2.40-1.40"
(60,96-35,56 mm)
1.25-0.50"
(31,75-12,70 mm)
1 each
HDBB-340-1-250
35998*
3.20-2.00"
(81,28-50,80 mm)
1.45-0.75"
(38,10-19,05 mm)
1 each
HDBB-345-1-250
58794
4.90-2.32"
(124,46-5,93 mm)
2.00-1.00"
(50,80-25,40 mm)
1 each
*UPC prefix 051135**UPC prefix 051138Note: 3M Breakout Boots are flame retardant and supplied with a factory-applied sealant. Unlined boots are available on special order. All boots are black in color.
Standard package is one and multiples of one.
399
PHONE 800-245-3573
™
Product Number
Cross Section
UPC (054007-)
Cable Entry End
(Max. to Min.)
Conductor Legs
(Max. to Min.)
Case
Qty.
HDBB-405-1-250
58795
0.90-0.43"
(22,86-10,92 mm)
0.28-0.11"
(7,11-2,79 mm)
1 each
HDBB-410-1-250
35999*
1.25-0.80"
(31,75-20,32 mm)
0.50-0.19"
(1,70-4,83 mm)
1 each
HDBB-415-1-250
58855
1.75-0.98"
(43,18-24,89 mm)
0.79-0.28"
(20,07-7,11 mm)
1 each
HDBB-420-1-250
36000*
2.35-1.00"
(59,69-2,4 mm)
1.00-0.35"
(25,40-8,89 mm)
1 each
HDBB-425-1-250
58797
2.65-1.40"
(67,31-35,56 mm)
1.20-0.53"
(30,48-13,46 mm)
1 each
HDBB-430-1-250
58798
5.25-3.00"
(133,35-76,20 mm)
1.35-0.55"
(34,29-13,97 mm)
1 each
HDBB-505-1-250
46648**
2.36-0.96"
(59,94-24,38 mm)
1.18-0.29"
(70,73-7,36 mm)
1 each
HDBB-605-1-250
36001*
2.39-1.45"
(60,71-38,10 mm)
0.80-0.35"
(20,32-8,89 mm)
1 each
*UPC prefix 051135**UPC prefix 051138Note: 3M Breakout Boots are flame retardant and supplied with a factory-applied sealant. Unlined boots are available on special order. All boots are black in color.
Standard package is one and multiples of one.
PRODUCT REFERRAL GENERATOR
Insulating.......................................................................... pg. 418
– Heat Shrinkable Tubing
Sealing
– Cold Shrink End Caps................................................ pg. 401
FAX 800-245-0329
CABLE ACCESSORY PRODUCTS • 3/C Cable Breakout Boots and 3/C Phase Rejacketing System
Specifications and Ordering Information for
3M Heat Shrinkable Cable Breakout Boots
400
3M Cold Shrink End Caps EC-Series
™
The 3M Cold Shrink End Caps EC-Series are designed
to environmentally seal and mechanically protect exposed
cable ends using no tools, mastics or tapes. Regardless of
the cable type or manufacturer, it takes only four different
end-caps to fit cable size ranges from 1.46" to 3.32"
(11,6-84,3 mm), reducing the need for additional inventory
to cover all cable sizes. The 3M Cold Shrink End Caps
EC-Series protects cables, pipes and other cylindrical
objects from exposure to moisture, contamination,
corrosion, ozone, ultra-violet radiation, physical contact
and other environmental hazards.
a factory applied adhesive lining for reliable environmental
sealing. Six different sizes accommodate a broad range
of cable diameters.
Standard Color: Black.
Expanded, As Supplied, Part
H Dia.
3M Heavy-Duty End Caps SKE
™
Fully Recovered Part (After Heating)
3M Heat Shrinkable End Caps are typically used to
seal cable ends and are designed to provide moisture,
mechanical and environmental protection. 3M SKE
end caps are for heavy-duty applications.
3M SKE end caps are manufactured from semi-rigid flame
retardant, cross-linked polyolefin. They are supplied with
P
R
W
H Dia.
J Dia.
SKE End Caps
Specifications and Ordering Information for 3M Cold Shrink End Caps EC-Series
UPC (051138-)
Use Range
Inches (mm)
Inner Unit Pack
EC-1
52440
0.46-0.82" (11,6-20,9 mm)
10/box
EC-2
52441
0.63-1.18" (15,9-30,1 mm)
10/box
EC-3
52442
1.02-1.94" (26,0-49,2 mm)
10/box
EC-4
52443
1.79-3.32" (45,5-84,3 mm)
10/box
Product Number
Specifications and Ordering Information for 3M Heavy-Duty End Caps SKE
Product
Number
UPC
(051138-)
H Dia.
Min. X
Max. R
J. Dia.
Max. R
P ±10% R
R ±10% R
W ±20% R
For Cable
Diameter
Case
Qty.
SKE 4/10
48153
0.39 (10,0)
0.16 (4,0)
0.12 (3,0)
1.32 (33,5)
1.18 (30,0)
0.08 (2,0)
0.16-0.31
(4-8)
1000 each
SKE 8/20
48154
0.79 (20,0)
0.30 (7,5)
0.26 (6,5)
2.18 (55,3)
1.97 (50,0)
0.09 (2,3)
0.31-0.43
(8-11)
250 each
SKE 15/40
48155
1.57 (40,0)
0.59 (15,0)
0.41 (10,5)
3.54 (90,0)
3.15 (80,0)
0.12 (3,0)
0.59-1.26
(15-32)
60 each
SKE 25/63
48156
2.48 (63,0)
0.98 (25,0)
0.63 (16,0)
5.63 (143,3)
5.12 (130,0)
0.13 (3,3)
1.00-1.97
(25-50)
60 each
SKE 30/76
48157
2.99 (76,0)
1.18 (30,0)
0.67 (17,0)
6.22 (158,0)
5.91 (150,0)
0,16 (4.0)
1.18-2.36
(30-60)
40 each
SKE 45/100
48158
3.94 (100,0)
1.77 (45,0)
1.02 (26,0)
6.40 (162,5)
5.50 (140,0)
0.16 (4,0)
1.77-3.15
(45-80)
30 each
NOTES:
1. All dimensions in both inches and metric. All angles in degrees.
2. Dimensions in table: X= Expanded (Minimum); R= Recovered (Maximum)
3. Color: Black
401
PHONE 800-245-3573
™
3M Hi-Amp Accessory Grounding Kit
8473 for 15 kV, 25 kV and 35 kV
™
Tape Shielded Cable
Tape Shielded Cable
LC Shielded Cable
LC Shielded Cable
3M Hi-Amp Splice Grounding Accessory Kit SG-2 and
SG-3 are designed to accommodate the shielding and
grounding of inline splices made on LC, heavy-duty tape
and conventional tape shielded power cables. The SG-2
and SG-3 designs provide a fault current capacity of 15,000
Amps for 15 cycles on 15, 25 and 35 kV class cables.
The 3M kits SG-2 and SG-3 were designed to accommodate
all 3M Quick Splice bodies as well as most other rubbermolded inline splices currently used in the electrical power
distribution industry.
The 3M copper screen sleeves SG-2 and SG-3 are applied
over molded rubber splices on cables with shield diameters
ranging from 1.25" (32,0 mm) to 2.25" (57,2 mm). In most
cases this will include conductor sizes between 350 kcmil
and 1000 kcmil and voltage classes of 15 kV through 35
kV. The 3M copper screen sleeves SG-2 and SG-3 and the
preformed ground connection braid have a capacity greater
than that of #4 AWG copper wire and are fault current rated
at 15,000 amps for 15 cycles. The 3M Kit SG-3 has a larger
CMA (greater than 2 AWG) copper screen sleeve and two
constant force springs per end. This provides additional
neutral current capacity.
Following SG-2 and SG-3 component installation, 3M
Cold Shrink SJ-1A, SJ-2A, SJ-3A, heat shrink HSJ series
or Scotch Rubber Mastic and Vinyl Tape systems are
the recommended choices for sealing and rejacketing the
installed, shielded splice. Each kit provides shielding and
grounding for one splice.
®
3M Hi-Amp Accessory Grounding Kit 8473 is designed
to accommodate the grounding of accessories installed on
LC, heavy-duty tape and conventional tape-shielded power
cables. The 3M Grounding Kit 8473 design provides a fault
current capacity of 15,000 Amps for 15 cycles on 15 kV, 25
kV and 35 kV class cables.
Product application range for the 3M kit 8473 includes
cable sizes from 350 kcmil through 1000 kcmil in 15 kV
through 35 kV voltage classes as indicated in the table
on page 401.
The kit 8473 was designed to be used with 600-Amp
elbows and other accessories where cable jacket-toaccessory sealing and high-ampacity grounding is desired.
The 3M Grounding Kit 8473 preformed ground braid has
a fault current capacity of 15,000 Amps for 15 cycles with
an equivalent cross-sectional area greater than #4 AWG
copper wire. Each kit provides grounding and sealing
for one accessory.
Refer to the ordering table on page 401 for cable
accommodation. Final determining factor, for cables
not specified, is a shield diameter range from 1.25"
(32,0 mm) minimum through 2.25" (57,2 mm) maximum.
CABLE ACCESSORY PRODUCTS • 3/C Cable Breakout Boots and 3/C Phase Rejacketing System
3M Hi-Amp Splice Grounding
Accessory Kit SG-2 and SG-3
for 15 kV, 25 kV and 35 kV
Refer to the ordering table on page 401 for cable and
accommodation. Final determining factor, for cables not
specified, is a shield diameter range from 1.25" (32,0 mm)
minimum through 2.25" (57,2 mm) maximum.
FAX 800-245-0329
402
3M Hi-Amp Grounding Accessory Kit
GSHA-8 QT-II for 15 kV, 25 kV and 35 kV
™
Tape Shielded Cable
LC Shielded Cable
classes of 15 kV through 35 kV. The preformed ground
braid contained in the 3M Kit GSHA-8 has a fault current
capacity of 15,000 Amps for 15 cycles. Each kit provides
shielding and grounding for one termination.
Refer to the ordering table on page 401 for cable
information. Final determining factor, for cables not
specified, is a shield diameter range from 1.25" (32,0 mm).
3M Cable Grounding Kits 2252 and 2253
™
Jacketed Concentric Neutral Cable (JCN)
3M Hi-Amp Grounding Accessory Kit GSHA-8 QT II
is designed to accommodate the grounding of terminations
made on LC, heavy-duty tape and conventional tapeshielded power cables. The 3M Kit GSHA-8 QT II design
provides a fault current capacity of 15,000 Amps for 15
cycles on 15 kV, 25 kV and 35 kV class cables.
The 3M Kit GSHA-8 is designed to be used in conjunction
with 3M QT-II terminations in applications where highampacity grounding is desired.
The 3M product GSHA-8 will accommodate cable sizes
ranging from 350 kcmil through 1000 kcmil and voltage
403
PHONE 800-245-3573
The 3M Cable Grounding Kits 2252 and 2253 provide
a simple, reliable and secure method for grounding and
resealing of the jacket of direct buried distribution cables.
These kits are designed for use with jacketed concentric
neutral (JCN) power cables ranging from 2 to 4/0 AWG,
rated through 35 kV. A common kit application is for
grounding a primary neutral at least every 1320 feet
(1/4 mile) per Rural Utilities Service (RUS) Bulletin 83-1.
™
Specifications
SG-2
Cable Type
SG-3
8473
GSHA-8
Tape Shielded Cable, LC Shielded Cable
See pg. 399-400 for cable type illustration.
2252
2253
2254
Jacketed Concentric Neutral Cable (JCN)
See pg. 400 for cable type illustration.
Each kit provides grounding and sealing for 1 splice or termination
Each kit provides 1 cable ground
Shield O.D. Range
1.25-2.25"
1.25-2.25"
1.25-2.25"
(132,0-52,2 mm) (132,0-52,2 mm) (132,0-52,2 mm)
1.25-2.25"
(132,0-52,2 mm)
—
—
—
Conductor Range
350-1000 kcmil
350-1000 kcmil
350-1000 kcmil
350-1000 kcmil
2-4/0 AWG
250-500 kcmil
500-1000 kcmil
Circular Mil Area
61,000
72,000
—
—
—
—
—
PST Cold Shrink Tube
—
—
1
—
—
—
—
Roll of Scotch 13
Semiconducting Tape
—
—
—
1
—
—
—
Roll of Scotch 2228
Rubber Mastic Tape
—
—
—
—
1
1
1
Roll of Scotch Super 33+
Vinyl Electrical Tape
—
—
—
—
1
1
1
Tin-Plated Copper
“C” Connector
—
—
—
—
1
1
1
Kit Components:
®
Specifications for 3M Sealing and Grounding Products 15 kV, 25 kV and 35 kV
™
Specifications
SG-2
SG-3
8473
GSHA-8
2252
2253
2254
10" (25,4 cm) Length of
Tin Plated Copper Braid
—
—
—
—
1
1
1
Copper Screen Sleeve
1
1
—
—
—
—
—
Mastic Seal Strip
3
3
1
1
1
1
1
Constant-Force Spring
2
4
1
1
1
1
1
Preformed Ground Braid
1
1
1
1
—
—
—
Instructions
1
1
1
1
1
1
1
UPC (054007-)
50041
41511
50043
50042
08335
55648*
56939*
Case Qty.
10 each
10 each
10 each
10 each
10 each
10 each
10 each
Ordering Information
* UPC prefix 051128-
FAX 800-245-0329
CABLE ACCESSORY PRODUCTS • 3/C Cable Breakout Boots and 3/C Phase Rejacketing System
Specifications for 3M Sealing and Grounding Products 15 kV, 25 kV and 35 kV
404
3M Ground Strap Assembly GS Series
™
3M Ground Strap Assembly Kit GS Series is designed
for grounding tape- and wire-shielded power cables.
Check that cable conductor size matches the ground
strap assembly shown in the ordering table below.
Tape Shielded Cable
Wire Shielded Cable
Specifications and Ordering Information for 3M Ground Strap Assembly GS Series
Specifications
GS-1
Cable Type
Strap Length x Width
GS-2
GS-3
Jacketed URD Cable
See above for cable type illustration.
4.75" x 0.31"
Voltage and Insulation Thickness
7.12" x 0.62"
6.87" x 0.62"
Conductor AWG Size Range (mm )
2
5 kV-100%
90 mils
8-3/0
(10-80 mm2)
2/0-750
(70-325 mm2)
600-2000
(325-1000 mm2)
5 kV-133% 8 kV -100%
115 mils
8-1/0
(10-50 mm2)
1/0-750
(60-325 mm2)
500-2000
(300-1000 mm2)
8 kV-133%
140 mils
8-1
(10-38 mm2)
1-600
(50-300 mm2)
400-1750
(240-850 mm2)
15 kV- 100%
175 mils
—
2-500
(35-250 mm2)
350-1750
(180-850 mm2)
15 kV- 133%
220 mils
—
2-350
(35-180 mm2)
250-1500
(125-725 mm2)
25 kV
260 mils
—
2-400
(35-200 mm2)
3/0-1000
(95-500 mm2)
35 kV
345 mils
—
1/0-300
(60-150 mm2)
1/0-750
(60-325 mm2)
UPC (054007-)
33976
33977
33978
Case Qty.
9 each
9 each
9 each
Ordering Information
405
PHONE 800-245-3573
™
Product Number
CFS-0.47/0.78
CFS-0.80/1.50
CFS-1.00/2.20
CFS-1.50-3.00
CFS-1.50/3.00W
CFS-1.80/4.00
Min. inches (mm)
0.50" (12,7 mm)
0.80" (20,3 mm)
1.00" (25,4 mm)
1.50" (38,1 mm)
1.50" (38.1 mm)
1.80" (45,7 mm)
Max. inches (mm)
0.75" (19,0 mm)
1.50" (38,1 mm)
2.20" (56,0 mm)
3.00" (76,2 mm)
3.00" (76,2 mm)
4.00" (101.6 mm)
Width inches (mm)
0.500" (12,7 mm)
0.625" (15,9 mm)
0.625" (15,9 mm)
0.625" (15,9 mm)
0.750" (19,0 mm)
0.625" (15,9 mm)
30
30
30
9
9
9
42372
42374
42375
42376
42378
42379
Application Range
STD. Carton
UPC (054007-)
3M Shield Grounding Accessory Kits GSK
™
3M Shield Grounding Accessory Kits GSK are used to
convert CN/JCN termination kits for use on shielded cables
minimum through 2.25" (57,2 mm) maximum.
Tape Shielded Cable
LC Shielded Cable
Specifications and Ordering Information for 3M QT-II Termination Kit
™
Product
Number
UPC
(051128-)
QT-II Term.
Kit Number
5 kV
(90 mil)
5/8 kV
(115 mil)
8 kV
(140 mil)
15 kV
(175 mil)
15 kV
(220 mil)
25/28 kV
(260/280 mil)
35 kV
(345 mil)
GSK-22
53087
5641
3/0-300
2/0-250
1/0-4/0
2-3/0
2-1/0
—
—
GSK-34
53088
GSK-56
53089
5651
3/0-300
2/0-250
1/0-4/0
2-3/0
2-1/0
2-1
—
5642
350-750
350-750
250-600
3/0-500
2/0-350
—
—
5652
350-750
350-750
250-600
3/0-500
2/0-350
1/0-250
—
5646
350-750
350-750
250-600
3/0-500
2/0-350
1/0-250
2-3/0
5643
750-1500
750-1250
600-1000
500-1000
350-500
—
—
5644
1000-2000
1000-2000
800-1750
750-1750
600-1500
—
—
5653
750-1500
750-1250
600-1000
500-1000
350-500
300-500
—
5654
1000-2000
1000-2000
800-1750
750-1750
600-1500
600-1250
—
5647
750-1500
750-1250
600-1000
500-1000
350-500
300-500
4/0-400
5648
1000-2000
1000-2000
800-1750
750-1750
600-1500
600-1250
500-1000
Specifications and Ordering Information for 3M QT-III Termination Kit
™
Product
Number
UPC
(051128-)
QT-III Term.
Kit Number
5 kV
(90 mil)
5/8 kV
(115 mil)
15 kV
(175/220 mil)
25/28 kV
(260/280 mil)
35 kV
(345 mil)
GSK-22
53087
7642-T-110
4/0-400
3/0-300
2-4/0
—
—
GSK-34
53088
7642-S-2
4/0-400
3/0-300
2-4/0
—
—
7652-S-4
4/0-400
3/0-300
2-4/0
2-1/0
—
7653-S-4
300-500
250-500
2/0-300
2-4/0
—
7654-S-4
500-750
350-700
4/0-500
2/0-250
—
7644-T-110
500-750
350-700
4/0-500
—
—
7653-T-150
300-500
250-500
2/0-300
2-4/0
2-2/0
7663-S-8
300-500
250-500
2/0-300
2-4/0
2-2/0
7664-S-8
500-750
350-700
4/0-500
2/0-250
2-4/0
FAX 800-245-0329
CABLE ACCESSORY PRODUCTS • 3/C Cable Breakout Boots and 3/C Phase Rejacketing System
Product Information for 3M Constant Force Springs
406
Specifications and Ordering Information for 3M QT-III Termination Kit
™
407
Product
Number
UPC
(051128-)
QT-III Term.
Kit Number
5 kV
(90 mil)
5/8 kV
(115 mil)
15 kV
(175/220 mil)
25/28 kV
(260/280 mil)
35 kV
(345 mil)
GSK-56
53089
7655-S-4
700-1500
600-1250
500-1000
250-800
—
7656-S-4
1750-2000
1500-2000
1250-2000
900-1750
—
7645-T-110
700-1500
600-1250
500-1000
—
—
7646-T-110
1750-2000
1500-2000
1250-2000
—
—
7655-T-150
700-1500
600-1250
500-1000
250-800
3/0-600
7656-T-150
1750-2000
1500-2000
1250-2000
900-1750
700-1500
7665-S-8
700-1500
600-1250
500-1000
250-800
3/0-600
7666-S-8
1750-2000
1500-2000
1250-2000
900-1750
700-1500
PHONE 800-245-3573
3M Scotchcast Insulating and Sealing Compounds
are compatible with most cable insulations and jackets
and accommodate many splices, including odd-shaped
connectors. These compounds feature a high degree
of mechanical strength and provide moisture resistance
for above ground and buried applications.
™
™
Specifications for 3M Scotchcast Insulating and Sealing Compounds
™
Product
Name
Description
Gel Time @ 73°
(23°C)
Energize Time
Used in These
3M Kits
Maximum
Operating
Temperature
Color
Scotchcast Electrical
Insulating Resin 4
PERMANENT
Rigid, hard material
Insulating up to 8 kV
Jacketing up to
69 kV epoxy
16 mins.
45 mins.*
82-A Series
82-B1
85-14CP
90-B1
194°F (90°C)
continuous
266°F (130°C)
overload
482°F (250°C)
intermittent
Black
Scotchcast Electrical
Insulating and
Sealing Compound
2104
PERMANENT
Semi-flexible
1000 volts max.
Polyurethane
18 mins.
Immediately
72-N
85 Series
194°F (90°C)
continuous
266°F (130°C)
overload
Dark
Green
Scotchcast 2123 Reenterable Electrical
Insulating Resin
RE-ENTERABLE
Flexible polybutadiene
62 mins.
Immediately
78-R Series
194°F (90°C)
continuous
266°F (130°C)
overload
Amber,
Transparent
Scotchcast Flame
Retardant Compound
2130
FLAME RETARDANT
Semi-flexible
5000 volts max.
Permanent urethane
MSHA P-142-5
15 mins.
Immediately
Scotchcast
Wet-Niche Potting
Compound 2135
FLEXIBLE
Wet niche putty
Urethane
15 mins.
Immediately
5750, 5760, 5831, 194°F (90°C)
5832, 82-F1,
continuous
82-F2, 82-BF1,
266°F (130°C)
M-20, -30, -40
overload
—
UL Listed 2L02
220°F (105°C)
CABLE ACCESSORY PRODUCTS • Insulating and Sealing Compounds
Insulating and
Sealing Compounds
Black
Black
*At 73°F (23°C) and cooler temperatures, resin will cure slower. Do not energize until resin has cooled and solidified.
FAX 800-245-0329
408
Specifications and Ordering Information for 3M Scotchcast Resins
™
Product Number
UPC (054007-)
™
Size/Type of Package
Inner Unit Pack
Case Qty.
3M Scotchcast Electrical Insulating Resin 4
4-A
43165
A/3.2 oz. (90 g)
4.8 cu. in. (78,6 cu. cm)
—
10 containers
4-B
43166
B/7.4 oz. (209 g)
11.2 cu. in. (183,5 cu. cm)
—
10 containers
4-C
43167
C/14.7 oz. (418 g)
22.3 cu. in. (365,4 cu. cm)
—
10 containers
4-D
04206
D/22.2 oz. (630 g)
33.6 cu. in. (550,6 cu. cm)
—
10 containers
4-E
04207
E/10.4 oz. (294 g)
15.7 cu. in. (257,2 cu. cm)
—
10 containers
3M Scotchcast Electrical Insulating and Sealing Compound 2104
2104-A
31189
A/3.46 oz. (98 g)
5.7 cu. in. (93,4 cu. cm)
cont.
10 each
2104-B
31382
B/7.4 oz. (210 g)
12.6 cu. in. (206,4 cu. cm)
cont.
10 containers
2104-C
31383
C/14.82 oz. (420 g)
25.4 cu. in. (416,2 cu. cm)
1/box
10 containers
2104-D
11849
D/23.8 oz. (675 g)
40.8 cu. in. (668,5 cu. cm)
1/box
10 each
3M Scotchcast Re-enterable Electrical Insulating Compound 2123
2123-C
55120*
C/12.3 oz. (350 g)
23.7 cu. in. (338,3 cu. cm)
1/box
10 each
2123-D
55121*
D/21.2 oz. (600 g)
40.6 cu. in. (665,3 cu. cm)
1/box
10 each
3M Scotchcast Flame Retardant Compound 2130
2130-B
31401
B/7.6 oz. (216 g)
10.7 cu. in. (175,3 cu. cm)
1/box
10 each
2130-C
31402
C/21.7 oz. (616 g)
30.5 cu. in. (499,8 cu. cm)
1/box
10 each
2130 Part A
50237
A/5 gal. (18,93 L)
1 pail
2130 Part B
50238
B/5 gal. (18,93 L)
1 pail
3M Scotchcast Wet-Niche Potting 2135
2135
69798
F/1.83 oz. (52,5 g)
3.3 cu. in. (54,0 cu. cm)
1/box
10 each
F/6.9 oz. (195 g)
12.25 cu. in. (13,12 cu. cm)
—
10 each
3M Scotchcast Cable Repair Compound 2135M
2135M
50433
*UPC prefix 051128-
409
PHONE 800-245-3573
3M Mounting Brackets
MB and MBS Series
™
The 3M Mounting
Brackets MB and
MBS Series have
been designed to
mount 3M molded
rubber terminations.
These brackets are
attached to the cable
Single
Clamp
Double
Clamp
just below the
termination. This
provides a tongue
that can then be attached to an MB-1 mounting bracket or
to any other support. The 3M Brackets MB Series are made
from galvanized steel. The 3M Brackets MBS Series are
made from stainless steel to provide additional corrosion
protection in highly contaminated environments.
3M Cross-Arm Mounting Bracket MB-1
™
3M Cross-Arm Mounting Bracket MB-1 is a cross-arm
bracket for use in holding terminated cable. The MB-1
is ideal to use when ordering the MB or MBS termination
mounting brackets featured on this page.
CABLE ACCESSORY PRODUCTS • Mounting Brackets
Mounting Brackets
Specifications and Ordering Information for 3M Hardware Accessories
™
Product Number
UPC
(054007-)
Cable
O.D. Range
Inner
Unit Pack Qty.
Case
Qty.
MB-1
11230
—
1/box
10 each
MB-3
14754
0.80-1.25" (20-32 mm)*
1/box
10 each
MB-4
14755
1.10-1.50" (28-38 mm)
1/box
10 each
MB-5**
08200
1.45-1.95" (37-50 mm)
1/box
10 each
MB-6**
08286
1.80-2.40" (46-61 mm)
1/box
10 each
MBS-4**
49685
1.10-1.70" (28-43 mm)
1/box
10 each
MBS-5**
49686
1.45-1.95" (37-50 mm)
1/box
10 each
MBS-6**
49687
1.80-2.40" (46-61 mm)
1/box
10 each
*Caution: Use cable O.D., not insulation O.D. for determining the proper size.
**Has double clamps.
FAX 800-245-0329
410
3M Cold Shrink Corrosion
Protection Kit CPT Series
™
3M Cold Shrink Corrosion Protection Kit CPT Series are
designed to provide a quick and easy method for protecting
bulkhead termination connectors from the corrosive
influences of wet and salt-fog installation environments.
A CPT series assembly is an open-ended tubular rubber
sleeve which is factory expanded and assembled onto a
removable core. The core is removed after the assembly
has been positioned for installation over a bulkhead
terminator connector. Mastic strips are provided for
sealing between NPT fitting threads and the enclosure
in use (junction box, cabinet, panel board, etc.). CPT
insulating sleeves are made of an EPDM rubber that
contains no chlorides or sulfers. Ten kits accommodate
1/2" through 4" bulkhead connectors.
To extend the useful life of this product in applications
where continuous exposure to high levels of ultra-violet
radiation are expected, overwrap with Scotch Super 33+
Vinyl Electrical Tape or Scotch Silicone Tape 70.
®
™
Features:
• Simple installation, requires no tools
• Accommodates a wide range of bulkhead connectors
• No torches or heat required
• Good thermal stability
• Are designed to seal tight, retain its resiliency and
pressure after prolonged years of aging and exposure
• Excellent wet electrical properties
• Salt spray resistant. Meets requirements of ASTM B287,
in a 5% salt solution with a 3.0-3.1 pH
• Water-resistant. Meets the water seal requirements
of ANSI C119.1
• Resists fungus
• Resists acids, alkalies and ozone
3M Cold Shrink Corrosion Protection Kit CPT Series Sizing Guide
UPC
(054007-)
Maximum O.D.
in. (mm)
Maximum Installed
Length in. (mm)
Inner
Unit Pack
Min. Order
Case Qty.
CPT-1/2
43021
0.50" (13 mm)
1.60" (41 mm)
4.50" (114 mm)
—
10
CPT-3/4
43022
0.66" (17 mm)
1.90" (48 mm)
4.80" (122 mm)
—
10
CPT-1
43023
0.66" (17 mm)
2.20" (56 mm)
4.80" (122 mm)
—
10
CPT-1-1/4
43024
1.22" (31 mm)
2.65" (67 mm)
4.80" (122 mm)
—
10
CPT-1-1/2
43025
1.40" (36 mm)
3.00" (76 mm)
5.50" (140 mm)
—
10
CPT-2
43026
1.68" (43 mm)
3.60" (91 mm)
6.50" (165 mm)
—
10
CPT-2-1/2
43027
1.97" (50 mm)
4.30" (109 mm)
8.50" (215 mm)
—
5
CPT-3
43028
2.60" (66 mm)
5.40" (137 mm)
8.50" (215 mm)
—
5
CPT-3-1/2
43029
2.90" (74 mm)
6.00" (152 mm)
10.0" (254 mm)
—
5
CPT-4
43030
2.90" (74 mm)
6.00" (152 mm)
10.5" (267 mm)
—
5
Product Number
(NPT Size)
411
Connector
Cable O.D.
Minimum
in. (mm)
PHONE 800-245-3573
™
Cable Jacket Range
(inches)
Trade Size
(inches)
(NPT Size)
Min.
Max.
Crouse-Hinds
(TMC or TMCX)
Appleton
T&B
O-Z/Gedney
1/2"
0.46"
0.71"
TMCX165
TMCX6550
ST050-462
ST050-464
JMC-50-71
3/4"
0.65"
0.93"
TMCX285
TMCX8875
ST075-467
ST075-468
JMC-75-115
1"
1.10"
1.45"
TMCX3112
TMCX118100
ST100-469
JMC-100-145
1-1/4"
1.37"
1.79"
TMCX4140
TMCX140125
ST125-470
ST125-550
ST125-471
JMC-125-179
1-1/2"
1.74"
2.15"
TMCX5161
TMCX166150
ST150-472
ST150-473
JMC-150-215
2"
2.03"
2.59"
TMCX6206
TMCX206200
ST200-551
ST200-474
ST200-475
ST200-476
JMC-200-259
2-1/2"
2.47"
3.03"
TMCX7247
TMCX251250
ST250-477
ST250-478
JMC-250-303
3"
2.93"
3.61"
TMCX8302
TMCX304300
ST300-479
ST300-480
ST300-481
JMC-300-361
3-1/2"
3.55"
4.23"
TMCX9352
TMCX359350
ST350-482
ST350-483
JMC-350-423
4"
4.05"
4.73"
TMCX10402
TMCX402400
ST400-484
ST400-485
JMC-400-473
FAX 800-245-0329
CABLE ACCESSORY PRODUCTS • 3M™ Cold Shrink Corrosion Protection Kit CPT Series
3M Metal Clad Jacketed Cable Connectors — Connector Cross Reference
412
Preparation and Cleaning
3M Cable Cleaning System CC Series
™
3M Scotch-Brite Hand Pads 7440 Series
™
™
3M Scotch-Brite Pads make the toughest cleaning jobs easier.
These pads are so versatile. They are designed to outperform
steel wool, wire brushes, sandpaper and other nonwoven
surface conditioning products and can be used with water
or solvents. They resist tearing, splintering, shredding and
loading and will never rust. All Scotch-Brite Pads measure
6" x 9" (152 x 228 mm). Blending Pads are made of a coarse
mineral abrasive. General Purpose Pads are reusable—they
rinse clean and are constructed of a nylon web. Ultra Fine
Pads are highly conformable.
Select the Scotch-Brite Pads for your specific abrasion
needs and carry them with you everywhere you work.
You can use them on virtually any surface material,
including all kinds of metals, plastics, composites,
ceramics, porcelain, glass and rubber.
413
PHONE 800-245-3573
3M Cable Cleaning System CC Series cleans cable
insulation, metal, electrical and mechanical parts. It can be
used for PCB cleanup and in parts cleaners for degreasing.
CC series solvent is also suitable for use on transformers,
generators, motors and metal parts of all sorts. It removes
surface oils, tars and heavy greases. Use of solvent on
carbon-containing semiconductive surfaces such as cable
insulation shields is not recommended.
CC series solvent can effectively replace 1.1.1- trichlorethane
and other hazardous solvents. Neither CC series solvent
nor its ingredients are presently subject to regulations that
would inhibit shipping, packaging or applications.
CC-Dry contains three each 4" x 8" (102 x 203 mm) lintless
non-woven pads packed in a bag. These are used for drying
the common citrus cable cleaner (CC series) off of cable
installation when preparing cable. The CC-2-Dry Kit
contains a CC-2 Kit and three each dry lintless pads.
™
Specifications
Blending Pads 7446
Features
General Purpose Pads 7447
· Hand blending and finishing
stainless steel and aluminum
· Light oxide removal
· Paint removal
· Wood highlighting
Ultra Fine Pads 7448
· Scuff sanding, cleaning, finishing
· Light duty — ideal for cosmetic
and deburring
cleaning and creating consistent
· Use for car reconditioning — cleaning finishes
upholstery, headliners, white-wall tires,
door pads and chrome
· Deburring metals and ceramics
· Cleaning machinery
Electrical Applications
· Cleaning cable jackets, insulation and conductors
· Cleaning and polishing bus bar
· Cleaning insulators and cable accessories
· Rust removal from metal cabinets
· Relay contact cleaning
· Battery connections
Color
Gray
Maroon
Gray
Size
6 x 9" (152 x 228 mm)
6 x 9" (152 x 228 mm)
6 x 9" (152 x 228 mm)
Ordering Information
UPC (048011-)
04051
04029
04028
Pads/Box
1
1
1
Case Qty.
1 case
1 case
1 case
Specifications and Ordering Information for 3M Cable Cleaning System CC Series
™
Specifications
CC-2
CC-Dry
CC-2-Dry
CC-3
CC-4
Cable Cleaning
Preparation Kit
Cable Cleaning Pads
Cable Cleaning Pads
and Kit
Cable Cleaning Pad Kit
Cable Cleaning Solvent
(quart bottle)
Ordering Information
CC-2
CC-Dry
CC-2-Dry
CC-3
CC-4
UPC (054007-)
49563
43415
43414
49564
49565
Case Qty.
10 each
10 kit
10 kit
10 each
4 each
Description
CABLE ACCESSORY PRODUCTS • Preparation and Cleaning
Specifications and Ordering Information for 3M Scotch-Brite Hand Pads 7440 Series
Scotch Electrician’s Abrasive Roll A-3
®
Scotch Electrician’s Abrasive Roll A-3 is a 120-grit, closedcoat aluminum oxide strip, which is nonconductive and
flexible. It is packaged in a dispenser-type box.
Ordering Information for Scotch Electrician’s Abrasive Roll A-3
®
Product
Number
A-3
UPC
(054007-)
Size/Type of
Package
Inner
Unit Pack
Case
Qty.
11560
1" x yd./Grit 120J
(25,4 mm x 22,7 m)
5 rls
10 rls
FAX 800-245-0329
414
3M Electrostatic
Animal Guard
™
3M Electrostatic Animal Guard (formerly Guthrie
Guard) is a patented electrostatic barrier which attaches
to energized electrical insulators/bushings rated up to 35
kV. The guard consists of rugged plastic with metal spokes
radiating outward. When an animal touches the spokes,
it receives an electric shock similar to those generated by
electrified livestock fences. The animal is not injured and
power service is not interrupted.
With 3M Electrostatic Animal Guard, electric utilities
can minimize customer outages due to animal contact.
3M Electrostatic Animal Guard offers several advantages
over other conventional cover-up devices:
• Can be installed while circuit is energized
• Maximum longevity
• Humane
3M Electrostatic Animal Guard Specifications and Ordering Information
Product Number
UPC (054007-)
Insulator Neck Diameter Range* in. (mm)
GG-7525
43128
0.75-2.5" (19,1-63,7 mm)
GG-1525
43125
1.5-2.5" (38,2-63,7 mm)
GG-2545
43126
2.5-4.5" (63,7-114,7 mm)
GG-4565
43127
4.5-6.5" (114,7-165,7 mm)
*Insulator neck diameter range is defined as the diameter of the insulator in between the skirts.
Contamination rinse nubs for stand-off protection
from insulator surface.
Electrostatic prongs angle up, over
and across an animal’s path.
Wind gust retention spring.
UV resistant polypropylene with
excellent dielectric strength.
Hot stick spring loop connection
allows for smooth installation/
removal.
Colored scarlet red for high visibility
and animal deterrence.
415
PHONE 800-245-3573
Insulation extended to provide flashover
protection.
Approximately 45% of line to ground
voltage of electrostatic energy at all points.
3M Conductor Covers CCI Series are extruded silicone
rubber tubes designed for field installation over bare
conductors to insulate them from adjacent phases,
grounded equipment, and animal contact. These covers
are made with a full-length longitudinal bias cut to allow
for easy slip-on installation, and provide an increased
creepage distance between the conductor and the outer
surface of the cover.
™
Typical Dimensions
The covers are offered in two thickness sizes for covering
B
both 15 kV and 25 kV rated conductors, and are available
in ACSR conductor sizes from 2 AWG to 266 kcmil.
Features:
• Excellent UV, arc and ozone resistance
A
• Good dielectric strength, conformability and cold
weather installation
3M™ Conductor Covers CCI Series
• Munsel grey color
• Bias cut enables easy field installation without any
special tools
Specifications and Ordering Information for 3M Conductor Covers CCI Series
UPC
(054114-)
ACSR
Conductor
Size
Conductor
Voltage
Rating
Dimension A
Dimension B
Order Quantity
CCI-2-125
04238
2 AWG
15 kV
0.34" (9 mm)
0.125" (3 mm)
100 ft. rolls
CCI-2/0-125
04239
2/0 AWG
15 kV
0.46" (12 mm)
0.125" (3 mm)
100 ft. rolls
CCI-266-125
04241
266 kcmil
15 kV
0.63" (16 mm)
0.125" (3 mm)
100 ft. rolls
CCI-2/0-200
04240
2/0 AWG
25 kV
0.46" (12 mm)
0.200" (5 mm)
100 ft. rolls
CCI-266-200
04242
266 kcmil
25 kV
0.63" (16 mm)
0.200" (5 mm)
100 ft. rolls
Product
Number
FAX 800-245-0329
CABLE ACCESSORY PRODUCTS • Overhead Conductor Animal Guard Cover
Overhead Conductor
Animal Guard Cover
416
417
PHONE 800-245-3573
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
3M:
SS-31-10-P SS-31-8 SS-31-8-P SS-31-10 SS-32-10 SS-31-6-NB SS-31-6 SS-32-10-P SS-32-8-P SS-32-8 SS31-6-P SS-32-6-P SS-31-4 SS-31-4-NB SS-31-8-NB SS-31-10-NB SS-32-4-NB SS-32-4-P SS-32-6-NB SS-32-8NB SS-32-10-NB SS-32-14 SS-32-14-NB SS-32-14-P SS-33-6 SS-33-6-P SS-33-8 SS-33-8-NB SS-33-8-P SS33-10 SS-33-10-NB SS-33-10-P SS-33-14 SS-33-14-NB